Homvana H111 Hybrid Ultrasonic Humidifier User Manual
- June 16, 2024
- Homvana
Table of Contents
Homvana H111 Hybrid Ultrasonic Humidifier
Specifications
- Model: H111
- Input: AC 120V, 60Hz
- Rated Power: 280W
- Water Tank Capacity: 6.5L / 1.72Gal
- Effective Range: 430-861ft2 / 40-80m2
- Max Cool Mist Capacity: 300mL/h
- Max Warm Mist Capacity: 700mL/h
Safety Information
READ AND SAVE THESE SAFETY WARNINGS & INSTRUCTIONS
IMPORTANT: Please read, understand and comply with all of the
instructions in this manual, or it may result in serious injury and/or damage
to the product.
If the humidifier is damaged or if it is not functioning properly,
please contact us : support@homvana.shop
Before Use
- ALWAYS keep the humidifier out of reach from children.
- ONLY use this humidifier as described in this manual.
- DO NOT use this product in wet environments.
- DO NOT place the humidifier near sources of heat, such as stove tops, ovens, or radiators.
- DO NOT place the humidifier near any large pieces of furniture or in any high-traffic area where it can be easily knocked over.
- ALWAYS place the humidifier on a level surface before operation.
- DO NOT overfill the water tank.
- DO NOT plug in the unit with wet hands.
- DO NOT allow water or other liquids into the mist tube or air flue.
While Using
- DO NOT rotate or cover the nozzles while the humidifier is on.
- DO NOT attempt to inhale the mist directly from the nozzles.
- DO NOT shake the humidifier while using.
- DO NOT point the nozzle directly to the smoke alarm, or it may cause a wrong alarm.
Caution: Risk of Leaks and Electric Shock
DO NOT add essential oil, supplemental water treatment liquids, or third-party
water filters into the water tank or base. This will damage the humidifier and
cause leaks. ONLY add essential oil to the aroma pad.
After Use
- ALWAYS unplug the humidifier when not in use, or while cleaning it out.
- DO NOT clean the humidifier right after turning it off, especially after diffusing warm mist. Allow the humidifier to completely cool before cleaning.
- DO NOT immerse the humidifier base, power cord, or plug in water.
- DO NOT use detergents to clean the humidifier; ONLY use distilled white vinegar or citric acid.
- DO NOT place foreign objects into the unit’s base or water tank. DO NOT use other items as replacement parts for this product.
Product Overview
The Hybrid Ultrasonic Humidifier H111 is a high-quality humidifier designed to maintain the humidity level in your room. It combines ultrasonic technology with a warm mist function to provide optimal comfort. The humidifier has various controls and features to customize your experience.
Controls
The Hybrid Ultrasonic Humidifier H111 can be controlled using the buttons on
the device or the included remote controller.
Note: The same controls can be found on the included remote controller.
-
On/Off Button
Tap this button to turn your humidifier on or off. -
Mist Level Button
Tap this button repeatedly to change the cool mist levels. The options include Medium, High, and Low. The default setting is Medium when the humidifier is first turned on. The humidifier will remember the cool mist level you previously set when turned off and left plugged in.
Note:- Medium cool mist is the default setting when the humidifier is first turned on.
- The humidifier will remember the cool and warm mist levels that you previously set when turned off and left plugged in.
-
Heating Button
Tap this button repeatedly to change or turn on/off the warm mist levels. The options include High, Off, Low, and Medium. High warm mist is the default setting when the humidifier is first turned on. After turning on the warm mist, the humidifier may take 8-10 minutes to warm up and make a sound of boiling water. This sound will fade away after a few minutes. Caution: The warm mist produced may be hot. DO NOT place your bare hands, face, or other exposed skin over the nozzles while using the warm mist function.
Note- High warm mist is the default setting when the humidifier is first turned on.
- After turning on the warm mist, the humidifier may take 8-10 minutes to warm up and make a sound of boiling water.This sound fades away after a few minutes.
