CHAMPION POWER EQUIPMENT 201161 12000W Tri Fuel Portable Generator Instruction Manual

September 19, 2024
CHAMPION POWER EQUIPMENT

201161 12000W Tri Fuel Portable Generator

“`html

Specifications

  • Generator Specifications: 12,000W

  • Engine Specifications: Tri-Fuel

  • Oil Specifications: Refer to manual for recommended oil
    type

  • Fuel Specifications: Gasoline, Propane (LPG), Natural Gas
    (NG)

  • Battery Specifications: Refer to manual for battery
    requirements

  • Temperature Specifications: Refer to manual for operating
    temperature range

Product Usage Instructions

Assembly

To set up the generator, follow these steps:

  1. Install the Wheel Kit according to the instructions
    provided.

  2. Connect the Battery as per the manual guidelines.

  3. Add Engine Oil as recommended in the manual.

  4. Add Fuel:

    • Gasoline: Follow the instructions for adding gasoline.
    • Propane (LPG): Follow the instructions for adding propane.
    • Natural Gas (NG): Follow the instructions for adding natural
      gas.
  5. Ensure proper Grounding of the generator.

Operation

To operate the generator safely:

  1. Read the Operator’s Manual thoroughly before starting the
    generator.

  2. Keep the generator outside and away from doors, windows, and
    garages to prevent carbon monoxide build-up.

  3. Point fumes away from nearby people for safety.

  4. If you experience any symptoms of carbon monoxide poisoning,
    leave the area immediately.

Maintenance

Regular maintenance is essential for the longevity of your
generator. Refer to the manual for detailed maintenance
procedures.

Storage

Proper storage of the generator is crucial for its performance.
Follow the storage guidelines provided in the manual.

FAQ

Q: How do I register my product warranty?

A: You can activate your warranty by registering your product on
championpowerequipment.com or visiting their website.

Q: What fuel types can be used with this generator?

A: The generator is compatible with Gasoline, Propane (LPG), and
Natural Gas (NG). Follow the instructions for adding each type of
fuel.

Q: How can I ensure safety while using the generator?

A: Always keep the generator outside, away from living spaces,
and point fumes away from people. Familiarize yourself with carbon
monoxide risks and symptoms.

“`

OPERATOR’S MANUAL
MODEL #201161 12,000W TRI-FUEL PORTABLE GENERATOR

ACTIVATE YOUR WARRANTY
by registering your product: championpowerequipment.com

SERIAL NO.

or visit championpowerequipment.com
SAVE THESE INSTRUCTIONS. This manual contains important safety precautions which should be read and understood before operating the product. Failure to do so could result in serious injury. This manual should remain with the product. Specifications, descriptions and illustrations in this manual are as accurate as known at the time of publication, but are subject to change without notice. This product meets the requirements of the PGMA (Portable Generator Manufacturers’ Association) standard ANSI/PGMA G300-2018 (Safety and Performance of Portable Generators). Covered by one or more of the following U.S. Patent Numbers: #10,862,414, 10,697,379, 11,008,958 and other U.S. and foreign patents pending.

4056-M-OP REV 20240628 EN

Champion Power Equipment, Inc.

CARBON MONOXIDE KILLS

CARBON MONOXIDE SAFETY: THE BIG PICTURE
As the only safe way to use a portable generator, taking your generator outside is absolutely mandatory to keep your family safe from carbon monoxide. But there’s even more you can do. By educating yourself about all carbon monoxide risks, you’ll be better prepared to protect your family from this colorless, oderless threat.

ALWAYS READ MANUAL THE OPERATOR’S
MANUAL FIRST

KNOW THE SYMPTOMS

· Headache

· Dizziness

· Nausea

· Fatigue

· Shortness of breath

STAY ALERT WITH CARBON MONOXIDE DETECTORS

KEEP IT OUTSIDE AND AWAY FROM DOORS, WINDOWS, AND GARAGES

IF YOU FEEL SYMPTOMS, LEAVE RIGHT AWAY

POINT FUMES AWAY FROM NEARBY PEOPLE

www.TakeYourGeneratorOutside.com

201161 – 12,000W TRI-FUEL PORTABLE GENERATOR

TABLE OF CONTENTS

TABLE OF CONTENTS
Introduction…………………………………………… 4 Safety Definitions …………………………………… 4 Important Safety Instructions ………………….. 5
Fuel Safety ……………………………………………….. 7 Safety and Dataplate Labels……………………………….. 9 Safety Symbols…………………………………………… 10 Operation Symbols ……………………………………….. 11 Quick Start Label Symbols………………………………… 12
Controls and Features …………………………… 13
Generator ………………………………………………… 13 Control Panel …………………………………………….. 14 Fuel Select Dial…………………………………………… 14 Intelligauge with Power Meter …………………………….. 15 Industry Canada: CAN ICES-002/NMB-002 ……………….. 16 Parts Included ……………………………………………. 16
Assembly …………………………………………….. 17
Install the Wheel Kit………………………………………. 17 Connect the Battery………………………………………. 17 Add Engine Oil……………………………………………. 17 Add Fuel: Gasoline ……………………………………….. 19 Add Fuel: Propane (LPG) ………………………………….. 20 Add Fuel: Natural Gas (NG) ……………………………….. 21 Grounding ……………………………………………….. 21
Operation …………………………………………….. 21
CO Shield® – Carbon Monoxide (CO) Detection and Auto-shutoff System …………………………………. 21 Generator Location……………………………………….. 23 Surge Protection …………………………………………. 23 Starting the Engine: Gasoline……………………………… 23 Starting the Engine: Propane (LPG) ……………………….. 24 Starting the Engine: Natural Gas (NG)……………………… 25 Battery…………………………………………………… 26 Connecting Electrical Loads ………………………………. 27 Do Not Overload Generator ……………………………….. 27 GFCI……………………………………………………… 27 Stopping the Engine………………………………………. 28 Moving the Generator …………………………………….. 28 Operation at High Altitude ………………………………… 29

Maintenance ………………………………………… 29
Cleaning the Generator …………………………………… 29 Changing Engine Oil and Filter…………………………….. 29 Cleaning and Adjusting the Spark Plugs ………….. ………. 30 Cleaning the Air Filter ……………………………. ………. 30 Cleaning the Spark Arrestor ………………………………. 30 Replacing Fuel Filter ……………………………………… 31 Adjusting the Governor…………………………… ………. 31 Generator Battery ……………………………….. ………. 31 Maintenance Schedule…………………………… ………. 32
Storage ……………………………………………….. 32
Short Term Storage (30 days ­ 1 year)…………………….. 32 Long Term Storage (over 1 year) …………………. ………. 33 LPG Storage ……………………………………………… 33 NG Storage ………………………………………………. 33 Removing from Storage: Gasoline …………………………. 33 Removing from Storage: Propane (LPG)……………………. 33 Removing from Storage: Natural Gas (NG) …………………. 33
Specifications………………………………………. 34
Generator Specifications………………………………….. 34 Engine Specifications ……………………………. ………. 34 Oil Specifications…………………………………………. 34 Fuel Specifications ………………………………. ………. 34 Battery Specifications……………………………. ………. 35 Temperature Specifications……………………………….. 35
Troubleshooting……………………………………. 36

FOR PARTS BREAKDOWN

Search by model number at championpowerequipment.com

3

201161 – 12,000W TRI-FUEL PORTABLE GENERATOR
INTRODUCTION
Congratulations on your purchase of a Champion Power Equipment (CPE) product. CPE designs, builds, and supports all of our products to strict specifications and guidelines. With proper product knowledge, safe use, and regular maintenance, this product should bring years of satisfying service.
Every effort has been made to ensure the accuracy and completeness of the information in this manual at the time of publication, and we reserve the right to change, alter and/or improve the product and this document at any time without prior notice.
CPE highly values how our products are designed, manufactured, operated, and serviced as well as providing safety to the operator and those around the generator. Therefore, it is IMPORTANT to review this product manual and other product materials thoroughly and be fully aware and knowledgeable of the assembly, operation, dangers and maintenance of the product before use. Fully familiarize yourself, and make sure others who plan on operating the product fully familiarize themselves too, with the proper safety and operation procedures before each use. Please always exercise common sense and always err on the side of caution when operating the product to ensure no accident, property damage, or injury occurs. We want you to continue to use and be satisfied with your CPE product for years to come.
When contacting CPE about parts and/or service, you will need to supply the complete model and serial numbers of your product. Transcribe the information found on your product’s nameplate label to the table below
CPE TECHNICAL SUPPORT TEAM
1-877-338-0999
MODEL NUMBER
201161
SERIAL NUMBER

INTRODUCTION
SAFETY DEFINITIONS
The purpose of safety symbols is to attract your attention to possible dangers. The safety symbols, and their explanations, deserve your careful attention and understanding. The safety warnings do not by themselves eliminate any danger. The instructions or warnings they give are not substitutes for proper accident prevention measures.
DANGER
DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury.
WARNING
WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION
CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
NOTICE
NOTICE indicates information considered important, but not hazard-related (e.g., messages relating to property damage).

DATE OF PURCHASE

PURCHASE LOCATION

4

201161 – 12,000W TRI-FUEL PORTABLE GENERATOR
IMPORTANT SAFETY INSTRUCTIONS
WARNING
Cancer and Reproductive Harm ­ www.P65Warnings.ca.gov
DANGER
Generator exhaust contains carbon monoxide, a colorless, odorless, poisonous gas. Breathing carbon monoxide will cause nausea, dizziness, fainting or death. If you start to feel dizzy or weak, get to fresh air immediately.
OPERATE GENERATOR OUTDOORS ONLY IN A WELL VENTILATED AREA AND POINT EXHAUST AWAY. DO NOT operate the generator inside any building, including garages, basements, crawlspaces and sheds, enclosure or compartment, including the generator compartment of a recreational vehicle. DO NOT allow exhaust fumes to enter a confined area through windows, doors, vents or other openings.
DANGER
Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell.
NEVER use inside a home or garage, EVEN IF doors and windows are open. ONLY use OUTSIDE and far away from windows, doors, and vents.

IMPORTANT SAFETY INSTRUCTIONS
WARNING
Always install a battery-operated Carbon Monoxide (CO) detector on each level of any building or home dwelling adjacent to the generator location following the Carbon Monoxide (CO) detector manufacturer’s installation instructions. In many U.S. States and Canadian Provinces, it is required by law to have a Carbon Monoxide (CO) detector installed on each level of an occupied building or home dwelling. The Carbon Monoxide (CO) detector is a device that detects elevated levels of poisonous Carbon Monoxide (CO) gas and will alert the occupants by flashing a visual light indicator and an audible alarm. The Carbon Monoxide (CO) detector alarm will not sense smoke, fire, or any other poisonous gas other than carbon monoxide.
Carbon Monoxide (CO) detectors located only in living spaces.
WARNING
Smoke alarms cannot detect Carbon Monoxide (CO) gas. To better educate yourself about all carbon monoxide risks, go to www.takeyourgeneratoroutside.com
DANGER
Tampering with the CO Shield® system will result in a hazardous condition and will void your warranty. Removing the CO Shield® module will not allow the generator to start.

5

201161 – 12,000W TRI-FUEL PORTABLE GENERATOR
DANGER
Operate equipment with guards in place. Rotating parts can entangle hands, feet, hair, clothing and/or accessories. Traumatic amputation or severe laceration can result.
Keep hands and feet away from rotating parts. Tie up long hair and remove jewelry. DO NOT wear loose-fitting clothing, dangling drawstrings or items that could become caught.
DANGER
Generator produces powerful voltage.
DO NOT touch bare wires or receptacles. DO NOT use electrical cords that are worn, damaged or frayed. Use only Champion electrical cords for proper application. DO NOT operate generator in wet weather. DO NOT allow children or unqualified persons to operate or service the generator. Use a ground fault circuit interrupter (GFCI) in damp areas and areas containing conductive material such as metal decking. Connection to your home’s electrical system requires a listed 30A transfer switch installed by a licensed electrician and approved by the local authority having jurisdiction. The connection must isolate the generator from the utility power and must comply with all applicable laws and electrical codes.
WARNING
Do not use generator for medical life support uses.
In case of emergency, call 911 immediately. NEVER use this product to power life support devices or life support appliances. Inform your electricity provider immediately if you or anyone in your household depends on electrical equipment to live. Inform your electrical provider immediately if a loss of power would cause you or anyone in your household to experience a medical emergency.

