Homvana H102 Ultrasonic Humidifier User Manual
- June 14, 2024
- Homvana
Table of Contents
Ultrasonic
Humidifier
User Manual / Model H102
Safety Information
READ AND SAVE THESE SAFETY WARNINGS & INSTRUCTIONS
IMPORTANT: Please read, understand and comply with all of the instructions in
this manual, or it may result in serious injury and/or damage to the product.
If the humidifier is damaged or if it is not functioning properly, please
contact us
support@homvana.shop
Before Use
- Keep the humidifier out of reach from children.
- ONLY use this humidifier as described in this manual.
- DO NOT use unofficial or mismatched adapters, or it may cause malfunction and lower performance
While Using
- DO NOT use this product in wet environments,
- DO NOT place the humidifier near sources of heat, such as stove tops, ovens, or radiators,
- DO NOT place the humidifier near any large pieces of furniture or in any high-traffic area where it can be easily knocked over
- ALWAYS place the humidifier on a flat, level, water-resistant surface , efore operation
- DO NOT plug in the unit with wet hands.
-
- DO NOT fill past the tank’s max water line, or it may cause less/no mist output.
- DO NOT shake the humidifier while using.
- DO NOT cover the nozzle and air inlet while the humidifier is on.
- DO NOT direct the nozzles to the air inlet to prevent mist from damaging the fan
(Caution: Risk of Leaks and Electric Shock )
DO NOT add essential oils, supplemental water treatment liquids, or third-
party water filters into the water tank. This will damage the humidifier and
cause leaks. ‘ONLY add essential oils to the aroma pad.
After Use
- ALWAYS unplug the humidifier when not in use, or while cleaning it out
- DO NOT immerse the humidifier main unit, power cord, or plug in water.
- DO NOT use detergents to clean the humidifier; ONLY use distilled white vinegar
- DO NOT place foreign objects into the main unit or water tank.
- DO NOT use other items as replacement parts for this product
Getting to Know Your Humidifier
Package Contents
Homvana Ultrasonic Humidifier H102 x 1
Power Adapter x 1
User Guide x 1
Quick Start Guide x 1
Cleaning Brush x 1
Aroma Pad (1 pre-installed) x 3
Specifications
Model | H102 |
---|---|
Input Voltage | AC100V-240V, 50/60Hz |
Output Voltage | DC24V=10A |
Rated Power | 24W |
Water Tank Capacity | 50L/132gal |
Effective Range | 323ft?/30m? (Max) |
Cool Mist Output | 100mL/h-260mL/h |
Product Overview
Controls
Power Button
Tap the Power Button to turn your humidifier on/off.
Note: High mist is the default when the humidifier is turned on.
Timer Button
Humidifier will automatically shut off when reaching the time set.
Tap repeatedly to set the timer among 2H, 4H, 8H, 12H, 14H und OH.
Note:
- Once selected your desired time, the display will alternately flash the remaining auto-off time and the current relative humidity until the humidifier is automatically powered off.
- To cancel the timer, press the Timer Button for 2s until the display flashes “00″.
- To confirm your selection, the timer display will flash 3 times.
Operation | 1st Tap | 2nd Tap | 3rd Tap | 4th Tap | 5th Tap | 6th Tap |
---|---|---|---|---|---|---|
Display | 2H | 4H | 8H | 12H | 14H | OH/Off |
Operation | Press for 2s to cancel the timer. | |||||
Display | Flashes “00° and then shows the current relative humidity and mist |
level.
Light Button
Tap repeatedly to change the color of tank light.
Note:
- When the humidifier is turned on, the tank light cycles through 7 colors by default.
- Toturn off the light, keep pressing the Button until the light goes out.
Operation| 1st Tap| 2nd Tap| 3rd Tap| 4th Tap| 5th Tap| 6th Tap| 7th Tap|
EtthTap
---|---|---|---|---|---|---|---|---
Tank Light| Blue| Yellow| Purple| Cyan| White| Red| Green| Off
Sleep Button
Operation | 1st Tap | 2nd Tap |
---|---|---|
Tank Light | Off | On |
Display | Flashes SL for Ss then off. Dim his displayed | Shows current relative |
humidity
Auto Button
Tap to turn on/off the Auto Mode. The humidifier will produce mist as needed
to maintain a comfortable relative humidity (RH) percent of 60% by default.
Note:
- Timer and Light can be used with Auto Mode.
- Tap the Auto Mode Button, Mist Level Button or Sleep Mode Button to cancel the Auto Mode.
Relative Humidity | Mist Level |
---|---|
<43% RH | High Level Mist |
4396-62% RH | Medium Level Mist |
>6296 RH | Low Level Mist |
Mist Level Button
Tap repeatedly to change the cool mist levels: High, Low and Medium.
Note:
- High level is the default setting when the humidifier is first turned on.
Getting to Use Your Humidifier
Setting up
Place the humidifier on a level, elevated, and water-resistant surface, such
as a table or nightstand. Make sure the room is well-ventilated.
Note:
- Position the humidifier at least 30-cm /12-in away from walls and appliances to prevent them from getting wet.
- Direct the nozzles away from any furniture to prevent your furniture from getting wet
Filling or Refilling
-
Remove the main unit and fill the tank with room-temperature water more than 300mL.
-
Directly refill the water tank through the top water inlet with water less than 300mL.
Note:
• Purified or distilled water is recommended . Using hard water will require frequent cleaning and maintenance.
• DO NOT fill past the tank’s max water line. -
Put the main unit back to the tank
CAUTION
- DO NOT add water through the nozzle.
- DO NOT add essential oils into the water tank and nozzle.
- ONLY add essential oils to the aroma pad.
Using Your Humidifier
-
Plug the humidifier into a power outlet. When connected to power, the display will light up for 3s then go off. The humidifier will enter the standby mode.
