Clean Air Optima CA-602 Ultrasonic Humidifier Ionizer Aromatherapy Instruction Manual
- June 16, 2024
- Clean Air Optima
Table of Contents
Instruction Manual Ultrasonic
Humidifier
with Ionizer and Aromatherapy
CA-602
Thank you for purchasing the innovative Clean Air Optima CA-602 ultrasonic
humidifier with Ionizer.
We wish you many years of healthy indoor air with this efficient and effective
product.
Ensure that all safety precautions are followed when using this electrical
appliance for the proper operation of the device. These instructions describe
the safety precautions to be observed during operation. They are designed to
prevent injuries or damage to this device.
Safety Precautions
-
The inner ultrasonic transducer is highly sensitive. Do not touch it with bare fingers or scrape it with metal tools, or it will reduce mist output. When cleaning this area please use a small cleaning brush, cotton swab or tooth brush. Do not use hot water as it may damage the misting parts.
-
Use proper voltage – AC 110~120V 60Hz in Canada/USA; AC 220~240V 50Hz in Europe.
Use of improper voltage may cause fire hazard or electric shock. -
To prevent electric shock, do not dismantle, repair or modify this product. Maintenance and cleaning should be followed exactly as instructed in this manual. In the event of a malfunction, please contact an authorized Clean Air Optima maintenance center.
-
Do not use in areas where flammable or explosive materials are stored.
-
Do not place this device in direct sunlight or near objects that generate high temperature heat. The heat may cause deformation or warping of the outer casing.
-
Do not use the humidifier in a room that already has humidity levels above 50% relative humidity. Excessive humidity in the room gives rise to condensation on cold surfaces such as walls or windows.
-
Do not operate the unit without water in the basin.
-
Do not insert foreign objects into the device. Do not touch the transducer or the lower water basin when the unit is operating. Do not scratch the transducer. Do not touch the mist output when producing warm mist.
-
Do not submerge this device in water. Water or cleaning liquids may only be used on parts to be cleaned according to the cleaning and maintenance instructions.
-
Only use lime scale remover or vinegar to clean mineral deposits from the basin or transducer. Do not use any harsh detergents that may damage the unit.
-
If you smell an abnormal odour, please turn off and unplug the unit and call Clean Air Optima technical support.
-
Clean and dry the device before storage (including the removal of all water from the inside of the device). Store the machine in a cool and dry place outside the reach of children.
-
Do not use fabrics or other materials to cover this device. Obstructed air inlets and outlets will result in improper operation of this unit and may result in fire or other damage.
-
To prevent interference and damage to other electronic devices, this machine should be placed at least 1 meter away from a computer, television, radio or other electronic equipment.
-
The ultrasonic humidifier should be cleaned regularly for proper operation and long life. See cleaning instructions.
-
The high frequency vibrations cannot be heard by humans or animals, and are completely safe.
-
For safety reasons and to prevent fire or electric shock, unplug the power cord from the electric outlet socket whenever you:
– Do not use the device for a long period of time.
– Remove the tank, clean or service the machine or the permanent filter.
– Move or transport the device.
If the power cord is damaged, then it must be replaced by an authorized service person to prevent electric shock or fire.
Diagram humidifier CA-602
Aromatherapy
Important
In order to reach the best results and to enjoy your CLEAN AIR OPTIMA
ultrasonic air humidifier as much as possible, we advise to read carefully the
following instructions regarding the use of essential oils in the ultrasonic
air humidifier CA-602 by CLEAN AIR OPTIMA.
Use of essential oils in the CLEAN AIR OPTIMA CA-602
Use our high quality essential oils and enjoy your personal aromatherapy! A
scent sensation at its highest level!
You can find high quality essential oils in our assortment. They perfectly fit
to the CLEAN AIR OPTIMA ultrasonic air humidifier CA-602 and have been
specially developed for the use with this ultrasonic humidifier. To order:
www.cleanairoptima.co.uk
www.cleanairoptima.com
Effectiveness
Essential oils (also called volatile oils) stimulate our olfactory sense
through their volatility and are perceived as aromatic. Essential oils
naturally evaporate with time.
The air humidifier CA-602 by Clean Air Optima works according to the newest
nebulisation technology based on ultrasound in order to atomise essential oils
and water into microscopically small drops. Thanks to this technology the
components and the water can unfold their beneficial potential for humans.
