BOGEN RIO1S Relay / Input / Output Transformer-Balanced Module Instruction Manual
- June 6, 2024
- BOGEN
Table of Contents
RIO1S
Relay / Input / Output
Transformer-Balanced Module
Features
- Transformer-isolated, balanced line-level input
- 600-ohm or 10k-ohm jumper-selectable input impedance
- Transformer-isolated, balanced line-level output
- 8-ohm, 750mW output
- Input and output level controls
- Relay responds to selectable priority level
- External control of priority muting
- N.O. or N.C. relay contacts
- Input can be muted from higher priority modules, with signal fade back
- Output can activate with a relay priority level
- Screw terminal strips
- RJ11 connection with line output and dedicated N.O. relay contact
Module Installation
- Turn off all power to the unit.
- Make all necessary jumper selections.
- Position module in front of any desired module bay opening, making sure that the module is right-side up.
- Slide module onto card guide rails. Make sure that both the top and bottom guides are engaged.
- Push the module into the bay until the faceplate contacts the unit’s chassis.
- Use the two screws included securing the module to the unit.
WARNING: Turn off power to the unit and make all jumper selections before installing the module in the unit.
Note: This module may include a break-away tab as pictured below. If
present, remove this tab to install a module in input module bays.
Controls and Connectors
Jumper Selections
Impedance Selector
This module can be set for two different input impedances. When connecting to
a 600-ohm source, it is desirable to have a 600-ohm matching input impedance.
For typical source equipment, use a 10kohm setting.
Input Muting
This module’s input can remain continuously active or be muted by other
modules. When muting is enabled, the input is permanently set to the lowest
priority level. When disabled, the input will not respond to any priority
signal and will remain active continuously.
Input Bus Assignment
This module can be set to operate so that the input signal can be sent to the
main unit’s A bus, B bus, or both buses. Bus selection pertains to M-Class use
only. Power Vector has only one bus. Set jumpers to Both for Power Vector use.
External Mute Priority Level
Determines what priority level the system will see when looking at the
external control. Selecting Level 1 will result in the external device
becoming the highest priority mute and silencing all lower priority modules.
Likewise for all other lower settings except for priority Level 4, which is
not applicable since modules with this level can only respond to mute signals.
Priority Level 4 modules cannot send mute signals.
Jumper Selections, cont.
Relay Priority Level
The relay setting determines what priority level and above will cause the
relay to energize. Since this module’s relay must receive a mute signal from a
higher priority module to change states, it is only possible to use the three
lower priority levels (2, 3, 4). Priority Level 1 (highest) is not applicable.
Output Gating
The output signal can be available continuously or available only when the
relay priority level setting has been met or exceeded. When set to ACTIVE, it
provides continuous signal output. When set to GATE, it provides output based
on priority level.
Relay Contacts
This module’s screw terminal relay contacts can be set for normally open
(N.O.) or normally closed (N.C.) operation.
Output Bus Assignment
The output signal can be taken from the module’s A bus, B bus, or the unit’s
MIX bus. On some Bogen amplifier products, the A and B buses may be tied
together.
Input Wiring
Balanced Connection
Use this wiring when the external equipment supplies a balanced, 3-wire
signal. Connect the shield wire of the external signal to the ground terminal
of the external equipment and to the ground terminal of the RIO1S. If the “+”
signal lead can be identified, connect it to the plus “+” terminal of the
RIO1S. If the external equipment polarity cannot be identified, connect either
of the hot leads to the plus “+” terminal. Connect the remaining lead to the
minus “-” terminal of the RIO1S.
Note: If the polarity of the output signal versus the input signal is important, it may be necessary to reverse input lead connections.
Unbalanced Connection
When the external device provides only an unbalanced connection (signal and
ground), the RIO1S module should be wired with the “-” terminal shorted to the
ground. The unbalanced signal’s shield wire is connected to the input module’s
ground and the signal hot wire is connected to the “+” terminal. Since
unbalanced connections do not provide the same amount of noise immunity that a
balanced connection does, the connection distances should be made as short as
possible.
Output Wiring
Balanced Connection
Use this wiring when the external equipment requires a balanced, 3-wire
signal. Connect the shield wire to the ground terminal of the external
equipment and to the ground terminal of the RIO1S. If the “+” signal lead from
the external equipment can be identified, connect it to the plus “+” terminal
of the RIO1S. If the external equipment polarity cannot be identified, connect
either of the hot leads to the plus “+” terminal. Connect the remaining lead
to the minus “-” terminal of the RIO1S.
Note: If the polarity of the output signal versus the input signal is important, it may be necessary to reverse input lead connections.
Unbalanced Connection
When the external device provides only an unbalanced connection (signal and
ground), the RIO1S module should be wired with the “-” terminal shorted to the
ground. The unbalanced signal’s shield wire is connected to the input module’s
ground and the signal hot wire is connected to the “+” terminal. Since
unbalanced connections do not provide the same amount of noise immunity that a
balanced connection does, the connection distances should be made as short as
possible.
Speaker Output Wiring
8Ω Output
The RIO1S output is capable of driving an 8 speaker load. Available power is
up to 750mW. When connecting a speaker, be sure to connect the module’s “+”
and “-” to the speakers “+” and “-“, respectively.
Block Diagram
COMMUNICATIONS, INC.
www.bogen.com
© 2007 Bogen Communications, Inc.
54-2097-01F 0706
Specifications are subject to change without notice.