scandomestic OFC390B Professional Coolers User Manual
- June 16, 2024
- scandomestic
Table of Contents
OFC390B
User manual
Operation instructions
Thank you for choosing and purchasing our product. Please carefully read the
operation instructions before use for a correct application and satisfactory
effect.
This appliance compliance with the requirement of directive 2006/42/EC.
General
This product is a type of chilling cabinet, which is our new development of refrigeration combining the advanced technologies from both and abroad on the basis of food cabinet standards and corporate criteria. Its main kits and key components are all good brands, either and streamlined design, the product integrates the actual market demand in structural design, which better cater to the ergonomics requirements of consumers. This series applies mainly to displaying and selling of drinks, dairy products, vegetables and fruits.
Structure and Parts
Handle and placement
Handle with care
Unplug the wall socket first.
Never tilt it over 45 degree during handling
Dry place
Always locate the refrigerator at a dry place.
Sufficient space
The distance from both sides and back of refrigerator to wall or other
substance must not less than 10cm. The refrigeration capability might be
decreased if its surround space is too small to circulate air.
Well ventilation
Always locate the refrigerator at a place with fine ventilation. For the first
time use, wait for 2 hours after handling and then plug the wall socket and
start it.
Far from heat source
Never place the refrigerator directly under the sunshine. Never locate it
nearby any heat source or heater to prevent it from reducing refrigeration
capability.
No heavy load
Never put any heavy load on the top of the refrigerator.
No hole making
Never make hole on the refrigerator. Never install other matter on the
refrigerator.
Stable location
To avoid the unexpected noise and vibration, Unpacking and locate the
refrigerator on a flat and solid place.
Preparation and Power Supply
Power socket
Normally, the power supply should be 220-240V, single phase AC with exclusive
single phase three pin receptacle (250V 10A) and fuse (6A). The power
receptacle must have a reliable earth connection.
No share on socket
Never let the refrigerator share the common socket with other appliance,
otherwise the cable becomes hot and fire might be resulted.
Protect cables
Never break or damage the cables otherwise current leakage and fire might be
resulted.
No water flushing
Never give the refrigerator surface a flush otherwise current leakage might be
resulted.
Prevent from flammables and explosive
Never put any flammable or explosive inside the refrigerator such as ether,
gasoline, alcohol, adhesive and explosive. Never put dangerous product nearby
the refrigerator.
No spray
To s p ray the flammables such as paint or coating nearby the refrigerator is
not allowed, otherwise fire might be resulted
After power break
After power break or unplugging the refrigerator, always wail at least 5
minutes and then you may plug the refrigerator and start it again.
No medicine
No medicine is allowed to keep inside the refrigerator.
Use and Caution
Before use:
Plug the refrigerator on 220-240V~ exclusive socket.
After the refrigerator running, put hand on the air suction to confirm it is
sufficient cold. Then you may put food inside the cold box.
This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the
appliance.
This operation manual is not suitable for the persons (including children)
with reduced physical, sensory or mental capabilities, or lack of experience
and knowledge.
Digital temperature controller
Control
It is a mini-sized and integrated intelligent controller and applicable to the
compressor of one Hp.
The main functions are:
- Temperature display
- Temperature control
- Manual, automatic defrost by burning off
- Illumination Control
- Value Storing
- Self Testing
- Parameter Locking
Front Panel Operation
Set temperature
Press “SET“ button, the set temperature is displayed.
Press “UP“ or “DOWN” button to modify and store the displayed value.
Press “SET“ button to exit the adjustment and display the cold-room
temperature.
If no more button is pressed within 10 seconds, the cold-room temperature will
be displayed.
Illumination: press “LIGHT” button, it light; Press again, it stop.
Manual start/stop defrost: press the “LIGHT” button and hold for 6 seconds to
defrost or stop defrost.
Refrigerant LED: During refrigeration, the LED is on; When the cold room temp.
is constant, the LED is off; During the delay start, the LED flashes.
Defrost LED: during defrosting, the LED is on; When is stops defrosting, the
LED is off, During the delay display of defrost, the LED flashes.
Digital controller reset
When display shows “Disorder”, press “DOWN” button for 2s until buzzer rings,
quickly press “UP” button for 6s until buzzer rings again, the display will
flash for 3s and it restores factory setting.
Cautions
If the supply cord is damaged, it must be replaced by the manufacturer, its
service agent or similarly qualified persons in order to avoid a hazard.
Never block the air suction and outlet. Keep air circulation and refrigeration
capability.
Do not make food congested as it will influence the cooling effect. Adjust the
rack height for proper food storage.
Cool the hot food down to room temperature before you put it into the
refrigerator.
Try to pull down the curtain and keep refrigerator inside cold in case the
power is cut off.
Never touch compressor to avoid from scald.
During normal operation, the emission noise level does not exceed 70 dB(A).
The maximum loading of the Shelf does not exceed 18 kg.
The climatic class of the appliance is 6, the units are suggested to be used
at 16°C – 27°C ambient temperature.
To avoid damages or other problems, this product cannot be put or stored with
any corrosive food.
Maintenance
Cabinet cleaning.
The product should be cleaned once a week with power supply disconnected. When
cleaning, please use mild rinsing water or non-corrosive essence. Do not wash
it directly with a water hose.
Cleaning for filter
To keep the device in good working condition, the condenser should be cleaned
every 1 months.
Message “EE4” appearing on the display, please clean the condenser
immediately.
After cleaning, if message “EE4” appearing again, please contact your after
service.
Instructions for Cleaning
Before beginning
with cleaning filter, please make sure the device has been disconnected from
power socket.