Filling and refilling with essential oils: Open the aroma box at the
backside of the device, pour 5 – 10 drops of your favorite essential oil on
the pad and close the aroma box. In order to reach the best effect, please
ONLY use the high quality essential oils and compositions from the Clean Air
Optima assortment.
Warning!
The use of other essential oils not made for this air humidifier or other
additives (for example pure essential oils, fragrances, water purification
products) can damage the air humidifier and must NOT be used! Even a small
quantity can damage the plastic and cause cracks. The material is not made for
the use of additives. One drop is enough to damage the water tank/ basin and
disable the device. Devices that are damaged through additives are excluded
from the guarantee.
The Clean Air Optima CA-602 is equipped with a Permanent Reusable White Dust &
AntiMicrobial Filter. It consists of an inner cylinder, an outer cover and a
number of small plastic and ceramic balls. The plastic balls are embedded with
nano-silver, an anti-microbial agent designed to purify the water and destroy
microbes such as bacteria and mould. The ceramic balls function to soften the
water by adhering to minerals that cause white dust. They also serve to remove
any unpleasant odour from the water. The filter requires cleaning about once a
month or 1,000 hours of use. See the Maintenance section of more information.
Operating Instructions
Before getting started, please remove the Clean Air Optima CA-602 from its box
and allow it to become accustomed to the room temperature for at least 30
minutes especially if the machine is cold from the outside air. The CA-602 is
designed to operate at temperatures between 5 -40 ºC and relative humidity of
less than 80%.
To get started, first remove the nozzele than flip the tank over and unscrew
and remove the watertank lid and filter.
Then place the water tank under the faucet for filling. Fill the tank with tap
water (or other clean water source with water temperature under 40ºC), re-
insert the lid and filter. Flip the water tank once again until it is on the
right side up. Ensure that the basin is clean and then carefully place the
water tank back on the lower body.
Wait a few seconds until the water tank lid starts to release water into the
basin. You will hear a bubbling sound as the air enters the water tank. Plug
the power cord into the electrical outlet (NEVER SWITCH ON THE HUMIDIFIER
WITHOUT WATER IN THE BASIN).
Turn the “Power knob ON/OFF” to the right to turn the humidifier on. The water
will be turned into micro-fine steam trough high frequency vibration, which
will be dispensed into the indoor air and directly evaporates. Make sure that
the steam does not face electrical sockets, walls or other objects.
Turn the “Max – Mid – Min knob” to the right to adjust the amount of mist
output.
Push the “ION” button to turn the Ionizer and LED light on.
The air will be enriched with additional negative ions. The integrated ionizer
cleans and refreshes the air with additional negative oxygen ions. The effect
is completely natural: After a summer thunderstorm the air is filled with
negative ions and especially fresh.
Amount of ions per cubic centimetre air:
In high altitude: 8000 ions /ccm
At sea level: 4000 ions / ccm
Countryside: 1200 ions / ccm
In the city: 2000 ions / ccm
In the office: Only 20 ions / ccm
In case there is no or too little water in the tank you will hear a signal.
Humidity
The percentage of water steam in a room and the temperature are the relative
air humidity. The air contains more or less air humidity. The ration of water
steam to the air varies with the different temperature. The higher the
temperature in the room, the less water steam will be in the air. In winter
the cold air from outside enters the room, the relative air humidity
decreases. The air humidity can be increased with the Clean Air Optima air
humidifiers.
The relative air humidity should be:
Bed and living room: 45 -60 %
Examination room: 40 – 50 %
Library: 40 – 50 %
Troubleshooting
The following is a troubling shooting guide to help you solve any issues that you may have with the operation of the Clean Air Optima CA-602.
Trouble | Possible reasons | Solution |
---|---|---|
Power icon is off or does notwork. | Humidifier not plugged into the power | |
outlet. | Connect power cord to electrical outlet and turn rotary knob. | |
Power light is on but no mist. | No water in water tank. | Fill water tank with |
water.
The mist has a strange odour.| A new machine.
It either has dirty water or the water has been stagnant too long.| Remove the
water tank, unscrew the lid and let it air out in a cool area for 12 hours.
Clean the water tank and refill with clean water.
Power light is on, but the machine doesn’t work.| Too much water in the water
basin.| Remove the water tank. Take a small cup and remove some of the water
from the machine’s water basin. Reinsert the water tank and make sure that it
sits properly.
The volume of spray mist is too low.| Too much mineral scale in the water
basin.
Water is too dirty or water was kept toolong in the tank.| Clean transducer.
Clean the water tank and refill with clean water.