IMPORTANT SAFETY INSTRUCTIONS
WARNING
Spark from removed spark plug wire can result in fire or electrical shock. When servicing the generator: Disconnect the spark plug wire and place it where it cannot contact the plug or any other metal object. DO NOT check for spark with the plug removed. Use only approved spark plug testers.
WARNING
Running engines produce heat. Severe burns can occur on contact. Combustible material can catch fire on contact.
DO NOT touch hot surfaces. Avoid contact with hot exhaust gases. Allow equipment to cool before touching. Maintain at least 3 ft. (91.4 cm) of clearance on all sides to ensure adequate cooling. Maintain at least 5 ft. (1.5 m) of clearance from combustible materials.
WARNING
Rapid retraction of the recoil cord will pull hand and arm towards the engine faster than you can let go. Broken bones, fractures, bruises or sprains could result. Unintentional startup can result in entanglement, traumatic amputation or laceration.
When starting engine, pull the recoil cord slowly until resistance is felt and then pull rapidly to avoid kickback. DO NOT start or stop the engine with electrical devices plugged in and turned on.
WARNING
Although the generator contains a spark arrester, maintain a minimum distance of 5 ft. (1.5 m) from dry vegetation to prevent fires.
CAUTION
Exceeding the generator’s running capacity can damage the generator and/or electrical devices connected to it.
DO NOT overload the generator. DO NOT tamper with the governed speed. DO NOT modify the generator in any way.

6

201161 – 12,000W TRI-FUEL PORTABLE GENERATOR
CAUTION
Start the generator and allow the engine to stabilize before connecting electrical loads. Connect electrical equipment in the off position, and then turn them on for operation. Turn electrical equipment off and disconnect before stopping the generator.
CAUTION
Improper treatment or use of the generator can damage it, shorten its life or void the warranty.
Use the generator only for intended uses. Operate only on level surfaces. DO NOT expose generator to excessive moisture, dust, or dirt. DO NOT allow any material to block the cooling slots. If connected devices overheat, turn them off and disconnect them from the generator. DO NOT use the generator if: ­ Electrical output is lost ­ Equipment sparks, smokes or emits flames ­ Equipment vibrates excessively
Fuel Safety
DANGER
GASOLINE, GASOLINE VAPORS, PROPANE AND NATURAL GAS ARE HIGHLY FLAMMABLE AND EXPLOSIVE
Fire or explosion can cause severe burns or death.
Gasoline and gasoline vapors: ­ Gasoline vapors are highly flammable and explosive. ­ Gasoline vapors can cause a fire or explosion if ignited. ­ Gasoline is a liquid fuel and the resulting gasoline vapors can
ignite and cause a fire or explosion. ­ Gasoline is a skin irritant and needs to be cleaned up
immediately if spilled on skin or clothes. ­ Gasoline has a distinctive odor, this will help detect potential
leaks quickly. ­ In any petroleum gas fire, flames should not be extinguished
unless by doing so the fuel supply valve can be turned OFF. This is because if a fire is extinguished and a supply of fuel is not turned OFF, then an explosion hazard could be created.

IMPORTANT SAFETY INSTRUCTIONS
­ Gasoline vapors expand and contract with ambient temperatures. Never fill the gasoline tank past the red FULL indicator on the fuel filter, as gasoline vapors needs room to expand if temperatures rise.
DANGER
Propane/LPG (liquified petroleum gas) and LPG Vapors: ­ LPG is a hydrocarbon gas that exists in a liquified form and
it’s vapors are highly flammable and explosive. ­ LPG and it’s vapors are under pressure and can cause a
fire or explosion if ignited. ­ LPG vapors are heavier than air and will settle in low
places while dissipating. ­ LPG itself is odorless and tasteless. For safety, a chemical
is added to give it an odor to help detect leaks quickly. ­ If a leak is detected, IMMEDIATELY turn OFF the gas
supply. ­ In the event of an LPG fire and only when safe to do so,
first close the regulator valve OFF and then use a dry powder extinguisher to put out the fire. This is because if a fire is extinguished before the regulator valve is closed OFF, then an explosion hazard condition could be created. ­ Always keep the LPG cylinder in an upright position. ­ LPG is a skin irritant and can cause severe cold burns similar to frostbite. ­ Always wear proper protective gloves when connecting to and disconnecting from a propane bottle. ­ Always keep LPG away from sparks, open flames, pilot lights, heat and other sources of ignition.
DANGER
NG (natural gas) and NG Vapors: ­ NG vapors are highly flammable and explosive. ­ NG vapors can cause a fire or explosion if ignited. ­ NG itself is odorless and tasteless. For safety, a chemical
is added to give it an odor to help detect leaks quickly. ­ NG is lighter than air and will collect in higher areas. ­ If a leak is detected, IMMEDIATELY turn OFF the gas
supply.

7

201161 – 12,000W TRI-FUEL PORTABLE GENERATOR
WARNING
When adding or removing gasoline: DO NOT light or smoke cigarettes. Always stop the engine and allow to cool for a minimum of two minutes before refueling. Always loosen gasoline cap slowly to release vapor pressure and to keep fuel from escaping around the gasoline cap. Always replace and tighten the gasoline cap securely after fueling. Never remove the gasoline cap or add gasoline while the engine is running or when the engine is hot. Only fill or drain gasoline outdoors in a well-ventilated area. DO NOT pump gasoline directly into the generator at the gas station. Always store gasoline in an EPA/CARB compliant container or to transfer the gasoline to the generator. DO NOT overfill the gasoline tank. Always keep gasoline, propane and natural gas vapors away from sparks, open flames, pilot lights, heat and other sources of ignition.
WARNING
When starting the generator: DO NOT attempt to start a damaged generator. Always check that the gasoline cap, air filter, spark plug, fuel lines and exhaust system are properly in place. Always allow spilled gasoline to evaporate fully before attempting to start the engine. Always check the connections of the supply hose for leaks before using LPG or NG fuel. Always be certain that the generator is resting firmly on level ground.
WARNING
When operating the generator: DO NOT move or tip the generator during operation.

IMPORTANT SAFETY INSTRUCTIONS
WARNING
When transporting or servicing the generator: Always check that the fuel valve is in the OFF position and the gasoline tank is empty. Always check that the LPG or NG supply hose is disconnected and stored securely away from the generator after use. Disconnect the spark plug wire.
WARNING
When storing the generator: Always store away from sparks, open flames, pilot lights, heat and other sources of ignition. Never store generator, gasoline or LPG cylinders near furnaces, water heaters, or any other appliances that produce heat or have automatic ignitions.
DANGER
NEVER place a gasoline container, gasoline tank, LPG cylinder or any combustible material in the path of the exhaust stream during operation of the engine.
WARNING
Never use a gasoline container, gasoline tank, LPG connector hose, LPG cylinder or any other fuel item that is broken, cut, torn or damaged.

8

201161 – 12,000W TRI-FUEL PORTABLE GENERATOR

IMPORTANT SAFETY INSTRUCTIONS

Safety and Dataplate Labels
These labels warn you of potential hazards that can cause serious injury. Read them carefully. If a label comes off or becomes hard to read, contact Technical Support Team for possible replacement.

D

CB

A

G

F E

Top

Back

LABEL

DESCRIPTION

A

ACTION LABEL ETIQUETA DE ACCIÓN ÉTIQUETTE D’ACTION

AUTOMATIC SHUTOFF ­ YOU MUST: APAGADO AUTOMÁTICO ­ USTED DEBE: ARRÊT AUTOMATIQUE ­ VOUS DEVEZ :

3783-L-SF

Move generator to an open, outdoor area. Point exhaust away. Don’t run generators in enclosed areas (e.g. not in house or garage).

Mover el generador a un área abierta a la intemperie. Apunte el escape alejado. No corra los generadores en áreas cerradas (ej. no en una casa o garaje).
Déplacer le générateur vers un espace extérieur en plein air. Garder l’échappement loin. Ne pas faire fonctionner les générateurs dans un espace clos (ex., pas dans une maison ou un garage).

Move to fresh air and get medical help if sick, dizzy or weak.

EXHAUST EL ESCAPE L’ECHAPPEMENT

Mueva al aire fresco y obtenga asistencia medica si está enfermo, mareado, o débil.
Aller à l’air frais et obtenir de l’aide médicale si malade, étourdi ou faible.

POINT AWAY DIRIJA ALEJADO
DIRIGER LOIN

CO Shield® Action ­ automatic shutoff
*See CO Shield® section

4990-L-SF-A

B

Safety Symbols

C

DANGER PELIGRO DANGER
Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell.

NEVER use inside a home or garage, EVEN IF doors and windows are open.

ONLY use OUTSIDE and far away from windows, doors, and vents.

El uso de un generador en interiores PUEDE MATARLO EN MINUTOS. El escape del generador contiene monóxido de carbono. Éste es un veneno que no se puede ver ni oler. NUNCA lo use dentro del hogar ni el garaje, INCLUSO SI las puertas y ventanas están abiertas. Úselo SÓLO a la INTEMPERIE lejos de ventanas, puertas, y orificios de ventilación.
Utiliser une génératrice à l’intérieur PEUT VOUS TUER EN QUELQUES MINUTES. L’échappement de la génératrice contient du monoxyde de carbone. Il s’agit d’un poison que vous ne pouvez ni voir ni sentir. Ne l’utilisez JAMAIS dans la maison ou le garage MÊME SI les portes et les fenêtres sont ouvertes. Utilisez le UNIQUEMENT À L’EXTÉRIEUR, loin des fenêtres, portes et trappes de ventilation.
3784-L-SF-B

CO Danger

D

UNLEADED FUEL ONLY. Minimum octane rating of 87. Maximum 10% ethanol.
GASOLINA REGULAR SOLAMENTE. 87 octanos como mínimo. Máximo de etanol de 10%.
ESSENCE SANS PLOMB SEULEMENT. Indice d’octane minimal de 87. Maximum 10 % d’éthanol.
1110-L-OP-B

Fuel

4049-L-PR-C 1035-L-SF-C

WARNING

ADVERTENCIA

AVERTISSEMENT

E

DO NOT TOUCH!

Operation of this equipment may create sparks that can start ¡NO TOCAR! Los gases de

La operación de este equipo puede producir chispas que pueden provocar

NE PAS TOUCHER! Les gaz Cet équipement peut créer des étincelles et provoquer un incendie dans la

Exhaust gases, muffler fires around dry vegetation. A spark arrestor may be

escape, el silenciador y los incendios alrededor de la vegetación seca. Un supresor de chispas puede que d’échappement, le silencieux végétation sèche. Un pare-étincelles peut être requis. L’utilisateur doit

and engine components required. The operator should contact local fire agencies for compnonentes del motor están sea necesario. El operador debe comunicarse con las agencias locales de

et les pièces du moteur sont communiquer avec le service d’incendie local pour connaître les lois et

Hot Surface

are extremely HOT and laws and regulations relating to fire prevention requirements. extremadamente CALIENTES y bomberos para las leyes y reglamentos relativos a los requisitos de prevención extrêmement CHAUDS et les règlements en matière de prévention des incendies. Si elle est

cause burns.

If installed, clean every 100 hours or every season.

causan quemaduras.

de incendios. Si está instalado, limpie cada 100 horas o cada temporada.

peuvent causer des brûlures. installée, nettoyez la génératrice toutes les 100 heures ou chaque saison.

