scandomestic OFC390B Professional Coolers User Manual

June 16, 2024
scandomestic

scandomestic logo

OFC390B
User manual

Operation instructions

Thank you for choosing and purchasing our product. Please carefully read the operation instructions before use for a correct application and satisfactory effect.
This appliance compliance with the requirement of directive 2006/42/EC.

General

This product is a type of chilling cabinet, which is our new development of refrigeration combining the advanced technologies from both and abroad on the basis of food cabinet standards and corporate criteria. Its main kits and key components are all good brands, either and streamlined design, the product integrates the actual market demand in structural design, which better cater to the ergonomics requirements of consumers. This series applies mainly to displaying and selling of drinks, dairy products, vegetables and fruits.

Structure and Parts

scandomestic OFC390B Professional Coolers - Structure and
Parts

Handle and placement
Handle with care
Unplug the wall socket first.
Never tilt it over 45 degree during handling
Dry place
Always locate the refrigerator at a dry place.
Sufficient space
The distance from both sides and back of refrigerator to wall or other substance must not less than 10cm. The refrigeration capability might be decreased if its surround space is too small to circulate air.
Well ventilation
Always locate the refrigerator at a place with fine ventilation. For the first time use, wait for 2 hours after handling and then plug the wall socket and start it.
Far from heat source
Never place the refrigerator directly under the sunshine. Never locate it nearby any heat source or heater to prevent it from reducing refrigeration capability.
No heavy load
Never put any heavy load on the top of the refrigerator.
No hole making
Never make hole on the refrigerator. Never install other matter on the refrigerator.
Stable location
To avoid the unexpected noise and vibration, Unpacking and locate the refrigerator on a flat and solid place.

Preparation and Power Supply

Power socket
Normally, the power supply should be 220-240V, single phase AC with exclusive single phase three pin receptacle (250V 10A) and fuse (6A). The power receptacle must have a reliable earth connection.

No share on socket
Never let the refrigerator share the common socket with other appliance, otherwise the cable becomes hot and fire might be resulted.
Protect cables
Never break or damage the cables otherwise current leakage and fire might be resulted.
No water flushing
Never give the refrigerator surface a flush otherwise current leakage might be resulted.
Prevent from flammables and explosive
Never put any flammable or explosive inside the refrigerator such as ether, gasoline, alcohol, adhesive and explosive. Never put dangerous product nearby the refrigerator.
No spray
To s p ray the flammables such as paint or coating nearby the refrigerator is not allowed, otherwise fire might be resulted
After power break
After power break or unplugging the refrigerator, always wail at least 5 minutes and then you may plug the refrigerator and start it again.
No medicine
No medicine is allowed to keep inside the refrigerator.

Use and Caution

Before use:
Plug the refrigerator on 220-240V~ exclusive socket.
After the refrigerator running, put hand on the air suction to confirm it is sufficient cold. Then you may put food inside the cold box.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
This operation manual is not suitable for the persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge.

Digital temperature controller

Control
It is a mini-sized and integrated intelligent controller and applicable to the compressor of one Hp.
The main functions are:

  • Temperature display
  • Temperature control
  • Manual, automatic defrost by burning off
  • Illumination Control
  • Value Storing
  • Self Testing
  • Parameter Locking

Front Panel Operation
Set temperature
Press “SET“ button, the set temperature is displayed.
Press “UP“ or “DOWN” button to modify and store the displayed value.
Press “SET“ button to exit the adjustment and display the cold-room temperature.
If no more button is pressed within 10 seconds, the cold-room temperature will be displayed.
Illumination: press “LIGHT” button, it light; Press again, it stop.
Manual start/stop defrost: press the “LIGHT” button and hold for 6 seconds to defrost or stop defrost.
Refrigerant LED: During refrigeration, the LED is on; When the cold room temp. is constant, the LED is off; During the delay start, the LED flashes.
Defrost LED: during defrosting, the LED is on; When is stops defrosting, the LED is off, During the delay display of defrost, the LED flashes.
Digital controller reset
When display shows “Disorder”, press “DOWN” button for 2s until buzzer rings, quickly press “UP” button for 6s until buzzer rings again, the display will flash for 3s and it restores factory setting.

Cautions

If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
Never block the air suction and outlet. Keep air circulation and refrigeration capability.
Do not make food congested as it will influence the cooling effect. Adjust the rack height for proper food storage.
Cool the hot food down to room temperature before you put it into the refrigerator.
Try to pull down the curtain and keep refrigerator inside cold in case the power is cut off.
Never touch compressor to avoid from scald.
During normal operation, the emission noise level does not exceed 70 dB(A).
The maximum loading of the Shelf does not exceed 18 kg.
The climatic class of the appliance is 6, the units are suggested to be used at 16°C – 27°C ambient temperature.
To avoid damages or other problems, this product cannot be put or stored with any corrosive food.