Abnormal noise| Vibration in the water tank because the water level is too
low.
Machine is on an unstable surface.| Fill the water tank.
Move the unit to a stable flat surface.
Spray mist is coming out of the area around the jet.| There are gaps between
the housing around jet nozzle and the top of the water tank.| Remove the jet
nozzle from the top of the water tank and clean with a damp cloth. Reattach to
the water tank.
The following is not considered faulty operation:
- If your water is very hard (containing abnormally high levels of minerals) the humidifier may produce white dust. This is not a malfunction. The solution would be to clean the filter more often or use softer water.
- If you stand very close to the humidifier, you will hear the gurgling sound of water. This is normal.
- The machine operates very quietly but it is not completely silent. Noise levels less than 25 db is considered normal.
WARNING!
If the above recommended solutions do not work, please contact Clean Air
Optima technical support at the telephone number for your region. Do not
attempt to disassemble, repair and reassemble the machine as it may void the
warranty.
Cleaning and Maintenance
You can ensure many years of trouble free operation of your Clean Air Optima
CA-602 humidifier by following a few simple maintenance procedures. If your
water is hard, containing high concentrations of calcium and other minerals,
then over a period of time white dust will start to deposit on the various
surfaces in the room. A white, film-like substance will also start to develop
in the water basin, on the transducer and on the inner surface of the water
tank. This white film will impede the proper function of the transducer and
the operation of the machine.
We recommend the following
-
If your water is very hard, we recommend that you boil it first, allow it to cool completely before use in the humidifier. The boiling will reduce the mineral concentration in the water.
The other option is to use distilled water if your mineral level is still too high. -
If you are using the machine on a daily basis, clean the transducer, water tank and basin once a week.
-
When the water tank needs a refill, empty the remaining water from the tank and fill it with fresh water.
-
Clean the whole machine and make sure to keep all the parts completely dry when the machine is not in use.
How to clean the transducer
- Place 5-10 drops of vinegar on the surface of the transducer and wait for 2-5 minutes.
- Using a small brush, cotton swab or tooth brush, gently clean the mineral film from the surface of the transducer.
- Rinse the transducer with clean water.
- Never use sharp or solid objects for cleaning the transduce
How to clean the water basin
- Clean the water basin with a soft damp cloth. If there is excess film on the surfaces, then soak the cloth with vinegar and repeat the process.
- If there is a film in any of the depressions along the basin, drop a bit of vinegar into depression and clean it out with a brush.
- Rinse the basin with clean water.
How to clean the White Dust & Anti-Microbial Filter
- Remove the filter from the water tank.
- Put some white vinegar into a glass. Soak the filter in the vinegar for about 10 minutes.
- Remove the filter from the glass and shake it several times.
- Clean and rinse the filter once again with fresh water.
If you don’t plan to use the humidifier for a long time, remove the filter
from the water tank and let it dry thoroughly. Then wrap it in protective
packaging and keep it next to the humidifier in a cool, dry and dark storage
space.
Why humidify the Air?
When the air is dry, especially in the winter months, it can become
unpleasant and even unhealthy, leading to increased levels of static
electricity, dry skin, cracked lips and even noise bleeds.
Optimal humidity is between 45 to 55% relative humidity. During the winter
months though, relative humidity in the average home can drop to below 20%.
Low humidity can lead to a variety of conditions that cause ill health. Dust
particles, bacteria, viruses, dust mite feces that are normally trapped by the
moist nasal membrane lining in the nose can more easily get into the lungs
when the air is dryer and thus reduce the body’s natural defence mechanism.
These invaders overload the immune system and irritate the mucous membranes
resulting in more coughing and susceptibility to disease. The Clean Air Optima
CA-602 is an ideal ultrasonic humidifier for homes, apartments, offices and
anywhere where is low humidity. Ultrasonic water vapour is highly beneficial
to individuals. Their biggest advantage is high performance combined with low
energy consumption.
Do not use additives
Water additives (e.g. essential oils, fragrances, water conditioners etc.)
must NOT be used! Even a small amount can cause damage to the tank material.
The material is not suitable for the use of such additives. One drop is enough
to damage the tank and render the appliance unusable. Appliances that are
damaged by such additives will not be covered by the manufacturer’s warranty.
The major benefits
- Air humidification and air purification, refreshes and improves indoor air quality
- 3-in1: Humidification, Purification and Aromatherapy!
- Permanent ceramic / nano-silver filter: no replacement filters needed!
