Pro sKit MT-7625 Optical Power Meter and Tone Probe Kits Owner’s Manual
- June 16, 2024
- Pro sKit
Table of Contents
- MT-7625 Optical Power Meter and Tone Probe Kits
- Host
- Display Description
- Optical Power Meter
- OPM Data Storage and Viewing
- OPM Offset Setting
- Network Cable Test(Module)
- Network Cable Test(Receiver)
- Network Cable test-Crimping Function
- Network Cable Tracing-Host Settings (Analog)
- Receiver- NCV Function
- Receiver-LED light function
- Data Communication
- Specification
- Troubleshooting
- Documents / Resources
MT-7625 Optical Power Meter and Tone Probe Kits
MT-7625
Optical Power Meter & Tone Probe Kits
User’s Manual
Host
1 VFL Connector
2 LED Light
3 OPM Connector
4 RJ45 Socket(Continue and crimping test)| 5 Keypad
6 RJ45 Socket(Network cable tracing)
7 Type-C Port
8 Network Cable Test Module
---|---
Receiver
1 Probe
4 Keypad
7Type-C Port| 2 Headset Jack
5 LED Light
8 RJ45 Socket| 3 Status Indicator
6 Power Switch
---|---|---
Display Description
1 VFL
2 LED Light
3 USB
4 Power
5 Auto Power-off
6 Battery Level| 7 OPM Information Area
8 Test Socket Position
9 RJ45 Cable Test
10 Network Cable Crimping
11 Cable tracing(analog)
12 Cable tracing(digital)
---|---
On/Off(Host)
Short press “ ” to turn on the power with auto-off function, automatically shut down after 10 minutes of no operation. To turn off the auto-off function, long press “ ” to turn on the device in the off state. The “ ” icon lights up at the top, indicating that the auto-off function is turned off. After power on, short press “ ” to turn on/off backlight,long press to turn off the power. Long press “ ” to shut down the power in any interface.
Charge(Host)
Use the recommended power
adapter and cable to connect to the Type-c interface. The “ ” icon lights up,
indicating that the power supply is connected. The “ ” icon displays
dynamically increasing, and when fully charged, the “ ” icon remains static.
*Recommended power adapter specifications: 5V/1A
Charge(Receiver)
Use the recommended power adapter and cable to connect to the Type-c
interface. The icon lights up, indicating that the power supply is connected.
Green light, battery power is normal.
The green light flashes, indicating low battery power.
Red light, charging status.
*Recommended power adapter specifications: 5V/1A
Optical Power Meter
After power on, short press the “ ” to switch the measurement wavelength. The device supports measurement of 10 calibration wavelengths: 850nm,980nm, 1270nm, 1300nm, 1310nm, 1490nm, 1550nm, 1577nm, 1625nm, 1650nm. Short press the “ ” to switch units and view the REF setting value. Long press to set the current measurement value as the new REF value.
OPM Data Storage and Viewing
- Storage: Long press “ ” in the optical power meter interface to store the current measurement information, and the current storage serial number will be displayed on the interface. The device can store up to 500 pieces of data. After 500 pieces of data are exceeded, the first record will be overwritten.
- View: Long press “ ” in the optical power meter interface to enter the stored value viewing interface. Use the “ ” and “ ” to turn pages, and long press is supported to turn pages quickly. Short press the “ ” to exit the storage interface.
OPM Offset Setting
Long press ” ” to enter the offset setting interface, short press “ ” to switch wavelength, short press “ ” , and “ ” to adjust the set offset, the setting range is [-5, +5], short press “ ” , confirm the offset setting, and exit.
VFL/LED Light
- Short press “ ” to switch VFL output mode: CW/Glint/OFF. The “ ” icon will be displayed in sync status.
- Short press “ ” to turn on/off LED lighting.
The “ ” icon will be displayed in sync status.
Network Cable Test(Module)
Unplug the network cable test module, short press “ ” to enable the network cable test , the “ ” icon will display the synchronization status. Connect both ends of the network cable to the host and module respectively. You can judge whether the network cable is qualified based on the lighting status of the host UI (1,2,—8,G) and module indicators corresponding. ” ” flashes to indicate that the network cable is plugged into the RJ45 test socket on the left.
Network Cable Test(Receiver)
Short press “ ” to
enable the network cable test , and the “ ” icon will display the
synchronization status.
Connect both ends of the network cable to the host and module respectively.
You can judge whether the network cable is qualified based on the lighting
status of the host UI (1,2,—8,G) and module indicators corresponding.