Remove 2 screws from the top of the front grill, see drawing
A. After the screws are loose, please take off the bottom front panel, see
drawing
B. Remove the dust with wire brushes or high pressure cleaner. Leaking check.
Observe all connectors and welding joints for oil stain, which indicates a
must for patching measures or call for professionals.
Frequently observe the operation of the product, in case of any abnormal
noise, smell or smog, cut off the power supply immediately and call for
professionals for help. Do not restart the product before trouble is cleared.
We will not be responsible for any accident incurred by failures of following
the notices.
Trouble Shooting
No | Troubles | Causes | Solutions |
---|---|---|---|
1 | Strange noise under the bottom shelf | Fan blade broken | Power off and fix |
the blade
2| Non-refrigerating in spite of normal operation| Unit off. Melting process
Refrigerant leaking Unit failure| Power on Stop melting Patch the leak and
refill refrigerant Call for professionals
3| Weak air from air curtain, and higher cabinet temperature| Evaporator
blocked by frost Inside fan damaged Too low set point of temperature
controller Vent blocked by storage| Increase melting frequency Replace the fan
Adjust the set point Remove the storage
4| Normal air curtain, but higher cabinet temperture| Insufficient refrigerant
Too high set point of temperature controllers The wind curtain disturbed by
strong air flow Ambient temperature or humidity beyond standards| Refill the
refrigerant Adjust the set point for the temperature controller Removing the
disturbing factors Improve the conditions
5| Melting water overflown| Heating pipe for melting water damaged Water-level
controller failure Ambient temperature or humidity beyond standards| Replace
the heating pipe Replace the water-level controller Improve the conditions
6| Normal air curtain, but Periodical fluctuation of cabinet temperature|
Condenser contaminated Poor venting of the unit Heat protection of compressor
failure Capillary is blocked by ice Temperature controller failure| Clean the
condenser Improve the venting conditions Replace the heat protection Replace
the drying filter Replace the temperature controller
Note
Following phenomena are not troubles
The murmur of water is heard when the refrigerator is working. It is a normal
phenomenon as the coolant is circulating in the system.
In wet season, condensation might be found on the outside of the refrigerator.
It is not a trouble, which is caused by high humidity. Simply use cloth to
wipe it.
Principle of Refrigeration System
The principle of compression refrigeration consists of “compression”, “condensation”, “throttling” and “vaporization”. The compression is undertaken by compressor, the condensation is completed by condenser, the throttling valve is executed by capillary and the vaporization is implemented by evaporator. When the coolant is circulating in the closed refrigeration system, the compressor sucks coolant, which has absorbed the heat in evaporator, the coolant becomes a high pressure and high temperature gas. In condenser, it dissipates heat in air, while the coolant is reliquefied and throttled in capillary and then enters into evaporator with low pressure. The liquefied coolant quickly boils and vaporizes into gas when the pressure suddenly drops. Meanwhile, it absorbs heat inside the refrigerator. And the compressor sucks the low pressure and low temperature gaseous coolant, it is circulating in this way up to realization of intended refrigeration.
Circuit Diagram
Major Parameters
Coolant and injection quantity (g) | R290 (148) |
---|---|
General Rated input power (W) | 1300 |
Power running of electrical heating element (W) | 490 |
Max. ambient temp. /RH | <27°C / 70% |
Refrigeration Temperature (°C) | 2-10 |
Rated voltage (V) | 220-240 |
Rated frequency (Hz) | 50 |
Rated current (A) | 6.7 |
Type of Climate | 6 |
Foaming agent | Cyclopentane |
Net weight (kg) | 130.5 |
Lamp power (W) | 2.5 x 2 (LED) |
Total effective volume (L) | 320 |
Overall dimension (mm) (LxWxH) | 918 x 792 x 1459 |
Note:
The electric circuit diagram and parameters on the product name plate are
final ones if they have been changed.
The design might be improved without notice.
If the supply cord is damaged, it must be replaced by the manufacturer, its
service agent or similarly qualified persons in order to avoid a hazard.
WARNING:
Refrigerant is facility burning of R290, please protect against fire.
Meaning of crossed out wheeled dustbin:
Do not dispose of electrical appliances as unsorted municipal waste, use
separate collection facilities.
Contact your local government for information regarding the collection systems
available.
If electrical appliances are disposed of in landfills or dumps, hazardous
substances can leak into the groundwater and get into the food chain, damaging
your health and well-being.
When replacing old appliances with new ones, the retailer is legally obligated
to take back your old appliance for disposals at least free of charge.
UK
Access to professional repair, such as internet webpages, addresses, contact
details.
Model no: OFC390B
Aftersales service station list:
Address| Linåvej 20 . 8600 Silkeborg . Denmark| QR code|
---|---|---|---
Contact Number| 0045 7242 5571
Website| www.scandomestic.dk
Relevant information for ordering spare parts, directly or through other
channels provided by the manufacturer, importer or authorised representative;|
www.scandomestic.dk
The minimum period during which spare parts, necessary for the repair of the
appliance, are available; (years)| 8
defined in Regulation EU 2019/2018 by means of a weblink that links to the
model information as stored in the product database or a link to the product
database and information on how to find the model identifier on the product.)|
www.scandomestic.dk
**** CE declaration of conformity
This appliance has been manufactured to the strictest standards and complies
with all applicable legislations, Low Voltage Directive (LVD) and
Electromagnetic Compatibility (EMC).
UKCA declaration of conformity
This appliance has been manufactured to the strictest standards and complies
with all applicable legislation.
Scandomestic A/S · DK-8600 Silkeborg · Tel.: + 45 7242 5571 · www.scandomestic.dk
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>