WHITE KNIGHT PXU060 Double Diaphragm Pump Owner’s Manual
- June 16, 2024
- WHITE KNIGHT
Table of Contents
WHITE KNIGHT PXU060 Double Diaphragm Pump
Product Information
Specifications & Performance
Model| Max Flow Rate| Displacement Per Cycle| Cycles per min| Air Connection|
Weight| Suction Lift| Sound Pressure| Power
---|---|---|---|---|---|---|---|---
PXU060| 65.7 lpm (17.36 gpm)| 0.216 liters (0.057 gal)| 366 max| 1/4 in| 13.7
kg (30.3 lb)| 1 m (3 ft)| 68.6 dB(a) at 100 psi 50 CPM
82.12 dB(a) at 100 psi max CPM| 60.66 dB(a) at 100 psi 50 CPM
73.35 dB(a) at 100 psi max CPM
PXUSD060| 65.7 lpm (17.36 gpm)| 0.216 liters (0.057 gal)| 366 max| 1/4 in|
13.7 kg (30.3 lb)| Flooded suction| 68.6 dB(a) at 100 psi 50 CPM
82.12 dB(a) at 100 psi max CPM| 60.66 dB(a) at 100 psi 50 CPM
73.35 dB(a) at 100 psi max CPM
Product Usage Instructions
Installation
Before installing your White Knight PXU060 pump, please follow these steps:
- Ensure you have all necessary tools and equipment for installation.
- Select a suitable location for the pump that is close to the fluid source.
- Securely mount the pump using appropriate brackets or fasteners.
- Connect the air supply line to the air connection port of the pump.
- Connect the fluid inlet and outlet lines to their respective ports on the pump.
- Check all connections for leaks and tighten if necessary.
Control & Monitoring
To control and monitor your White Knight PXU060 pump, please follow these
steps:
- Connect the pump to a suitable power source.
- Use the provided control panel or interface to adjust the desired flow rate and operating parameters.
- Monitor the pump’s performance and status using the built-in indicators or external monitoring devices.
- Regularly check the pump for any abnormal sounds, vibrations,or leaks, and take appropriate action if necessary.
Ordering Instructions
If you need to order additional parts or accessories for your White Knight PXU060 pump, please follow these steps:
- Refer to the product manual for a list of available parts and accessories.
- Contact our customer support team via phone or email to place your order.
- Provide the model number and specific part or accessory you require.
- Confirm the order details, including quantity and shipping address.
- Make the necessary payment for the order.
Pump Service
If your White Knight PXU060 pump requires service or maintenance, please follow these steps:
Rebuild Kits & Parts
- Contact our customer support team to determine the specific rebuild kit or parts you need.
- Place an order for the required rebuild kit or parts.
- Follow the instructions provided with the rebuild kit to disassemble the pump.
- Replace the worn or damaged parts with the new ones from the rebuild kit.
- Reassemble the pump following the reverse order of disassembly.
Return Pump for Service
- Contact our customer support team to initiate the return process for pump service.
- Follow the instructions provided by our team to properly package and ship the pump.
- Include all necessary information, such as contact details and a description of the issue.
- Ship the pump to the designated service center using a reliable shipping method.
- Once the pump is received and evaluated, our team will perform the necessary repairs or maintenance.
Warranty & Accessories
Your White Knight PXU060 pump is covered by a warranty. For more information
about the warranty and available accessories, please refer to the product
manual or contact our customer support team.
FAQ
Q: How do I calculate the displacement of the pump?
A: To calculate the displacement per cycle, divide the flow rate by the
cycles per minute (CPM).
Q: What is the recommended installation level for the pump?
A: It is recommended to install the pump at a level less than 3 ft above
the fluid source.
Q: Can the PXUSD060 pump be used in dry-run applications?
A: No, the PXUSD060 pumps are not dry-run capable and require flooded
suction. Dry-run operation may void the warranty. Please contact our support
team for more information.
187 E. 670 S., Kamas, UT 84036
435.783.6040 888.796.2476
https://wkfluidhandling.com
Dear valued customer,
Thank you for purchasing a White Knight PXU060 pump.
