SCANGRIP NOVA-EX Extremely Powerful Rechargeable Floodlight Instruction Manual
- June 16, 2024
- SCANGRIP
Table of Contents
- NOVA-EX Extremely Powerful Rechargeable Floodlight
- STANDARD
- Product Model Definition and Basic Parameters
- Usage and Application Scope
- STRUCTURE
- INSTRUCTION
- MAINTENANCE
- Special condition for safe use:
- External Dimension and Installation Diagram (Figures)
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Instruction Manual **NOVA-EX Extremely Powerful Rechargeable Floodlight
3 year warranty***
NOVA-EX Extremely Powerful Rechargeable Floodlight
PATENT PROTECTED
* go to scangrip.com to register II 2G Ex db eb mb
IIC T6 Gb
II 2D Ex tb IIIC T85°C Db IP65
Certificate No.: TüV IT 16 ATEX 082 X
Certificate No.: IECEx TPS 17.0002X
AC Work Light
Important Reminders
-
Please read this instruction before any use, maintenance and service of explosion-proof lights.
-
The explosion-proof light must be used by a certain professional training person.
-
Must use the replacement parts which produced or appointed by the manufacturer for maintenance.
Make sure the maintenance and service are not in a dangerous place and fulfilled by professional trained person. Using the parts which not manufactured by Scangrip A/S. will destroy the explosion-proof performance of the explosion-proof lights. -
The explosion-proof lights should comply with the relevant laws and regulations of the European Union.
WARNING!
- Only open in non-dangerous location!
WARNING!
Battery Pack:
- Only use the power pack from Scangrip A/S. Part No.31300100.
Model No.: ZH-35W-35C1000
Input Voltage: AC100~240V/50-60Hz, Input Current: 0.4A, Output
Voltage:DC26V~33V, Output Current: 1.0A
STANDARD
IEC 60079-0:2017 Explosive atmospheres 一 Par0:Equipment 一 General requirements
IEC 60079-1:2014 Explosive atmospheres 一 Par1:Equipment protection by
flameproof enclosures ”d”
IEC 60079-7:2015 Explosive atmospheres 一 Par7:Equipment protection by
increased safety ”e”
IEC 60079-18:2014 Explosive atmospheres 一 Par18:Equipment protection by type
of protection ”m”
IEC 60079-11:2012 Explosive atmospheres 一 Par11:Equipment protection by
intrinsic safety ”i”
IEC 60079-28:2014 Explosive atmospheres 一 Par28:protection of equipment and
transmission systems using optical radiation
IEC60079-31:2013 Explosive atmospheres 一 Par31: Equipment dust ignition
protection by enclosure”t”
IEC 60529:2001 Degrees of protection provided by enclosure(IP code)
Product Model Definition and Basic Parameters
Basic Parameters: Table 1.
Table 1: Light Design Parameters
Product Description: | AC work light |
---|---|
Product Model No.: | NOVA-EX 03.5619 |
Rated Voltage: | AC100~120V/60Hz AC220~240V/50Hz |
Power Rating: | 35W |
Input Current: | 1.0A Max |
Dangerous Zone: | Zone 1、 Zone 2/ Zone 21、 Zone 22 |
Explosion-proof Symbol: | II 2G Ex db eb mb IIC T6 Gb/ II 2D Ex tb IIIC T85°C |
Db IP65
Luminous Flux:| High 3400lm
CRI (Ra):| >90
CCT:| 6000K
IPXX:| IP65
Operation Temperature(°C):| -20°C~+45°C
Storage Temperature(°C):| -20°C~+45°C
Product Dimension:| L270W266H123mm
Product Weight:| 5.3Kg
Usage and Application Scope
NOVA-EX 03.5619 of AC work light (abbre.Explosion-proof light in the following instruction) is suitable for using in explosive area of Zone 1, Zone 2, Zone 21, Zone 22, gas group IIA/IIB/IIC, dust group IIIA/IIIB/IIIC and Temperature Group T1~T6/T85°C. It is suitable for using in temporary local auxiliary lighting and local main lighting for the industries of petroleum produce, smelting, chemical, pharmaceutical, brewing, military reserve, etc.
STRUCTURE
- Explosion-proof cavity which includes the light source gluing contact surface cannot be repaired if any damage or crack happens.
- The threads of explosion-proof cavity for the switch part cannot be repaired if any damage or crack happens.
- The cylinder part of explosion-proof cavity for the switch part cannot be repaired if any damage or crack happens.
INSTRUCTION
-
Before use, please check whether the packing is in good condition, if there is any visible damage of the light and charger. For the flood light, please check if there is any visible damage of the structure or “abnormal sound” inside. Please open the light to check if the damage will influence the explosion-proof performance and make appropriate treatment.
