WHITE KNIGHT FHU01 Filter Housings Owner’s Manual

June 14, 2024
WHITE KNIGHT

WHITE-NIGHTS-LOGO

WHITE KNIGHT FHU01 Filter Housings

WHITE-KNIGHT-FHU01-Filter-Housings-PRODUCT - Copy

Product Information

Overview
The White Knight FHU01 filter housing is designed with advanced technologies to meet your filtration needs. It features drain/vent sealing technology, adjustable O-ring seals, and a low-pressure drop of 1 inch in the flow path. The filter housing is compatible with major filter cartridges and can accommodate filters with up to 3.2-inch diameter, providing a greater filtration surface area. It is easy to install in any orientation and comes with various fitting options. Please note that the filter is not provided by White Knight.

Temperature Limits

The FHU01 filter housing can withstand different temperature limits for drain/vent and air supply pressure. The drain/vent system is designed with two O-rings to ensure reliable seals and prevent leaks. The sealing pressure is adjustable beyond initial compression loads. The temperature limits for the drain/vent system are:

  • 90°C (maximum)
  • 60°C (recommended)

The air supply pressure should be maintained within the following limits:

  • 80 psi (maximum)
  • 30 psi (recommended)

Dimensions
The FHU01 filter housing has the following dimensions:

FHU01 (Standard Model):

Product Usage Instructions

Installation Instructions
To install the FHU01 filter housing, please follow these steps:

  1. Select a suitable location for installation.
  2. Ensure that the installation area is clean and free from debris.
  3. Choose the appropriate fitting option for your application.
  4. Connect the inlet and outlet pipes to the filter housing using the provided fittings.
  5. Tighten the fittings securely to prevent any leaks.
  6. If required, adjust the placement of the filter by using the adjustable pin.
  7. Ensure that the filter is properly seated and aligned within the filter housing.
  8. Verify that all connections are tight and secure.

Ordering Instructions
To order a White Knight FHU01 filter housing, please follow these instructions:

  1. Contact your local distributor or visit our website at https://wkfluidhandling.com.
  2. Provide the necessary information, such as the model number (FHU01), desired fitting options, and any additional accessories required.
  3. Confirm the order details, including quantity and delivery address.
  4. Make the payment as per the agreed terms.
  5. Once the order is processed, you will receive a confirmation and estimated delivery date.

Warranty
The White Knight FHU01 filter housing is covered by a warranty. Please refer to the warranty section in the owner’s manual for detailed terms and conditions.

Service
If you require any service or support for your FHU01 filter housing, please contact our customer support team at 435.783.6040 or email support@wkfluidhandling.com. Our team will be happy to assist you with any queries or issues you may have.

FAQ

Can I use filters from other brands with the FHU01 filter housing?
Yes, the FHU01 filter housing is designed to fit major filter cartridges, allowing you to use filters from various brands. Please ensure that the filter dimensions are compatible with the housing.

What is the recommended air supply pressure for the FHU01 filter housing?
The recommended air supply pressure for the FHU01 filter housing is 30 psi. However, it can withstand a maximum pressure of 80 psi.

How can I adjust the placement of the filter within the FHU01 filter housing?
The FHU01 filter housing comes with an adjustable pin that allows you to maintain the placement of the filter even when in an inverted position. Simply adjust the pin as needed to ensure proper alignment of the filter.

Dear valued customer,
Thank you for purchasing a White Knight FHU01 filter housing. Our dedicated team designs products to meet your exacting specifications with a demonstrated commitment to quality that goes beyond mere words and fancy slogans. Our patented designs offer a variety of sizes and material options to meet stringent requirements of high-pressure chemical delivery systems, high- temperature re-circulation processes, chemical reclaim and bulk transport applications, slurry systems, and more. Our safe, reliable products offer superior performance, optimized efficiency, and simplified maintenance.

White Knight can provide the highest quality fluid handling products through controlled, consistent in-house engineering and manufacturing. Through continued significant investments in engineering and manufacturing, we lead the industry with new technologies and products. White Knight has received numerous awards for innovation and manufacturing programs. We rigorously manage our quality assurance processes to ensure consistency and reliability. Our quality controls include strict cleanliness procedures and consistent manufacturing processes. For example, high-purity product assembly, testing, and packaging are performed in a Class 100 cleanroom.

