SERVER CP-1/3 2oz Stainless Steel Pump Owner’s Manual

June 12, 2024
SERVER

ERVER Logo Stainless Steel Pumpto dispense portions up to 2oz
MODELS INCLUDE:
CP-1/3 2oz CP-200 2oz CP-200V 2oz
CP-6½ 2oz CP-8½ 2oz CP-10½ 2oz
CP-15L 2oz CP-F 2ozERVER CP 3 2oz Stainless Steel
Pump

Thank You for purchasing our Stainless Steel Pump.
This quality, NSF listed pump delivers larger portions with less effort and lasts for years of service.
CONSISTENT PORTIONS—SERVE BETTER
Your pump may vary depending on specific model number.

PUMP PARTS

ERVER CP 3 2oz Stainless Steel Pump - PUMP PARTS www.Server-Products.com

SAFETY

According to food and safety regulations, most foods must be stored and/or served at certain temperatures or they could become hazardous. Check with local food and safety regulators for specific guidelines.
Be aware of the product you are serving and the temperature the product is required to maintain. Server Products, Inc. cannot be responsible for the serving of potentially hazardous product.
IMPORTANT
Clean, rinse, sanitize, and dry parts daily or regularly to comply with local sanitization requirements.
NSF International list this pump as “Not acceptable for dispensing potentially hazardous foods.”

PUMP CLEANING

  1. FLUSH & RINSE
    all pump surfaces with hot water. Place lower end of pump into container of hot water and operate pump until all remaining product is expelled and only hot water is discharged.
    YES!
    Use dishwashing soap, hot water and nylon brush. Pump is dishwasher safe.ERVER CP 3 2oz Stainless Steel Pump - PUMP PARTS
1

  2. DISASSEMBLE & CLEAN
    all washable parts with soap and hot water.
    (See DISASSEMBLY on page 5.)
    USE SUPPLIED BRUSH to thoroughly clean inside discharge tube and any confined areas.ERVER CP 3 2oz Stainless Steel Pump - Pump

  3. RINSE
    fully with clean water.

  4. SANITIZE
    all parts according to local sanitization requirements. All parts in contact with food must be sanitized.ERVER CP 3 2oz Stainless Steel Pump - Pump
1

  5. AIR DRY
    all parts fully.ERVER CP 3 2oz Stainless Steel Pump - Pump
2

CLEAN-IN-PLACE PROCEDURE FOR PUMPS

  1. CLEAN
    • Pump out all (if any) remaining food  product from inside pump body.
    • Wash and rinse off outside of pump body.
    • Flush out and rinse inside of pump.
    • Place lower end of pump into container full of water and operate pump until all (if any) remaining product is expelled and only warm water flows from discharge tube.
    • Mix 2 tsp (10 mL) of dishwashing  detergent with 2 quarts (1.9 L) of hot tap water (approximately 110°F /43°C).
    • Place lower end of pump into cleaning  mixture. Pump until all cleaning mixture is expelled.ERVER CP 3 2oz Stainless Steel Pump -
CLEAN

  2. RINSE
    • Place lower end of pump into 4 cups (1 L) of hot tap water (approximately 110°F /43°C) and pump until all tap water is expelled.

  3. SANITIZE
    • Mix one 1 oz (30 mL) packet of KAY-5 Sanitizer/Cleaner (EPA REG No. 5389-

  1. with 2.5 gallons (9.5 L) of tap water (approximately room temperature).
    • Place lower end of pump into this  sanitizing mixture and repeatedly operate pump until 2 quarts (1.9 L) sanitizing  mixture is pumped through pump.
  1. RINSE
    • Place lower end of pump into 2 cups (.5 L) of hot tap water (approximately 110°F /43°C) and pump until all tap water is expelled.

CARE OF STAINLESS STEEL

This durable pump includes stainless steel components.
If you notice corrosion beginning on any stainless steel surface, you may need to change the cleansing agent, sanitizing agent, or the cleaning procedures you are using.

  • A mildly abrasive nylon or brass brush may be used to remove any stubborn deposits.
  • Fully rinsing and drying all parts can help prevent corrosion. Elements and minerals in tap water can accumulate on stainless steel parts and create corrosion.
  • Do not use abrasive, caustic or ammonia based cleansers.
  • Do not use products containing acids,  alkalines, chlorine, or salt. These agents can corrode stainless steel.
  • Do not use metal scrapers or cleaning pads that could scratch surfaces.

DISASSEMBLY

During disassembly, collect small parts in a container to prevent loss.
If pump has been in use, first rinse and flush pump. See PUMP CLEANING on page 3.