Our dedicated team designs products to meet your exacting specifications with
a demonstrated commitment to quality that goes beyond mere words and fancy
slogans.
Our patented designs offer a variety of size and material options to meet
stringent requirements of high-pressure chemical delivery systems,
hightemperature re-circulation processes, chemical reclaim and bulk transport
applications, slurry systems, and more. Our safe, reliable products offer
superior performance, optimized efficiency, and simplified maintenance.
White Knight is able to provide the highest quality fluid handling products
through controlled, consistent in-house engineering and manufacturing.
Through continued significant investments in engineering and manufacturing, we
lead the industry with new technologies and products.
White Knight has received numerous awards for innovation and manufacturing
programs. We rigorously manage our quality assurance processes to ensure
consistency and reliability. Our quality controls include strict cleanliness
procedures and consistent manufacturing processes. For example, high-purity
product assembly, testing, and packaging is performed in a Class 100
cleanroom.
Please peruse this manual before installing your White Knight product.
It details installation requirements and setup instructions, and provides
additional information and accessories for enhanced functionality.
Our team has gone to great lengths to ensure our products serve your needs and
meet your requirements.
Further, we provide the highest quality products at the best value, and we
back them up with excellent warranties and world class support.
Thank you for your confidence and trust in White Knight products.
Sincerely,White Knight Fluid Handling
Product Information
Specifications & Performance
Model | PXU060 | PXUSD060 |
---|---|---|
**Max Flow Rate*** | 65.7 lpm (17.36 gpm) | 65.7 lpm (17.36 gpm) |
**Displacement Per Cycle*** | 0.216 liters (0.057 gal) | 0.216 liters (0.057 |
gal)
Cycles per min| 366 max| 366 max
Air Connection| 1/4 in| 1/4 in
Weight| 13.7 kg (30.3 lb)| 13.7 kg (30.3 lb)
**Suction Lift*| 1 m (3 ft)| Flooded suction
Sound| Pressure****| 68.6 dB(a) at 100 psi 50 CPM
82.12 dB(a) at 100 psi max CPM
Power**| 60.66 dB(a) at 100 psi 50 CPM
73.35 dB(a) at 100 psi max CPM
May vary by configuration or system. Suction lift diminishes over time.
Recommended installation level less than 3 ft above source. To calculate
displacement, divide flow rate by CPM.
Sound measured in accordance with ISO9614-2:1997.
Dry-run capable PXUSD060 pumps require flooded suction and may have reduced
warranty. Contact support for details.
Max Fluid Temperature | 210°C (412°F) |
---|---|
Environmental Temperature | min: 0°C (32°F) max: 50°C (122°F) |
Max Supply Air Pressure | 7 Bar (100 psi) |
Min Startup Air Pressure | 1.4 Bar (20 psi) |
Fluid Path Materials | PTFE, PFA |
Non-Fluid Path Materials | PTFE, PFA, SS |
Stroke Detection | Proximity stroke detection |
--- | --- |
Leak Detection | Fiber optic with or without sensor, or conductivity |
Electronic Control | CPC, CPT, or custom. Call for details. |
PXU060 Performance
How to Read Charts
Draw a horizontal line at your discharge pressure and vertical line at desired
flow rate.
At line intersect, estimate required air pressure,resultant cycle rate and air
consumption.
PXUSD060 Performance
Example
At 2 Bar (30 psi) discharge pressure and 60 psi supply pressure, PXU060 pumps
provide 36 lpm (9.5 gpm) flow rates. They would cycle at 225 CPM and exhaust
20 SCFM of air.
Graph is for reference only. Performance was measured utilizing 1/2 in (3/8 in ID) air line and 1-1/4 in (1-1/8 in ID) liquid lines with 1 ft flooded suction. Performance may vary in your system.
Temperature Limits
Dimensions
Dimensions in [mm] in
Bill of Materials
PXU060F BILL OF MATERIALS
Item| Part Number| Description| Qty.
