WHITE KNIGHT PXU060 Double Diaphragm Pump Owner’s Manual

June 16, 2024
WHITE KNIGHT

WHITE-KNIGHT-LOGO

WHITE KNIGHT PXU060 Double Diaphragm Pump

Product Information

Specifications & Performance

Model| Max Flow Rate| Displacement Per Cycle| Cycles per min| Air Connection| Weight| Suction Lift| Sound Pressure| Power
---|---|---|---|---|---|---|---|---
PXU060| 65.7 lpm (17.36 gpm)| 0.216 liters (0.057 gal)| 366 max| 1/4 in| 13.7 kg (30.3 lb)| 1 m (3 ft)| 68.6 dB(a) at 100 psi 50 CPM
82.12 dB(a) at 100 psi max CPM| 60.66 dB(a) at 100 psi 50 CPM
73.35 dB(a) at 100 psi max CPM
PXUSD060| 65.7 lpm (17.36 gpm)| 0.216 liters (0.057 gal)| 366 max| 1/4 in| 13.7 kg (30.3 lb)| Flooded suction| 68.6 dB(a) at 100 psi 50 CPM
82.12 dB(a) at 100 psi max CPM| 60.66 dB(a) at 100 psi 50 CPM
73.35 dB(a) at 100 psi max CPM

Product Usage Instructions

Installation
Before installing your White Knight PXU060 pump, please follow these steps:

  1. Ensure you have all necessary tools and equipment for installation.
  2. Select a suitable location for the pump that is close to the fluid source.
  3. Securely mount the pump using appropriate brackets or fasteners.
  4. Connect the air supply line to the air connection port of the pump.
  5. Connect the fluid inlet and outlet lines to their respective ports on the pump.
  6. Check all connections for leaks and tighten if necessary.

Control & Monitoring
To control and monitor your White Knight PXU060 pump, please follow these steps:

  1. Connect the pump to a suitable power source.
  2. Use the provided control panel or interface to adjust the desired flow rate and operating parameters.
  3. Monitor the pump’s performance and status using the built-in indicators or external monitoring devices.
  4. Regularly check the pump for any abnormal sounds, vibrations,or leaks, and take appropriate action if necessary.

Ordering Instructions

If you need to order additional parts or accessories for your White Knight PXU060 pump, please follow these steps:

  1. Refer to the product manual for a list of available parts and accessories.
  2. Contact our customer support team via phone or email to place your order.
  3. Provide the model number and specific part or accessory you require.
  4. Confirm the order details, including quantity and shipping address.
  5. Make the necessary payment for the order.

Pump Service

If your White Knight PXU060 pump requires service or maintenance, please follow these steps:

Rebuild Kits & Parts

  1. Contact our customer support team to determine the specific rebuild kit or parts you need.
  2. Place an order for the required rebuild kit or parts.
  3. Follow the instructions provided with the rebuild kit to disassemble the pump.
  4. Replace the worn or damaged parts with the new ones from the rebuild kit.
  5. Reassemble the pump following the reverse order of disassembly.

Return Pump for Service

  1. Contact our customer support team to initiate the return process for pump service.
  2. Follow the instructions provided by our team to properly package and ship the pump.
  3. Include all necessary information, such as contact details and a description of the issue.
  4. Ship the pump to the designated service center using a reliable shipping method.
  5. Once the pump is received and evaluated, our team will perform the necessary repairs or maintenance.

Warranty & Accessories
Your White Knight PXU060 pump is covered by a warranty. For more information about the warranty and available accessories, please refer to the product manual or contact our customer support team.

FAQ

Q: How do I calculate the displacement of the pump?
A: To calculate the displacement per cycle, divide the flow rate by the cycles per minute (CPM).

Q: What is the recommended installation level for the pump?
A: It is recommended to install the pump at a level less than 3 ft above the fluid source.

Q: Can the PXUSD060 pump be used in dry-run applications?
A: No, the PXUSD060 pumps are not dry-run capable and require flooded suction. Dry-run operation may void the warranty. Please contact our support team for more information.

