Clean Air Optima CA-904G Design Fan Heater Clean Air User Manual
- June 3, 2024
- Clean Air Optima
Table of Contents
Clean Air Optima CA-904G Design Fan Heater Clean Air User Manual
Introduction
Thank you for purchasing the Clean Air Optima® Design Fan Heater CA-904G.
We wish you many years of healthy indoor air with this efficient and effective
product.
This product is only suitable for well insulated spaces or occasional
use.
This product is not suitable for use as primary heating.
These instructions describe the safety precautions to be observed during
operation.
They are meant to prevent injuries and to avoid damaging the device.
Description of the device
The device consists of the following main components:
-
Remote control signal receiver
-
Air outlet
-
Front cover
-
Base
-
Filter cover
-
Filter
-
Top cover
-
Control panel
-
Decoration display ring
-
Power cord
-
Power switch
-
Remote control holder
-
Control panel
-
Display panel
-
Remote control
Safety warnings
This device may only be used in accordance with these safety instructions. Take the following steps to minimize the risk of personal injury caused by for example electric shocks or fire.
-
Only for indoor use. Do not use or store outdoors.
-
The device is not intended to be used by children or persons with reduced physical-, sensory- or mental capabilities, unless they are supervised by a person responsible for their safety.
-
Children should be kept away unless continuously supervised.
-
CAUTION : Some parts of this product can become very hot and can cause burns.
Particular attention has to be given when children and vulnerable people are present. -
Warning: in order to avoid overheating, do not cover the heater.
-
The heater must not be placed immediately below a socket-outlet.
-
Do not use the device when there is visible damage on the electrical cord or on the device itself. Do not repair the device yourself in case of damage. Never pull the device by its cord.
If the power cord is damaged, then it must be replaced by an authorized service person to prevent electric shock or fire. -
Repairs may only be performed by authorized service personal. Do not try to repair the device yourself to prevent electric shock or fire.
-
Always remove the plug from the socket when the device is not being used or when you clean internal or external parts of it.
-
Only use power cords provided.
-
To safely use the device, put it in a steady, horizontal position. Do not move while using.
-
Do not use the device in rooms where inflammable liquids or gases are stored, close to heat sources or in particularly humid rooms like the bathroom, shower or swimming pool.
-
To prevent malfunctions, never insert strange objects into the device.
-
Never cover the air inlet and air outlet grid.
-
Never dissemble or replace the device’s inner parts.
-
To prevent injury or damage to the heater, do not touch the air inlet and outlet grille while the device is running and do not insert the handle or any other object into the air outlet.
-
Do not put heavy objects on the unit.
-
Do not place the device in direct sunlight, to avoid that the device discolors.
-
Never immerse the unit in water or other liquids.
-
Do not touch the power cord with wet hands.
-
Do not point the air outlet directly at a baby for a long time.
-
Do not place the device close to walls, curtains or other combustible materials, it may cause a fire.
-
When there is a unusual smell or unusual sound coming form the device, unplug the device from the power socket right away.
-
Do not use this heater if it has been dropped.
-
Do not use if there are visible signs of damage to the heater.
-
Use this heater on a horizontal and stable surface, or fix it to the wall, as applicable.
-
WARNING: Do not use this heater in small rooms when they are occupied by persons not capable of leaving the room on their own, unless constant supervision is provided.
-
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the device in a safe way and understand the hazards involved. Children shall not play with the device.
-
Cleaning and user maintenance shall not be made by children without supervision.
-
Children of less than 3 years should be kept away unless continuously supervised.
-
Children aged from 3 years and less than 8 years shall only switch on/off the device provided that it has been placed or installed in its intended normal operating position and they have been given supervision or instruction concerning use of the device in a safe way and understand the hazards involved. Children aged from 3 years and less than 8 years shall not plug in, regulate and clean the device or perform user maintenance.
-
WARNING: To reduce the risk of fire, keep textiles, curtains, or any other flammable material a minimum distance of 1 m from the air outlet.
-
Use, maintain and clean the device as described in this manual.
Product Features
-
Equipped with PTC ceramic heating element: this ensures that the air flow is automatically adjusted to the room temperature.
-
Adjustable Air flow and temperature:
Airflow: low – high
Temperature: cool – warm -
Timer function (1-12h)
-
Digital temperature control from 15°C to 35°C
-
Equipped with a Cross flow fan for silent operation
-
Tip-over safety protection, double over-heating protection
-
With Infrared long distance remote control function
-
Wide angel swing function
-
Automatic air supply, gentle breeze, smooth heating.
