SALTO ZH 160 Wireless Hardware Gateway Installation Guide

June 16, 2024
SALTO

**SALTO ZH 160 Wireless Hardware Gateway Installation Guide


**

Description

The Gateway is the link between the PC and SALTO’s wireless network SALTO RFnet or SALTO BLUEnet (wireless escutcheons). It gives real-time information to the PC. Gateways are completely managed through the SALTO Software, it collects all the information sent by escutcheons that belong to the Gateway. It has been designed with PoE technology, capable of power the SALTO Gateway through Ethernet infrastructure.

Electrical characteristics

Operation conditions

| Min| Typ| Max| Unit
---|---|---|---|---
Temperature| 0| 25| 60| ºC
Humidity| 35| | 85| %

Cable requirements

Ethernet UTP CAT5e

Node Connection (AB) Generic twisted pair wire Note1
Node Connection (Vdd)24 AWG

Complies with IEC 60332, IEC 60695-11-21 or VW-1 (UL 2556)

SALTO RFnet Characteristics(if internal node installed)

Frequency Range 2400-2483 Mhz
RF Standard IEEE 802.15.4
Indoor Radio Range 10/15m*
Max output power 5dBm

(*) Depending upon installed environment.

UL Statement
Comply with UL/CSA 62368-1:
Product could be connected to PoE networks without routing to the outside plant

Mechanical installation

Electrical installation

  • When PoE and auxiliary power supplies are connected at the same time, Poe is disconnected.
  • Pressing CLR button 5 seconds, Gateway enters in addressing mode.

Auxiliary power supply needed when Ethernet infrastructure is not PoE (Power over Ethernet).

RS485 bus termination resistor is needed (ON position) when the node is located at the end of the bus, or there are not external nodes connected.

Configuration

Addressing and configuration
Gateway is a DCHP ready device. If there is no DCHP server on the local Ethernet network, user can manually configure a fixed IP address changing different parameter using SALTO Gateway Web Server:

  1. Pressing CLR button for 5 seconds, SALTO Gateway enters in addressing mode (green LED turns to orange).
  2. Access to 192.168.0.234 IP address with a standard browser and configure network parameters as needed.
  3. Pressing again CLR button for 5 seconds or confirming the configuration, the device is going to quit the addressing mode.

When addressing process success, configure the wireless network with SALTO’s software (check the help of the application).

Installation example

(*) Depending upon installed environment.

Signalling

LED COLOR DESCRIPTION
No light Lack of power supply
Green Everything is OK
Orange Gateway in “Addressing mode”
Red Gateway in “Bootloader mode” state
Flashing Green No initialized by SALTO’s software

The LEDs on the Ethernet Connector show the state of the Ethernet communication.

LED COLOR DESCRIPTION
No light No Ethernet Connection
Green Ethernet active
Flashing Orange Data transfer taking place through Ethernet

Operational test

Once the product is installed, follow these steps to check the correct operation:

  • Visually chek that the LED is active after power on.
  • When nodes and locks are installed, check that the LED is green.
  • Check Ethernet connector LED to know communication state.

This unit should be tested at least once a year as described in “Operational Test”.

European view
All contents current at time of publication.
SALTO Systems S.L. reserves the right to change availability of any item in this catalog, its design, construction, and/or materials.

© 2023 SALTO Systems S.L.

221135-ED.2 – 16/10/2023

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

SALTO User Manuals

Related Manuals