187 E. 670 S., Kamas, UT 84036
435.783.6040 888.796.2476
https://wkfluidhandling.com

Dear valued customer,

Thank you for purchasing a White Knight PXU060 pump.
Our dedicated team designs products to meet your exacting specifications with a demonstrated commitment to quality that goes beyond mere words and fancy slogans.
Our patented designs offer a variety of size and material options to meet stringent requirements of high-pressure chemical delivery systems, hightemperature re-circulation processes, chemical reclaim and bulk transport applications, slurry systems, and more. Our safe, reliable products offer superior performance, optimized efficiency, and simplified maintenance.
White Knight is able to provide the highest quality fluid handling products through controlled, consistent in-house engineering and manufacturing.
Through continued significant investments in engineering and manufacturing, we lead the industry with new technologies and products.
White Knight has received numerous awards for innovation and manufacturing programs. We rigorously manage our quality assurance processes to ensure consistency and reliability. Our quality controls include strict cleanliness procedures and consistent manufacturing processes. For example, high-purity product assembly, testing, and packaging is performed in a Class 100 cleanroom.
Please peruse this manual before installing your White Knight product.

It details installation requirements and setup instructions, and provides additional information and accessories for enhanced functionality.
Our team has gone to great lengths to ensure our products serve your needs and meet your requirements.
Further, we provide the highest quality products at the best value, and we back them up with excellent warranties and world class support.
Thank you for your confidence and trust in White Knight products. Sincerely,White Knight Fluid Handling

Product Information

Specifications & Performance

Model PXU060 PXUSD060
**Max Flow Rate*** 65.7 lpm (17.36 gpm) 65.7 lpm (17.36 gpm)
**Displacement Per Cycle*** 0.216 liters (0.057 gal) 0.216 liters (0.057

gal)
Cycles per min| 366 max| 366 max
Air Connection| 1/4 in| 1/4 in
Weight| 13.7 kg (30.3 lb)| 13.7 kg (30.3 lb)
**Suction Lift*| 1 m (3 ft)| Flooded suction
Sound| Pressure****| 68.6 dB(a) at 100 psi 50 CPM

82.12 dB(a) at 100 psi max CPM

Power**| 60.66 dB(a) at 100 psi 50 CPM

73.35 dB(a) at 100 psi max CPM

May vary by configuration or system. Suction lift diminishes over time. Recommended installation level less than 3 ft above source. To calculate displacement, divide flow rate by CPM.
Sound measured in accordance with ISO9614-2:1997.
Dry-run capable PXUSD060 pumps require flooded suction and may have reduced warranty. Contact support for details.

Max Fluid Temperature 210°C (412°F)
Environmental Temperature min: 0°C (32°F) max: 50°C (122°F)
Max Supply Air Pressure 7 Bar (100 psi)
Min Startup Air Pressure 1.4 Bar (20 psi)
Fluid Path Materials PTFE, PFA
Non-Fluid Path Materials PTFE, PFA, SS
Stroke Detection Proximity stroke detection
--- ---
Leak Detection Fiber optic with or without sensor, or conductivity
Electronic Control CPC, CPT, or custom. Call for details.

PXU060 Performance

How to Read Charts
Draw a horizontal line at your discharge pressure and vertical line at desired flow rate.
At line intersect, estimate required air pressure,resultant cycle rate and air consumption.

WHITE-KNIGHT-PXU060-Double-Diaphragm-Pump-Fig- \(1\)

PXUSD060 Performance

Example
At 2 Bar (30 psi) discharge pressure and 60 psi supply pressure, PXU060 pumps provide 36 lpm (9.5 gpm) flow rates. They would cycle at 225 CPM and exhaust 20 SCFM of air.

Graph is for reference only. Performance was measured utilizing 1/2 in (3/8 in ID) air line and 1-1/4 in (1-1/8 in ID) liquid lines with 1 ft flooded suction. Performance may vary in your system.

Temperature Limits

WHITE-KNIGHT-PXU060-Double-Diaphragm-Pump-Fig- \(2\)

Dimensions

Dimensions in [mm] in

WHITE-KNIGHT-PXU060-Double-Diaphragm-Pump-Fig- \(3\)

WHITE-KNIGHT-PXU060-Double-Diaphragm-Pump-Fig- \(4\)

Bill of Materials

PXU060F BILL OF MATERIALS

Item| Part Number| Description| Qty.
1| 1125-TE-0021| Pump Body| 1
2| 2127-TE-0033| Head, Right| 1
3| 2127-TE-0034| Head, Left| 1
4| 3200-VI-0001| Diaphragm, .782| 2
5| 4100-PF-0001| PFA Check Ball .765″| 4
6| 4135-MP-0014| Bottom Check Seat, Lower| 2
7| 4137-TE-0010| Bottom Check Cage| 2
8| 4137-TE-0011| Middle Check Cage| 4
9| 4139-TE-0005| Cage, Plug| 2
10| 4140-TE-0006| Top Check Plug| 2
11| 4142-MP-0008| Top Check Seat, Upper| 2
12| 4142-TE-0013| Top Check Cage| 2
13| 5143-MP-0004| Seal, Shaft| 2
14| 6090-UH-0003| Body, QEH, 05| 2
15| 6140-FP-0002| Baffle Porous Poly L QEV| 4
16| 6140-PP-0004| Mesh, QEV 04 & 05| 6
17| 6150-NP-0007| Cap, Muffler, QEV| 2
18| 6150-UH-0001| Seat, QEV Exhaust| 2
19| 7400-PF-0002| Insert, S-300®| 2
20| 7400-PF-0006| Nut, S-300®, 3/4″| 2
21| 7400-TE-0004| Body, S-300®, 3/4″| 2
22| 8110-BP-0001| Shipping Cap For Prox Pumps| 2
23| 8110-TE-0006| Housing, Sensor| 2
24| 8200-TE-0001| Adapter, Cap, Proximity| 2
25| 8600-XX-0057| Sensor, Proximity| 2
26| 10010-TE-0018| Screw, Mount, Plate, Base| 2
27| 10010-TE-0019| Nut, Jam| 2
28| 10040-TE-0003| Plug, NPT, 1/4″| 2
29| 10040-TE-0006| Plug, 5/8″, .300″| 4
30| 10080-VI-016-75| O-ring, 016 x .070| 2
31| 10080-VI-019-75| O-ring, .019 x .070| 2
32| 14200-TE-0003| Plate, Base, Assembly| 1
33| 14300-PF-0013| Bellows Assembly| 2
34| 14320-PF-0004| Shaft| 1
Leak Detect

Part| Description
14600-XX-0009| LF0| 15 ft fiber optic cable with no amplifier
14600-XX-0010| LF1| 15 ft fiber optic cable with D10 amplifier
14600-XX-0011| LF2| 25 ft fiber optic cable with no amplifier
14600-XX-0012| LF3| 25 ft fiber optic cable with D10 amplifier
14600-XX-0031| LC0| 15 ft conductivity cable
14600-XX-0040| LC1| 25 ft conductivity cable
Stroke Detect

Part| Description
14700-XX-0039| SX1| 15 ft PNP normally

open proximity switch

WHITE-KNIGHT-PXU060-Double-Diaphragm-Pump-Fig-
\(5\)

WHITE-KNIGHT-PXU060-Double-Diaphragm-Pump-Fig-
\(6\)

Installation

Precautions

Handling
Do NOT lift pump by proximity cables,quick exhaust valves nor air tubing.

Installation Orientation
PXU060 pumps must be installed in an upright position. The check valves are actuated by gravity and/or flow, and they will not seat if the pump is not upright. Do not install pumps within 3 ft of each other or it may interfere with proximity sensors.

Timer Mode
PXU060 pumps require an end of stroke detection mechanism (pressure switch) to prevent over stroking in timer mode.
Operating a PXU060 in timer mode without stroke detection will void the pump warranty.

Required Air Flow (Shuttle Valve)
PXU060 pumps require 1/4 in minimum orifice with unrestricted air flow.

Required Air Flow (Solenoid Valve)
PXU060 pumps require a 1.5 Cv solenoid.
Using a reduced Cv will reduce flow rates.
Using a valve with more than 20% greater Cv will change operating parameters, reduce pump life and void the warranty.

Under Supply of Air
PXU060 pumps operate erratically or stall when air supply is insufficient. Ensure use of air supply pressures higher than averaged air consumption lines in performance charts.
Air supply lines and fittings must meet minimal inner diameter requirements shown in the installation instructions.

Air Supply Pressure
Operating PXU060 pumps ~35% below max air pressure may significantly extend pump life. PXU060 pumps require 20 psi minimum air pressure. Operation above 7 Bar (100 psi) may damage the pump and void the warranty.

Using Proximity Sensors
Pumps using a proximity sensor are not intrinsically safe and do not qualify for use in explosion-proof environments.

Suction Lift
PXU060 pumps have initial suction lift of 3 ft. For best results minimize suction lift.

Liquid Inlet/Outlet Connections
PXU060 liquid ports are not NPT nor any other standard. Use of connectors other than those supplied by White Knight will damage the pump and void the warranty.

Liquid Line Restriction
PXU060 pumps may be controlled by closing liquid outlet lines. However,restricting liquid supply lines increases wear and should be avoided. Do NOT pump against a closed liquid inlet. It will damage the pump and void the warranty.

Running Dry
PXU060 pumps use the pumped liquid to lubricate their shafts. The pumps will cycle faster and wear more than normal when run dry, which may cause damage and loss of self-prime abilities. Standard models should not be run dry after startup and are not warrantied under dry run conditions. Dry-run capable PXUSD060 models may run dry for short periods.
Warranty of dry-run models is one-year.
Extended warranties are available.
Pulse Dampener with Shuttle Valve Air supply pressure to PXU060 pumps should be at least ten psi higher than the liquid line pressure when using a pulsation dampener. Failure to do so may cause erratic operation.

Cross Contamination
PXU060 pumps use porous material that may retain chemicals. Take precautions to avoid cross contamination.

Warnings
Pressurized Material
Pumps in use contain pressurized materials.
Eliminate liquid and air pressure via shut off valves before pump is serviced or removed from the system.

High Temperature
Heat may transfer to exterior surfaces when pumps operate with high temperature fluids.
Avoid direct contact with the pump when high temperature fluids are present.

Hazardous Chemical
Use appropriate personal protective equipment when handling pump. Reference Material Safety Data Sheet (MSDS) for information specific to your chemicals.

Loud Noise
Pump exhaust air contributes to work area noise levels. Only operate pumps with approved muffler media, and use ear protection in noisy conditions.

Advantages

Head Pressure / Dead-Head
PXU060 pumps can be controlled by adjusting their liquid outlet pressures and can be installed with head pressures up to dead-head (e.g. equal liquid and air pressures) with no damage to the pump.

Thermal Cycling
PXU060 pumps require no maintenance when operated within their performance range, even in thermal cycling applications.

Environment & System

Oversized Inlet Line
Pumps operate optimally with liquid inlet lines larger than the liquid outlet lines. This reduces strain on the bellows and may reduce pulsation in the pump outlet.

Clean Supply Air (CDA)
PXU060 pumps require use of Class 2 air for particles and moisture per ISO 8573-1.
Use 10 micron filter; maintain -40°C dew point. A point-of-use filter is recommended during first six months of operation in new fabs/systems due to high risks of debris that can damage pumps and void warranty.

Flammable Solvents
PXU060 pumps are not constructed from conductive materials. System that pump flammable solvents should be properly grounded to avoid ignition by static charge.
A River’s Edge test of isolative pumps with flammable liquids indicated that liquids must be grounded and other procedures should be followed. Copy of test available.
Pumping Liquids Near Boiling Point Minimizing suction lift reduces pulsation and the potential for boiling or outgassing of liquid in the inlet of the pump. Although reciprocating pumps can pull suction lift,pump performance and life increase when suction lift is minimized or eliminated.

Abrasive Slurry
Pumping abrasive slurry may accelerate wear of components. PXU060 pumps are warrantied when used with slurry. However,normal wear is not covered by warranty.

Environmental Temperature
PXU060 pumps are rated for 0°C (32°F) -50°C (122°F) environmental temperatures.
Do not freeze fluid in pump. Operation below 0°C may accelerate wear. Normal wear is not covered by warranty.

Proximity Sensor Installation

Proximity sensors ship already installed in their housings.
Follow steps 2.1-2.3 if sensors are removed from their housings.

WHITE-KNIGHT-PXU060-Double-Diaphragm-Pump-Fig- \(7\)

  1. Remove QEV plug.

  2. Attach QEV. Thread in NPT.
    Do not overtighten.

  3. Ensure proximity sensor is properly installed in housing.
    Tighten to light contact. Tighten lock nut to housing.

  4. Attach sensor assembly to pump head.
    Use a crescent wrench to tighten cap.
    Tighten to bottom out. Do not overtighten.

  5. Repeat steps for both pump heads.

Sensor Installation

WHITE-KNIGHT-PXU060-Double-Diaphragm-Pump-Fig- \(8\)

D10 amplifier must be calibrated before attaching fiber optic probes to the pump.

Installation Instructions

Pull-back dismount is standard. See steps 3.1-3.3 for forward dismount.

  1. Set lever to up position. Slide base plate forward or pump body backward.
  2. Lift pump off of base plate.
  3. Screw base plate to surface with 3/8 in or 10 mm socket head cap screws into pre-drilled holes.
  4. Set pump on base knobs; slide it forward. Set lever to down position.
  5. Attach fittings to pump. Tighten to 55 inch-lbs.
  6. Attach tubes and fittings per manufacturer instructions. Use backer wrench to hold fitting in place at pump.
  7. Set air line via 1/4 in FNPT ports on quick exhaust valves. Line must be 1/4 in minimum orifice.

WHITE-KNIGHT-PXU060-Double-Diaphragm-Pump-Fig-\(9\)

Push-Forward Dismount Configuration Setup
Replace step 4 with steps 3.1-3.3 to re-configure the base plate to push- forward dismount.

WHITE-KNIGHT-PXU060-Double-Diaphragm-Pump-Fig- \(10\)

Install with Rigid Base Plate*Requires push-forward dismount configuration (steps 3.1-3.3)

WHITE-KNIGHT-PXU060-Double-Diaphragm-Pump-Fig- \(11\)

Liquid Inlet/Outlet
Liquid ports are not NPT nor any other standard. Use of connectors other than those supplied by White Knight will damage the pump.

Control & Monitoring

Programmable Control
White Knight CPT-1 controllers monitor and adjust run mode, flow rate, leak detection and other pump operations.

D10 Amplifier Electrical Hookups & Dimensions
White Knight recommends Expert™ D10 amplifier for use with fiber optic stroke and leak detection assemblies.

WHITE-KNIGHT-PXU060-Double-Diaphragm-Pump-Fig- \(13\) WHITE-KNIGHT-PXU060-Double-Diaphragm-Pump-Fig-
\(14\)

Proximity Detection Wiring Information

  • 10-30 V DC
  • ≤ 200 mA
  • NPN-normally open
  • Listed IND.CONT.EQ 81u2
  • For use in the secondary of a Class 2 source of supply
  • Use of Proximity Sensors does not qualify for intrinsically safe environments.

Shift Logic for Proximity Pumps

Air must be sent to either side at startup to initiate movement.

During pump operation, the timing of the solenoid valve should be dependent on sensors with no time delays. There should be no delay between reading the sensor signal and actuating the solenoid valve.

WHITE-KNIGHT-PXU060-Double-Diaphragm-Pump-Fig- \(16\)

Proximity End Stroke Operation

WHITE-KNIGHT-PXU060-Double-Diaphragm-Pump-Fig- \(17\)

The proximity sensors on the pump can both be seen in the middle of the stroke; thus it is required that the solenoid not be switched until just one sensor is seen.
Vertical line denotes when the solenoid was switched.

Conductivity Leak Detection Installation
Leaks are identified if conductive fluid contacts a sensor. Sensor provides a Sink (NPN) or Source (PNP) signal, depending on the wire setup. See the wiring diagrams below.
Conductive leak detection does not qualify for use in explosion-proof environments. Conductive fluid required.
See below for elbow out configuration.

WHITE-KNIGHT-PXU060-Double-Diaphragm-Pump-Fig- \(18\)

Fiber Optic Leak Detection Installation
D10 amplifier must be calibrated before attaching fiber optic probes to the pump. Fiber optic sensors can melt if used at >130°C (266°F), causing leak detect failure.

See below for elbow out configuration.

  1. Remove leak adapter and leak detect probe from fiber optic assembly.
  2. For straight out configuration replace NPT plug in “L” port with the probe. Hand-tighten.
  3. Insert the fiber optic cable until it contacts the bottom of the probe.
  4. Lower ferrule and gripper until snug against the probe. Hand tighten female gripper nut.
  5. Open the top and slide the front face of the D10 up. Press the fiber optic ends into the holes on its front. Slide the face down to lock cables in place.

WHITE-KNIGHT-PXU060-Double-Diaphragm-Pump-Fig- \(19\)

WHITE-KNIGHT-PXU060-Double-Diaphragm-Pump-Fig- \(20\)

Calibrating D10 Amplifier for Fiber Optic Leak Detection

WHITE-KNIGHT-PXU060-Double-Diaphragm-Pump-Fig- \(21\)

Step 3: Set Sensing Condition
Set condition to “leak detection” sensing while probe tip is submerged in liquid. Then, remove the leak probe from liquid and reinserted into the “L” port. Amplifier will now signal when moisture if detected on the probe tip.

WHITE-KNIGHT-PXU060-Double-Diaphragm-Pump-Fig- \(22\)

Ordering Instructions

Options 1-3 are required. Leave Additional Options blank if not desired. Only add Outlet if different than Inlet.

WHITE-KNIGHT-PXU060-Double-Diaphragm-Pump-Fig- \(24\)

Pump Service

Pumps fully rebuilt by White Knight, certified rebuilders, or technicians certified by White Knight receive full warranty renewal. Details below.

White Knight Rebuilds
Request factory rebuilds by web form at: https://wkfluidhandling.com/support/rma/. An RMA# will be provided after processing.
*Customers must follow decontamination instructions in Section 4.4 when returning a pump to White Knight.

Certified Rebuilders
White Knight’s global network of certified rebuilders expedite rebuild turn- around time and minimize shipping costs. Find certified rebuilders at: https://wkfluidhandling.com/rebuilders/

Rebuild Pump as Certified Technician
White Knight offers trainings to certify technicians to rebuild pumps. Technicians who pass the training are issued a two-year certification. During the two years, parts in pumps rebuilt by the technician receive a full warranty. See: https://wkfluidhandling.com/virtual-rebuilds/

Rebuild Kits & Parts
Rebuild kit for PXU060F is RBPXU060F-1. Rebuild kit for PXUSD060F is RBPXUSD060F-1 (labor not included). To request rebuilds by White Knight, use RBPXU060F-5 or RBPXUSD060F-5, respectively (labor included).

Pump rebuilds require tool kit: 12200-XX-0033 (Legacy# PXU060-170)
Dry-run (SD) pumps use different shaft and shaft seals. Contact White Knight for details.

WHITE-KNIGHT-PXU060-Double-Diaphragm-Pump-Fig- \(25\)

RBPXU060F-1

ITEM NO. PART NUMBER DESCRIPTION QTY.
1 3200-VI-0001 DIAPHRAGM,          .782 2
2 4135-MP-0014 BOTTOM CHECK SEAT, LOWER 2
3 4137-TE-0010 BOTTOM CHECK CAGE, 10 GPM 2
4 4137-TE-0011 MIDDLE CHECK CAGE, 10 GPM 4
5 4142-MP-0008 TOP CHECK SEAT, UPPER 2
6 4142-TE-0013 TOP CHECK CAGE, 10 GPM 2
7 5143-MP-0004 SEAL, SHAFT, U-SERIES, 60L 2
8 6140-FP-0002 BAFFLE, .800″ 4
9 6150-UH-0001 SEAT, QEV EXHAUST, 30L & 60L 2
10 14300-MP-0022 BELLOWS ASSEMBLLY, 60L U-SERIES, PROXIMITY 2
11 14320-PF-0004 LOADED SHAFT ASSEMBLY, 60L, U-SERIES, CERAMIC 1
12 4100-PF-0001 PFA CHECK BALL 3/4″ 4

Return Pump for Service

Follow decontamination instructions when returning a pump for service.

DO NOT REMOVE PAGE FROM MANUAL.
Copy page from manual or download at https://wkfluidhandling.com/support/rma/.

Decontamination Instructions
PRINT COMPLETED DECONTAMINATION CERTIFICATION. IT MUST BE INCLUDED IN YOUR RMA SHIPMENT.
White Knight products are designed for use with caustic and otherwise dangerous liquids. Handle every product as if it contains dangerous chemicals whether or not it actually does.

  • Only those with adequate safety training should attempt to handle used pumps.
  • Wear adequate safety gear appropriate for chemicals that have been in the pump.
  • Review relevant Material Safety Data Sheets (MSDS) before handling the pump.
  • Review emergency numbers for use in event of an accident.
  • Prepare Ph papers, showers, antidotes, clean-up equipment, neutralizers, and other safety devices used to detect, neutralize or minimize effects of chemicals described in appropriate MSDS documents.

Rinse with DI Water
Circulate DI water through pump for twenty minutes before disassembly and/or double bagging for shipment. If pump is nonfunctional, force DI water from inlet through outlet for 40 minutes before shipment preparations.

Remove Pump from Station:

  1. Disconnect liquid tubing connectors from front of pump (opposite shuttle valve).
  2. Plug NPT fittings with PTFE plug, Flare fittings with flare nose cover and cap, or other plug or cap as recommended by connector supplier.
  3. Disconnect air supply tubing from face of shuttle valve.
  4. Loosen mount screw from base plate. (Note: do not remove screw from base plate).
  5. Remove base plate using proper tool for the fastening devices (e.g. Allen wrench or screw driver). Note: Base plate may stay if needed for replacement pump to be used.
  6. Return all removed parts to the pump.

Return Pump to White Knight:

  1. Rinse pump with DI water as described above after removing it from its station.
  2. Drain remaining DI water from the pump inlet and outlet liquid tubing connectors.
  3. Plug liquid outlets as described in the Remove Pump from Station section above.
  4. Dry the pump, double bag it, and seal it in thick polyethylene bags.
  5. Return the pump to its original packaging.
  6. Include MSDS for the chemical that the pump was handling in the box with the pump.
  7. Obtain RMA number from White Knight and write it on the outside of the box.
  8. Ship to White Knight following all rules, regulations and laws regarding shipment of dangerous materials. Ship freight pre-paid. No collect shipments will be accepted. Unauthorized use of White Knight shipping accounts will result in the adding of freight to the bill in addition to a service charge.

Include All Pump Components:
Pumps returned to White Knight for evaluation, service or repair must be complete with all components, including but not limited to base plate, mount screws, tubing connectors, tubing connector caps, flare noses, shuttle valves, mufflers, and tubing. Missing parts will be added to the pump and charged to the customer.

DO NOT REMOVE PAGE FROM MANUAL.
Copy page from manual or download at https://wkfluidhandling.com/support/rma/.

Decontamination Certification
COMPLETE AND PRINT THIS FORM. IT MUST BE INCLUDED IN YOUR RMA SHIPMENT.
I, the undersigned employee of , certify that all decontamination and safety procedures described in Decontamination Instructions section have been followed for return of product below.

RMA#:
(We cannot process returns without an RMA number.)

Serial#:
(We cannot process returns without a product serial number.)

Metal Exposure:
(Check all that apply. Write in other metals if necessary.)

Product was used in a Metal Process. Yes No
Product was used in a Copper Metal Process. Yes No

Product was used with:
Aluminum Cobalt Gold Lead Nickel Platinum Silver Tin Titanium

Tungsten Zinc Other:

Chemical Exposure:
(Check all that apply. Write in other chemicals if necessary.)
Product was NOT used in chemicals (DI Water only).
Product was used in chemicals.
Ammonia Ammonium Hydroxide Hydrochloric Acid Hydrofluoric Acid Hydrogen Peroxide IPA

Nitric Acid Phosphoric Acid Sulfuric Acid Other:

Shipping Information:
Please indicate metal processes to which the product has been exposed by clearly and conspicuously labeling the outside of the return package with the metal.

Products exposed to Metal Processes must be sent to the following address:

White Knight Fluid Handling
187 East 670 South, Suite B
Kamas, UT 84036

Products NOT exposed to Metal Processes must be sent to the following address:

White Knight Fluid Handling
187 East 670 South, Suite C
Kamas, UT 84036

Print Name:
Signature: Date:

Warranty

White Knight follows strict manufacturing, assembly and testing procedures to ensure consistency and reliability.
White Knight warrants PXU060 pumps and components are free from defects in materials and workmanship for two years from our shipment date or your installation date if provided within 90 days of shipment from our facility.
Failures due to normal wear, misuse, abuse or unauthorized disassembly nullify this warranty.
White Knight does not guarantee the suitability of products for specific applications. White Knight is not liable for any damage or expense resulting from use or misuse of its products in any application. Responsibility is limited solely to repair or replacement of defective products or components.
Prior written, faxed or emailed approval must be obtained from White Knight before returning any product or component for warranty consideration.
All determinations regarding cause of failure are made by White Knight, and all decisions regarding warranty fulfillment or nullification are made by White Knight.
THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED, INCLUDING ANY GUARANTEE OF SUITABILITY FOR ANY PURPOSE. NO VARIATIONS OF THIS WARRANTY SHALL BE HONORED NOR CONSIDERED LEGALLY BINDING, EXCEPT WRITTEN AGREEMENTS SIGNED BY THE CEO OF WHITE KNIGHT FLUID HANDLING.