CHAMPION POWER EQUIPMENT, INC. 6370 S PIONEER WAY, UNIT 101 LAS VEGAS, NV 89113 USA / É.-U. · 1-877-338-0999 WWW.CHAMPIONPOWEREQUIPMENT.COM

FREQUENCY (Hz) FRÉQUENCE (Hz)
RPM TR / MIN

60 3600

GASOLINE WATTS WATTS À ESSENCE
GASOLINE VOLTS (AC) VOLTS (C.A.) D’ESSENCE

12000 120/240

NATURAL GAS WATTS WATTS AU GAZ NATUREL
NATURAL GAS VOLTS (AC) VOLTS (C.A.) AU GAZ NATUREL

10000 120/240

F

4010077
Conforms to

MADE IN CHINA / FABRIQUÉ EN CHINE

MODEL MODÈLE

201161

PHASE PHASE

1

POWER FACTOR FACTEUR DE PUISSANCE

1.0

MAX AMBIENT TEMP. 104°F TEMP. AMBIANTE MAX. 40°C

GASOLINE AMPS (AC) AMPÈRES (C.A.) À ESSENCE
PROPANE WATTS WATTS AU PROPANE
PROPANE VOLTS (AC) VOLTS (C.A.) AU PROPANE

100/50 11000 120/240

NATURAL GAS AMPS (AC) AMPÈRES (C.A.) AU GAZ NATUREL

83.3/41.7

REGISTER TO
ACTIVATE YOUR WARRANTY

CSA C22.2 No. 100

ENREGISTREZ-VOUS POUR

Conforme à CSA C22.2 N° 100

SERIAL NO. N° DE SÉRIE

XXXXXXXXXXXX

H INSULATION CLASS
CLASSE D’ISOLATION

PROPANE AMPS (AC) AMPÈRES (C.A.) AU PROPANE

91.7/45.8

ACTIVEZ VOTRE GARANTIE

DANGER

PELIGRO

DANGER

Never position yourself underneath the generator when lifting or moving. Failure to do so could result in serious

injury or death. Always keep bystanders, children and pets at least 25 ft. (7.6 m) away when lifting the generator.

G

Nunca se coloque debajo del generador al levantar o mover. De lo contrario, podría resultar en lesiones graves o la muerte. Siempre mantenga a los transeúntes, niños y mascotas al menos a 25 ft. (7.6 m) de distancia cuando

levante el generador.

Ne vous placez jamais sous la génératrice lorsque vous le soulevez ou le déplacez. Le non-respect de cette consigne peut entraîner des blessures graves ou la mort. Tenez toujours les spectateurs, les enfants et les animaux domestiques à au moins 7,6 m (25 pi) lorsque vous soulevez la génératrice.

3678-L-SF-A

Dataplate Lifting

9

201161 – 12,000W TRI-FUEL PORTABLE GENERATOR

IMPORTANT SAFETY INSTRUCTIONS

Safety Symbols
Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to more safely operate the product.

SYMBOL

MEANING

Read Operator’s Manual. To reduce the risk of injury, user must read and understand operator’s manual before using this product.

Clearance. Keep all objects at least 5 feet (1.5m) from generator. Heat from the muffler and exhaust gas can ignite combustible objects.

Ground. Consult with local electrician to determine grounding requirements before operation.
Electric Shock. Failure to use in dry conditions and to observe safe practices can result in electric shock. Improper connections to a building can allow current to backfeed into utility lines, creating an electrocution hazard. A transfer switch must be used when connecting to a building.
Fire/Explosion. Fuel and its vapors are extremely flammable and explosive. Fire or explosion can cause severe burns or death. Keep generator at least 5 feet (1.5m) from all objects to prevent combustion.

Hot Surface. To reduce the risk of injury or damage, avoid contact with any hot surface.

Open Flame Alert. Fuel and its vapors are extremely flammable and explosive. Keep fuel away from smoking, open flames, sparks, pilot lights, heat, and other ignition sources.

Wet Conditions Alert. Do not expose to rain or use in damp locations.

10

201161 – 12,000W TRI-FUEL PORTABLE GENERATOR

IMPORTANT SAFETY INSTRUCTIONS

Operation Symbols
Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to more safely operate the product.

SYMBOL

Start

MEANING

On

Off

Gasoline On

Gasoline Off

Propane On

Natural Gas On

Propane Inlet/Natural Gas Inlet
Run. Push choke knob to “RUN” position. Choke. Pull choke knob to “CHOKE” position.
Circuit Breaker: On

Circuit Breaker: Off

SYMBOL

MEANING
Locking Receptacle Neutral Bonded to Frame. Neutral circuit IS electrically connected to the frame/ground of the generator. High CO Warning. Move generator to an open, outdoor area. Move to fresh air and get medical help if sick, dizzy or weak. CO Shield System Fault. Electrical issue, end of life.
Ground Terminal
Hertz
Volts
Run time
Output Power

Gasoline Tank: Full

Gasoline Tank: Empty

Circuit Breaker Reset: Flip

Circuit Breaker Reset: Push

11

201161 – 12,000W TRI-FUEL PORTABLE GENERATOR

IMPORTANT SAFETY INSTRUCTIONS

Quick Start Label Symbols
Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to more safely operate the product.

1

2

3

4

5

6

7

5W-30

1

2

4046-L-OP-B

Starting the Engine – Electric Start
DANGER
Move generator outside and far away from windows, doors and intake ventilation covers.
1. Check oil level. Recommended oil is 5W-30.
2. Check gasoline level. When adding gasoline, use a minimum octane rating of 87 and an ethanol content of 10% or less by volume.
3. Turn the fuel select dial to “GASOLINE ON” position. 4. Pull choke knob out to “CHOKE” position. 5. Press ignition switch to the “START” position. 6. Push choke knob in to “RUN” position. 7. Plug in desired device.

Stopping the Engine
1. Turn off and unplug all connected electrical loads. 2. Turn the fuel select dial to the “ENGINE OFF” position.
For adding fuel and starting the engine with LPG see Add Fuel: Propane (LPG) in Assembly section and Starting the Engine: Propane (LPG) in the Operation section.
For adding fuel and starting the engine with NG see Add Fuel: Natural Gas (NG) in Assembly section and Starting the Engine: Natural Gas (NG) in the Operation section.

12

201161 – 12,000W TRI-FUEL PORTABLE GENERATOR

CONTROLS AND FEATURES

CONTROLS AND FEATURES
Read this operator’s manual before operating your generator. Familiarize yourself with the location and function of the controls and features. Save this manual for future reference.

Generator

1

12

2

13

14

3 4

5

6

11
10 9

7

8

1. Fuel Cap ­ Remove to add fuel. 2. Oil Fill Cap ­ Used to fill oil. 3. Muffler 4. Support Leg 5. Dipstick ­ Used to check oil level. 6. Never Flat Wheels ­ 12 in. (30.5 cm) 7. LPG / NG Inlet – Used to connect LPG or NG fuel source to
generator. 8. Ground Terminal ­ Consult an electrician for local grounding
regulations.

9. Battery ­ Provides 12V DC power to the starting system. 10. Folding Handle ­ Used to move unit by lifting and rolling on
wheels. Do not use to lift or carry the unit. 11. Control Panel ­ See Control Panel section. 12. Gasoline Gauge 13. Gasoline Tank ­ 11 gal. (41.20 L) 14. Engine Access Cover

13

201161 – 12,000W TRI-FUEL PORTABLE GENERATOR
Control Panel

1

2

3

CONTROLS AND FEATURES

4

5

6

A

B

C

1. Ignition Switch ­ Used for electric starting of the generator.

Fuel Select Dial

2. Choke ­ Used to start a cold engine.

3

3. Intelligauge with Power Meter ­ See Intelligauge section.

4. Circuit Breakers (Flip Reset) ­ Protects the generator

2

against electrical overloads.

5. Circuit Breakers (Push Reset) ­ Protects the generator against electrical overloads.

6. Fuel Select Dial ­ Used to select and turn on gasoline,

1

propane (LPG), or natural gas (NG) fuel source.

AD BY CW
DC

RECEPTACLES
120/240V AC, 50A (NEMA 14-50R) May be used to supply electrical power for operation of 120/240 Volt AC, 50 Amp, single phase, 60 Hz electrical loads. 120/240V AC, 30A Locking (NEMA L14-30R) May be used to supply electrical power for operation of 120/240 Volt AC, 30 Amp, single phase, 60 Hz electrical loads. 120V AC, 30A Locking (NEMA L5-30R) May be used to supply electrical power for operation of 120 Volt AC, 30 Amp, single phase, 60 Hz electrical loads. (4×) 120V AC, 20A GFCI (NEMA 5-20R) May be used to supply electrical power for operation of 120 Volt AC, 20 Amp, single phase, 60 Hz electrical loads.

1. Gasoline ON 2. Gasoline OFF 3. Engine OFF 4. Propane (LPG) ON 5. Natural Gas (NG) ON

D 4 5

14

201161 – 12,000W TRI-FUEL PORTABLE GENERATOR

Intelligauge with Power Meter

Five mode digital meter for displaying voltage, frequency, session run time, total run time, and power output.

A. Power Meter

B. CO Shield® LED ­ The CO Shield® technology monitors

A

for accumulation of poisonous carbon monoxide (CO) gas

B

produced by engine exhaust when the generator is running. If

CO Shield® detects elevated levels of CO gas, it automatically

shuts off the engine.

  • *See CO Shield section for more information

CONTROLS AND FEATURES

MODE

1

Voltage (V)

Example: 120 volts

DESCRIPTION Output voltage of the generator.

2 Frequency (H) Example: 60.0 hertz

Output frequency in hertz.

3

Run Time (R)

Example: 6 hours

Run time of the generator for the current session.

4 Total Run Time Example: 16 hours

Total run time of the generator since first operation.

5

Output Power

Example: 100% Power

Continually displays generator output.

15

201161 – 12,000W TRI-FUEL PORTABLE GENERATOR
Industry Canada: CAN ICES-002/NMB-002

  • Applicable in Canada only.
    This device complies with Industry Canada license – exempt RSS standard(s). Operation is subject to the following two conditions: 1. This device may not cause interference, and 2. This device must accept any interference, including
    interference that may cause undesired operation of the device.
    Parts Included
    Accessories Engine Oil………………………………. 37.2 fl. oz. (1100 ml) Oil Funnel ………………………………………………….. 1 6.6 ft. (2 m) LPG Hose with Regulator……………………….. 1 25 ft. Natural Gas Hose Kit …………………………………. 1

CONTROLS AND FEATURES
Assembly Parts Wheels 12 in. (30.5 cm) Never Flat Wheel (A)………….. ………… 2 Wheel Hub Cap (B)………………………………………. 2 Roll Pin (C) ……………………………………………… 2 Washer Ø12 (D) ………………………………. ………… 2 Large R-clip (E) ………………………………. ………… 2
A

BC

DE

16

201161 – 12,000W TRI-FUEL PORTABLE GENERATOR
ASSEMBLY
Your generator requires some assembly. This unit ships from our factory without oil. It must be properly serviced with fuel and oil before operation. If you have any questions regarding the assembly of your generator, call our Technical Support Team at 1-877-338-0999. Please have your serial number and model number available.
Install the Wheel Kit
CAUTION
The wheel kit is not intended for over-the-road use.
Install the Wheels 1. Make sure all items have been removed from the shipping
carton/pallet and double check for any items that may be in the generator frame. 2. With the generator still on the pallet install the wheel. 3. Slide the wheel pin roll through the wheel from the outside. 4. Slide the wheel pin roll through the mount point on the frame. 5. Slide the washer and secure with the R-Pin. 6. Install wheel hub cap onto wheel.

ASSEMBLY
9. Raise handle and pull generator forward until wheels touch the ground. Then pull generator out from wood pallet.
Connect the Battery
1. Cut cable tie on each side of battery connector. 2. Push two halves of battery connector together tightly.

7. Repeat steps 2-6 to attach the second wheel.
8. Remove wooden blocks from in front of the frame and the support leg.

Add Engine Oil
WARNING
DO NOT attempt to crank or start the engine before it has been properly filled with the recommended type and amount of oil. Damage to the generator as a result of failing to follow these instructions will void your warranty.
NOTICE
The generator rotor has a sealed, pre-lubricated ball bearing that requires no additional lubrication for the life of the bearing.

17

201161 – 12,000W TRI-FUEL PORTABLE GENERATOR
NOTICE
The recommended oil type for typical use is 5W-30 automotive oil. However, using the listed conventional oils shown in the “Recommended Engine Oil Type” chart may be used for typical use including the first 5 hours of the break-in run time period of the engine. If running generator in extreme temperatures, refer to the “Recommended Engine Oil Type” chart.

Recommended Engine Oil Type 10W-30

5W-30

10W-40

5W-30 Full Synthetic

°F -20

0

20 40 60 80 100 120

°C -28.9 -17.8 -6.7 4.4 15.6 26.7 37.8 48.9

Ambient temperature

1. Place the generator on a flat, level surface.
2. Open the engine access cover.
3. Remove yellow cap on cylinder head cover on left side of engine.
4. Using funnel fill to full mark on dipstick. DO NOT OVERFILL. Volume for first use or oil change without oil filter change: 37.2 fl. oz. (1100 ml). Volume after oil and oil filter change: 47.3 fl. oz. (1400 ml).

ASSEMBLY
5. Pull out dipstick and check engine oil level. Add as needed. DO NOT OVERFILL.
6. Replace dipstick. 7. Close engine access cover.
NOTICE
Check oil level often during the break-in period. Refer to the Maintenance section for recommended service intervals.
CAUTION
This engine is equipped with a low oil shut-off and will stop when the oil level in the crankcase falls below the threshold level.
NOTICE
The first 5 hours of run time are the break-in period for the unit. During the break in period stay at or below 50% of the running watt rating and vary the load occasionally to allow stator windings to heat and cool. Adjusting the load will also cause engine speed to vary slightly and help seat piston rings. After the 5 hour break-in period, change the oil.
NOTICE
Synthetic oil may be used after the 5 hour initial break-in period. Using synthetic oil does not decrease the recommended oil change interval. Full synthetic 5W-30 oil will aid in starting in cold ambient < 41º F (5º C) temperatures.

18

201161 – 12,000W TRI-FUEL PORTABLE GENERATOR
Add Fuel: Gasoline
DANGER
Gasoline vapors are highly flammable and extremely explosive.
DO NOT light or smoke cigarettes. Fire or explosion can cause severe burns or death. Only fill or drain fuel outdoors in a well-ventilated area. DO NOT pump gasoline directly into the generator. Use an approved container to transfer the fuel to the generator. Never use a gasoline container, gasoline tank, or any other fuel item that is broken, cut, torn or damaged. DO NOT overfill the gasoline tank. Always keep fuel away from sparks, open flames, pilot lights, heat and other sources of ignition.
Use clean, fresh, regular unleaded gasoline with a minimum octane rating of 87 and an ethanol content of 10% or less by volume. y b c DO NOT mix oil with gasoline. 1. Remove the gasoline cap. 2. Slowly add gasoline to the tank. Tank is full when gasoline
reaches red circle on screen. DO NOT OVERFILL. Gasoline can expand after filling. A minimum of ¼ in. (6.4 mm) of space left in the tank is required for gasoline expansion, although more than ¼ in. (6.4 mm) is recommended. Gasoline can be forced out of the tank as a result of expansion if overfilled, and can affect the stable running condition of the generator.

ASSEMBLY
3. The approximate fuel level is shown on the fuel gauge on top of the fuel tank.

Empty

Full

F

E

F

E

4. Screw on the gasoline cap and wipe away any spilled fuel.
CAUTION
Use unleaded gasoline with a minimum octane rating of 87 and an ethanol content of 10% or less by volume.
DO NOT light cigarettes or smoke when filling the tank. DO NOT mix oil and gasoline. DO NOT overfill the tank. Fill tank to approximately ¼ in. (6.4 mm) below the top of the tank to allow for gasoline expansion. DO NOT pump gasoline directly into the generator at the pump. Use an approved fuel container to transfer the gasoline to the generator. DO NOT fill tank indoors. DO NOT fill tank when the engine is running or hot.
WARNING
Pouring gasoline too fast through the fuel screen may result in gasoline splashing over the generator and operator while filling.

19

201161 – 12,000W TRI-FUEL PORTABLE GENERATOR
NOTICE
The generator engine works well with 10% or less ethanol blended gasoline. When using ethanol-gasoline blends there are some issues worth noting: ­ Ethanol-gasoline blends can absorb more water than
gasoline alone. ­ These ethanol blends can eventually separate, leaving
water or a watery goo in the tank, fuel valve and carburetor. The compromised gasoline can be drawn into the carburetor and cause damage to the engine and/or create potential hazards. ­ If a fuel stabilizer is used, confirm that it is formulated to work with ethanol-gasoline blends. ­ Any damages or hazards caused by using ethanol blended gasoline higher than 10% by volume, improperly stored gasoline, and/or improperly formulated stabilizers, are not covered by manufacturer’s warranty. It is advisable to always shut off the gasoline supply and run the engine to starvation after each use. See Storage instructions for extended non-use.
Add Fuel: Propane (LPG)
DANGER
NEVER place the LPG (liquefied petroleum gas) connector hose OR LPG cylinder tank in the path of the muffler exhaust gas stream of the generator during engine operation.
Connecting an LPG cylinder 1. Make sure the fuel select dial is in the “ENGINE STOP”
position. 2. Remove the rubber protective plug from the female connector
of the LPG hose. 3. Pull and hold the outer collar of the female connector and
insert it over the male connector. Release outer collar. Pull on the hose to make sure it’s connected to the generator.

ASSEMBLY
4. Connect the other end of the LPG hose to the LPG cylinder valve and hand tighten.
5. Open valve on LPG cylinder and check all connections for leaks by wetting the fittings with a solution of soap and water. Bubbles which appear or bubbles which grow indicate that a leak exists. If a leak exists at a fitting then turn off the valve on the cylinder and tighten the fitting. Turn the valve back on and recheck the fitting with the soap and water solution. If the leak continues or if the leak is not at a fitting then do not use the generator and contact a qualified technician.
NOTICE
­ The LPG hose included with this unit works with standard 20, 30, and 40 pound LPG tanks.
­ Verify the requalification date on the cylinder has not expired.
­ Always position the cylinder so the connection between the cylinder valve and generator inlet won’t cause sharp bends or kinks in the LPG hose.
CAUTION
Do not allow children to tamper or play with the LPG cylinder or hose connections.
CAUTION
Use approved LPG cylinders equipped with an OPD (overfilling prevention device) valve. Always keep the cylinder in a vertical position with the valve on top and installed at ground level on a flat surface. Cylinders must not be installed near any heat source and should not be exposed to sun, rain, and dust. When transporting and storing, turn off the cylinder valve and generator LPG valve, and disconnect the cylinder. Plug the outlet, usually by a plastic protective cap, if one is available. Keep cylinders away from heat and ventilated when in a vehicle.
WARNING
If there is a strong smell of LPG: Close valve on the cylinder. Check all connections for leaks by wetting the fittings with a solution of soap and water. Bubbles which appear or bubbles which grow indicate that a leak exists. Do not smoke or light a cigarette, or check for leaks using a match, open flame source or lighter. Contact a qualified technician to inspect and repair an LPG system if a leak is found, before using the generator.

20

201161 – 12,000W TRI-FUEL PORTABLE GENERATOR
Add Fuel: Natural Gas (NG) DANGER
NEVER place NG connector hose in the path of the generator’s muffler exhaust gas stream while the generator is running.
Connecting the NG hose 1. Use pipe sealant, joint compound, or Teflon tape when
connecting the adapter fitting from the hose kit to the NG supply line. 2. Connect the female flare end of the NG hose to the adapter fitting. NO pipe sealant, joint compound, or Teflon tape is to be used on this connection. 3. Remove the rubber protective plug from the female quick connect end of the NG hose. 4. Pull and hold the outer collar of the female quick connect and insert it over the male connector on the generator. Release outer collar. Pull on the hose to make sure it is securely connected to the generator.
5. Before operation, open the NG supply line and check for leaks. Use a soapy water mixture to verify all connections prior to starting the generator. If soapy bubbles are present indicating leaks turn off the NG supply and do not start generator. Recheck connections and tightness and turn NG supply valve back on and repeat soapy water mixture on connection fitting. If the NG leak continues do not use the generator and contact a qualified technician for repair.
6. Close the NG supply valve.
Grounding
Your generator must be properly connected to an appropriate ground to help prevent electric shock.
WARNING
Failure to properly ground the generator can result in electric shock.

OPERATION
A ground terminal connected to the frame of the generator has been provided (see Controls and Features for terminal location). For remote grounding, connect a length of heavy gauge (12 AWG minimum) copper wire between the generator ground terminal and a copper rod driven into the ground. We strongly recommend that you consult with a qualified electrician to ensure compliance with local electrical codes. Neutral Floating ­ Neutral circuit IS NOT electrically connected to the frame/
ground of the generator.
­ The generator (stator winding) is isolated from the frame and from the AC receptacle ground pin.
­ Electrical devices that require a grounded receptacle pin connection will not function if the receptacle ground pin is not functional.
Neutral Bonded to Frame
­ Neutral circuit IS electrically connected to the frame/ground of
the generator.
­ The generator system ground connects lower frame crossmember below the alternator. The system ground is connected to the AC neutral wire.

  • See your Specifications section for specified type of grounding.
    OPERATION
    CO Shield® – Carbon Monoxide (CO) Detection and Auto-shutoff System
    CO Shield® technology monitors the accumulation of carbon monoxide (CO), a poisonous gas produced by engine exhaust when the generator is running. If CO Shield® detects unsafe elevated levels of CO gas, it automatically shuts off the engine.
    CO SHIELD® IS NOT A SUBSTITUTE FOR AN INDOOR CARBON MONOXIDE ALARM OR FOR INDOOR OPERATION.
    DO NOT allow engine exhaust fumes to enter a confined area through windows, doors, vents or other openings.
    Generators must ALWAYS be used outdoors, far away from occupied buildings with engine exhaust pointed away from people and buildings.

21

201161 – 12,000W TRI-FUEL PORTABLE GENERATOR
If misused and operated in an unapproved and unsafe location that results in the accumulation of poisonous CO gas inside an enclosed or partially enclosed space, for example a house, garage or a garage with the door partially open, CO Shield® will automatically shut off the generator and then will illuminate a blinking red LED light. Read the action label for next steps.

OPERATION
If CO Shield® system experiences a fault and no longer provides protection, the generator is shutoff automatically and the yellow LED light will blink for at least five (5) minutes to notify you of the fault.

ACTION LABEL ETIQUETA DE ACCIÓN ÉTIQUETTE D’ACTION

AUTOMATIC SHUTOFF ­ YOU MUST: APAGADO AUTOMÁTICO ­ USTED DEBE: ARRÊT AUTOMATIQUE ­ VOUS DEVEZ :

3783-L-SF

Move generator to an open, outdoor area. Point exhaust away. Don’t run generators in enclosed areas (e.g. not in house or garage).

Mover el generador a un área abierta a la intemperie. Apunte el escape alejado. No corra los generadores en áreas cerradas (ej. no en una casa o garaje).
Déplacer le générateur vers un espace extérieur en plein air. Garder l’échappement loin. Ne pas faire fonctionner les générateurs dans un espace clos (ex., pas dans une maison ou un garage).

Move to fresh air and get medical help if sick, dizzy or weak.

EXHAUST EL ESCAPE L’ECHAPPEMENT

Mueva al aire fresco y obtenga asistencia medica si está enfermo, mareado, o débil.
Aller à l’air frais et obtenir de l’aide médicale si malade, étourdi ou faible.

POINT AWAY DIRIJA ALEJADO
DIRIGER LOIN

In the event of an engine shut off, when you approach the generator to investigate, a blinking red LED light in the CO Shield® area provides notification that the generator shut off due to an accumulating CO hazard. The red LED light will blink for at least five (5) minutes after an engine shut off event.

AUTOMATIC SHUTOFF SEE ACTION LABEL
APAGADO AUTOMÁTICO VEA ETIQUETA DE ACCIÓN
ARRÊT AUTOMATIQUE VOIR L’ÉTIQUETTE D’ACTION

SERVICE
REALICE UN SERVICIO
EFFECTUER L’ENTRETIEN

Move the generator far away to an open, outdoor area and point the exhaust away from people and buildings. Once relocated to a safe area, the generator can be restarted, and the proper electrical connections made. Introduce fresh air and ventilate the location where the generator shut off.
When restarting, the red and yellow LED will blink ten (10) times simultaneously to indicate the LED is working.

NOTICE
This blinking LED light does not indicate CO Shield® is working, as CO Shield® is working at all times when the generator is running. Also, the LED light will not blink (10) times if the generator was restarted within 1 minute after it was manually shut off. This does not occur if generator shut off from a high CO event.

AUTOMATIC SHUTOFF SEE ACTION LABEL
APAGADO AUTOMÁTICO VEA ETIQUETA DE ACCIÓN
ARRÊT AUTOMATIQUE VOIR L’ÉTIQUETTE D’ACTION

SERVICE
REALICE UN SERVICIO
EFFECTUER L’ENTRETIEN

Call our Technical Support Team at 1-877-338-0999 for repair. The generator can be restarted, but will continue to shutoff.
NOTICE
CO Shield® will detect the accumulation of carbon monoxide (CO) from other fuel burning sources such as engine powered equipment, or propane heaters used in the area of operation. If another generator is used and the exhaust stream is pointed at a CO Shield® equipped generator, the CO Shield® may initiate a shutoff due to rising carbon monoxide (CO) levels. This is not a fault. Poisonous carbon monoxide (CO) has been detected. You must take action to move and direct the generator exhaust stream to better disperse carbon monoxide (CO) far away from people or buildings.

DANGER
Tampering with the CO Shield® system will result in a hazardous condition and will void your warranty.
Removing the CO Shield® module will not allow the generator to start.

22

201161 – 12,000W TRI-FUEL PORTABLE GENERATOR
Generator Location
WARNING
NEVER operate the generator inside any building, garage, basement, crawlspace, shed, enclosure or compartment, including a generator compartment of a recreational vehicle.
NEVER operate or start the generator in the back of an SUV, camper, trailer, truck bed (regular sides, flat or other configuration), under staircases, stairwells, next to walls or buildings or in any other location that will not allow for adequate cooling of the generator or for the proper exit of the exhaust flow from the muffler system.
DO NOT operate or store the generator in wet weather conditions such as rain or snow. Using a generator in wet conditions could result in serious injury or death due to electrocution.
In some state’s generators may be required to be registered with the local utility company when used at construction sites and may be subject to additional rules and regulations, consult your local municipal authority.
Generators should always be operated on a flat, level surface at all times (even when not in operation).
Generators must have a minimum of 5 feet (1.5 m) of clearance from all combustible material.
Generators must also have a minimum of 3 feet (91.4 cm) of air flow clearance on all sides to allow for adequate performance cooling, maintenance and servicing.
Always place the generator in a well-ventilated area. NEVER place the generator near air intake vents or where exhaust fumes could be drawn into occupied or confined spaces.
Always carefully consider wind and air currents when positioning generator.
Always allow generators to properly cool before transport or for storage purposes.
Failure to follow proper safety precautions may result in personal injury, damage to the generator and void the manufacturer’s warranty.
WARNING
During operation the muffler and exhaust fumes will become hot. If adequate cooling and breathing space are not supplied, or if the generator is blocked or enclosed, temperatures can become extremely heated and may lead to fire.

OPERATION
WARNING
Do not expose to rain or use in damp locations. Keep all objects a minimum of 5 feet (1.5m) away from the generator at all times. Heat from the muffler surface and exhaust gas stream can ignite combustible materials.
WARNING
If you must operate in rain or damp locations, DO NOT operate without proper protection of the electrical components.
Use of a safety canopy that is fire retardant and will provide proper air ventilation for the engine exhaust gas stream may be used. Visit championpowerequipment.com or call to find your Storm Shield cover.
Surge Protection
Electronic devices, including computers and many programmable appliances use components that are designed to operate within a narrow voltage range and may be affected by momentary voltage fluctuations. While there is no way to prevent voltage fluctuations, you can take steps to protect sensitive electronic equipment. ­ Install UL1449, CSA-listed, plug-in surge suppressors on the
outlets feeding your sensitive equipment. Surge suppressors come in single- or multi-outlet styles. They’re designed to protect against virtually all short- duration voltage fluctuations.
Starting the Engine: Gasoline
1. Make certain the generator is on a flat, level surface and all circuit breakers are reset (button pushed in).
2. Disconnect all electrical loads from the generator. Never start or stop the generator with electrical devices plugged in or turned on.
3. Turn the fuel select dial to the “GASOLINE ON” position.

23

201161 – 12,000W TRI-FUEL PORTABLE GENERATOR 4. Pull the choke knob out.
5. Press and hold the ignition switch to the “START” position. Release as the engine begins to start. If the engine fails to start within five seconds, release the switch and wait at least ten seconds before attempting to start the engine again.
CAUTION
If the ignition switch is held down in the “START” position longer than 5 seconds it could damage the starter.

OPERATION Starting the Engine: Propane (LPG)
1. Make certain the generator is on a flat, level surface and all circuit breakers are reset (button pushed in).
2. Disconnect all electrical loads from the generator. Never start or stop the generator with electrical devices plugged in or turned on.
3. Connect LPG hose to generator and LPG cylinder. See “Add Fuel: Propane (LPG)” section of the manual.
4. Fully open the valve on the LPG cylinder.
5. Turn fuel select dial to the “PROPANE ON” position.

6. Do not over-choke. As soon as engine starts, push the choke knob in.

6. Pull the choke knob out.

7. Plug in devices.
NOTICE
If the engine starts but does not run make certain that the generator is on a flat, level surface. The engine is equipped with a low oil sensor that will prevent the engine from running when the oil level falls below a critical threshold.
24

201161 – 12,000W TRI-FUEL PORTABLE GENERATOR
7. Press the ignition switch to the “START” position for 2-3 seconds.

OPERATION
NOTICE
If the engine starts but does not run make certain that the generator is on a flat, level surface. The engine is equipped with a low oil sensor that will prevent the engine from running when the oil level falls below a critical threshold.

8. Push the choke knob in.
9. Press and hold the ignition switch in the “START” position for up to 5 seconds or until started.
NOTICE
If the engine is cranked longer than 5 seconds, the engine can flood and will not start. 10. If engine does not start, wait 10 seconds and repeat step 9. 11. When the engine starts, push choke knob to the “RUN”
position if in the ” CHOKE” position. 12. Plug in devices.

NOTICE
Accumulation of frost on LPG cylinder and regulators is common during operation and normally is not an indication of a problem. As LPG vaporizes and travels from the cylinder to the generator engine it expands. The amount of frost that forms can be affected by the size of the cylinder, the amount of LPG being used, the humidity of the air and other operating conditions.
In unusual situations this frost may eventually restrict the flow of LPG to the generator resulting in deteriorating performance. For example, if the cylinder temperature is reduced to a very low level then the rate at which the LPG vaporizes is also reduced and may not provide sufficient flow to the engine. This is not an indication of a problem with the generator but only a problem with the flow of LPG from the cylinder. If generator performance seems to be deteriorating at the same time that ice formation is observed on tank valve, hose or regulator then some actions may be taken to eliminate this symptom.
In these rare situations it can be helpful to reduce or eliminate the cold fuel system effects by doing one of the following:
­ Exchanging fuel cylinders to allow the first cylinder to warm up, repeating as necessary.
­ Placing the cylinder at the end of the generator near the handle, where engine fan air flows out from the generator. This air is slightly heated by flowing over the engine. The cylinder should not be placed in the path of the muffler outlet.
­ The cylinder can be temporarily warmed by pouring warm water over the top of the cylinder.
Starting the Engine: Natural Gas (NG)
1. Make certain the generator is on a flat, level surface and all circuit breakers are reset (button pushed in).
2. Disconnect all electrical loads from the generator. Never start or stop the generator with electrical devices plugged in or turned on.
3. Connect NG hose to generator. See “Add Fuel: Natural Gas (NG)” section of the manual.

25

201161 – 12,000W TRI-FUEL PORTABLE GENERATOR 4. Open Natural Gas fuel supply valve.
ON

8. Push the choke knob in.

OPERATION

5. Turn fuel select dial to the “NATURAL GAS ON” position.

9. Press and hold the ignition switch in the “START” position for up to 5 seconds or until started.

6. Pull the choke knob out.

7. Press the ignition switch to the “START” position for 2-3 seconds.

NOTICE
If the engine is cranked longer than 5 seconds, the engine can flood and will not start.
10. If engine does not start, wait 10 seconds and repeat step 9. 11. When the engine starts, push choke knob to the “RUN”
position if in the ” CHOKE” position. 12. Plug in devices.
NOTICE
If the engine starts but does not run make certain that the generator is on a flat, level surface. The engine is equipped with a low oil sensor that will prevent the engine from running when the oil level falls below a critical threshold.

Battery
NOTICE
The supplied 12V sealed lead acid (SLA) battery will recharge while the engine is running. When the generator is not in use for extended periods of time, it is recommended that the battery be fully charged at least once a month with a slow charger and disconnected when fully charged or charged using a battery maintainer for long-term storage (not included).
26

201161 – 12,000W TRI-FUEL PORTABLE GENERATOR
Connecting Electrical Loads
Let the engine stabilize and warm up for a few minutes after starting.
Plug in and turn on the desired 120 or 240 (if applicable) Volt AC single phase, 60 Hz electrical loads.
­ DO NOT connect 3-phase loads to the generator. ­ DO NOT overload the generator. ­ Use only a high quality, insulated, compatible (3-wire or
4-wire) grounded cord set rated equal to or greater (volts and amps) than the receptacle plugging into.
WARNING
Always remember to plug your appliances directly into the generator and do not plug the generator power cord into any electrical outlet or connect to the circuit breaker panel in your home. Connecting a generator to your home’s electric utility company’s power lines, or to another power source, called `backfeeding’ is a dangerous practice that is illegal in many states and municipalities.
This action if done incorrectly could damage your generator, appliances and could cause serious injury or death to you or a utility worker when attempting to restore power during an outage occurrence in the neighborhood who may then unexpectedly encounter high voltage on the utility line and suffer a fatal shock.
Whether injuries occur or not, if installed incorrectly and not to applicable laws and codes, you may be subject to fines or the utility company may disconnect your home power should this practice be found in your home.
If the generator will be connected to a building electrical system, those connections must isolate the generator power from the utility power. You are responsible for ensuring your generator’s electricity does not backfeed into the electric utility power lines. These connections must comply with all applicable laws and codes ­ Consult your local utility company or a qualified electrician to properly install this connection.
Do Not Overload Generator
Capacity
Follow these simple steps to calculate the running and starting watts necessary for your purposes:
1. Select the electrical devices you plan on running at the same time.
2. Total the running watts of these items. This is the amount of power you need to keep your items running.

OPERATION
3. Identify the highest starting wattage of all devices identified in step 1. Add this number to the number calculated in step 2. Starting wattage is the surge of power needed to start some electric driven equipment. Following the steps listed under “Power Management” will guarantee that only one device will be starting at a time.
Power Management Use the following formula to convert voltage and amperage to watts:
Volts × Amps = Watts To prolong the life of your generator and attached devices, follow these steps to add electrical load: 1. Start the generator with no electrical load attached. 2. Allow the engine to run for several minutes to get up to
temperature. 3. Make sure all circuit breakers are set to the run position. 4. Plug in and turn on the first item. It is best to attach the item
with the largest load first. 5. Allow the engine to stabilize. 6. Plug in and turn on the next item. 7. Allow the engine to stabilize. 8. Repeat steps 5-6 for each additional item.
NOTICE
Never exceed the specified capacity when adding loads to the generator.
GFCI
Your generator is equipped with ground fault circuit interrupter (GFCI) receptacles. In the event of a ground fault, a GFCI trips automatically to stop the flow of electricity and prevent serious injury. The green indicator light (A) on the receptacle will also turn off. Press the “RESET” (B) button located on the front of the receptacle to restore flow of electricity. The indicator light will also turn back on. GFCI does not protect against circuit overloads. To ensure proper operation of the GFCI duplex, perform this test monthly: 1. With the generator running, plug a lamp into the GFCI
receptacle. Turn the lamp on. 2. Press the “TEST” (C) button located on the front of the
receptacle to trip the device. This should immediately stop the flow of electricity and shut off the lamp. If the electricity is not stopped, do not use this receptacle until it has been serviced or replaced.

27

201161 – 12,000W TRI-FUEL PORTABLE GENERATOR
3. Press the “RESET” button located on the front of the receptacle to restore the flow of electricity. If the indicator light does not come back on or if the GFCI cannot be reset then it must be replaced.
A
B C
NOTICE
In any electrical application, some current will flow through the protective ground conductor to the ground, this is called leakage current. It takes 4 mA (0.004 A) and higher of leakage current from the hot wire to the ground to cause a GFCI to trip. On circuits protected by GFCI’s, leakage current can cause unnecessary and intermittent tripping. Some stationary motors, such as a bathroom vent fan, fluorescent lighting fixtures or some refrigerators, may produce enough leakage to cause nuisance tripping. To avoid nuisance tripping, a GFCI should not supply: ­ Fluorescent or other types of electric-discharge lighting
fixtures. ­ Permanently installed electric motors, like air conditioners,
furnaces or refrigerators.
Stopping the Engine
1. Turn off and unplug all connected electrical loads. Never start or stop the generator with electrical devices plugged in or turned on.
2. Let the generator run at no-load for several minutes to stabilize internal temperatures of the engine and generator.
3. Turn the fuel select dial to the “ENGINE OFF” position.

OPERATION
4. If operating on LPG, close valve on LPG cylinder. If operating on NG, close NG supply valve.
Important: Always ensure that the fuel select dial is in the “OFF” position when the generator is not in use.
NOTICE
If the engine will not be used for a period of two (2) weeks or longer, please see the Storage section for proper engine and fuel storage.
Moving the Generator
CAUTION
­ NEVER lift or carry the generator using the folding handle. ­ NEVER tilt sideways while moving the generator. ­ ALWAYS place the generator on its wheels in the upright
position. ­ ALWAYS turn the generator off and ensure the fuel valve is
closed. ­ ALWAYS make sure engine and muffler are cooled down
before the generator can be handled safely (typically 15-30 minutes).
WARNING
The folding handle is not long enough to hold and walk with a full stride when moving the generator. Always side step as you walk to avoid injury to your heels and/or feet. Failure to follow these instructions could result in personal injury or damage to the generator.
1. Begin by raising the folding handle, found on opposite side of wheels.
2. Using the handle, tilt the end of the generator slightly off the ground until balanced on the wheels.
3. While maintaining balance, roll the generator to the desired location.

28

201161 – 12,000W TRI-FUEL PORTABLE GENERATOR
Operation at High Altitude
The density of air at high altitudes is lower than at sea level. Engine power is reduced as the air mass and air-fuel ratio decrease. Engine power and generator output will be reduced approximately 3½% for every 1000 ft. of elevation above sea level. At high altitudes increased exhaust emissions can also result due to the increased enrichment of the air fuel ratio. Other high altitude issues can include hard starting, increased fuel consumption and spark plug fouling.
To place an order for a high-altitude jet, please visit our Help Center for jet removal instructions on your specific model. You will need to supply the jet number to the Customer Service Representative when ordering your high- altitude jet. Please visit https://help.championpowerequipment.com/ to find the relevant instructions for your model.
WARNING
Operation using the alternative main jet at elevations lower than the recommended minimum altitude can damage the engine. For operation at lower elevations, the originally supplied standard main jet must be used. Operating the engine with the wrong engine configuration at a given altitude may increase its emissions and decrease fuel efficiency and performance.
MAINTENANCE
Make certain that the generator is kept clean and stored properly. Only operate the unit on a flat, level surface in a clean, dry operating environment. DO NOT expose the unit to extreme conditions, excessive dust, dirt, moisture or corrosive vapors.
WARNING
Never operate a damaged or defective generator.

MAINTENANCE
Cleaning the Generator
CAUTION
DO NOT spray generator directly with water.
Water can enter the generator through the cooling slots and damage the generator windings. It can also contaminate the fuel system.
1. Use a damp cloth to clean exterior surfaces of the generator. 2. Use a soft bristle brush to remove dirt and oil. 3. Use an air compressor (25 PSI) to clear dirt and debris from
the generator. 4. Inspect all air vents and cooling slots to ensure that they are
clean and unobstructed. To prevent accidental starting, remove and ground the spark plug wire before performing any service.
Changing Engine Oil and Filter
Change oil when the engine is warm. Refer to the oil specification to select the proper grade for your operating environment. 1. Remove the oil drain bolt. 2. Allow the oil to drain completely into an appropriate container.

WARNING
Improper maintenance will void your warranty.
NOTICE
For Emission control devices and systems, read and understand your responsibilities for service as stated in the Emission Control Warranty Statement of this manual.

3. Replace the oil drain bolt. 4. Remove oil filter by turning counterclockwise.

The owner/operator is responsible for all periodic maintenance. Complete all scheduled maintenance in a timely manner. Correct any issue before operating the generator. For service or parts assistance, contact our Technical Support Team at 1-877-338-0999.
29

201161 – 12,000W TRI-FUEL PORTABLE GENERATOR 5. Apply a light coat of clean oil onto the gasket of new oil filter.

MAINTENANCE
6. Firmly re-install the plug. 7. Attach the spark plug cable to the spark plug. 8. Repeat Steps 1-7 for spark plug on other side of engine.
Cleaning the Air Filter
1. Open engine access cover. 2. Remove the air filter cover by turning the two fasteners ¼
turn counterclockwise. 3. Pull the air filter straight out away from engine.

6. Install new oil filter by turning clockwise by hand until gasket contacts the engine block. Then apply additional 3/4 turn.
7. Add oil according to Add Engine Oil in Assembly section. DO NOT OVERFILL. Oil not included for routine maintenance.
8. Dispose of used oil and filter at an approved waste management facility.
Cleaning and Adjusting the Spark Plugs
1. Remove the spark plug cable from the spark plug.
2. Use a spark plug socket tool (not included), or a 13/16 in. (21 mm) socket (not included) to remove the plug.
3. Inspect the electrode on the plug. It must be clean and not worn to produce the spark required for ignition.
4. Make certain the spark plug gap is 0.022-0.028 in. (0.55-0.7 mm).

4. Install new air filter. 5. Replace air filter cover and turn the two fasteners ¼ turn
clockwise. 6. Close engine access cover.
Cleaning the Spark Arrestor
1. Allow the engine to cool completely before servicing the spark arrestor.
2. Remove the two screws holding the cover plate which retains the spark arrestor to the muffler.
3. Remove the spark arrestor screen. 4. Carefully remove the carbon deposits from the spark arrestor
screen with a wire brush.

SPARK PLUG GAP

5. Refer to the spark plug types in Specifications when replacing the plug.

5. Replace the spark arrestor if it is damaged.
6. Position the spark arrestor on the muffler and attach with the screws removed in step 2.

30

201161 – 12,000W TRI-FUEL PORTABLE GENERATOR
CAUTION
Failure to clean the spark arrestor will result in poor engine performance.
NOTICE
Federal and local laws and administrative requirements indicate when and where spark arrestors are required. When ordered, spark arrestors are required for operation of this generator in National Forest lands. In California, this generator must not be used on any forest-covered land, brush-covered land, or grass-covered land unless the engine is equipped with a spark arrestor.
Replacing Fuel Filter
1. Move clips on each side of fuel filter.
2. Pull fuel hose off each end of fuel filter.
3. Push fuel hose on each end of new filter.

4. Return clips to end of fuel hose.

MAINTENANCE

Adjusting the Governor
WARNING
Tampering with the factory set governor will void your warranty.
The air-fuel mixture is not adjustable. Tampering with the governor can damage your generator and your electrical devices and will void your warranty. Contact our Technical Support Team at 1-877-338-0999 for all other service and/or adjustment needs.
Generator Battery
Your generator is equipped with an automatic battery charging circuit that charges the battery while the engine is running. The battery will maintain a proper charge if the unit is used on a regular basis (about once every two weeks). If it is used less frequently, the battery should be connected to a trickle charger or battery maintainer (not included) to keep the battery properly charged.
Maximum charging rate should not exceed 1.5 amps. Follow the instructions included with the battery charger. The battery should be fully charged at least once per month. If the battery is not able to start the engine, it can be started by manually pulling the engine recoil cord. If the battery voltage is extremely low, the charging circuit may not be able to re-charge the battery. In this case, the battery must be connected to a standard automotive style battery charger for re-charging before it can be used. Disconnect the Battery
1. Pull two halves of battery connector apart.

31

201161 – 12,000W TRI-FUEL PORTABLE GENERATOR
Charge the Battery For a generator equipped with batteries for electric starting, proper battery maintenance and storage should be followed. A trickle charger or battery maintainer should be used to charge the battery while the generator is in storage. Maximum charging rate should not exceed 1.5 amps. Follow the instructions included with the trickle charger or battery maintainer. The battery should be fully charged at least once per month.
Maintenance Schedule
Follow the service intervals indicated in the following maintenance schedule. Service your generator more frequently when operating in adverse conditions. Contact our Technical Support Team at 1-877-338-0999 to locate the nearest CPE certified service dealer for your generator or engine maintenance needs.
EVERY 8 HOURS OR PRIOR TO EACH USE Check oil level Clean around air intake and muffler
FIRST 5 HOURS (BREAK IN) Change oil and oil filter
EVERY 50 HOURS OR ANNUALLY Clean air filter Change oil if operating under heavy load or in hot
environments
EVERY 100 HOURS OR ANNUALLY Change oil and oil filter Clean/adjust spark plug Clean spark arrestor Replace fuel filter

STORAGE
STORAGE
WARNING
To avoid accidental or unintended ignition of your generator during periods of storage, the following precautions should be followed: ­ When storing the generator make sure the fuel select dial
is set to the “OFF” position.
NOTICE
The following storage instructions apply when gasoline has been used to run the generator. NOTE: LPG does not apply and will not create build up or clog the carburetor.
Short Term Storage (30 days ­ 1 year)
Ethanol blended gasoline in the tank has a maximum shelf life of up to 1 year with the addition of a properly formulated fuel stabilizer and stored in a cool, dry place. 1. Be sure all appliances are disconnected from the generator. 2. Add a properly formulated fuel stabilizer to the gasoline tank. 3. Turn the fuel select dial to the “GASOLINE ON” position. 4. Start and run the generator for 10 minutes so the treated
gasoline cycles through the fuel system. 5. Turn the fuel select dial to the “ENGINE OFF” position. 6. Let the generator run until fuel starvation has stopped the
engine. This may take a few minutes. 7. Press the ignition switch to the “OFF” position. 8. Allow generator to cool completely before continuing. 9. Remove the spark plug cap and spark plug and pour about a
tablespoon of oil into each of the cylinders.

EVERY 250 HOURS
Clean combustion chamber Check/adjust valve clearance

EVERY 3 YEARS Replace fuel line*

  • To be performed by knowledgeable, experienced owners or CPE certified service centers.

10. Install the spark plug on each cylinder but DO NOT install spark plug cap.
11. With fuel select dial in the “ENGINE OFF” position, crank engine for 2 seconds using ignition switch.

