Trudian TD-X6-B Smart Lock User Guide

June 16, 2024
Trudian

Trudian TD-X6-B Smart Lock

Product Information

Specifications

  • Compliance: FCC Part 15
  • Radiation exposure limits: FCC approved for uncontrolled environment
  • Minimum distance between radiator and body: 20cm

Product Usage Instructions

Safety Precautions
Before using the product, please read and understand the following safety precautions:

  1. Do not make any changes or modifications to the product that are not expressly approved by the manufacturer. Doing so can void your authority to operate the equipment.
  2. Ensure that the product is operated in a way that does not cause harmful interference to other devices.
  3. Maintain a minimum distance of 20cm between the radiator of the product and your body during installation and operation.

Installation
To install the product, follow these steps

  1. Select a suitable location for installation.
  2. Ensure that there is at least a 20cm distance between the radiator of the product and your body.
  3. Connect the necessary cables and power supply to the product.
  4. Verify that all connections are secure.

Operation
To operate the product, follow these steps

  1. Ensure that the product is connected to a power source.
  2. Turn on the product using the power button or switch.
  3. Follow the specific instructions for using the product’s features or functions.
  4. If experiencing any interference or undesired operation, try adjusting the location or distance between the product and other devices.

FAQ

Q: What should I do if I experience interference from the product?
A: If you experience interference or undesired operation, try adjusting the location or distance between the product and other devices. Ensure that there is a minimum distance of 20cm between the radiator of the product and your body during installation and operation.

Q: Can I modify the product?
A: No, any changes or modifications not expressly approved by the manufacturer can void your authority to operate the equipment.

Installation guide of double latches mortise

Accessory

Trudian-TD-X6-B-Smart-Lock- \(1\)

Door opening direction

  1. Right handle opening
  2. Left handle opening Trudian-TD-X6-B-Smart-Lock- \(2\)

Shift the left and right
According to your needs to adjust the left and right by a screw driver to release screw, then turn the handle 180 degree, then fix the screw.
Note : Do not unscrew the screw in the handle hole, if there is broken when you do that, you will not have any warranty.

Trudian-TD-X6-B-Smart-Lock- \(3\) Trudian-TD-X6-B
-Smart-Lock- \(4\)Adjust the mortise direction
According to the your need to adjust the mortise direction. Latch shifting plat

Trudian-TD-X6-B-Smart-Lock- \(5\)

Accessories for sorts of door thickness
Available door thickness 35mm-55mm. If the door is over this range, please contact us for more information. Please select the correct accessories according to your door thickness.

Trudian-TD-X6-B-Smart-Lock- \(6\)

Caution before installation

  1. Do not be a strong force
  2. Use correct installation
  3. Wear glass to protect when installation, avoid tools. your eyes when drilling to damaging the lock. holes.
  4. Drilling the door holes on both side of the door avoiding to damaging the door plate.

Trudian-TD-X6-B-Smart-Lock- \(7\)

Installation

Installation steps

  1. As Figure 1:
  2. Divide the Back Lock into Battery cover and Back panel.
  3. As Figure 2:
  4. Make the mortise cable get through the door plate, fix the mortise with 2 screws.
  5. As Figure 3:
  6. Fix the two connecting pillars on the front panel
  7. Trudian-TD-X6-B-Smart-Lock- \(8\)As Figure 4:
  8. Put the spindle on the mortise.
  9. Make the front panel cable across to the door plate and connect to the back panel.
  10. fix the front panel and back panel with two screws.
  11. As Figure 5:
  12. Put the Batteries correctly and fix the Battery cover. Trudian-TD-X6-B-Smart-Lock- \(9\)
  13. As Figure 6:
  14. Install the strike box and strike plate on the door frame with 2 screws. (Note: this no strike box for steel door frame)
  15. Test the lock if it works correctly.

Check points after installation

  1. The face plate is horizontal with the door.
  2. The Latch bolt, Dead bolt and Security Bolt must works smoothly and flexibly.
  3. The Front lock is vertical and stable.

Operation

Intelligent lock(five in one) operation manual

  1. Function and Operation

  2. Description of terms and functional keys

  3. Adminstrator information: refer to the Administrator’s fingerprint, password or IC card.
    Unlock information: refer to the input fingerprint, password ,Remote control or IC card information (including Administrator and ordinary users).

  4. Key”*”: clear key/back key. Enter the password or point by clearing the previous input.Press the clear key three times in succession, empty all input.

  5. Key”#”: confirmation key or menu function key.

  6. Original state

  7. The factory administrator orinitial password is 123456, under the orinitial state any fingerprint, IC card or password can open the lock.

  8. Any fingerprint, IC card ,or password which are not registered can’t open the lock after inputting the administrator information.

  9. Lock function management (step one)Trudian-TD-X6-B-Smart-Lock- \(11\)

  10. Adm inistrator settings

  11. Add administrator (step 2) Trudian-TD-X6-B-Smart-Lock- \(12\)

  12. Delete administrator information Trudian-TD-X6-B-Smart-Lock- \(13\)

  13. Common user setting

  14. Add administrator informationTrudian-TD-X6-B-Smart-Lock- \(14\)

  15. Delete user information Trudian-TD-X6-B-Smart-Lock- \(15\)

  16. system setting

  17. Voice setting Trudian-TD-X6-B-Smart-Lock- \(16\)

  18. Unlock mode setting Trudian-TD-X6-B-Smart-Lock- \(17\)

  19. Language settings Trudian-TD-X6-B-Smart-Lock- \(18\)

  20. Time setting Trudian-TD-X6-

  21. Restore factory settings Trudian-TD-X6-B-Smart-Lock- \(20\)

Other notes

  1. Input the wrong password more than 5 times in arow, the keyboard locked for 30 seconds, it does not respond to any operations in 30 seconds.
  2. Password peeping prevention function: input password as follows when opening the door with password: XXX password XXX; you can add some extraneous codes before and after the password, and then press # to confirm. The password must be included in the input contents.
  3. If there is no operation more than 10 seconds, system will automatically exit.
  4. After the voltage is lower than 4.6v, the lock will automatically alarm every time when it is opened. After the alarm, the lock can be opened for about 200 times.
  5. Remove the battery cover,press the “Set” key for 6 seconds, the lock was restored to factory mode;
  6. In factory mode,input “333666999#” cna change the language quickly;
  7. When unlocking input “5#”to enter passage mode(One time effective):
  8. When unlocking,input “*”to broadcast the user number;
  9. When Electronic dead lock was opened, Only the administrator can open the lock

Technical Parameters

Trudian-TD-X6-B-Smart-Lock- \(21\)

FCC

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.

Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Note : This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TVtechnician for help.

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator &your body.

www.trudian.com/en/

HQ Add: Farbell Technology Park, Yixian Road, Nanlang, Cuiheng New District, Zhongshan City, Guangdong Province, China. Zip Code:528451 Phone: +86 0760 – 23689666
E-mail: [email protected] If the problem is not solved properly, please send the mail to: [email protected]

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Trudian User Manuals

Related Manuals