1| 1125-TE-0021| Pump Body| 1
2| 2127-TE-0033| Head, Right| 1
3| 2127-TE-0034| Head, Left| 1
4| 3200-VI-0001| Diaphragm, .782| 2
5| 4100-PF-0001| PFA Check Ball .765″| 4
6| 4135-MP-0014| Bottom Check Seat, Lower| 2
7| 4137-TE-0010| Bottom Check Cage| 2
8| 4137-TE-0011| Middle Check Cage| 4
9| 4139-TE-0005| Cage, Plug| 2
10| 4140-TE-0006| Top Check Plug| 2
11| 4142-MP-0008| Top Check Seat, Upper| 2
12| 4142-TE-0013| Top Check Cage| 2
13| 5143-MP-0004| Seal, Shaft| 2
14| 6090-UH-0003| Body, QEH, 05| 2
15| 6140-FP-0002| Baffle Porous Poly L QEV| 4
16| 6140-PP-0004| Mesh, QEV 04 & 05| 6
17| 6150-NP-0007| Cap, Muffler, QEV| 2
18| 6150-UH-0001| Seat, QEV Exhaust| 2
19| 7400-PF-0002| Insert, S-300®| 2
20| 7400-PF-0006| Nut, S-300®, 3/4″| 2
21| 7400-TE-0004| Body, S-300®, 3/4″| 2
22| 8110-BP-0001| Shipping Cap For Prox Pumps| 2
23| 8110-TE-0006| Housing, Sensor| 2
24| 8200-TE-0001| Adapter, Cap, Proximity| 2
25| 8600-XX-0057| Sensor, Proximity| 2
26| 10010-TE-0018| Screw, Mount, Plate, Base| 2
27| 10010-TE-0019| Nut, Jam| 2
28| 10040-TE-0003| Plug, NPT, 1/4″| 2
29| 10040-TE-0006| Plug, 5/8″, .300″| 4
30| 10080-VI-016-75| O-ring, 016 x .070| 2
31| 10080-VI-019-75| O-ring, .019 x .070| 2
32| 14200-TE-0003| Plate, Base, Assembly| 1
33| 14300-PF-0013| Bellows Assembly| 2
34| 14320-PF-0004| Shaft| 1
Leak Detect
Part| Description
14600-XX-0009| LF0| 15 ft fiber optic cable with no amplifier
14600-XX-0010| LF1| 15 ft fiber optic cable with D10 amplifier
14600-XX-0011| LF2| 25 ft fiber optic cable with no amplifier
14600-XX-0012| LF3| 25 ft fiber optic cable with D10 amplifier
14600-XX-0031| LC0| 15 ft conductivity cable
14600-XX-0040| LC1| 25 ft conductivity cable
Stroke Detect
Part| Description
14700-XX-0039| SX1| 15 ft PNP normally
open proximity switch
Installation
Precautions
Handling
Do NOT lift pump by proximity cables,quick exhaust valves nor air tubing.
Installation Orientation
PXU060 pumps must be installed in an upright position. The check valves are
actuated by gravity and/or flow, and they will not seat if the pump is not
upright. Do not install pumps within 3 ft of each other or it may interfere
with proximity sensors.
Timer Mode
PXU060 pumps require an end of stroke detection mechanism (pressure switch) to
prevent over stroking in timer mode.
Operating a PXU060 in timer mode without stroke detection will void the pump
warranty.
Required Air Flow (Shuttle Valve)
PXU060 pumps require 1/4 in minimum orifice with unrestricted air flow.
Required Air Flow (Solenoid Valve)
PXU060 pumps require a 1.5 Cv solenoid.
Using a reduced Cv will reduce flow rates.
Using a valve with more than 20% greater Cv will change operating parameters,
reduce pump life and void the warranty.
Under Supply of Air
PXU060 pumps operate erratically or stall when air supply is insufficient.
Ensure use of air supply pressures higher than averaged air consumption lines
in performance charts.
Air supply lines and fittings must meet minimal inner diameter requirements
shown in the installation instructions.
Air Supply Pressure
Operating PXU060 pumps ~35% below max air pressure may significantly extend
pump life. PXU060 pumps require 20 psi minimum air pressure. Operation above 7
Bar (100 psi) may damage the pump and void the warranty.