Caution:
The warm mist produced may be hot. DO NOT place your bare hands, face, or other exposed skin over the nozzles while using the warm mist function.
-
Auto Button
Tap this button to turn on or off Auto Mode. In Auto Mode, the humidifier will produce mist as needed to maintain a comfortable relative humidity (RH) percent of 60% by default. Relative Humidity| Mist Level
---|---
<45% RH| High Cool & Warm Mist
45%-49% RH| Medium Cool & Warm Mist
50%-59% RH| Low Cool & Warm Mist
≥60% RH| Stop misting and enter standby
Note
* Timer, Display Off or Child Lock can be used with Auto Mode.
* Tap the Auto Button, Sleep Button, Mist Level Button, Heating Button or Humidity Button to cancel the Auto Mode.
-
Humidity Button
Tap repeatedly to program the Relative Humidity (RH) percentage among 40% to 80% for the humidifier. To confirm your selection, the humidity display will flash 3 times. To cancel your selection, press the Button for 2 seconds .
Note- The programmed humidity level can be added 5% humidity each time you press the Humidity Button.
- After setting the RH percentage, the display will alternate between the set RH percentage and the current humidity percentage.
- Once the environment RH reaches that preset, the humidifier will automatically stop misting and enter standby mode.
- After the humidifier enters standby mode, the display will alternate between the set RH percentage and the current humidity percent-age. And it will start misting again when the humidity drops to 5% below the preset humidity.
- When the humidifier starts misting again after a while, it may take 8-10 minutes to warm up and make a sound of boiling water.
-
Timer Button
Tap repeatedly to set your desired timer among 1 to 12 hours. Once you stop tapping, the display will flash 3 times and the timer will start. To exit the timer function, tap repeatedly or press for 2 seconds until you hear a beep sound.
Note:- When the timer starts, the display will alternate every 3 seconds between the remaining auto-off time and the current humidity percentage.
- Once selected your desired time, the humidifier will automatically turn off when the timer is finished counting down.
-
Sleep Button
Tap to turn on/off Sleep Mode. When Sleep Mode starts, the LED display will turn off, the humidifier will continue to work as previously set, and no more beep sound for pressing other Buttons. Press and hold for 2 seconds to turn off display. Only equivalent to the screen-off function. The LED display will turn off; the humidifier will work as previously set. -
Child Lock Button
Press and hold for 3 seconds to turn on/off Child Lock. All the Buttons except Child Lock Button (including the On/Off Button) are invalid under Child Lock Mode.
Note: Tap once to enter the Child Lock when using the Remote Controller.
Getting to Use Your Humidifier
Package Contents
- Homvana Hybrid Ultrasonic Humidifier H111 x 1
- Aroma Pad x 3 (1 pre-installed)
- Anti-scale Pad x 5 (1 pre-installed)
- Remote Controller x 1
- Cleaning Brush x 1
- Sponge Filter x 4 (1 pre-installed)
- Quick Start Guide x 1
- User Manual x 1
Set up
Place the humidifier on a level, elevated, and water-resistant surface, such as a table or nightstand. Make sure the room is well-ventilated.
- Place the humidifier on a flat and stable surface.
- Remove the water tank by lifting the tank cover.
- Fill the water tank with clean, cold tap water. Do not exceed the maximum water level indicated on the tank.
- Place the tank cover back on the water tank and ensure it is securely closed.
- Insert the mist nozzle into the mist tube located inside the water tank.
- Attach the sponge filter to the sponge filter holder and insert it into the water valve.
- Connect the power cord to an electrical outlet.
Note:
- Position the humidifier at least 30-cm / 12-in away from walls and appliances to prevent them from getting wet.
- Direct the nozzles away from any furniture to prevent your furniture from getting wet.
Fill or Refill
- Turn off the humidifier and unplug it from the electrical outlet.
- Lift the tank cover and remove the water tank from the humidifier.
- Empty any remaining water from the tank.
- Refill the water tank with clean, cold tap water. Do not exceed the maximum water level indicated on the tank.
- Replace the tank cover and ensure it is securely closed.