Maintenance

Cabinet cleaning.
The product should be cleaned once a week with power supply disconnected. When cleaning, please use mild rinsing water or non-corrosive essence. Do not wash it directly with a water hose.
Cleaning for filter
To keep the device in good working condition, the condenser should be cleaned every 1 months.
Message “EE4” appearing on the display, please clean the condenser immediately.
After cleaning, if message “EE4” appearing again, please contact your after service.
Instructions for Cleaning

scandomestic OFC390B Professional Coolers - Instructions for
Cleaning Before beginning with cleaning filter, please make sure the device has been disconnected from power socket.
Remove 2 screws from the top of the front grill, see drawing
A. After the screws are loose, please take off the bottom front panel, see drawing
B. Remove the dust with wire brushes or high pressure cleaner. Leaking check.
Observe all connectors and welding joints for oil stain, which indicates a must for patching measures or call for professionals.
Frequently observe the operation of the product, in case of any abnormal noise, smell or smog, cut off the power supply immediately and call for professionals for help. Do not restart the product before trouble is cleared.
We will not be responsible for any accident incurred by failures of following the notices.

Trouble Shooting

No Troubles Causes Solutions
1 Strange noise under the bottom shelf Fan blade broken Power off and fix

the blade
2| Non-refrigerating in spite of normal operation| Unit off. Melting process Refrigerant leaking Unit failure| Power on Stop melting Patch the leak and refill  refrigerant Call for professionals
3| Weak air from air curtain, and higher cabinet temperature| Evaporator blocked by frost Inside fan damaged Too low set point of temperature controller Vent blocked by storage| Increase melting frequency Replace the fan Adjust the set point Remove the storage
4| Normal air curtain, but higher cabinet temperture| Insufficient refrigerant Too high set point of temperature controllers The wind curtain disturbed by strong air flow  Ambient temperature or humidity beyond standards| Refill the refrigerant Adjust the set point for the  temperature controller Removing the disturbing factors  Improve the conditions
5| Melting water overflown| Heating pipe for melting water damaged Water-level controller failure Ambient temperature or humidity beyond standards| Replace the heating pipe Replace the water-level  controller Improve the conditions
6| Normal air curtain, but Periodical fluctuation of cabinet temperature| Condenser contaminated Poor venting of the unit Heat protection of compressor failure Capillary is blocked by ice Temperature controller failure| Clean the condenser Improve the venting conditions  Replace the heat protection Replace the drying filter  Replace the temperature controller

Note
Following phenomena are not troubles
The murmur of water is heard when the refrigerator is working. It is a normal phenomenon as the coolant is circulating in the system.
In wet season, condensation might be found on the outside of the refrigerator. It is not a trouble, which is caused by high humidity. Simply use cloth to wipe it.
Principle of Refrigeration System

scandomestic OFC390B Professional Coolers - Principle of Refrigeration
System The principle of compression refrigeration consists of “compression”, “condensation”, “throttling” and “vaporization”. The compression is undertaken by compressor, the condensation is completed by condenser, the throttling valve is executed by capillary and the vaporization is implemented by evaporator. When the coolant is circulating in the closed refrigeration system, the compressor sucks coolant, which has absorbed the heat in evaporator, the coolant becomes a high pressure and high temperature gas. In  condenser, it dissipates heat in air, while the coolant is reliquefied and throttled in capillary and then enters into evaporator with low pressure. The liquefied coolant quickly boils and vaporizes into gas when the pressure suddenly drops. Meanwhile, it absorbs heat inside the refrigerator. And the compressor sucks the low pressure and low temperature gaseous coolant, it is circulating in this way up to realization of intended refrigeration.

Circuit Diagram

scandomestic OFC390B Professional Coolers - Circuit
Diagram

Major Parameters

Coolant and injection quantity (g) R290 (148)
General Rated input power (W) 1300
Power running of electrical heating element (W) 490
Max. ambient temp. /RH <27°C / 70%
Refrigeration Temperature (°C) 2-10
Rated voltage (V) 220-240
Rated frequency (Hz) 50
Rated current (A) 6.7
Type of Climate 6
Foaming agent Cyclopentane
Net weight (kg) 130.5
Lamp power (W) 2.5 x 2 (LED)
Total effective volume (L) 320
Overall dimension (mm) (LxWxH) 918 x 792 x 1459

Note:
The electric circuit diagram and parameters on the product name plate are final ones if they have been changed.
The design might be improved without notice.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.

WARNING:
Refrigerant is facility burning of R290, please protect against fire.
Meaning of crossed out wheeled dustbin:
Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities.
Contact your local government for information regarding the collection systems available.
If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being.
When replacing old appliances with new ones, the retailer is legally obligated to take back your old appliance for disposals at least free of charge.

UK
Access to professional repair, such as internet webpages, addresses, contact details.
Model no: OFC390B
Aftersales service station list:

Address| Linåvej 20 . 8600 Silkeborg . Denmark| QR code|
---|---|---|---
Contact Number| 0045 7242 5571
Website| www.scandomestic.dk
Relevant information for ordering spare parts, directly or through other channels provided by the manufacturer, importer or authorised representative;| www.scandomestic.dk
The minimum period during which spare parts, necessary for the repair of the appliance, are available; (years)| 8
defined in Regulation EU 2019/2018 by means of a weblink that links to the model information as stored in the product database or a link to the product database and information on how to find the model identifier on the product.)| www.scandomestic.dk

**** CE declaration of conformity
This appliance has been manufactured to the strictest standards and complies with all applicable legislations, Low Voltage Directive (LVD) and Electromagnetic Compatibility (EMC).
UKCA declaration of conformity
This appliance has been manufactured to the strictest standards and complies with all applicable legislation.

scandomestic logo

Scandomestic A/S · DK-8600 Silkeborg · Tel.: + 45 7242 5571 · www.scandomestic.dk