Using Proximity Sensors
Pumps using a proximity sensor are not intrinsically safe and do not qualify
for use in explosion-proof environments.
Suction Lift
PXU060 pumps have initial suction lift of 3 ft. For best results minimize
suction lift.
Liquid Inlet/Outlet Connections
PXU060 liquid ports are not NPT nor any other standard. Use of connectors
other than those supplied by White Knight will damage the pump and void the
warranty.
Liquid Line Restriction
PXU060 pumps may be controlled by closing liquid outlet lines.
However,restricting liquid supply lines increases wear and should be avoided.
Do NOT pump against a closed liquid inlet. It will damage the pump and void
the warranty.
Running Dry
PXU060 pumps use the pumped liquid to lubricate their shafts. The pumps will
cycle faster and wear more than normal when run dry, which may cause damage
and loss of self-prime abilities. Standard models should not be run dry after
startup and are not warrantied under dry run conditions. Dry-run capable
PXUSD060 models may run dry for short periods.
Warranty of dry-run models is one-year.
Extended warranties are available.
Pulse Dampener with Shuttle Valve Air supply pressure to PXU060 pumps should
be at least ten psi higher than the liquid line pressure when using a
pulsation dampener. Failure to do so may cause erratic operation.
Cross Contamination
PXU060 pumps use porous material that may retain chemicals. Take precautions
to avoid cross contamination.
Warnings
Pressurized Material
Pumps in use contain pressurized materials.
Eliminate liquid and air pressure via shut off valves before pump is serviced
or removed from the system.
High Temperature
Heat may transfer to exterior surfaces when pumps operate with high
temperature fluids.
Avoid direct contact with the pump when high temperature fluids are present.
Hazardous Chemical
Use appropriate personal protective equipment when handling pump. Reference
Material Safety Data Sheet (MSDS) for information specific to your chemicals.
Loud Noise
Pump exhaust air contributes to work area noise levels. Only operate pumps
with approved muffler media, and use ear protection in noisy conditions.
Advantages
Head Pressure / Dead-Head
PXU060 pumps can be controlled by adjusting their liquid outlet pressures and
can be installed with head pressures up to dead-head (e.g. equal liquid and
air pressures) with no damage to the pump.
Thermal Cycling
PXU060 pumps require no maintenance when operated within their performance
range, even in thermal cycling applications.
Environment & System
Oversized Inlet Line
Pumps operate optimally with liquid inlet lines larger than the liquid outlet
lines. This reduces strain on the bellows and may reduce pulsation in the pump
outlet.
Clean Supply Air (CDA)
PXU060 pumps require use of Class 2 air for particles and moisture per ISO
8573-1.
Use 10 micron filter; maintain -40°C dew point. A point-of-use filter is
recommended during first six months of operation in new fabs/systems due to
high risks of debris that can damage pumps and void warranty.
Flammable Solvents
PXU060 pumps are not constructed from conductive materials. System that pump
flammable solvents should be properly grounded to avoid ignition by static
charge.
A River’s Edge test of isolative pumps with flammable liquids indicated that
liquids must be grounded and other procedures should be followed. Copy of test
available.
Pumping Liquids Near Boiling Point Minimizing suction lift reduces pulsation
and the potential for boiling or outgassing of liquid in the inlet of the
pump. Although reciprocating pumps can pull suction lift,pump performance and
life increase when suction lift is minimized or eliminated.
Abrasive Slurry
Pumping abrasive slurry may accelerate wear of components. PXU060 pumps are
warrantied when used with slurry. However,normal wear is not covered by
warranty.
Environmental Temperature
PXU060 pumps are rated for 0°C (32°F) -50°C (122°F) environmental
temperatures.
Do not freeze fluid in pump. Operation below 0°C may accelerate wear. Normal
wear is not covered by warranty.
Proximity Sensor Installation
Proximity sensors ship already installed in their housings.
Follow steps 2.1-2.3 if sensors are removed from their housings.
-
Remove QEV plug.
-
Attach QEV. Thread in NPT.
Do not overtighten. -
Ensure proximity sensor is properly installed in housing.
