AROHA SM11R4 Interconnected Smoke Detector User Guide

June 9, 2024
AROHA

AROHA SM11R4 Interconnected Smoke Detector

Product Profile

AROHA SM11R4-Interconnected-Smoke-Detector-fig-
\(1\)`

Package content

CAUTION:

  1. Before mounting the smoke detector, please active the smoke detector first.
  2. Please test the smoke detector at least once a month.

Thank you for purchasing our smoke alarm device. Please read this manual carefully to ensure proper use and store it in a safe place for future reference.

Application

AROHA SM11R4-Interconnected-Smoke-Detector-fig-
\(3\)

Product Specifications

  • Power : 3V DC
  • Battery Package : CR14505,Lithium Battery,1600mAh(Included)
  • Operation Current : <30uA (standby); <70mA (alarm)
  • Alarm Volume : >85 dB(A) at 3 meters
  • Alarm Sensitivity : 0.09 – 0.17 dB/m
  • Low Battery : 2.6 ± 0.1 V
  • Frequency : 433.92MHz
  • Working distance : Up to 100m (Outdoor)
  • Max interlinked devices : 30pcs per group
  • Silence Time: approx. 10 minutes
  • Comply to Standard EN14604:2005/AC:2008

Packing List

  • 1 × Photoelectric smoke detector
  • 1 × Mounting bracket
  • 1 × Screw Kit
  • 1 × User manual

Feature

  • 10 years, not replaceable
  • silence mode
  • Alarm volume >85dBa
  • Interconnected
  • 1008 DOP: INV-SM11R-Rev0 Comply to Standard EN14604:2005/AC:2008

Installation instructions

AROHA SM11R4-Interconnected-Smoke-Detector-
fig- \(4\)

  1. Check figure 1, 2 and 3 for correct installation locations.
  2. Smoke, heat and burning things will spread horizontally after rising to the ceiling, so install the alarm in middle of the ceiling.
  3. If the length of the room or the hall is beyond 10 meters, you need to install multiple alarms.

Don’t install on these locationsAROHA SM11R4-Interconnected-Smoke-
Detector-fig- \(5\)

  1. High-humidity areas such as kitchens and bathrooms.
  2. Next to air outlets, fans and central heating.
  3. Dusty, dirty areas or areas with insects.
  4. High-temperature and easily polluted places.
  5. Places with difficult access, making it difficult to operate the test function.
  6. Within 1.5 meters from lamps.
  7. Next to doors or windows.
  8. In the top of rooms with sloping roofs, the corner of the room or other deadair spaces.

Mounting the smoke detector

  1. Twist off the mounting bracket from the smoke detector.
  2. Put the bracket on the installation position and mark the 2 screw holes.
  3. Drill two 5mm mounting holes and insert two plastic anchor plugs by hammer.
  4. Screw the mounting bracket to the ceiling or the wall.
  5. Attach the smoke detector to the mounting bracket and turn clockwise to lock the alarm.

CAUTION

  1. The installation instructions must be followed strictly to avoid unsafe conditions.
  2. Do not paint your smoke detector.
  3. The battery cannot be replaced; do not try to replace the battery.

Activate and deactivate the device

The device is deactivated by default before leaving the factory. Before the device can be used normally, the product must be activated.
Activate: Press the test button over 10 seconds until the red LED indicator lights up. After you release the test button the smoke detector is activated and can be used.
Deactivate: Press the test button over 10 seconds until the red LED indicator blinks twice. After you release the test button the smoke detector is deactivated and cannot be used.

How to link the smoke alarms

  • Step 1 : Press the test/silence button on one of the smoke alarms 4 times. The smoke detector enters transmitting mode for 60sec and the green LED will rapidly flash.
  • Step 2 : Press the test/silence button on the other smoke alarms twice. The green LED will slowly flash, indicating receiving mode.
  • Step 3 : If pairing is successful, the green LED on the receiving alarms will stop flashing. When there is an error the green light will continue to flash for 60 seconds followed by a red light for 2 seconds.

How to unlink a smoke alarm

Press the test/silence button on the smoke alarm twice and the green LED will slowly flash for 60 seconds (receiving mode). After this period, it will stop flasing and the smoke alarm is unlinked.

Test your alarm

Test the unit to ensure proper operation by pressing the cover. The alarm will sound if the unit is working well. If there is no sound, refer to the “Trouble shooting” section.

CAUTION:

  1. DO NOT test your smoke detector using an open flame. This may damage the smoke alarm or ignite combustible materials and start a structural fire.
  2. DO NOT stand close to the smoke detector when the alarm is sounding. Exposure at close range may be harmful to your ears.
  3. Monthly test: test this smoke detector once a month.

LED Indicators

  1. Normal status: Green LED Flashes once every 60 seconds.
  2. Test status: Red LED flashes once every second.
  3. Hush/Silence mode: Red LED flashes once every 8 seconds.
  4. Low battery status: Red LED flashes once every 60 seconds and 1 beep every 60 seconds.
  5. Fault status: the alarm will beep every 40 seconds.

Silence Mode

When the smoke detector is going off you can push the test button to pause it for approx. 10 minutes. During this silence mode the red LED will flash once every 8 second. The silence feature is only to be used when the source of the alarm is known and safe. The smoke detector will automatically reset after approximately 10 minutes.

CAUTION:
Before using the smoke detectors silence mode, identify the source of the smoke and be certain a safe condition exists.

Maintenance and Cleaning

There are a few simple steps you need do to keep it working properly:

  1. Test the smoke detector once a month.
  2. Do not paint the smoke detector. Paint will seal the vents and interfere with the sensor’s ability to detect smoke.
  3. Never attempt to disassemble the smoke detector to clean inside. This will damage the alarm.
  4. Clean the smoke detector at least once a month to remove dust, dirt or debris. Use a vacuum cleaner with a soft brush and vacuum all sides and covers of the smoke detector.

Trouble Shooting

Problem Method of disposal
The smoke detector does not sound when testing Please check whether the smoke

detector is activated.
Red LED flashes and the smoke detector delivers one beep every 60

seconds

| The battery is low.
The smoke detector delivers one beep every 40 seconds| 1.  Clean the smoke detector, please refer to

the “maintenance and cleaning” section.

2.  The alarm is malfunctioning. Contact the retailer to replace it if the warranty is still in

place.

Nuisance alarms triggered intermittently or when residents are cooking, taking showers, etc.| 1.  Press test button to put smoke detector in silence mode.

2.  Clean the smoke detector. Please refer to

the “maintenance and cleaning” section.

3.  Move the smoke detector to a new location.

Warranty Information

  • Each smoke detector has to be free from defects in material and workmanship under normal use and service for a period of 2 years from the date of purchase. During the specified warranty period, we will repair or replace any defective smoke detector that is returned. Please contact us at invisionretail@gmail.com and include your name, address, phone number and order number along with a brief description of what is wrong with the unit.
  • Damage from neglect, abuse or failure to adhere to any of the enclosed instructions will result in termination of the warranty, and the unit will not be replaced or repaired.
  • This warranty shall not apply to the smoke detector if it has been damaged, modified, abused or altered after the date of purchase or if it fails to operatedue to improper maintenance.
  • The manufacturer shall have no liability for any personal injury, property damage or any special, incidental, contingent or consequential damage of any kind resulting from gas leakage, smoke, fire or explosion

Manufacturer : Invision Retail Postbus 135 4900AC Oosterhout The Netherlands

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals