**MEAN WELL RSP-200 series 200 Watt Single Output with PFC Function Instruction Manual

**

Features

  • Universal AC input/ Full range
  • Built-in active PFC function
  • High efficiency up to 90%
  • Cooling by free air convection
  • Protections: Short circuit / Overload/Over voltage / Over temperature
  • Optional conformal coating
  • LED indicator for power on
  • 3 years warranty

Description

RSP-200 is a 200W single output enclosed type AC/DC power supply. This series operates for 88~264VAC input voltage and offers the models with the DC output mostly demanded from the industry. Each model is cooled by free air convection, working for the temperature up to 70°C.

Model Encoding / Order Information

Applications

  • Factory control or automation apparatus
  • Test and measurement instrument
  • Laser related machine
  • Burn-in facility
  • RF application

GTIN CODE

MW Search: https://www.meanwell.com/serviceGTIN.aspx

SPECIFICATION

MODEL| RSP-200-2.5| RSP-200-3.3| RSP-200-4| RSP-200-5| RSP-200-7.5| RSP-200-12
---|---|---|---|---|---|---
OUTPUT| DC VOLTAGE| 2.5V| 3.3V| 4V| 5V| 7.5V| 12V
RATED CURRENT| 40A| 40A| 40A| 40A| 26.7A| 16.7A
CURRENT RANGE| 0 ~ 40A| 0 ~ 40A| 0 ~ 40A| 0 ~ 40A| 0 ~ 26.7A| 0 ~ 16.7A
RATED POWER| 100W| 132W| 160W| 200W| 200.25W| 200.4W
RIPPLE & NOISE (max.) Note.2| 100mVp-p| 100mVp-p| 100mVp-p| 150mVp-p| 150mVp-p| 150mVp-p
VOLTAGE ADJ. RANGE| 2.35 ~ 2.85V| 2.97 ~ 3.8V| 3.7 ~ 4.3V| 4.5 ~ 5.5V| 6 ~ 9V| 10 ~ 13.2V
VOLTAGE TOLERANCE Note.3| ±2.0%| ±2.0%| ±2.0%| ±2.0%| ±2.0%| ±1.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.3%
LOAD REGULATION| ±1.5%| ±1.5%| ±1.0%| ±1.0%| ±1.0%| ±0.5%
SETUP, RISE TIME| 1500ms, 50ms/230VAC        3000ms, 50ms/115VAC at full load
HOLD UP TIME (Typ.)| 8ms at full load  230VAC /115VAC
INPUT| VOLTAGE RANGE    Note.4| 88 ~ 264VAC       124 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)| PF>0.95/230VAC        PF>0.98/115VAC at full load
EFFICIENCY (Typ.)| 79.5%| 81.5%| 84%| 85.5%| 89%| 89%
AC CURRENT (Typ.)| 2A/115VAC       1.1A/230VAC| 2.5A/115VAC        1.3A/230VAC
INRUSH CURRENT (Typ.)| 20A/115VAC       40A/230VAC
LEAKAGE CURRENT| <1mA / 240VAC
PROTECTION| OVERLOAD| 105 ~ 135% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE| 2.88 ~ 3.5V| 3.8 ~ 4.62V| 4.5 ~ 5.6V| 5.75 ~ 7V| 9.4 ~ 10.9V| 13.8 ~ 16.2V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down o/p voltage, recovers automatically after temperature goes down
ENVIRONMENT| WORKING TEMP.| -30 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 45℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC(Note 5)| SAFETY STANDARDS| UL62368-1,TUV BS EN/EN62368-1, EAC TP TC 004, CCC GB4943.1,BSMI CNS14336-1, AS/NZS 60950.1 approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC  I/P-FG:2KVAC  O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020, CNS13438, GB9254 Class B, GB17625.1
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level, EAC TP TC 020
OTHERS| MTBF| 2078.1K hrs min.    Telcordia SR-332 (Bellcore) ; 224.5K hrs min.  MIL-HDBK-217F (25℃)
DIMENSION| 21511530mm (LWH)
PACKING| 0.72Kg; 15pcs/11.8Kg/0.67CUFT
NOTE|

  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
  3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. Derating may be needed under low input voltages. Please check the derating curve for more details.
  5. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMl testing of component power supplies.(as available on http://www.meanwell.com)
  6. For charging related applications, please consult Mean Well for details.
  7. Strongly recommended that external output capacitance should not exceed 5000uF. (Only for: RSP-200-2.5/-3.3/-4/-5/-7.5/-12/-13.5/-15)
  8. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
    ※ Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