Tighten to light contact. Tighten lock nut to housing. -
Attach sensor assembly to pump head.
Use a crescent wrench to tighten cap.
Tighten to bottom out. Do not overtighten. -
Repeat steps for both pump heads.
Sensor Installation
D10 amplifier must be calibrated before attaching fiber optic probes to the pump.
Installation Instructions
Pull-back dismount is standard. See steps 3.1-3.3 for forward dismount.
- Set lever to up position. Slide base plate forward or pump body backward.
- Lift pump off of base plate.
- Screw base plate to surface with 3/8 in or 10 mm socket head cap screws into pre-drilled holes.
- Set pump on base knobs; slide it forward. Set lever to down position.
- Attach fittings to pump. Tighten to 55 inch-lbs.
- Attach tubes and fittings per manufacturer instructions. Use backer wrench to hold fitting in place at pump.
- Set air line via 1/4 in FNPT ports on quick exhaust valves. Line must be 1/4 in minimum orifice.
Push-Forward Dismount Configuration Setup
Replace step 4 with steps 3.1-3.3 to re-configure the base plate to push-
forward dismount.
Install with Rigid Base Plate*Requires push-forward dismount configuration (steps 3.1-3.3)
Liquid Inlet/Outlet
Liquid ports are not NPT nor any other standard. Use of connectors other than
those supplied by White Knight will damage the pump.
Control & Monitoring
Programmable Control
White Knight CPT-1 controllers monitor and adjust run mode, flow rate, leak
detection and other pump operations.
D10 Amplifier Electrical Hookups & Dimensions
White Knight recommends Expert™ D10 amplifier for use with fiber optic stroke
and leak detection assemblies.
Proximity Detection Wiring Information
- 10-30 V DC
- ≤ 200 mA
- NPN-normally open
- Listed IND.CONT.EQ 81u2
- For use in the secondary of a Class 2 source of supply
- Use of Proximity Sensors does not qualify for intrinsically safe environments.
Shift Logic for Proximity Pumps
Air must be sent to either side at startup to initiate movement.
During pump operation, the timing of the solenoid valve should be dependent on sensors with no time delays. There should be no delay between reading the sensor signal and actuating the solenoid valve.
Proximity End Stroke Operation
The proximity sensors on the pump can both be seen in the middle of the
stroke; thus it is required that the solenoid not be switched until just one
sensor is seen.
Vertical line denotes when the solenoid was switched.
Conductivity Leak Detection Installation
Leaks are identified if conductive fluid contacts a sensor. Sensor provides a
Sink (NPN) or Source (PNP) signal, depending on the wire setup. See the wiring
diagrams below.
Conductive leak detection does not qualify for use in explosion-proof
environments. Conductive fluid required.
See below for elbow out configuration.
Fiber Optic Leak Detection Installation
D10 amplifier must be calibrated before attaching fiber optic probes to the
pump. Fiber optic sensors can melt if used at >130°C (266°F), causing leak
detect failure.
See below for elbow out configuration.
- Remove leak adapter and leak detect probe from fiber optic assembly.
- For straight out configuration replace NPT plug in “L” port with the probe. Hand-tighten.
- Insert the fiber optic cable until it contacts the bottom of the probe.
- Lower ferrule and gripper until snug against the probe. Hand tighten female gripper nut.
- Open the top and slide the front face of the D10 up. Press the fiber optic ends into the holes on its front. Slide the face down to lock cables in place.
Calibrating D10 Amplifier for Fiber Optic Leak Detection
Step 3: Set Sensing Condition
Set condition to “leak detection” sensing while probe tip is submerged in
liquid. Then, remove the leak probe from liquid and reinserted into the “L”
port. Amplifier will now signal when moisture if detected on the probe tip.
Ordering Instructions
Options 1-3 are required. Leave Additional Options blank if not desired. Only add Outlet if different than Inlet.
Pump Service
Pumps fully rebuilt by White Knight, certified rebuilders, or technicians certified by White Knight receive full warranty renewal. Details below.