-
Please check if the explosion-proof light nameplate parameters listed are conformed to the actual conditions of use.
-
The explosion-proof light is with angle adjusting function from 0。-180。 to meet a variety of angle lighting orientation.
-
The explosion-proof light is with three modes Low, High, OFF. Press first “Low”, second “High”, third “OFF”.
-
The power part is cast sealed. Stop use the light when the cast sealing material turn soft, crack and expand.
-
When wiring, make sure there is no absent of the seal ring, the retainer ring and the compression nut in the cable leading device. The cable which goes through the leading device should be grounded. Tighten the compression nut at last.
-
The following operations are prohibited in any possible dangerous area:
Open the light when it is working or turning off the load.
Regular or occasional maintenance and repair. -
The persons who use the light at site should know about the performance of explosion-proof light. Turn off the light in time and evacuate the dangerous area when find any abnormal phenomenon. Unqualified repair person is not allowed to repair the explosion-proof lights.
MAINTENANCE
- The service man must have on-the-job training to know the specification and operating performance of explosion-proof light. They must have professional knowledge and should familiar with the structure of explosion-proof light.
- Clean the dust and dirt on the shell of the explosion-proof light regularly to improve the luminous efficacy and heat dispersion performance. A wet cloth can be used for cleaning.
- Check whether the transparent parts have been impacted by foreign body regularly. Check whether the fasteners and inner components are loose, soldering off or corroded. If yes, do not use it until maintained.
- If use the light in damp environment, please regularly check and change the sealing components to ensure the protective performance of the shell.
- When the cast sealing material turn soft, crack and expand obviously, please change the power immediately.
- The sealing ring, retainer ring and compression nut in the cable leading device cannot be omitted, miss assembling of any part of them, or easily discarded.
- When disassemble the light, must comply with the warning requirements to operate in non-dangerous area.
- After open the shell, should check whether the sealing components become hard or adhesive; whether the insulating layer of the wire become green or carbonized; whether the insulating parts and electrical components become deformed or have scorch. If these problems are found, must repair the light immediately.
- The model, specification, dimension and performance of the parts for maintaining should keep the same as the original ones.
- Before closing the shell, should use replacement type anti rust oil on the explosive-proof threads and check whether the sealing ring is at the original location by achieve the sealing function when close the shell.
- Do not disassemble the sealing parts of the light often. Otherwise the explosive-proof function will be affected.
Special condition for safe use:
- Repairs of the flameproof joints may only be made by the manufacturer or on behalf of the manufacturer and on his own responsibility. Repair in compliance with the values in tables 1 and 2 of IEC 60079-1 is not accepted.
- The external earth connection facility shall be connected reliably.
- Fasteners related with flameproof joints shall have property class at least A2-70.
- The toque for the screws of the terminal box shall be in the range of 22±2kgf.
- When installation, use and maintenance, observe following standards IEC 60079-10, IEC60079-14, IEC60079-17 and IEC 60079-19.
- The connection to the power source shall be located in a safe area. If the connection has to be located in Ex-zones, certified connectors or junction box with enough rating shall be used.
External Dimension and Installation Diagram (Figures)
MANUFACTURER’S WARRANTY – Information for customers in Australia and New
Zealand only This SCANGRIP product is guaranteed for a period of 2 (two) years
from date of purchase. This guarantee shall become invalid if the product has
been misused, tampered with or accidentally damaged.
If the product is defective, we undertake to repair or replace the product or
any part of it that is defective; or wholly or partly recompense you if they
are defective.
This guarantee is in addition to other rights and remedies available to
consumers, all of which are given by us to you if you are a consumer. Our
goods come with guarantees that cannot be excluded under the Australian or New
Zealand Consumer Law. You are entitled to a replacement or refund for a major
failure and for compensation for any other reasonably foreseeable loss or
damage.
You are also entitled to have the goods repaired or replaced if the goods fail
to be of acceptable quality and the failure does not amount to a major
failure.
If you wish to make claim, please return this product to the original place of
purchase together with your purchase receipt or go to our website
www.scangrip.com and fill out the claim form.
SCANGRIP.COMhttp://QRly.me/packaging-manuals/qr/ex-
proof-atex-work-lights-by-scangirp
The file number : 11323412A
V3/04.2022/CXQ
DESIGNED BY
SCANGRIP
IN DENMARK EU DESIGN PATENT NO. 3451038
SCANGRIP A/S Rytterhaven9 5700 Svendborg DENMARK.
Tel:(+45)63 20 63 20
References
Read User Manual Online (PDF format)