MODEL| RSP-200-13.5| RSP-200-15| RSP-200-24| RSP-200-27| RSP-200-36| RSP-200-48
---|---|---|---|---|---|---
OUTPUT| DC VOLTAGE| 13.5V| 15V| 24V| 27V| 36V| 48V
RATED CURRENT| 14.9A| 13.4A| 8.4A| 7.5A| 5.56A| 4.2A
CURRENT RANGE| 0 ~ 14.9A| 0 ~ 13.4A| 0 ~ 8.4A| 0 ~ 7.5A| 0 ~ 5.56A| 0 ~ 4.2A
RATED POWER| 201.15W| 201W| 201.6W| 202.5W| 200.16W| 201.6W
RIPPLE & NOISE (max.) Note.2| 150mVp-p| 150mVp-p| 150mVp-p| 200mVp-p| 220mVp-p| 240mVp-p
VOLTAGE ADJ. RANGE| 12 ~ 15V| 13.5 ~ 18V| 20 ~ 26.4V| 26 ~ 31.5V| 32.4 ~ 39.6V| 41 ~ 56V
VOLTAGE TOLERANCE Note.3| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION| ±0.3%| ±0.3%| ±0.2%| ±0.2%| ±0.2%| ±0.2%
LOAD REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME| 1500ms, 50ms/230VAC        3000ms, 50ms/115VAC at full load
HOLD UP TIME (Typ.)| 8ms at full load  230VAC /115VAC
INPUT| VOLTAGE RANGE          Note.4| 88 ~ 264VAC       124 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)| PF>0.95/230VAC        PF>0.98/115VAC at full load
EFFICIENCY (Typ.)| 89%| 89.5%| 89.5%| 89%| 90%| 90%
AC CURRENT (Typ.)| 2.5A/115VAC        1.3A/230VAC
INRUSH CURRENT (Typ.)| 20A/115VAC       40A/230VAC
LEAKAGE CURRENT| <1mA / 240VAC
PROTECTION| OVERLOAD| 105 ~ 135% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE| 15.7 ~ 18.4V| 18.8 ~ 21.8V| 27.6 ~ 32.4V| 32.9 ~ 38.3V| 41.4 ~ 48.6V| 58.4 ~ 68V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down o/p voltage, recovers automatically after temperature goes down
ENVIRONMENT| WORKING TEMP.| -30 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 45℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC(Note 5)| SAFETY STANDARDS| UL62368-1,TUV BS EN/EN62368-1, EAC TP TC 004, CCC GB4943.1,BSMI CNS14336-1, AS/NZS 60950.1 approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC  I/P-FG:2KVAC  O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3,EAC TP TC 020, CNS13438, GB9254 Class B, GB17625.1
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level, EAC TP TC 020
OTHERS| MTBF| 2078.1K hrs min.    Telcordia SR-332 (Bellcore) ; 224.5K hrs min.  MIL-HDBK-217F (25℃)
DIMENSION| 21511530mm (LWH)
PACKING| 0.72Kg; 15pcs/11.8Kg/0.67CUFT
NOTE|

  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
  3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. Derating may be needed under low input voltages. Please check the derating curve for more details.
  5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMl testing of component power supplies. (as available on http://www.meanwell.com)
  6. For charging related applications, please consult Mean Well for details.
  7. Strongly recommended that external output capacitance should not exceed 5000uF. (Only for: RSP-200-2.5/-3.3/-4/-5/-7.5/-12/-13.5/-15)
  8. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
    ※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Mechanical Specification

Terminal Pin No. Assignment :

Pin No. Assignment Pin No. Assignment
1 AC/L 4~6 DC OUTPUT -V
2 AC/N 7~9 DC OUTPUT +V
3 FG

Block Diagram

PFC fosc : 100KHz
PWM fosc : 100KHz

Derating Curve

Static Characteristics

User’s Manual

Documents / Resources

| MEAN WELL RSP-200 series 200 Watt Single Output with PFC Function [pdf] Instruction Manual
RSP-200 series 200 Watt Single Output with PFC Function, RSP-200 series, 200 Watt Single Output with PFC Function, Single Output with PFC Function, Output with PFC Function, with PFC Function, PFC Function
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals

Related Manuals