Installation and Operation instruction
The package contains: Main device (the base cannot be removed), remote control and instruction manual.
Assembling the device
- Take out the device from the package.
- Carefully put the device on a stable surface in upright position.
- The device needs to be positioned at least 30 cm from walls and furniture.
Function of keys
-
Plug in the device: you will hear an acoustic sound and the power symbol lights up.
-
In standby mode. Only the icon lights up. Press the key, the device starts working.
- The default situation after switching on:
- TC: Low heating power, icon lights up.
- Swing: Swing off, the icon is off.
- Timer: 0h(= no timer is set), the “ ” icon is off.
- Room temperature LED display “ ” lights up.
- Fan switches on.
- Temperature setting: default is set to 25°C
-
In operating condition, press the key to shift PTC from low heating power to high heating power. By pressing the key again, the PTC will switch back to low heating power.
- If working at low heating power: the low heating power icon lights up (the high heating power icon is off).
- If working at high heating power: the high heating power icon lights up. (high heating
starts after 10 seconds).
-
In operating condition, press the key to shift from low fan power to high fan power.
By pressing the key again, the fan switches back to low power.- When working at low fan speed: the low fan power icon lights up.
- When working at high fan speed: the high fan power icon lights up.
-
In operating mode, you can press the key to make the device oscillate or not.
- Press the Swing key: the device will oscillate, the icon lights up.
- Press the Swing key again: the device will stop oscillating, the icon will be off.
Note:
In warm airflow mode the PTC stops working when the room temperature is higher than the set temperature. The fan stops working after 10 seconds. During that time, the swing function is not available.
-
In operating condition, press the key to set the timer.
-
Go to the timer setting mode, press the key, the LED time icon lights up and blinks every 0.5 seconds. During this time-frame, press the or the key to set the timer (0-12 hours), with each key press the time will be added by 1 hour.
By pressing and holding the or keys, the time can be set faster. -
If no keys are pressed within 5 seconds (except for and ), the LED indicator will show the room temperature.
-
Press the timer key to see the set time. If the value shows a number except for -0-, the timer will start timing (not shown), if the timer reaches value -0-, then the device will turn off at once.
-
If the value shows -0- in timer setting, then this means no time is set, the time icon will be off, the LED display will show the current room temperature.
-
-
a) Press the key, to change the temperature by pressing the or keys.
The temperature range is from 15°C ~ 35°C, the temperature will change by 1°C by every key press.-
By pressing the key again or if no key is pressed within 5 seconds, the temperature that you have set will be effected at once.
-
If no keys are pressed within 5 seconds (except for or ), the LED indicator will show the room temperature. When the temperature is ≤-10°C, the display shows “LO”;
When the temperature is >40°C, the display shows “HI”. -
After switching on the device, it will start measuring the temperature within 10 seconds.
If the ambient temperature is higher than the set temperature then the PTC heating function will turn off; the low/high heating power light will be off, and the fan will switch off after 10 seconds. The swing function will also stop, If you have set it before. All the other icons will not change. If the ambient temperature falls below 1°C of the set temperature, the heating function will switches on again, as well as the fan & the swing function (if set before). The other icons will be on. -
If both timer and room temperature are set, the values are alternately shown on the display (at an interval of 30 seconds).
-
-
Memory last setting: when switching on the device, the last settings will be activated.
-
After the device has been in operation for 1 minute, the display light of the keys will dim.
-
NTC over-heating protection function:
At temperatures higher than 55°C, the device will switch itself off. If the ambient temperature drops below 45°C, the device can be switched on again manually. If the temperature raises above 45°C again, the device will switch off again. After 12 hours of operation with no change in settings, the device will switch itself off.
Cleaning & Maintenance
Unplug the heater before each maintenance and make sure the heater has cooled
down.
If necessary you can use a soft cloth with a neutral cleaning product
dissolved in warm water (below 50°C) to clean the outer side of the fan. Dry
carefully.
To avoid damaging the device, do not use aggressive cleaning agents to clean
the surface of the heater.
To store the heater, place it in a dry and ventilated place.
Remote control
-
Open the battery cover at the back side of remote control to place the battery. (see Picture 1).
-
To place the battery: there is a “security tab” at the bottom of the remote control that you first have to slide to the right and then pull out the battery holder. (see Picture 2).
Insert the battery with the correct polarity. (see Picture 3). -
Push the battery cover back into the remote control.