Please peruse this manual before installing your White Knight product. It details installation requirements and setup instructions and provides additional information and accessories for enhanced functionality. Our team has gone to great lengths to ensure our products serve your needs and meet your requirements. Further, we provide the highest quality products at the best value, and we back them up with excellent warranties and world-class support. Thank you for your confidence and trust in White Knight products. Sincerely,

Tim White, CEO of White Knight Fluid Handling

Product Information

Overview
FHU01 filter housings fit standard filter cartridges offered by major suppliers. They provide high-flow performance, and reliable sealing that can be tightened after initial compression loads. These PTFE/PFA housings are nonmetal and enable changing filters without disconnecting liquid lines. They are capable of up to 210°C (410°F) fluid temperatures.WHITE-KNIGHT-FHU01
-Filter-Housings-FIG- \(1\)

Advanced Technologies

  • Fits major filter cartridges Reliable, adjustable O-ring seals
  • Synchro-Thread™ allows for fluids up to 210°C (410°F)
  • Greater filtration surface area with up to 3.2-in diameter filters
  • Easy to install in any orientation
  • Various fitting options
  • Adjustable pin maintains placement of filter when in an inverted position
  • Low-pressure drop (1-in flow path)
  • *Filter not provided by White Knight

Sealing Technology
Two O-rings ensure reliable seals to prevent leaks, improve reliability, and eliminate costly downtime and expensive cleanup. Sealing pressure is adjustable beyond initial compression loads.

Temperature LimitsWHITE-KNIGHT-FHU01-Filter-Housings-
FIG-19

Dimensions

WHITE-KNIGHT-FHU01-Filter-Housings-FIG- \(2\) WHITE-
KNIGHT-FHU01-Filter-Housings-FIG- \(3\) WHITE-
KNIGHT-FHU01-Filter-Housings-FIG- \(4\)

FHU01 (Standard Model)

Wrench Tool (Two shown) Part# 12100-PV-0022

Bill of MaterialsWHITE-KNIGHT-FHU01-Filter-Housings-FIG-
\(6\)

Part Number Description Qty
1 11100-TE-0008 Filter Housing Body
2 11100-TE-0009 Inverted Base
3 11100-MP-0001 Bellows Screw-short
4 10040-TE-0001 Bellows Cap
5 10010-TE-0012 Bellows Screw
6 10010-TE-0011 Bellows Screw Nut
7 10080-XX-244 -244 FEP

Encapsulated O-ring

| 1
8| 10080-XX-241| -241 FEP

Encapsulated O-ring

| 1
9| 14570-PF-0006| 30 gpm, 3/4 Prime Lock Fitting Assembly| 2
10| 11100-MP-0002| Bellows screw-long| 1
11| 14530-PF-0010| 3/8”-04 Super Pillar 300 Fitting Assembly| 3
12| 12100-PV-0022| Spanner Wrench| 2
13| 12100-PV-0042| Top check plug torque wrench adapter| 1
Liquid Fittings| Assemblies| Body Inlet Only

(Nut not included)

---|---|---
Flaretek Compatible| 1/2 in.| F08| 14510-PF-0011| 7200-PF-0015
3/4 in.| F12| 14510-PF-0008| 7200-PF-0009
1 in.| F16| 14510-PF-0009| 7200-PF-0010
1-1/4 in.| F20| 14510-PF-0010| 7200-PF-0011
Pillar S-300



| 1/2 in.| P08| 14530-PF-0011| 7400-TE-0019
3/4 in.| P12| 14530-PF-0006| 7400-TE-0006
1 in.| P16| 14530-PF-0007| 7400-TE-0007
1-1/4 in.| P20| 14530-PF-0008| 7400-TE-0008
1-1/2 in.| P24| 14530-PF-0026| 7400-TE-0035
PrimeLock| 3/4 in.| L12| 14570-PF-0006| 7800-TE-0006
1 in.| L16| 14570-PF-0007| 7800-TE-0007
1-1/4 in.| L20| TBD| 7800-TE-0008
Tube Out| 3/4 in.| T12| 7120-PF-0007
1 in.| T16| 7120-PF-0008
1-1/4 in.| T20| 7120-PF-0009
1-1/2 in.| T24| 7120-PF-0010
FNPT| 3/4 in.| N12| 7100-TE-0009
1 in.| N16| 7100-TE-0005
1-1/4 in.| N20| 7100-TE-0010
Weldable| 3/4 in.| W12| 7300-PF-0005
1 in.| W16| 7300-PF-0006
Synchro- Flare| 1/2 in.| S08| TBD| 7010-TE-0008
3/4 in.| S12| 14520-TE-0008| 7010-TE-0007
1 in.| S16| 14520-TE-0007| 7010-TE-0009
Plugged| B00| 7130-TE-0005| 7130-TE-0005
Drain/Vent Fittings| Assemblies| Body Inlet Only