32

201161 – 12,000W TRI-FUEL PORTABLE GENERATOR

STORAGE

12. Install spark plug cap on each cylinder. 13. Clean the generator according to Cleaning the Generator. 14. Store the generator in a cool, dry place out of direct sunlight.
Long Term Storage (over 1 year)
For storage over 1 year, the gasoline tank must be completely drained of gasoline. 1. The generator is to be OFF and all appliances disconnected. 2. Place appropriate container under the fuel tank drain fitting.
Move clip on fuel line connected to fuel tank. Pull fuel line off fuel tank fitting to allow fuel to drain into container.

Removing from Storage: Gasoline
NOTICE
If the generator has been improperly stored for a period longer than 30 days with ethanol blended gasoline in the gasoline tank, all fuel must be drained. If the gasoline tank was properly emptied of all ethanol blended gasoline prior to the generator being stored, follow the below steps when removing from storage.
1. Be sure the fuel select dial is in the “ENGINE OFF” position. 2. Add gasoline to the generator according to Add Fuel. 3. Turn the fuel select dial to the “GASOLINE ON” position. 4. After 5 minutes check for any leaking gasoline. If no gasoline
leaks are found, turn the fuel select dial to the “ENGINE OFF” position. 5. Check engine oil level and add clean, fresh oil if needed. See Oil Specifications for proper oil type. 6. Check air filter of any obstructions such as bugs or cobwebs. If necessary, clean air filter according to Cleaning the Air Filter. 7. Start the generator according to Starting the Engine.

3. When gasoline stops flowing from the fuel tank, return fuel hose and clip to fuel tank fitting. Properly dispose of the drained gasoline according to local regulations or guidelines.
4. Follow steps 9-14 according to Short Term Storage.
LPG Storage
Always disconnect the LPG hose from the generator and shut off the LPG tank for proper storage. Cover LPG/NG Inlet on Control Panel with protective cap. Always keep cylinders away from heat.

Removing from Storage: Propane (LPG)
Upon removal from storage, inspect LPG fittings and hose lines for leaks before using the generator.
WARNING
If there is a strong smell of LPG: Close valve on the cylinder. Check all connections for leaks by wetting the fittings with a solution of soap and water. Bubbles which appear or bubbles which grow indicate that a leak exists. Do not smoke or light a cigarette, or check for leaks using a match, open flame source or lighter. Contact a qualified technician to inspect and repair an LPG system if a leak is found, before using the generator.

NG Storage
Always disconnect the NG hose from the generator and shut off NG fuel supply valve.
Cover LPG/NG Inlet on Control Panel with protective cap.

Removing from Storage: Natural Gas (NG)
Upon removal from storage, inspect NG fittings and hose lines for leaks before using the generator.
WARNING

If there is a strong smell of NG: Close NG supply valve. Check all connections for leaks by wetting the fittings with a solution of soap and water. Bubbles which appear or bubbles which grow indicate that a leak exists. Do not smoke or light a cigarette, or check for leaks using a match, open flame source or lighter. Contact a qualified technician to inspect and repair an NG system if a leak is found, before using the generator.
33

201161 – 12,000W TRI-FUEL PORTABLE GENERATOR
SPECIFICATIONS
Generator Specifications
Generator Model ……………………………………. 201161 Start Type …………………………………………… Electric Watts (Starting/Running) ……………………… 15000/12000 Watts (LPG) (Starting/Running)…………………. 13750/11000 Watts (NG) (Starting/Running) ………………….. 12500/10000 Volts AC…………………………………………….. 120/240 Gasoline AC Amps @ 120V ………………………………. 100 Gasoline AC Amps @ 240V ……………………………….. 50 Frequency …………………………………………….. 60 Hz Phase ………………………………………………… Single Grounding Type…………………….. Neutral Bonded to Frame Weight …………………………………….. 347 lb. (157.5 kg) Length ………………………………………. 32.7 in. (83 cm) Width …………………………………….. 33.7 in. (85.6 cm) Height………………………………………33.1 in. (84.2 cm)
Engine Specifications
Model …………………………………… YF2V78FD-SAI-GLN Displacement …………………………………………. 717 cc Type…………………………………… V-Twin, 4-stroke, OHV Spark Plug OEM Type…………………………………………….. F7RTC Replacement Type…………………. NGK BPR7ES or equivalent Gap ………………………….. 0.022-0.028 in. (0.55-0.7 mm) Valve Intake Clearance …………….. 0.005-0.007 in. (0.13-0.17 mm) Exhaust Clearance …………… 0.005-0.007 in. (0.13-0.17 mm)
NOTICE
A technical bulletin regarding valve adjustment procedures is available at www.championpowerequipment.com.

SPECIFICATIONS

Oil Specifications
DO NOT OVERFILL. Type…………………………………….. *See following chart Capacity ……………………………….. 47.3 fl. oz. (1400 ml)

Recommended Engine Oil Type 10W-30

5W-30

10W-40

5W-30 Full Synthetic

°F -20

0

20 40 60 80 100 120

°C -28.9 -17.8 -6.7 4.4 15.6 26.7 37.8 48.9

Ambient temperature

NOTICE
Temperature will affect engine oil and engine performance. Change the type of engine oil used based on temperature shown in the “Recommended Engine Oil Type” table.

Fuel Specifications
Gasoline
Use unleaded gasoline with a minimum octane rating of 87 and an ethanol content of 10% or less by volume. DO NOT USE E15 or E85. DO NOT OVERFILL.
Gasoline Capacity …………………………… 11 gal. (41.20 L) Propane (LPG)
­ Use only an approved LPG cylinder equipped with an OPD (overfilling prevention device) valve.
Natural Gas (NG)
­ A dedicated NG fuel supply line with shut-off valve is mandatory for proper operation. The gas supply line and shut-off valve coming out of the house MUST be sized to the minimum flow rate as specified in the following table. Improper gas supply sizing from the house is the number one cause for poor operating performance such as hard starting or poor output power.
NOTICE
Consult your local fuel supplier and municipality for guidance on proper local codes and installations. All piping must comply with ANSI Z21.54/CSA 8.4 and related codes. Gas line connections should be made by a certified plumber familiar with local codes.

34

201161 – 12,000W TRI-FUEL PORTABLE GENERATOR

­ The NG fuel supply should have a BTU content of at least 1,000 BTU’s per cubic foot. Contact the fuel supplier for the BTU content of the supplied NG.
­ NG companies have different gas meters for increased demands. Verify that the current gas meter can provide enough NG flow to accommodate the additional demand of the generator with the current household appliances or other NG loads. Also ask what pressure the primary regulator on the gas meter is set to. The generator requires 5-7 inches water column pressure to run properly.

Natural Gas Fuel System Requirements

Nominal fuel rating Fuel supply pressure Minimum flow rate

1000 BTU/cu ft 5-7″ W.C. (1.2-1.7 kPa W.C.) 200,000 BTU/hr

Battery Specifications
Type………………….. Rechargeable, Non-Spillable Lead Acid Volts DC …………………………………………………. 12 Capacity ……………………………………………….33 Ah
Temperature Specifications
Starting Temperature Range (°F/°C) ……….. 5 to 104/-15 to 40
NOTICE
An important message about temperature: Your product is designed and rated for continuous operation at ambient temperatures up to 104°F (40°C). When needed, it may be operated at temperatures ranging from 5°F (-15°C) to 122°F (50°C) for short periods of time. If exposed to temperatures outside this range during storage, it should be brought back within this range before operation. In any event, the product must always be operated outdoors, in a well- ventilated area and away from doors, windows and vents.

SPECIFICATIONS

35

201161 – 12,000W TRI-FUEL PORTABLE GENERATOR

TROUBLESHOOTING

TROUBLESHOOTING
Problem Engine will not start. Engine starts but runs roughly. Engine will not start electrically.
Engine shuts down during operation.

Cause No fuel. Faulty spark plug.
Low oil level.
Spark plug wire loose. Fuel select dial OFF. Old fuel or water in fuel. Flooded with fuel. CO Shield® module has been removed or tampered with. Choke in the wrong position. Dirty air filter. Dirty fuel filter. Clogged spark arrestor. Generator battery is dead. Out of fuel.
Low oil level.

Solution Add fuel. Clean and adjust spark plug or replace. Fill crankcase to the proper level. Place generator on a flat, level surface. Attach wire to spark plug. Check both spark plugs. Move fuel select dial to appropriate fuel. Drain fuel and replace with fresh fuel. Let unit stand for 10 minutes.
Re-install module or contact technical support.
Push choke knob in. Clean or replace air filter. Replace fuel filter. Clean spark arrestor. Recharge generator battery. Fill fuel tank. Fill crankcase to the proper level. Place generator on a flat, level surface. Move generator to an open, outdoor area. Point exhaust away from people and buildings. Move to fresh air and get medical help if sick, dizzy, or weak.

If equipped, when CO Shield® shutoffs occur due to accumulating carbon monoxide (CO) and if the red LED light blinks on the panel.
If equipped, when CO Shield® shutoffs occur due to system fault and if the yellow LED light blinks on the panel. Clogged spark arrestor.

Make sure there are no objects creating obstructions within 5 feet of the generator. Obstructions in the vicinity of the generator may trap carbon monoxide emissions near the generator and cause the engine to shutoff.
If the generator’s exhaust is facing into the wind, the exhaust may be blown back into the generator’s operating area, creating an accumulation of CO emissions and triggering an engine shutoff. To avoid an engine shutoff, turn the generator 45° in either direction to allow the exhaust emissions to blow away from the generator. If engine shutoff events continue, readjust and align the exhaust with the wind direction to blow away from the generator.
Start by confirming yellow LED light blinks when/ if generator shuts off. If CO Shield® continues to sense the fault and shuts off, contact technical support.
Clean spark arrestor.

36

201161 – 12,000W TRI-FUEL PORTABLE GENERATOR

TROUBLESHOOTING

Problem

Cause

Engine starts and shuts off right away.

If equipped, when CO Shield® shutoffs occur due to accumulating carbon monoxide (CO) and if the red LED light blinks on the panel.

If equipped, when CO Shield® shutoffs occur due to system fault and if the yellow LED light blinks on the panel.

Both CO Shield® LEDs not blinking 10 times upon start up.

Starting the generator within 1 minute after being manually shutoff, not a CO shutoff event.

Generator cannot supply enough power or overheating.
Engine is running but no AC output.

Generator is overloaded.
Dirty air filter. Choke in wrong position. Poor cord connection. Circuit breaker is open. Loose wiring.
GFCI tripped.

Engine hunts or falters.

Other. Engine governor defective. Dirty fuel filter. Choke in wrong position.

Overload.

Repeated circuit breaker tripping.

Faulty power cords or device.

Circuit breaker still too hot.

For other issues and technical support:
Technical Support Team Toll Free 1-877-338-0999 support@championpowerequipment.com
37

Solution Move generator to an open, outdoor area. Point exhaust away from people and buildings. Move to fresh air and get medical help if sick, dizzy, or weak.
Make sure there are no objects creating obstructions within 5 feet of the generator. Obstructions in the vicinity of the generator may trap carbon monoxide emissions near the generator and cause the engine to shutoff.
If the generator’s exhaust is facing into the wind, the exhaust may be blown back into the generator’s operating area, creating an accumulation of CO emissions and triggering an engine shutoff. To avoid an engine shutoff, turn the generator 45° in either direction to allow the exhaust emissions to blow away from the generator. If engine shutoff events continue, readjust and align the exhaust with the wind direction to blow away from the generator. Start by confirming yellow LED light blinks when/ if generator shuts off. If CO Shield® continues to sense the fault and shuts off, contact technical support. Wait 1 minute before trying to restart the generator. The LEDs should then blink ten (10) times. Review load and adjust. See “Connecting Electrical Loads.” Clean or replace air filter. Push choke knob in. Check all connections. Reset circuit breaker. Check all circuit breakers. Inspect and tighten wiring connections. Reset GFCI receptacle breakers by first pushing the TEST button then the RESET button until green LED illuminates. Contact the help line. Contact the help line. Contact the help line. Replace fuel filter. Push choke knob in. Review load and adjust. See “Connecting Electrical Loads.” Check for damaged, bare or frayed wires. Replace defective device. Let unit sit for 5 minutes.