- Built-in Ionizer purifies the air additionally and provides fresh air
- Vitually silent operation ensures a quiet and restful sleep
- The ultrasonic is hygienically flawless if cleaned regularly and the ceramic/nano-silver cartridge is cleaned as indicated
- Permanent, easy to clean ceramic nano-silver filter for control of white dust, mould and bacteria
- Safely and automatically shuts off when it runs out of water
- Large capacity water tank (3,5L) easy refills with normal tap water
- Runs up to 3 nights or 30 ours without refilling (low setting)
- Save money. No wicks or filters to replace!
- Low power consumption
Applicable for small and larger rooms up to 375 ft² / 35m² / 80m³
Benefits of proper humidification
- reduces discomfort, tiredness, sickness
- reduces susceptibility to colds
- reduces chapped lips, dry, red eyes and dry, itchy skin
- helps to feel and sleep better
- can help you recover sooner from a cold
- reduces damage to wooden objects
- reduces the negative effect of dry air on musical instruments
- reduces static electricity charge
- helps to keep your voice tuned
Benefits of ionisation
Ionised air strengthens our defence systems and our vitality and ionisation
purifies the air by reducing the particles, micro-organisms, viruses &
allergens!
Product specifications
- Type: Clean Air Optima CA-602
- Ultrasonic humidifier for cold mist capacity
- Mist Evaporation Rate: Low 120 ml / hr (3.4 fl oz) High 300 ml / hr (10.1 fl oz)
- Negative Ion Output: 3.000.000/cm³ (49.161.000/inch³)
- Active oxygen <0.05 ppm
- Water tank capacity 3,5L
- Very low noise level <25 dB
- Dimensions (LxWxH) 29,5 x 16 x 33,5 cm
- Weight: 1,7kg (8.2lbs) dry
- Color: white with transparent water tank
- Energy consumption only 30 watts
- Power supply 220 – 240V, 50/60 Hz
At the end of the product life cycle, you should not throw this machine into
the normal household garbage but bring the product to a collection point for
the recycling of electrical and electronic equipment.
CA-602 ULTRASONIC HUMIDIFIER with Ionizer and Aromatherapy
Date of purchase: ………………………………………………………………………………………………..
Customers name: ………………………………………………………………………………………………..
Address: …………………………………………………………………………………………………………..
Telephone: ………………………………………………………………………………………………………..
Email: ………………………………………………………………………………………………………………
Seller’s name: ……………………………………………………………………………………………………
Address: ………………………………………………………………………………………………………….
- Please fill in completely this Warranty Certificate. Send it with the invoice and the unit, postage pre-paid and using the original packing box, to your distributor. Make sure to include the appropriate return postage for the package.
- Please enclose a short description of the damage, fault or malfunction, and the circumstances under which these problems arose.
The Clean Air Optima CA-602 is subjected to strict testing procedures before
leaving the factory.
If within two years from the date of purchase the product does not perform
according to the specifications, because of factory defects, the purchaser is
entitled to free repairs or replacement ofparts upon presentation of this
warranty (provided that the alfunction or damage to the device and/or parts
occurred under normal operating conditions). What is covered: All parts
defective in material and workmanship. For how long: Two years from purchase
date. What we will do: Repair or replace any defective parts. Exclusions:
Regular replacement parts such as filter cartridges.
Other Conditions
The provisions of this warranty are in lieu of any other written warranty
whether express or implied, written or oral, including any warranty of
merchantability or fitness for a particular purpose. The manufacturer’s
maximum liability shall not exceed the actual purchase price paid by you for
the product. In no event shall the manufacturer be liable for special,
incidental, consequential, or indirect damages. This warranty does not cover a
defect that has resulted from improper or unreasonable use or maintenance,
faulty assembly, accident, natural catastrophes, improper packing, or
unauthorized tampering, alteration, or modification as determined solely by
us. This warranty is void if the label bearing the serial number has been
removed or defaced.
Clean Air Service Center
David Ricardostraat 9-9
7559 SH Hengelo (ov)
The Netherlands
Tel: + 31 (0) 74 – 2670145
Fax: + 31 (0) 74 – 2671789
E-mail: info@cleanairoptima.com
Internet: www.cleanairoptima.com
References
- AirMex Luftreinigung für Gewerbe, Büro, Handwerk und Industrie
- Internet, TV en Bellen | Online.nl
- Clean Air Optima
- Clean Air Optima
- Clean Air Optima
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>