UBIQUITI UNAS Pro UniFi NAS Professional Owner’s Manual
- June 16, 2024
- UBIQUITI
Table of Contents
UBIQUITI UNAS Pro UniFi NAS Professional
Product Information
Specifications
- Dimensions: 442 x 325 x 87 mm (17.4 x 12.8 x 3.4 inches)
- Weight: Without rackmount brackets: 9.2 kg (20.28 lb), With rackmount brackets: 9.45 kg (20.83 lb)
- Enclosure material: SGCC steel
- Mount material: SGCC steel
- Processor: [Processor information]
- System memory: [System memory information]
- On-board flash storage: [Flash storage capacity]
- Max. power consumption: [Max power consumption]
- Max. power budget for drives: [Power budget for drives]
- Power method: [Power method]
- Power supply: [Power supply information]
- Networking interface: [Networking interface]
- RF interface: [RF interface]
- LCM display: [LCM display information]
- Management interface: [Management interface information]
- ESD/EMP protection: [ESD/EMP protection information]
- Operating temperature: [Operating temperature range]
- Operating humidity: [Operating humidity range]
- Certifications: [Certifications]
Product Usage Instructions
Mounting the UNAS-Pro
To mount the UNAS-Pro, follow these steps:
- Ensure that you have the necessary rackmount brackets.
- Position the UNAS-Pro in the desired location within the rack.
- Attach the rackmount brackets to the UNAS-Pro using the provided screws.
- Securely mount the UNAS-Pro to the rack using the appropriate mounting hardware.
Connecting the Power
To connect the power to the UNAS-Pro, follow these steps:
- Locate the power supply input on the rear panel of the UNAS-Pro.
- Insert the power supply connector into the power input and ensure it is securely connected.
- Connect the other end of the power supply to a power outlet.
Connecting to the Network
To connect the UNAS-Pro to your network, follow these steps:
- Locate the networking interface ports on the rear panel of the UNAS-Pro.
- Using Ethernet cables, connect one end of each cable to the networking interface ports on the UNAS-Pro.
- Connect the other end of each cable to your network switch or router.
Using the UNAS-Pro
To use the UNAS-Pro, follow these instructions:
- Ensure that the UNAS-Pro is powered on and connected to your network.
- Access the management interface of the UNAS-Pro through a web browser on a connected device.
- Follow the on-screen instructions and configure the necessary settings for your desired usage.
- You can now begin using the UNAS-Pro for storage and other relevant tasks.
FAQ
-
Q: What is the maximum weight capacity for the UNAS-Pro?
A: The maximum weight capacity for the UNAS-Pro is 9.45 kg (20.83 lb) with rackmount brackets. -
Q: What certifications does the UNAS-Pro have?
A: The UNAS-Pro has [list of certifications]. -
Q: How do I access the management interface of the UNAS-Pro?
A: To access the management interface of the UNAS-Pro, you need to open a web browser on a connected device and enter the appropriate IP address or domain name provided in the user manual. -
Q: Can I increase the on-board flash storage of the UNAS-Pro?
A: No, the on-board flash storage of the UNAS-Pro cannot be increased. However, you can connect external drives for additional storage capacity.
Mechanical
- Dimensions
- 442 x 325 x 87 mm (17.4 x 12.8 x 3.4″)
- Weight
- Without rackmount brackets : 9.2 kg (20.28 lb)
- With rackmount brackets : 9.45 kg (20.83 lb)
- Enclosure material
- SGCC steel
- Mount material
- SGCC steel
Hardware
- Processor
- Quad-Core ARM® Cortex ® -A57 at 1.7 GHz
- System memory
- 4 GB DDR4
- On-board ash storage
- 32 GB eMMC
- Max. power consumption
- 160W
- Max. power budget for drives
- 135W
- Power method (1) Universal AC input, 100—240V AC, 3A Max, 50/60 Hz
- (1) USP-Battery DC input, 11.5V DC, 13.91A
- Power supply
- AC/DC, internal, 200W
- Networking interface
- (1) 10/100/1000 MbE RJ45 port
- (1) 1/10 GbE SFP+ port
- RF interface
- (1) Bluetooth v4.1
- LCM display
- (1) 1.3″ touchscreen
- Bootup animation: bootup in progress
- Firmware upgrade icon: rmware upgrading
- Steady white: factory defaults, awaiting adoption
- Steady blue: device is adopted
- Management interface
- Ethernet-band
- ESD/EMP protection
- Air: ± 12kV,
- Contact: ± 8kV
- Operating temperature
- -5 to 40° C (23 to 104° F)
- Operating humidity
- 5 to 95% noncondensing
- Certifications
- FCC, CE, IC
LEDs
- Ethernet
- Green: 1 Gbps
- Amber: 10/100 Mbps
- SFP+
- White: 10 Gbps
- Green: 1 Gbps
- HDD
- Amber: disk error
- White: disk detected
- Battery
- Blue: ready
Specifications are subject to change. Ubiquit products are sold with a limited warranty described at www.ui.com/supportwarranty ©2022 Ubiquiti Inc. All rights reserved. Ubiquiti, Ubiquiti Networks, the Ubiquiti U logo, UniFi, and UniFi Protect are trademarks or registered trademarks of Ubiquiti Inc. in the United States and in other countries. All other trademarks are the property of their respective owners.
FCC
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions.
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
The following apply to Class A products
This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radio communications.
- Operations of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.”
ISED Canada
CAN ICES-3(A)/NMB-3(A)
This device complies with ISED Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions:
- This device may not cause interference, and
- This device must accept any interference, including interference that may cause undesired operation of the device.
RF Exposure Warning
The antennas used for this transmitter must be installed to provide a separation distance of at least 20(FCC/IC) cm from all persons and must not be located or operating in con junction with any other antenna or transmitter.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>