(Nut not included)

---|---|---
Flaretek Compatible| 1/4 in.| F4| 14510-PF-0012| 7200-PF-0012
3/8 in.| F6| 14510-PF-0013| 7200-PF-0013


Pillar S-300

| 1/8 in.| P2| 14530-PF-0024| 7400-TE-0013
1/4 in.| P4| TBD| TBD
3/8 in.| P6| TBD| TBD
FNPT| 1/4 in.| N4| 7100-TE-0011
3/8 in.| N6| 7100-TE-0016
PrimeLock| 1/4 in.| L4| TBD| 7800-TE-0009
3/8 in.| L6| TBD| 7800-TE-0010
Plugged| B0| 7130-TE-0006

Installation Instructions

  1. Prepare the cabinet wall or other mounting panel by installing inserts for 3/8-UNC or 10mm socket head cap screws into the dimensions specified on the accompanying page. Recommended installation of the FHU01 is with the writing from the base in an upright position, viewable from the front. Holes drilled and tapped in plastic are not sufficient, considering the assembly weight of 19 lbs. (not including liquid or filter) and the forces of tightening and loosening the housing bowl (1).
  2. Install base (2) using four 3/8-UNC (or 10mm), minimum length of 1.75-in (45mm) plus mounting plate and nut thickness, stainless steel socket head cap (hex key/Allen wrench type) screws.
  3. Hook up inlet and outlet tubing as well as out-gassing vent lines as desired. If inlet and outlet tubing connectors are not of the type desired, do not attempt to modify or attempt to screw male NPT tubing connectors into the filter housing base. Irreparable damage to the base will occur. If a female NPT connection is desired, adapters are available from White Knight. If fittings are removed/replaced torque to the following values:
    • Inlet & Outlet – 80 in/lbs
    • Drain/Vent Fittings – 12.5 in/lbs.
  4. Loosen bellows nut (6) on screw (5) and turn the screw outward until bellows (3) can be completely compressed without seating on the screw.
  5. Insert filter into the FHU01 base (2).
  6. Check for proper placement of the diameter sealing encapsulated O-ring (9) in FHU01 base (2).
  7. Place face sealing encapsulated O-ring (10) in the O-ring groove located on the top of the FHU01 bowl (1).
  8. Turn FHU01 bowl (1) into the base (2). Take care to not cross-thread them. Torque with wrench tools (12100-PV-0022) until O-rings are compressed – the top of the base (2) will be a Maximum of 4.8 inches (122mm) from the 5.8-in (147mm) diameter step on the bowl (1). The assembly may tighten before O-rings compress, especially after thermal cycling. PTFE parts may deform when thermal cycled. FHU synchronized threads fix this issue by forcing the parts back into shape during re-assembly. If this is required, the threads may be tight and/or difficult to start, especially over time.
  9. Install a drain line connection in the bottom of the housing bowl if not already installed.
  10. Turn in the screw (5) until bellows (3) seats against the filter. This ensures the filter does not fall out of the cap if thermal cycling causes cap expansion or contraction. Do not overextend bellows. If the pre-installed bellows screw is not compatible with your filter, use the alternate bellows screw provided. Loosen and remove the bellows screw (5) and nut (6). Then, unscrew the bellows cap (4) with the top check plug torque wrench adapter (11). Remove the pre-installed bellows (3) and replace it with the alternate bellows (7). If the bellows do not drop out it may be necessary to unscrew the housing body and press it out from the inside.
  11. After seating the screw (5), twist the screw nut (6) upward, and finger tighten against the bowl (1). This will prevent the screw from vibrating loose.
  12. When changing filters in the FHU01, the first step should always be to loosen the screw nut and screw. Removal of the screw will not cause a leak because the bellows act as a seal. Filter lengths can vary, therefore take care to accommodate filter size by the outward adjustment of the bellows screw. This ensures that upon reinstallation of the bowl into the base after a filter change, that the O-rings are compressed before the bellows contact the filter. After installing and tightening the bowl into the base, the screw must then be twisted inward until the bellows contact the filter (length variation between filters is accommodated by flex in the bellows). The screw nut must then be twisted and tightened against the bowl to prevent the screw from vibrating loose.WHITE-KNIGHT-FHU01-Filter-Housings-FIG- \(7\)