- Insert the water tank back into the humidifier.
- Plug the humidifier back into the electrical outlet and turn it on.
-
Remove the tank cover and fill the tank with room-temperature water. Note:
-
Purified or distilled water is recommended. Using tap water is also acceptable but may require frequent cleaning and maintenance if your tap water is hard.
-
DO NOT overfill the water tank to it overflowing.
CAUTION -
DO NOT add water through the mist tube.
-
DO NOT add water directly into the base chamber.
-
DO NOT add essential oil into the humidifier.
-
ONLY add essential oil to the aroma pad.
-
-
Replace the tank cover and place the water tank to the base.
Use Your Humidifier
- Ensure the humidifier is plugged into an electrical outlet and turned on.
- Press the On/Off button to turn on the humidifier.
- Tap the Mist Level button to choose your desired cool mist level (Medium, High, or Low).
- If desired, tap the Heating button to turn on the warm mist function and select your desired warm mist level (High, Off, Low, or Medium).
- The humidifier will start producing mist according to the selected mist levels.
-
Plug in the humidifier. When connected to power, you will hear a beep sound and the humidifier will enter the standby mode.
-
Tap the On/Off Button to turn on the humidifier. The humidifier will start misting and its LED display will show the current humidity and temperature.
Note:- The combined medium cool mist and high warm mist is the default setting when the humidifier is turned on.
- Before connected to power, rotate the nozzles to adjust the direction of the mist.
- DO NOT rotate or cover the nozzles while the humidifier is on.
- DO NOT attempt to inhale the mist directly from the nozzles.
- If there is no water in the tank or the humidifier runs out of water, the machine will stop misting. Refill the tank (see Fill or Refill, page 7-8) and tap the On/Off Button to restart the humidifier.
-
Tap to select your desired mist levels or humidity levels. To select your desired cool or warm mist level, tap repeatedly the Mist Level Button or the Heating Button. To select your desired humidity levels, tap repeatedly the Humidity Button or tap the Auto Button to auto control the humidity level at a relative comfortable humidity of 60%. (see Controls, page 4-7)
Note:- When your room has reached your preferred humidity level, tap the Misting Level Button or Heating Button to lower its cool or warm mist level, or just turn it off (see Controls, page 4-7).
- The humidifier stops misting in Auto Mode if the humidity level is above 60% (see Controls, page 4-7).
-
Optionally, use the controls to set an auto-off timer, activate Sleep Mode or Child Lock, and more. (see Controls, page 4-7)
-
Tap the On/Off Button to turn off the humidifier.
(Optionally) Use the Aroma Box
The Hybrid Ultrasonic Humidifier H111 comes with an aroma box to add essential
oils to enhance your experience. Follow these steps to use the aroma box:
- Turn off the humidifier and unplug it from the power outlet.
- Pull out the aroma box at the bottom of the base.
- Add 2-3 drops of essential oil on the aroma pad.
- Replace the box into the humidifier.
- Plug in and turn on the humidifier.
Note:
- DO NOT add essential oil, supplemental water treatment liquids, or third-party water filters into the water tank or base.
- ONLY add essential oil to the aroma pad.
- The aroma pad can be cleaned and reused after diffusing essential oil.
Cleaning & Maintenance
Regular cleaning and maintenance of your humidifier are essential to ensure optimal performance and prevent the buildup of bacteria or mold.
Follow these steps to clean your Hybrid Ultrasonic Humidifier H111:
- Turn off the humidifier and unplug it from the electrical outlet.
- Remove the water tank and empty any remaining water.
- Remove the mist nozzle, sponge filter, and aroma pad (if used).
- Clean the water tank, mist nozzle, sponge filter, and aroma pad (if used) with mild soap and water.
- Rinse thoroughly to remove any soap residue.
- Wipe the exterior of the humidifier with a soft, damp cloth.
- Allow all parts to air dry before reassembling.
CAUTION:
- If the humidifier is not in use for over 2-3 months, it must be cleaned up before use, or the bad water quality might lead to inferior mist and malfunctions.