Network Cable test-Crimping Function
Short press “ ” twice to enable the network cable test crimping function, and
the “ ” icon will be displayed in sync status.
Connect the tested connector to the RJ45 test socket on the left side of the
host. You can judge whether the network cable is qualified according to the
lighting status of the host UI indicator. “ ” lights up if the crimping test
fails, and the LED light flashes corresponding to the core number of the failed
crimping wire. “ ” lights up and the crimping test is passed.
“▶” flashes to indicate that the network cable is plugged into the RJ45 test
socket on the left.
Network Cable Tracing-Host Settings (Analog)
Short press “ ” three times to turn on the cable tracing function (analog),
the “ ” icon will display the synchronization status, and the “ ” LED will
flash continuously.
Connect the cable connector to the RJ45 test socket on the right side of the
host. At this time, the host setting of the cable tracing function is
completed and to set the receiver.
” ▶” flashes to indicate that the network cable is plugged into the RJ45 test
socket on the right.
Network Cable Tracing-Receiver Settings (Analog)
The red indicator light is on, indicating that the receiver is in analog signal receiving mode, and the greenindicator light is on, indicating that the receiver is in digitalsignal receiving mode.
Turn the receiver knob clockwise to turn the
receiver on. Short press “ ” to turn on the cable tracing function (analog).
At this time, the receiver will beep and the red backlight of the button will
light up.
When the probe gradually approaches the test network cable, the receiver will
emit regular beep reminders and the light ring above will flash. The adjustment
knob on the receiver is used to adjust the sensitivity (clockwise to the end
for the highest sensitivity).
▲Note: When searching for cables in the network, due to the network switch
(the transmitter transmits the signal and transmits it to other network cable
ports through the internal circuit of the switch), several network cables
close to the target network cable may have audio signals. In this case, you
can try to turn the receiver sensitivity knob counterclockwise to reduce the
receiving sensitivity to find the target network cable.
Note: The modes of the host and receiver need to be consistent, otherwise
the signal will not be received.
Network Cable Tracing-Host Settings (Digital)
Short press “ ” four times to
turn on the cable tracing function (digital), the “ ” icon will display the
synchronization status, and the “ ” LED will flash continuously.
Connect the cable connector to the RJ45 test socket on the right side of the
host. At this time, the host setting of the cable tracing function is
completed and to set thereceiver.
“▶” flashes to indicate that the network cable is plugged into the RJ45 test
socket on the right.
Network Cable Tracing-Receiver Settings (Digital)
Turn the receiver knob
clockwise to turn the receiver on. Short press “ ” to turn on the cable
tracing function (digital). At this time, the receiver will beep and the green
backlight of the button will light up.
When the probe gradually approaches the test network cable, the receiver will
emit regular beep reminders and the light ring above will flash. The adjustment
knob on the receiver is used to adjust the sensitivity (clockwise to the end
for the highest sensitivity).
▲Note: When searching for cables in the network, due to the network
switch (the transmitter transmits the signal and transmits it to other network
cable ports through the internal circuit of the switch), several network
cables close to the target network cable may have audio signals. In this case,
you can try to turn the receiver sensitivity knob counterclock- wise to reduce
the receiving sensitivity to find the target network cable.
Note: The modes of the host and receiver need to be consistent, otherwise
the signal will not be received.
Receiver- NCV Function
Turn the receiver knob clockwise to turn the receiver on. Short press “ ” to
turn on the NCV mode. When a voltage greater than the threshold is detected,
the receiver horn will make a “beep” sound, and the ring light on the probe
will flash.
Note: Nearby external interference sources (such as the charger without
grounding, etc.) may trigger non-contact voltage detection.
Even if there is no indication, voltage may still be present. Don’t rely
solely on a non-contact voltage detector to determine whether voltage is
present on a wire. Detection operations may be affected by factors such as
socket design, insulation thickness and type.
Receiver-LED light function
Turn the receiver knob clockwise to turn the receiver on. Short press “ ” to turn on the LED light function.
Data Communication
Communication: Use a USB-C data cable to connect the host to the PC, install
the communication software on the PC to perform data transfer operations. The
“ ” icon flashes, indicating that communication is in progress.