Specifications
- Model: CA-904G
- For rooms up to: 40m² / 100m³ / 430ft²
- Rated voltage: 220V – 240V, 50Hz
- Rated power: 1000W – Max. 2000W
- Nominal heat output: 2000W
- Minimum heat output: 1000W
- Maximum continuous heat output: 2000W
- Digital temperature control: From 15°C to 35°C
- Fan function Air velocity: up to 5 meter/second
- Turning circle Oscillation: 80°
- Sound level: Silent fan < 35dB(A) Low
- Dimensions: 688 x 210 x 210mm
- Weight: 4,56kg
- Color: Black
- Carried standard: EN/IEC 60035-1,EN/IEC60335-2-30,EN/IEC60335-2-80
- Complies with EU regulations: CE / WEEE / RoHS
Ask your retailer or your municipality for updated information regarding the disposal of the packaging and of the device.
Information requirement for the electric local space heaters
Model identifier: CA-904G
Item| Symbol| Value| Unit| Item| Unit
Heat output| Type of heat input, for electric storage local space
heaters only (select one)
Nominal heat out- put| Pnom| 2.0| kW| Manual heat charge control, with
integrated thermostat| No
Minimum heat output (indicative)| Pmin| 1.0| kW| Manual heat charge control
with room and/or outdoor temperature feedback| No
Maximum continuous heat output| Pmax,c| 2.0| kW| Electronic heat charge
control with room and/or outdoor temperature feedback| No
Auxiliary electricity consumption| —| —| —| Fan assisted heat
output| No
At nominal heat output| elmax| N/A| kW| Type of heat output/room
temperature control (select one)
At minimum heat output| elmin| N/A| kW| Single stage heat output and no room
temperature control| No
In standby mode| elSB| 0.000| kW| Two or more manual stages, no room
temperature control| No
| | | | With mechanic thermostat room temperature control| No
| | | | With electronic room temperature control| Yes
| | | | Electronic room temperature control plus day timer| No
| | | | Electronic room temperature control plus week timer| No
| | | | Other control options (multiple se- lections possible)
| | | | Room temperature control, with presence detection| No
| | | | Room temperature control, with open window detection| No
| | | | With distance control option| No
| | | | With adaptive start control| No
| | | | With operating time limit| No
| | | | With black bulb sensor| No
Contact details| Clean Air Optima International GmbH
Service
Warranty Certificate for the Clean Air Optima® Design Fan Heater CA-904G.
Date of purchase:
Customers name:
Address:
Telephone:
Seller’s name:
Address:
- Please fill in completely this Warranty Certificate. Send it with the invoice and the unit, postage pre-paid and using the original packing box, to your distributor. Make sure to include the appropriate return postage for the package.
- Please enclose a short description of the damage, fault or malfunction, and the circumstances under which these problems arose
The Clean Air Optima® Design Fan Heater CA-904G is subjected to strict
testing procedures before leaving the factory. If within 2 years from the date
of purchase the product does not perform according to the specifications,
because of factory defects, the purchaser is entitled to free repairs or
replacement of parts upon presentation of this warranty (provided that the
malfunction or damage to the device and/or parts occurred under normal
operating conditions). What is covered: All parts defective in material and
workmanship. For how long:
Two years from purchase date. What we will do: Repair or replace any defective
parts.
Other Conditions
The provisions of this warranty are in lieu of any other written warranty
whether express or implied, written or oral, including any warranty of
merchantability or fitness for a particular purpose. The manufacturer’s
maximum liability shall not exceed the actual purchase price paid by you for
the product. In no event shall the manufacturer be liable for special,
incidental, consequential, or indirect damages. This warranty does not cover a
defect that has resulted from improper or unreasonable use or maintenance,
faulty assembly, accident, natural catastrophes, improper packing, or
unauthorized tampering, alteration, or modification as determined solely by
us. This warranty is void if the label bearing the serial numberhas been
removed or defaced.
Thank you for reading!
Share your feedback about the Clean Air Optima®
Design Fan Heater CA-904G on:
www.cleanairoptima.com
For frequently asked questions about the CA-904G go to:
www.cleanairoptima.com
and search for the CA-904G.
Download PDF instruction manual on:
www.cleanairoptima.com/info/manuals
Watch all Clean Air Optima® Product animation video’s on:
www.youtube.com
Customer Support
Clean Air Optima International B.V. | David Ricardostraat 9-7 / 9-9 |
7559 SH Hengelo (ov)
The Netherlands | Phone: +31 (0) 74 – 2670145
Clean Air Optima Germany GmbH | Enschedestraße 14 | 48529 Nordhorn |
Germany
Phone: +49 (0) 5921 879-121
E-mail: info@cleanairoptima.com Internet:
www.cleanairoptima.com