White Knight Rebuilds
Request factory rebuilds by web form at:
https://wkfluidhandling.com/support/rma/. An RMA# will be provided after
processing.
*Customers must follow decontamination instructions in Section 4.4 when returning a pump to White Knight.
Certified Rebuilders
White Knight’s global network of certified rebuilders expedite rebuild turn-
around time and minimize shipping costs. Find certified rebuilders at:
https://wkfluidhandling.com/rebuilders/
Rebuild Pump as Certified Technician
White Knight offers trainings to certify technicians to rebuild pumps.
Technicians who pass the training are issued a two-year certification. During
the two years, parts in pumps rebuilt by the technician receive a full
warranty. See: https://wkfluidhandling.com/virtual-rebuilds/
Rebuild Kits & Parts
Rebuild kit for PXU060F is RBPXU060F-1. Rebuild kit for PXUSD060F is
RBPXUSD060F-1 (labor not included). To request rebuilds by White Knight, use
RBPXU060F-5 or RBPXUSD060F-5, respectively (labor included).
Pump rebuilds require tool kit: 12200-XX-0033 (Legacy# PXU060-170)
Dry-run (SD) pumps use different shaft and shaft seals. Contact White Knight
for details.
RBPXU060F-1
ITEM NO. | PART NUMBER | DESCRIPTION | QTY. |
---|---|---|---|
1 | 3200-VI-0001 | DIAPHRAGM, .782 | 2 |
2 | 4135-MP-0014 | BOTTOM CHECK SEAT, LOWER | 2 |
3 | 4137-TE-0010 | BOTTOM CHECK CAGE, 10 GPM | 2 |
4 | 4137-TE-0011 | MIDDLE CHECK CAGE, 10 GPM | 4 |
5 | 4142-MP-0008 | TOP CHECK SEAT, UPPER | 2 |
6 | 4142-TE-0013 | TOP CHECK CAGE, 10 GPM | 2 |
7 | 5143-MP-0004 | SEAL, SHAFT, U-SERIES, 60L | 2 |
8 | 6140-FP-0002 | BAFFLE, .800″ | 4 |
9 | 6150-UH-0001 | SEAT, QEV EXHAUST, 30L & 60L | 2 |
10 | 14300-MP-0022 | BELLOWS ASSEMBLLY, 60L U-SERIES, PROXIMITY | 2 |
11 | 14320-PF-0004 | LOADED SHAFT ASSEMBLY, 60L, U-SERIES, CERAMIC | 1 |
12 | 4100-PF-0001 | PFA CHECK BALL 3/4″ | 4 |
Return Pump for Service
Follow decontamination instructions when returning a pump for service.
DO NOT REMOVE PAGE FROM MANUAL.
Copy page from manual or download at
https://wkfluidhandling.com/support/rma/.
Decontamination Instructions
PRINT COMPLETED DECONTAMINATION CERTIFICATION. IT MUST BE INCLUDED IN YOUR RMA
SHIPMENT.
White Knight products are designed for use with caustic and otherwise
dangerous liquids. Handle every product as if it contains dangerous chemicals
whether or not it actually does.
- Only those with adequate safety training should attempt to handle used pumps.
- Wear adequate safety gear appropriate for chemicals that have been in the pump.
- Review relevant Material Safety Data Sheets (MSDS) before handling the pump.
- Review emergency numbers for use in event of an accident.
- Prepare Ph papers, showers, antidotes, clean-up equipment, neutralizers, and other safety devices used to detect, neutralize or minimize effects of chemicals described in appropriate MSDS documents.
Rinse with DI Water
Circulate DI water through pump for twenty minutes before disassembly and/or
double bagging for shipment. If pump is nonfunctional, force DI water from
inlet through outlet for 40 minutes before shipment preparations.
Remove Pump from Station:
- Disconnect liquid tubing connectors from front of pump (opposite shuttle valve).
- Plug NPT fittings with PTFE plug, Flare fittings with flare nose cover and cap, or other plug or cap as recommended by connector supplier.
- Disconnect air supply tubing from face of shuttle valve.
- Loosen mount screw from base plate. (Note: do not remove screw from base plate).