Software download link: https://www.prokits.com.tw/Product/MT-7625/
Specification
Optical Power Meter Specifications and Functions
Detector Type | InGaAs |
---|---|
Wavelength | 700-1700nm |
Response Range OPM Connector | 2.5mm universal connector |
Measurement Wavelengths | 850/980/1270/1300/1310/1490/1550/1577/1625/ 1650nm |
Measurement Range | -70~+10dBm |
Accuracy* | (1550,1310nm)±0.2dB,(850nm,980nm,1300nm,1490 |
nm,1625nm,1650nm)±0.3dB,(1270nm,1577nm)±1dB
Resolution| 0.01dB
Unit| dB,dBm, mW, uW, nW
Modulation Detection| 270/330/1k/2kHz(Only for Pro’sKit Light Source products)
Data Storage| 500 groups
Wavelength Memory| Yes
User Self-calibration| Yes
REF| Yes
Back Light| Yes
Visual Fault Locator Functions
Output Power| 15mW
Testing Distance*| 10-12km @SM
VFL Connector| 2.5mm universal connector
Wavelength| 650±20nm
Operation Mode| CW/2Hz Glint
Network Line Sequence Function
Applicable network| UTP/STP Network Cable
Cable Interface| RJ45 (8P8C+G)
Test Type| Network Cable Sequence
Test Distance| 600m
Audio Hunt function
Hunting Function| Analog & Digital Mode
Detection Frequency| 455kHz
Detection Distance| 600m
Line Pressing Function
Crimp Detection| RJ45 8pin: >10cm
Illumination| LEDx1
Auto Power-off| Yes(no operation in 10 minutes)
Low Battery Indicator| Battery level
Charging Socket| Type-C
Charging time| <3hours
Working Time| >30 hours(only OPM)
Power Source| Li-ion 3.7V/450mAh
Operating Temperature| -10~50℃
Humidity| <90%RH
Size| 1146529mm
Weight| 120g
Receiver Specifications and Functions
Power Switch| Knob Operation
Function Selection| Silicone ButtonX3
Response Frequency| 455KHz
Volume| ≥85dB
Receiver Signal| Analog/ Digital
Speaker Audio| Analog Detection (633Hz/833Hz) & Digital
Detection(833Hz/1500Hz)
Sensitivity| Knob Adjustment
Test Interface| RJ45× 1
Line Sequence Indicator| LED ×9
Status Indicator| LED× 3
Non-contact Electricity Test Function
Non-contact Voltage Detection| AC 90V-1000V
Indicator Light| LED ×1(ring)
Speaker Audio| 1500HZ
LED Light Functions
Illumination| LED×1
Headset Jack| Φ3.5mm×1
Charging Socket| Type-C
Power Source| Li-ion 3.7V 450mAh
Working Current| ≤250mA
Size| 18045*26mm
Weight| 100g
Packing List| Type-C Charging Cable x1, Headset x1, RJ45 Patch-cord x1,
Alligator Clip Patch-cord x1, Bag, User Manual
*At 23℃±2℃, 40%-60%RH, with standard testing fiber.
Accuracy range: +3dBm~-60dBm, other references are as follows:
±0.8dB: +3dBm~+6dBm, -60dBm~-65dBm@1550nm ±3.0dB:
+6dBm-+10dBm,-65dBm–70dBm@1550nm
Test distance will be influenced by environmental conditions and visual
sensitivity.
General maintenance**
The fiber optic connector should avoid contact with hard objects and keep
clean. When storing, keep it ventilated and dry to avoid moisture. When not in
use for a long time, charge it once every 3 months to 50%-80% of the battery.
Troubleshooting
Failure | Failure Cause | Solution |
---|---|---|
Cannot power on | battery power is too low | Charge the battery |
mmediately shutdown after power on | Low battery | Charge the battery |
The operation is invalid | The instrument program is disordered | turn on the |
device again
improper measurement error| The face of the light port is dirty| Clean the
fiber optic connector
http://www.prokits.com.tw
PROKIT’S INDUSTRIES CO., LTD
https://www.prokits.com.tw
Email:pk@mail.prokits.com.tw
©2023 Prokit’s Industries Co., LTD. All rights reserved 2023001(C)
Documents / Resources
| Pro
sKit MT-7625 Optical Power Meter and Tone Probe
Kits
[pdf] Owner's Manual
MT-7625 Optical Power Meter and Tone Probe Kits, MT-7625, Optical Power Meter
and Tone Probe Kits, Power Meter and Tone Probe Kits, Meter and Tone Probe
Kits, Tone Probe Kits, Probe Kits
---|---
| Pro
sKit MT-7625 Optical Power Meter and Tone Probe
Kits
[pdf] User Manual
MT-7625 Optical Power Meter and Tone Probe Kits, MT-7625, Optical Power Meter
and Tone Probe Kits, Power Meter and Tone Probe Kits, Meter and Tone Probe
Kits, Tone Probe Kits, Probe Kits
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>