- Make sure the humidifier is unplugged f rom any power source before cleaning.
- The water in the base near the atomizer may still be warm after turning off the humidifier. Be cautious about using when pouring out the water.
- DO NOT touch the nozzles before the humidifier completely cools down.
- DO NOT rub the atomizer with hard or abrasive objects.
- Clean your humidifier at least once a week. Rinse out the water tank every time before you use it.
- DO NOT use detergents to clean the humidifier; ONLY use distilled white vinegar or citric acid.
- Purified or distilled w ater is r ecommended. Using tap w ater is also acceptable but may require frequent cleaning and maintenance if your tap water is hard.
Cleaning the Humidifier
- Turn off the humidifier.
- Drain the remaining water in the tank and the base.
- Cleaning the humidifier and its parts.
- Change a new one when the anti-scale pad has turned hard.
-
Clean the base and tank cover
Please clean any water drops and dirt with a damp cloth then wipe them dry with a clean, dry cloth or tissues. -
Clean the water tank and water valve
Add water to the water tank and rinse it thoroughly. Use the included brush to gently wipe dirt (like scale on the bottom) that cannot be removed normally. -
Clean the steam hood and anti-scale pad
Remove the steam hood and anti-scale pad from the main unit and rinse them under clean, running water. For stubborn scales, place the steam hood in a small container. Fill with citric acid and warm water (ratio 1: 20) to cover and soak it for 10-15 minutes. Wipe them gently with the included brush, and clean them with a damp cloth until any acid smell is completely gone.
Note: DO NOT forget to reinstall them on the main unit before operation, or it may cause malfunction. -
Clean the main unit, float, and atomizer
For dirt that is hard to be removed, fill the main unit with citric acid and warm water (The ratio is 1: 20) and soak for 10-15 minutes. Pour the liquid, then wipe and clean the main unit until any acid smell is completely gone. -
Clean the sponge filter and holder
1. Rotate to remove the sponge filter holder.
2. Wipe the sponge filter holder with the included brush or a damp cloth, and rinse it until dirt has gone.
-
Clean the aroma box
Pull out the the aroma box and rinse the aroma pad under warm, running water.
Note:- DO NOT pour liquid detergents into the aroma pad.
- It is recommended to change the aroma pad every 6 months.
-
Dry the main unit and other parts
Wipe them with dry cloth after cleaning and let them air dry in a cool indoor place. Water remaining on the surface or inside the device may lead to smelly odors and mold.
Note:- DO NOT submerge the base in water.
- DO NOT allow water inside the air flue or air outlet to prevent damage to the humidifier
-
Storage
Store the device in a dry place without direct sunlight.
Note:- DO NOT store the device when it is not thoroughly dry. Doing so may cause bad odors and mold.
Maintenance
- Clean your humidifier at least once a week if you are using it on a regular basis to prevent any bacterial or mold growth.
- Always rinse out the water tank and change water before each use.
- It is recommended to use distilled water with the humidifier to prevent white residue around the area where your humidifier is being used.
- Clean and drain the humidifier before storage to prevent bacterial and mold growth.
Troubleshooting
Problem | Possible Solutions |
---|
The humidifier doesn’t turn on, or stop misting unexpectedly.
| Plug in the humidifier and turn it on.
Add purified or distilled water to the water tank.
Check to see if the humidifier is in Auto Mode. Depending on Auto Mode
settings, the humidifier will automatically turn off when the humidity level is
above the target level.
Display shows an incorrect humidity percentage.| The room may be larger than
the humidifier’s effective range.
Move to a smaller room.
Little or no mist comes out.
| Turn the mist level to a higher setting.
Fill the water tank.
There may be too much water in the base chamber. Empty the base chamber. Refill
the water tank and place it properly onto the base.
Make sure the humidifier is not set on carpet or other surfaces that may block
air flow.
Make sure the nozzles are not blocked or clogged.
Make sure the humidifier is on a level surface.