-
Tap the Power Button to turn on the humidifier. The humidifier will start misting.
Tap the Mist Button repeatedly to change the mist level (see Controls, page 4-7).
Note:
• DO NOT attempt to inhale the mist directly from the nozzles.
• When the humidifier runs out of water, it will stop working. And there should still be a thin layer of water to prevent the atomizer from dry burning. Pour out the water, refill the tank (see Filling or Refilling, page 8-9) and restart the humidifier.
• Ifthe main unit is removed when the humidifier is turned on, the machine will stop working. Place the main unit back and tap the Power Button. The humidifier willrestart working, -
Optionally, use the controls to set an auto-off timer, activate Sleep Mode or change the color of the tank light, and more. (see Controls, page 4-7)
-
Tap the Power Button to turn off the humidifier.
(OPTIONALLY) Doing Aromatherapy
- Turn off the humidifier.
- Push the aroma box on the side of the main unit and pull it out.
- Add 2-3 drops of essential oil on the pad.
- Replace the box into the humidifier.
- Fill the water tank (see Filling or Refilling, page 8-9) and turn on the humidifier.
Note:
- DO NOT add essential oils, supplerental water treatment liquids, or third-party water filters into the water tank.
- ONLY add essential oils to the aroma pad. The aroma pad can be cleaned and reused after diffusing essential oils.
Cleaning & Maintenance
CAUTION:
- Make sure the humidifier is unplugged from any power source before cleaning
- DO NOT rub the atomizer with hard or abrasive objects.
- Clean your humidifier at least once a week. Rinse out the water tank every time before you use it.
- DO NOT use detergents to clean the humidifier.
- Recommend using clean or distilled water instead of tap water to prevent scale buildup.
Cleaning the Humidifier
-
Unplug the humidifier and remove the main unit from the water tank.
-
Pour out any water from the water tank.
-
Dampen a cloth and wipe the water tank. Rinse the water tank under clean, running water until any dirt is completely gone.
-
Remove the atomizer cover. Dampen the included brush and gently brush to descale the atomizer. Make sure the atomizer is well cleaned, or it might cause a decline in mist output.
Note:
• DO NOT submerge the main unit in water.
• DO NOT allow water inside the air outlet to prevent damage -
Dry all parts with a clean, dry cloth. Make sure all parts of the humidifier are completely dry before reassembling or storing.
-
Store the product in dry and cool place.
Cleaning the Aroma Pad
- Press and pull out the aroma box.
- Remove the aroma pad and rinse under warm, running water.
- Dry the pad with a clean cloth and place it back into the aroma box.
Note:
• DO NOT pour liquid detergents into the aroma pad.
• It is recornmended to change the aroma pad every 6 months.
Maintenance
- Clean your humidifier at least once a week if you are using it on a regular basis to prevent any bacterial or mold growth
- Always rinse out the water tank before each use. Changing the water each time you use the humidifier.
- It is recommended to use distilled water with the humidifier to prevent white residue around the area where your humidifier is being used.
- Clean and drain the humidifier before storage to prevent bacterial and mold growth.
Troubleshooting
Problem | Possible Solutions |
---|
Humidifier stops workingor sprays less mist while thereisstilla thinlayer of
water.| It is a systematic routine. The thin-layer water is calculatedly
remained to prevent the atomizer from dry burning. Pour out the remaining
water and refill the water tank
No mist comes out of the
nozzles.
| Plug in the humidifier and turn it on.
---|---
The water in the tank is too little to prevent the atomizer from dry burning.
Please fill the water tank.
Clean the humidifier (see Cleaning the Humidifier, page 77-73).
Water may be in the air outlet. Take the main unit off the water tank and
allow the outlet to fully air dry before using it again.
Do not fill past the tank’s MAX water line.
Only a small amount of mist comes out of the nozzles.| Clean the humidifier,
especially the atomizer (see Cleaning the humidifier, page 77-73) .
Do not fill past the tank’s MAX water line.
The water in the tank is too little to prevent the atomizer from dry burning.
Please fill the water tank.
Unclog the air inlet in the aroma tray.
Humidifier produces an unusual smell.| If the humidifier is new, remove the
main unit, and place the water tank in a cool, dry place for 12 hours.
If essential oils were diffused, rinse the aroma pad under clean water, and
allow it to dry.
Clean the humidifier (see Cleaning the Humidifier, page 11-13).
Humidifier
makes a loud or unusual
noise.
| Make sure the water tank is properly in place (see Filling or Refilling,
page 8).
---|---
Place humidifier on a flat, level surface.
Add at least 1000mL of clean or distilled water to the water tank.
The humidifier may be malfunctioning. Stop using the humidifier and email us:
support@homvana.shop
White scale appears around the humidifier.| We recommend using purified or
distilled water to fill the humidifier. Avoid using water with high mineral
content.
Clean the humidifier (see Cleaning the Humidifier, page 11-13).
Humidifier runs out of water
too quickly.
| The humidifier uses up water based on the environmental temperature and humidity. If your environment is cold and/or dry, the humidifier will run out of water faster.
Ifyour problem is not listed, please contact us: support@homvana.shop
WARRANTY
Thank you for choosing Homvana Ultrasonic Humidifier HI02. At Homvana, we use
only the highest-quality materials, giving us the confidence to provide you
with:
30-day money-back guarantee
Industry-leading 3-year warranty
Lifetime technical support
Whatever you need, we’re here to help. Just get in touch with us at:
support@homvana.shop
@homvanaoff
You will get timely assistance, replacement or refund. We promise to make
things right with our wholehearted service.
Any questions? Email us or go live chat. We’ll respond within 24h.
support@homvana.shop
@homvanaofficial
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>