- Remove base plate using proper tool for the fastening devices (e.g. Allen wrench or screw driver). Note: Base plate may stay if needed for replacement pump to be used.
- Return all removed parts to the pump.
Return Pump to White Knight:
- Rinse pump with DI water as described above after removing it from its station.
- Drain remaining DI water from the pump inlet and outlet liquid tubing connectors.
- Plug liquid outlets as described in the Remove Pump from Station section above.
- Dry the pump, double bag it, and seal it in thick polyethylene bags.
- Return the pump to its original packaging.
- Include MSDS for the chemical that the pump was handling in the box with the pump.
- Obtain RMA number from White Knight and write it on the outside of the box.
- Ship to White Knight following all rules, regulations and laws regarding shipment of dangerous materials. Ship freight pre-paid. No collect shipments will be accepted. Unauthorized use of White Knight shipping accounts will result in the adding of freight to the bill in addition to a service charge.
Include All Pump Components:
Pumps returned to White Knight for evaluation, service or repair must be
complete with all components, including but not limited to base plate, mount
screws, tubing connectors, tubing connector caps, flare noses, shuttle valves,
mufflers, and tubing. Missing parts will be added to the pump and charged to
the customer.
DO NOT REMOVE PAGE FROM MANUAL.
Copy page from manual or download at
https://wkfluidhandling.com/support/rma/.
Decontamination Certification
COMPLETE AND PRINT THIS FORM. IT MUST BE INCLUDED IN YOUR RMA SHIPMENT.
I, the undersigned employee of , certify that all decontamination and safety
procedures described in Decontamination Instructions section have been
followed for return of product below.
RMA#:
(We cannot process returns without an RMA number.)
Serial#:
(We cannot process returns without a product serial number.)
Metal Exposure:
(Check all that apply. Write in other metals if necessary.)
Product was used in a Metal Process. Yes No
Product was used in a Copper Metal Process. Yes No
Product was used with:
Aluminum Cobalt Gold Lead Nickel Platinum Silver Tin Titanium
Tungsten Zinc Other:
Chemical Exposure:
(Check all that apply. Write in other chemicals if necessary.)
Product was NOT used in chemicals (DI Water only).
Product was used in chemicals.
Ammonia Ammonium Hydroxide Hydrochloric Acid Hydrofluoric Acid Hydrogen
Peroxide IPA
Nitric Acid Phosphoric Acid Sulfuric Acid Other:
Shipping Information:
Please indicate metal processes to which the product has been exposed by
clearly and conspicuously labeling the outside of the return package with the
metal.
Products exposed to Metal Processes must be sent to the following address:
White Knight Fluid Handling
187 East 670 South, Suite B
Kamas, UT 84036
Products NOT exposed to Metal Processes must be sent to the following address:
White Knight Fluid Handling
187 East 670 South, Suite C
Kamas, UT 84036
Print Name:
Signature: Date:
Warranty
White Knight follows strict manufacturing, assembly and testing procedures to
ensure consistency and reliability.
White Knight warrants PXU060 pumps and components are free from defects in
materials and workmanship for two years from our shipment date or your
installation date if provided within 90 days of shipment from our facility.
Failures due to normal wear, misuse, abuse or unauthorized disassembly nullify
this warranty.
White Knight does not guarantee the suitability of products for specific
applications. White Knight is not liable for any damage or expense resulting
from use or misuse of its products in any application. Responsibility is
limited solely to repair or replacement of defective products or components.
Prior written, faxed or emailed approval must be obtained from White Knight
before returning any product or component for warranty consideration.
All determinations regarding cause of failure are made by White Knight, and
all decisions regarding warranty fulfillment or nullification are made by
White Knight.
THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES
EXPRESSED OR IMPLIED, INCLUDING ANY GUARANTEE OF SUITABILITY FOR ANY PURPOSE.
NO VARIATIONS OF THIS WARRANTY SHALL BE HONORED NOR CONSIDERED LEGALLY
BINDING, EXCEPT WRITTEN AGREEMENTS SIGNED BY THE CEO OF WHITE KNIGHT FLUID
HANDLING.