ERVER CP 3 2oz Stainless Steel Pump - CLEAN 1

  1. REMOVE CYLINDER & DISCHARGE TUBE
    Twist each counterclockwise to release from slots in valve body.

  2. REMOVE GASKET & O-RING
    from the valve body and bottom of discharge tube. Do not use a sharp tool.

  3. REMOVE PLUNGER & LID Turn locking collar (and discharge tube nut if used) counterclockwise to loosen and remove.

  4. DISASSEMBLE PLUNGER:
    REMOVE KNOBERVER CP 3 2oz Stainless Steel Pump - CLEAN
2Prevent knob from springing off:
    Press head tube towards piston base while twisting knob off.
    REMOVE LOCKING COLLAR REMOVE GAGING COLLAR(S) (if used).
    REMOVE HEAD INSERT from inside head tube. REMOVE SPRING & WASHER from piston.
    REMOVE SEAL ASSEMBLY from piston.
    Pry off.
    Do not use a sharp tool.
    REMOVE O-RING from inside seal.

ASSEMBLY

WASH ALL PARTS PROPERLY BEFORE EVERY USE. See page 3.

  1. PREPARE PISTON
    A INSTALL SMALL O-RING
    into seal.
    B INSTALL SEAL
    onto piston head.
    Apply food equipment lubricant to outside of seal.
    C SLIDE WASHER onto piston.
    D SLIDE SPRING onto pistonERVER CP 3 2oz Stainless Steel Pump -
CLEAN3

  2. PREPARE HEAD TUBE
    A OPTIONAL:
    ADD GAGING COLLAR(S) Slide collar(s) onto head tube to reduce portion size.
    See page 2 for PORTION CONTROL. B SLIDE LOCKING COLLAR (wide side down) towards flared end of head tube. C SLIDE HEAD INSERT
    (beveled edge first) into head tube.
    TIP: The end with smaller hole should go in first.

  3. INSERT PISTON ASSEMBLY
    into head tube assembly.

  4. INSTALL KNOBERVER CP 3 2oz Stainless Steel Pump - compressPress head tube down to compress spring and expose piston threads.
    Rotate knob clockwise to secure.

  5. INSTALL GASKET
    into valve body. Apply food equipment lubricant on gasket.
    TIP: Flat side of gasket should face up.![ERVER CP 3 2oz Stainless Steel Pump

  • compress 1](https://manuals.plus/wp-content/uploads/2023/06/ERVER-CP-3-2oz- Stainless-Steel-Pump-compress-1.png)

    1. INSTALL CYLINDER
      onto valve body.
      TILT edge of cylinder under nub on rim of valve body.
      FIT TABS on cylinder into corresponding notches in valve body.
      PRESS DOWN firmly and ROTATE cylinder clockwise to secure into slots.ERVER
CP 3 2oz Stainless Steel Pump - compress 2

    2. INSTALL O-RING
      onto discharge tube. Apply food equipment lubricant on o-ring.

    3. INSTALL DISCHARGE TUBE
      onto valve body. Rotate discharge tube clockwise and press down firmly to secure into slots on valve body.ERVER CP 3 2oz Stainless Steel Pump -
comprese 3

    4. INSTALL LID
      by sliding smaller lid hole over discharge tube.
      Align center hole with threads on cylinder.
      IF DISCHARGE TUBE HAS THREADS:
      To secure lid, slide discharge tube nut onto discharge tube.
      Rotate nut clockwise to secure.ERVER CP 3 2oz Stainless Steel Pump -
comprese4

    5. INSTALL PLUNGER ASSEMBLY
      into cylinder.
      Rotate locking collar clockwise onto cylinder threads to secure.ERVER CP 3
2oz Stainless Steel Pump - comprese 5

TROUBLESHOOTING

ERVER CP 3 2oz Stainless Steel Pump -PROBLEMS

SERVER PRODUCTS LIMITED WARRANTY
2 YEAR WARRANTY
This Server product is backed by a two-year limited warranty against defects in materials and workmanship. See Server-Products.com for details.
GENERAL SERVICE, REPAIR OR RETURNS
Before sending any item to Server Products for service, repair, or return, contact Server Products customer service to request a Return Authorization Number. Merchandise must be sent to Server Products with this number. Service is extremely prompt. Typically, units are repaired and ship out within 48 hours of receipt. Merchandise being returned for credit must be in new and unused condition and not more than 90 days old and will be subject to a 20% restocking charge.
NEED HELP?
Server Products Inc.
3601 Pleasant Hill Road
Richfield, WI 53076 USA
Chat with us!
[email protected]
262.628.5600 | 800.558.8722
Please be prepared with your Model, P/N and Series located on the lid or base of the unit.

ERVER Logo