Accessories

See ordering instructions or contact us for details.

Stroke Detection

  • Fiber Optic stroke detection with or without sensor
  • Solid state pressure switch
  • Solid state dual pressure switch

Leak Detection

  • Fiber Optic leak detection with or without sensor
  • Conductivity leak detection

CPT-1

  • Control/monitor run mode and flow rate.

Catcher™ Pre-Filters

  • In-line and pump-mounted options
  • Large through holes to avoid loading
  • Filter may be removed without removing the Catcher™ from the pump or the line.
  • Pumps damaged by passing solids that use a Catcher™ are repaired as in warranty.

Filter Housing

  • 100% non-metallic
  • Allows for filter changing without disconnecting the inlet/outlet lines
  • Rated for temperatures up to 210°C
  • Install with industry standard connections
  • Designed to allow for thermal cycling
  • Upright and inverted installation options

Quick Exhaust Valves

  • Allows for immediate escape of exhaust air reducing pulsation and exposure of solenoid valve to corrosive fumes
  • In-line and pump-mounted options
  • UHMW-PE design
  • Comes standard with a one-year warranty

Pulse Dampeners

  • Uses same CDA as supplied to pump
  • In-line and pump-mounted options
  • Sizes available for all PXU Series pumps
  • Self-adjusting, Auto-Level Valve is regulated by liquid line pressure

CERTIFICATE & DECLARATION OF CONFORMITY FOR CE MARKING
Company contact details:
White Knight Fluid Handling Inc.
187 E. 670 S., Kamas, Utah, 84036, USA
White Knight Fluid Handling Inc. declares that their:

Bellows Pump Line
PSA030, PSA060, PSA140, PSH030, PSH060, PSH140, PSU030, PSU060, PSU140, PSA015, PSR050, PSR025, PFA030,PFAD60, PFA140, PFH030, PFH060, PFH140, PFU030, PFU060, PFU140, PXAD30, PXA060, PXA140, PXH030, PXH060,PXH140, PXU030, PXU060, PXU140, PFAD 15, LHAD15, LHA030, LHAD7O

Diaphragm Pump Line (Non Conductive)
PSD04TE, PSD06TE, PSD08TE, PSD16TE, PSD24TE, PSD04UH, PSD06UH, PSD08UH, PSD16UH, PSD24UH, PSB100

Diaphragm Pump Line (Conductive)|
PSD04TC, PSD06TC, PSD08TC, PSD16TC, PSD24TC, PSD04UC, PSDOGUC, PSDO8UC, PSD16UC, PSD24UC

Legacy Pump Line
PLS30, PLS60, PLS120, PLX30, PLX60, PLX120, PX30, PX60, PX120, PLF30, PLF60, PLF120

Metering Pumps
PPM100, PEM100, PEM050

Plastic Pumps
PHC40-2, PPMC300, PPMA
TPA07 Pressure Transducer are classified within the following EU Directives as applicable:
Machinery Directive 2006/42/EC
Low Voltage Directive 2014/35/EU
Eletromagnetic Compatibility Directive 2014/30/EU
RoHS 2 Directive 2011/65/EU and further conform with the following EU Harmonized Standards as applicable:
EN 809:1998+A1:2009 EN 60204-1:2006 + A1:2009
EN 61000-6-2:2005 EN 61000-6-4:2007+A1:2011
Dated: 16 January 2017
Position of signatory: Product Manager
Name of Signatory: Cory Ammon Simmons
Signed below: on behalf of White Knight Fluid Handling Inc.

White Knight Support
187 E. 670 S.
Kamas, UT 84036
Phone: 435.783.6040
Toll Free: 888.796.2476
Fax: 435.783.6128
support@wkfluidhandling.com
https://wkfluidhandling.com/support/

Copyright © 2023 White Knight Fluid Handling | A Graco company
P: 435.783.6040 | support@wkfluidhandling.com | https://wkfluidhandling.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

WHITE KNIGHT User Manuals

Related Manuals