While the room or water temperature is too low, a low mist level
is expected.Turn the mist level
to the highest setting and let the humidifier run for a while,
then adjust to the desired setting.
If the water tank or base was washed with detergent, rinse thoroughly with
clean water to remove any detergent.
Make sure no oil is sticking to the PTC heater, atomizer, or
bottom of the water tank. If so, please clean it up.
Problem | Possible Solutions |
---|---|
Humidifier uses water too quickly. | The humidifier uses up water based on the |
environmental temperature and humidity. If your environment is cold and/or dry, the humidifier will run out of water faster.
Humidifier produces an unusual smell.
| If the humidifier is new, unplug and rinse its detachable parts,
then place in a cool, dry place for 12 hours.
If essential oil was added on the aroma pad, rinse the pad under clean water
and allow it to dry.
Clean the water tank and base chamber
(see Cleaning & Maintenance, page 10-13).
Mold grows inside
the humidifier.
| Clean the water tank and base chamber regularly
(see Cleaning & Maintenance, page 10-13).
Essential oil has little or no smell.| Add more drops of essential oil.
For best results, use pure essential oil.
Humidifier makes a loud or unusual noise.
| Make sure the water tank is properly in place
(see Fill or Refill, page 7- 8)
Set mist level to a lower setting.
Empty the base chamber. Refill the water tank and place the
water tank properly onto the base.
The humidifier may be malfunctioning. Stop using the humidifier and contact us:
support@homvana.shop
White dust appears around
the humidifier.
| We recommend using purified or distilled water to fill the humidifier.
Avoid using water with high mineral content.
Clean the humidifier (see Cleaning & Maintenance, page 10- 13).
Water leaks from the humidifier.
| Make sure the water valve is securely placed.
---|---
Avoid running the humidifier in a room with over 60% relative
humidity.
Wipe any excess water off the top and bottom of the base.
DO NOT shake the humidifier.
Make sure to place the humidifier on a flat, level surface.
Check the water tank for leaks. If there are leaks, contact us:
Unscrew the water valve and clean it ( see Cleaning & Maintenance, page 10-13 ). Put the water valve back before restarting your humidifier.
Condensation forms around humidifier
or windows.
|
Humidity may be too high. Turn down the mist level, turn off the humidifier, or open a door or window to the room.
Problem
The humidifier is not producing mist.
Error Code
- Error code: E1
- Possible Cause: The water tank is empty or not properly installed.
- Solution: Refill the water tank and ensure it is properly installed.
Warranty
Thank you for choosing Homvana Hybrid Ultrasonic Humidifier.
At Homvana, we use only the highest-quality materials, giving us the
confidence to provide you with:
- 30-day money-back guarantee
- Industry-leading 3-year warranty
- Lifetime technical support
This product is covered by a limited warranty. For more information about the warranty or to make a warranty claim, please contact us at support@homvana.shop.
Whatever you need, we’re here to help. Just get in touch with us at:
support@homvana.shop
@homvanaofficial
Each item is 100% inspected before despatch. It’s normal sometimes to find water mist or beads left from pre-shipment testing. Beware of damage from dropping. Don’t hesitate to contact us if you receive broken items or missing accessories. You will get timely assistance, replacement or refund. We promise to make things right with our wholehearted service.
FAQ
Q: Can I add essential oil to the water tank?
A: No, you should not add essential oil, supplemental water treatment liquids,
or third-party water filters into the water tank or base. This can cause
damage to the humidifier and leaks. Only add essential oil to the provided
aroma pad.
Q: How do I change the mist levels?
A: You can change the cool mist levels by tapping the Mist Level button on the
humidifier or remote controller. The options include Medium, High, and Low.
The default setting is Medium when the humidifier is first turned on.
Q: How do I clean the humidifier?
A: To clean the humidifier, turn it off and unplug it from the electrical
outlet. Remove the water tank, mist nozzle, sponge filter, and aroma pad (if
used). Clean these parts with mild soap and water, then rinse thoroughly.
Allow all parts to air dry before reassembling.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>