WARRANTY*
CHAMPION POWER EQUIPMENT 3 YEAR LIMITED WARRANTY
Warranty Qualifications
To register your product for warranty and FREE lifetime call center technical support please visit: https://www.championpowerequipment.com/register To complete registration you will need to include a copy of the purchase receipt as proof of original purchase. Proof of purchase is required for warranty service. Please register within ten (10) days from date of purchase.
Repair/Replacement Warranty
CPE warrants to the original purchaser that the mechanical and electrical components will be free of defects in material and workmanship for a period of three years (parts and labor) from the original date of purchase and 270 days (parts and labor) for commercial and industrial use. Transportation charges on product submitted for repair or replacement under this warranty are the sole responsibility of the purchaser. This warranty only applies to the original purchaser and is not transferable.
Do Not Return The Unit To The Place Of Purchase
Contact CPE’s Technical Service and CPE will troubleshoot any issue via phone or e-mail. If the problem is not corrected by this method, CPE will, at its option, authorize evaluation, repair or replacement of the defective part or component at a CPE Service Center. CPE will provide you with a case number for warranty service. Please keep it for future reference. Repairs or replacements without prior authorization, or at an unauthorized repair facility, will not be covered by this warranty.
Warranty Exclusions
This warranty does not cover the following repairs and equipment: Normal Wear Products with mechanical and electrical components need periodic parts and service to perform well. This warranty does not cover repair when normal use has exhausted the life of a part or the equipment as a whole. Installation, Use and Maintenance This warranty will not apply to parts and/or labor if the product is deemed to have been misused, neglected, involved in an accident, abused, loaded beyond the product’s limits, modified, installed improperly or connected incorrectly to any electrical component. Normal maintenance is not covered by this warranty and is not required to be performed at a facility or by a person authorized by CPE.

Other Exclusions
This warranty excludes:
­ Cosmetic defects such as paint, decals, etc.
­ Wear items such as filter elements, o-rings, etc.
­ Accessory parts such as starting batteries, and storage covers.
­ Failures due to acts of God and other force majeure events beyond the manufacturer’s control.
­ Problems caused by parts that are not original Champion Power Equipment parts.
­ Used for prime power in place of existing utility power (where utility power is present) or in place of utility power where utility power service does not normally exist. Prime power includes any application that does not use the utility grid for electric power (example: solar power).
Limits of Implied Warranty and Consequential Damage
Champion Power Equipment disclaims any obligation to cover any loss of time, use of this product, freight, or any incidental or consequential claim by anyone from using this product. THIS WARRANTY AND THE ATTACHED U.S. EPA and/or CARB EMISSION CONTROL SYSTEM WARRANTIES (WHEN APPLICABLE) ARE IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. A unit provided as an exchange will be subject to the warranty of the original unit. The length of the warranty governing the exchanged unit will remain calculated by reference to the purchase date of the original unit. This warranty gives you certain legal rights which may change from state to state or province to province. Your state or province may also have other rights you may be entitled to that are not listed within this warranty.
Contact Information
Address Champion Power Equipment, Inc. 6370 S Pioneer Way, Unit 101 Las Vegas, NV 89113 USA www.championpowerequipment.com Customer Service Toll Free: 1-877-338-0999 info@championpowerequipment.com Fax no.: 1-562-236-9429 Technical Service Toll Free: 1-877-338-0999 tech@championpowerequipment.com EMERGENCY 24 HOUR SUPPORT: 1-562-204-1188

*Except as otherwise stipulated in any of the following enclosed Emission Control System Warranties (when applicable) for the Emission Control System: U.S. Environment Protection Agency (EPA) and/or California Air Resources Board (CARB).

CHAMPION POWER EQUIPMENT, INC. (CPE) AND THE UNITED STATES ENVIRONMENT PROTECTION AGENCY (U.S. EPA)
EMISSION CONTROL SYSTEM WARRANTY
Your Champion Power Equipment (CPE) engine complies with U.S. EPA emission regulations.
YOUR WARRANTY RIGHTS AND OBLIGATIONS:
The U.S. EPA and CPE are pleased to explain the Federal Emission Control Systems Warranty on your 2024 small off-road engine (SORE) and engine powered equipment. New engines and equipment must be designed, built and equipped, at the time of sale, to meet U.S. EPA regulations for small off-road engines (SORE). CPE warrants the emission control system on your small off-road engine (SORE) and equipment for the period of time listed below, provided there has been no abuse, neglect, unapproved modification, or improper maintenance of your equipment.
Your emission control system may include parts such as the carburetor, fuel- injection system, the ignition system, catalytic converter and fuel lines. Also included may be hoses, belts, connectors and other emission related assemblies. Where a warrantable condition exits, CPE will repair your small off-road engine (SORE) at no cost to you including diagnosis, parts and labor.
MANUFACTURER’S EMISSION CONTROL SYSTEM WARRANTY COVERAGE:
This emission control system is warranted for two years, subject to provisions set forth below. If, during the warranty period, an emission related part on your engine is defective in materials or workmanship, the part will be repaired or replaced by CPE.
OWNER WARRANTY RESPONSIBILITIES:
As the small off-road engine (SORE) owner, you are responsible for the performance of the required maintenance listed in your Owner’s Manual. CPE recommends that you retain all your receipts covering maintenance on your small off-road engine (SORE), but CPE cannot deny warranty solely for the lack of receipts or for your failure to ensure the performance of all scheduled maintenance.
As the small off-road engine (SORE) owner, you should however be aware that CPE may deny you warranty coverage if your small, off-road engine (SORE) or a part has failed due to abuse, neglect, improper maintenance or unapproved modifications.
You are responsible for presenting your small off-road engine (SORE) to an Authorized CPE service outlet or alternate service outlet as described in (3)(f.) below, CPE dealer or CPE, Las Vegas, NV. as soon as a problem exists. The warranty repairs should be completed in a reasonable amount of time, not to exceed 30 days.
If you have any questions regarding your warranty rights and responsibilities, you should contact:
Champion Power Equipment, Inc. Customer Service
6370 S Pioneer Way, Unit 101 Las Vegas, NV 89113 1-877-338-0999
tech@championpowerequipment.com

EMISSION CONTROL SYSTEM WARRANTY
The following are specific provisions relative to your Emission Control System (ECS) Warranty Coverage. 1. APPLICABILITY: This warranty shall apply to 1997 and later model year small off-road engines (SORE). The ECS Warranty Period shall
begin on the date the new engine or equipment is delivered to its original, end-use purchaser, and shall continue for 24 consecutive months thereafter. 2. GENERAL EMISSIONS WARRANTY COVERAGE CPE warrants to the original, end-use purchaser of the new engine or equipment and to each subsequent purchaser that each of its small off-road engines (SORE) is:
2a. Designed, built and equipped so as to conform to U.S. EPA emissions standards for spark-ignited engines at or below 19 kilowatts.
2b. Free from defects in materials and workmanship that cause the failure of a warranted part to be identical in all material respects to the part as described in the engine manufacturer’s application for certification for a period of two years.
3. THE WARRANTY ON EMISSION-RELATED PARTS WILL BE INTERPRETED AS FOLLOWS:
3a. Any warranted part that is not scheduled for replacement as required maintenance in the Owners Manual shall be warranted for the ECS Warranty Period. If any such part fails during the ECS Warranty Period, it shall be repaired or replaced by CPE according to Subsection “d” below. Any such part repaired or replaced under the ECS Warranty shall be warranted for any remainder of the ECS Warranty Period.
3b. Any warranted, emissions-related part which is scheduled only for regular inspection as specified in the Owners Manual shall be warranted for the ECS Warranty Period. A statement in such written instructions to the effect of “repair or replace as necessary”, shall not reduce the ECS Warranty Period. Any such part repaired or replaced under the ECS Warranty shall be warranted for the remainder of the ECS Warranty Period.
3c. Any warranted, emissions-related part which is scheduled for replacement as required maintenance in the Owner’s Manual shall be warranted for the period of time prior to the first scheduled replacement point for that part. If the part fails prior to the first scheduled replacement, the part shall be repaired or replaced by CPE according to Subsection “d” below. Any such emissionsrelated part repaired or replaced under the ECS Warranty, shall be warranted for the remainder of the ECS Warranty Period prior to the first scheduled replacement point for such emissions-related part.
3d. Repair or replacement of any warranted, emissions-related part under this ECS Warranty shall be performed at no charge to the owner at a CPE Authorized Service Outlet.
3e. The owner shall not be charged for diagnostic labor which leads to the determination that a part covered by the ECS Warranty is in fact defective, provided that such diagnostic work is performed at a CPE Authorized Service Outlet.
3f. CPE shall pay for covered emissions warranty repairs at non-authorized service outlets under the following circumstances:
i. The service is required in a population center with a population over 100,000 according to U.S. Census 2000 without a CPE Authorized Service Outlet AND
ii.The service is required more than 100 miles from a CPE Authorized Service Outlet. The 100 mile limitation does not apply in the following states: Alaska, Arizona, Colorado, Hawaii, Idaho, Montana, Nebraska, Nevada, New Mexico, Oregon, Texas, Utah and Wyoming.
3g. CPE shall be liable for damages to other original engine components or approved modifications proximately caused by a failure under warranty of an emission-related part covered by the ECS Warranty.
3h. Throughout the ECS Warranty Period, CPE shall maintain a supply of warranted emission-related parts sufficient to meet the expected demand for such emission-related parts.
3i. Any CPE Authorized and approved emission-related replacement part may be used in the performance of any ECS Warranty maintenance or repair and will be provided without charge to the owner. Such use shall not reduce CPE’s warranty obligation.
3j. Unapproved add-on or modified parts may not be used to modify or repair a CPE engine. Such use voids this ECS Warranty and shall be sufficient grounds for disallowing an ECS Warranty claim. CPE shall not be liable hereunder for failures of any warranted parts of a CPE engine caused by the use of such an unapproved add-on or modified part.

EMISSION-RELATED PARTS INCLUDE THE FOLLOWING: (using those portions of the list applicable to the engine)

Systems covered by this warranty
Fuel Metering System Air Induction System Ignition System Exhaust System Miscellaneous Parts Evaporative Emissions

Parts Description
Fuel regulator, Carburetor and internal parts Air cleaner, Intake manifold Spark plug and parts, Magneto ignition system Exhaust manifold, catalytic converter Tubing, Fittings, Seals, Gaskets, and Clamps associated with these listed systems. Fuel Tank, Fuel Cap, Fuel Line (for liquid fuel and fuel vapors), Fuel Line Fittings, Clamps, Pressure Relief Valves, Control Valves, Control Solenoids, Electronic Controls, Vacuum Control Diaphragms, Control Cables, Control Linkages, Purge Valves, Gaskets, Vapor Hoses, Liquid/Vapor Separator, Carbon Canister, Canister Mounting Brackets, Carburetor Purge Port Connector

TO OBTAIN WARRANTY SERVICE:
You must take your CPE engine or the product on which it is installed, along with your warranty registration card or other proof of original purchase date, at your expense, to any Champion Power Equipment dealer who is authorized by Champion Power Equipment, Inc. to sell and service that CPE product during his normal business hours. Alternate service locations defined in Section (3)(f.) above must be approved by CPE prior to service. Claims for repair or adjustment found to be caused solely by defects in material or workmanship will not be denied because the engine was not properly maintained and used.
If you have any questions regarding your warranty rights and responsibilities, or to obtain warranty service, please write or call Customer Service at Champion Power Equipment, Inc.
Champion Power Equipment, Inc. 6370 S Pioneer Way, Unit 101 Las Vegas, NV 89113 1-877-338-0999 Attn.: Customer Service
tech@championpowerequipment.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

CHAMPION POWER EQUIPMENT User Manuals

Related Manuals