Accessories
See ordering instructions or contact us for details.
Stroke Detection
- Fiber Optic stroke detection with or without sensor
- Solid state pressure switch
- Solid state dual pressure switch
Leak Detection
- Fiber Optic leak detection with or without sensor
- Conductivity leak detection
CPT-1
- Control/monitor run mode and flow rate.
Catcher™ Pre-Filters
- In-line and pump-mounted options
- Large through holes to avoid loading
- Filter may be removed without removing the Catcher™ from the pump or the line.
- Pumps damaged by passing solids that use a Catcher™ are repaired as in warranty.
Filter Housing
- 100% non-metallic
- Allows for filter changing without disconnecting the inlet/outlet lines
- Rated for temperatures up to 210°C
- Install with industry standard connections
- Designed to allow for thermal cycling
- Upright and inverted installation options
Quick Exhaust Valves
- Allows for immediate escape of exhaust air reducing pulsation and exposure of solenoid valve to corrosive fumes
- In-line and pump-mounted options
- UHMW-PE design
- Comes standard with a one-year warranty
Pulse Dampeners
- Uses same CDA as supplied to pump
- In-line and pump-mounted options
- Sizes available for all PXU Series pumps
- Self-adjusting, Auto-Level Valve is regulated by liquid line pressure
CERTIFICATE & DECLARATION OF CONFORMITY FOR CE MARKING
Company contact details:
White Knight Fluid Handling Inc.
187 E. 670 S., Kamas, Utah, 84036, USA
White Knight Fluid Handling Inc. declares that their:
Bellows Pump Line
PSA030, PSA060, PSA140, PSH030, PSH060, PSH140, PSU030, PSU060, PSU140,
PSA015, PSR050, PSR025, PFA030,PFAD60, PFA140, PFH030, PFH060, PFH140, PFU030,
PFU060, PFU140, PXAD30, PXA060, PXA140, PXH030, PXH060,PXH140, PXU030, PXU060,
PXU140, PFAD 15, LHAD15, LHA030, LHAD7O
Diaphragm Pump Line (Non Conductive)
PSD04TE, PSD06TE, PSD08TE, PSD16TE, PSD24TE, PSD04UH, PSD06UH, PSD08UH,
PSD16UH, PSD24UH, PSB100
Diaphragm Pump Line (Conductive)|
PSD04TC, PSD06TC, PSD08TC, PSD16TC, PSD24TC, PSD04UC, PSDOGUC, PSDO8UC,
PSD16UC, PSD24UC
Legacy Pump Line
PLS30, PLS60, PLS120, PLX30, PLX60, PLX120, PX30, PX60, PX120, PLF30, PLF60,
PLF120
Metering Pumps
PPM100, PEM100, PEM050
Plastic Pumps
PHC40-2, PPMC300, PPMA
TPA07 Pressure Transducer are classified within the following EU Directives as
applicable:
Machinery Directive 2006/42/EC
Low Voltage Directive 2014/35/EU
Eletromagnetic Compatibility Directive 2014/30/EU
RoHS 2 Directive 2011/65/EU and further conform with the following EU
Harmonized Standards as applicable:
EN 809:1998+A1:2009 EN 60204-1:2006 + A1:2009
EN 61000-6-2:2005 EN 61000-6-4:2007+A1:2011
Dated: 16 January 2017
Position of signatory: Product Manager
Name of Signatory: Cory Ammon Simmons
Signed below: on behalf of White Knight Fluid Handling Inc.
White Knight Support
187 E. 670 S.
Kamas, UT 84036
Phone: 435.783.6040
Toll Free: 888.796.2476
Fax: 435.783.6128
support@wkfluidhandling.com
https://wkfluidhandling.com/support/
Copyright © 2023 White Knight Fluid Handling | A Graco company
P: 435.783.6040 |
support@wkfluidhandling.com |
https://wkfluidhandling.com
References
- White Knight Fluid Handling | High Purity Chemical Solutions
- Certified Service Providers - White Knight Fluid Handling
- Support RMA - White Knight Fluid Handling
- Virtual Rebuilds - White Knight Fluid Handling
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>