Prevent Cross Threading
Markings were added to the head and body in 2021 to help users ensure their connection is threaded properly.

  • A. Threads on the base and body start at markings. Align the two markings before tightening to avoid cross-threading.
  • B. When tightened correctly, this gap will be closed.
  • C. Tighten the base until it reaches this line.
  • D. When the base is tightened to the body line and the gap is fully closed, the housing is tightened correctly. Do not over-tighten.WHITE-KNIGHT-FHU01-Filter-Housings-FIG- \(8\)

Ordering Instructions

WHITE-KNIGHT-FHU01-Filter-Housings-FIG-18

All options are required.

Standard options are highlighted

Example Filter Length

Liquid Fittings| 3. Inlet

4. Outlet

---|---
Flaretek Compatible| 1/2 in.| F08
3/4 in.| F12
1 in.| F16
1-1/4 in.| F20
Pillar S-300

****

| 1/2 in.| P08
3/4 in.| P12
1 in.| P16
1-1/4 in.| P20
1-1/2 in.| P24
Primelock

__

| 3/4 in.| L12
1 in.| L16
1-1/4 in.| L20
Tube Adapter

FNPT

__

| 3/4 in.| T12
1 in.| T16
1-1/4 in.| T20
1-1/2 in.| T24
3/4 in.| N12
1 in.| N16
1-1/4 in.| N20
Weldable| 3/4 in.| S08
1 in.| S12
Synchro| 1/2 in.| S08
3/4 in.| S12
1 in.| S16
__

Drain / Vents

| 5. Pre-filter

6. Post-filter

7. Bowl

---|---
Flaretek Compatible| 1/4 in.| F4
3/8 in.| F6
Pillar S-300| 1/8 in.| P2
1/4 in.| P4
3/8 in.| P6
Primelock| 1/4 in.| L4
3/8 in.| L6
FNPT| 1/4 in.| N4
3/8 in.| N6

Revision

No revision: blank

Contact White Knight support for revision level or copy exact code activation details. Configurations are not Copy Exact Part Numbers.

Email : support@wkfluidhandling.com
Phone : 435.783.6040

Warranty
White Knight follows strict manufacturing, assembly, and testing procedures to ensure consistency and reliability. White Knight warrants that FHU01 filter housings and components are free from defects in materials and workmanship for one year from our shipment date or your installation date if provided within 90 days of shipment from our facility. Failures due to normal wear, misuse, abuse, or unauthorized disassembly nullify this warranty.

White Knight does not guarantee the suitability of products for specific applications. White Knight is not liable for any damage or expense resulting from the use or misuse of its products in any application. Responsibility is limited solely to the repair or replacement of defective products or components. Prior written, faxed, or emailed approval must be obtained from White Knight before returning any product or component for warranty consideration. All determinations regarding the cause of failure are made by White Knight, and all decisions regarding warranty fulfillment or nullification are made by White Knight.

THE FOREGOING WARRANTY IS EXCLUSIVE AND INSTEAD OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED, INCLUDING ANY GUARANTEE OF SUITABILITY FOR ANY PURPOSE. NO VARIATIONS OF THIS WARRANTY SHALL BE HONORED NOR CONSIDERED LEGALLY BINDING, EXCEPT WRITTEN AGREEMENTS SIGNED BY THE CEO OF WHITE KNIGHT FLUID HANDLING.

Brian Callahan, President of White Knight Fluid Handling

Service

Follow decontamination instructions when returning a product for service. DO NOT REMOVE THE PAGE FROM THE MANUAL. Copy the page from the manual or download it at https://wkfluidhandling.com/support/rma/.

Decontamination Instructions
PRINT COMPLETED DECONTAMINATION CERTIFICATION. IT MUST BE INCLUDED IN YOUR RMA SHIPMENT.

White Knight products are designed for use with caustic and otherwise dangerous liquids. Handle every product as if it contains dangerous chemicals whether or not it does.

  • Only those with adequate safety training should attempt to handle used products.
  • Wear adequate safety gear appropriate for chemicals that have been in the product.
  • Review relevant Material Safety Data Sheets (MSDS) before handling the product.
  • Review emergency numbers for use in the event of an accident.
  • Prepare Ph papers, showers, antidotes, clean-up equipment, neutralizers, and other safety devices used to detect, neutralize, or minimize the effects of chemicals described in appropriate MSDS documents.

Rinse with DI Water
Circulate DI water through the product for twenty minutes before disassembly and/or double bagging for shipment. If the product is nonfunctional, force DI water from the inlet through an outlet for 40 minutes before shipment preparations.

Remove Product from Station:

  1. Disconnect liquid tubing connectors from the front of the product (opposite shuttle valve).
  2. Plug NPT fittings with PTFE plug, Flare fittings with flare nose cover and cap,  or other plug or cap as recommended by the connector supplier.
  3. Disconnect the air supply tubing from the face of the shuttle valve.
  4. Loosen the mount screw from a base plate. (Note: do not remove the screw from the base plate).
  5. Remove the ase plate using the proper tool for the fastening devices (e.g. Allen wrench or screwdriver).
    • Note : Base plate may stay if needed for replacement product to be used.
  6. Return all removed parts to the product.

Return Product to White Knight:

  1. Rinse the product with DI water as described above after removing it from its station.
  2. Drain the remaining DI water from the product inlet and outlet liquid tubing connectors.
  3. Plug liquid outlets as described in the Remove Product from Station section above.
  4. Dry the product, double bag it, and seal it in thick polyethylene bags.
  5. Return the product to its original packaging.
  6. Include MSDS for the chemical that the product was handled in the box with the product.
  7. Obtain the MA number from White Knight and write it on the outside of the box.
  8. Ship to White Knight following all rules, regulations, and laws regarding the shipment of dangerous materials. Ship freight pre-paid. No collect shipments will be accepted. Unauthorized use of White Knight shipping accounts will result in the addition of freight to the bill in addition to a service charge.

Include All Components:
Products returned to White Knight for evaluation, service or repair must be complete with all components, including but not limited to base plate, mount screws, tubing connectors, tubing connector caps, flare noses, shuttle valves, mufflers, and tubing. Missing parts will be added to the product and charged to the customer.

DO NOT REMOVE THE PAGE FROM THE MANUAL.

Copy the page from the manual or download it at https://wkfluidhandling.com/support/rma/.

Decontamination Certification
COMPLETE AND PRINT THIS FORM. IT MUST BE INCLUDED IN YOUR RMA SHIPMENT. I, the undersigned employee, certify that all decontamination and safety procedures described in the Decontamination Instructions section have been followed for the return of the product below.

  • RMA#:
    (We cannot process returns without an RMA number.)

  • Serial#:
    (We cannot process returns without a product serial number.)

Metal Exposure:
(Check all that apply. Write in other metals if necessary.)WHITE-KNIGHT-
FHU01-Filter-Housings-FIG- \(10\)

Chemical Exposure:
(Check all that apply. Write in other chemicals if necessary.)WHITE-KNIGHT-
FHU01-Filter-Housings-FIG- \(11\)

Shipping Information:
Please indicate metal processes to which the product has been exposed by clearly and conspicuously labeling the outside of the return package with the metal.

Products exposed to Metal Processes must be sent to the following address: White Knight Fluid Handling 187 East 670 South, Suite B Kamas, UT 84036

  • Print Name:
  • Signature:

Products NOT exposed to Metal Processes must be sent to the following address: White Knight Fluid Handling 187 East 670 South, Suite C Kamas, UT 84036

Date:

Copyright © 2023 White Knight Fluid Handling A Graco company P : 435.783.6040 support@wkfluidhandling.com https://wkfluidhandling.com

Ver. 1.0.5 15 Mar 2023 P. 9 Subject to change without notice

White Knight Support
187 E. 670 S. Kamas, UT 84036

Part No. 18200-LM-0089

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>