Clean Air Optima CA-703B Dehumidifier User Manual
- June 3, 2024
- Clean Air Optima
Table of Contents
Clean Air Optima CA-703B Dehumidifier
overview
Thank you for purchasing the Clean Air Optima Dehumidifier CA-703B/ CA-
703W.
We wish you many years of healthy indoor air with this efficient and effective
product.
Ensure that all safety precautions are followed when using this electrical
appliance for the proper operation of the device. These instructions describe
the safety precautions to be observed during operation. They are meant to
prevent injuries and to avoid damaging the device.
Description of the appliance
The appliance consists of the following main components:
- Handle
- Air inlet
- Air outlet
- Power interface
- Continuous drainage (water drain, hose connection). Drain hose 1 meter included
- Water tank
- Control panel
- Air outlet
- Right side plate
- Air outlet
Safety warnings
This device may only be used in accordance with this safety instructions. Take the following steps to minimize the risk of personal injury caused by for example electric shocks or fire.
-
Only for indoor use. Do not use or store outdoors.
-
The appliance is not intended to be used by children or persons with reduced physical, sensory or mental capabilities, unless they are supervised by a person responsible
for their safety. -
Use proper voltage: AC 220V – 240V, 50/ 60Hz.
-
Do not use the device when there is visible damage on the electrical cord or on the device itself. Do not repair the device yourself in case of damage. Never pull the device by its cord. If the power cord is damaged, then it must be replaced by an authorized service person to prevent electric shock or fire.
-
Repairs may only performed by authorized service personal. Do not try to repair the device yourself to prevent electric shock or fire.
-
Always switch off the device before disconnecting the plug.
-
Always remove the plug from the cord when the device is not being used.
-
Pull the plug when you do not use the device or when you clean internal or external parts of it.
-
For safety use put the device in a steady, horizontal position. Do not move while using.
-
Do not use the device in rooms where inflammable liquids, gases are stored or close
to heat sources or heat-generating devices. -
Never insert any other object into the body to avoid breakdown.
-
Never cover the air inlet and air outlet grid.
-
Never dissemble or replace the device’s inner parts.
-
Use and store the device not under 5°C or above 50°C.
-
Do not tip the unit to any side when the water tank is full.
-
Do not put heavy objects on the unit.
-
Please avoid places with direct sunlight. There is a risk that the device discolors.
-
Never immerse the unit in water or other liquids.
-
Empty the water tank regularly. In extreme conditions the water tank may be full after a few hours operation.
-
Use, maintain and clean the device as described in this manual.
How to use
Power Press the “POWER” button, the button lights up blue, the device
starts to dehumidify. Press the “POWER” button again, the device turns off.
All indicator lights go out. The fan will stop 10 seconds later.
The evaporator in the dehumidifier may defrost automatically if it is operated
with a room temperature less than 18 °C.
- During the defrosting operation, the dehumidification function and air purification function may intermit.
- Don’t turn of the power or pull out the power plug of the device during the defrosting operation.
Air Purify Indicator Light When the device is working, the air purify function (Ionizer & UV) starts to work when you push this button. The indicator light will light up.
Timer Press the “TIMER” button to set 0-24 hours timing. Press the button
one time, the timer will increase with one hour.
When the device is operating, the timer that is set indicates when the device
switches off.
Temperature Light
This light shows the indoor temperature. This light shows the temperature both
when the device is in operation and in standby mode.
Dehumidify Indicator Light This light shows the indoor humidity. This light shows the humidity level both when the device is in operation and in standby mode.
Water Tank Full Indicator Light
When water tank is full, the device will automatically stop. This light turns
on and lights up red.
Drain the water tank, and return the water tank to the body of the device, the
water tank full indicator light will turn off. The device will work
automatically again.
Water Drainage
Water tank:
The Water tank full indicator light will lights up red when the water tank is
full, a warning will be given.
Take out the water tank(FIG 1), then empty the water inside. Then put the
water tank back into the dehumidifier correctly.
Please do not move the float out of the water tank, or the sensor will not detect the water tank whether it is full or not (FIG 2).
Installation
When the device is working, make sure that the left distance is 20 cm away from walls and furniture, see picture below.
Maintenance
NOTE: TURN OFF THE DEVICE AND UNPLUG IT BEFORE ANY MAINTENANCE OR REPAIR
TO AVOID ELECTRIC SHOCKS.
Cleaning
- Before cleaning the device, unplug the power cord.
- Clean the housing with a soft moisture cloth. Do not use chemical solvent (such as benzene, alcohol, gasoline). The surface may be damaged or even the whole case may be deformed. Do not sprinkle water on the device.
Dehumidifier storage
If the dehumidifier will not be used for an extended period of time:
- Drain the water tank completely and make sure that there is no more water stocked inside.
- Unplug the device and fold up the power supply cord.
- Remove and clean the Pre-Filter, allow it to dry completely and reinstall it.
- Store the dehumidifier in a cool, dry location, away from direct sunlight, extreme temperature and excessive dust.
Troubleshooting
The following is a troubling shooting guide to help you solve any issues that you may have using the Clean Air Optima Dehumidifier CA-703B/ CA-703W.
Problem | Possible Cause | Solution |
---|
Device does not switch on
Inefficiency dehumidification
| The power cord does not connect correctly
The water tank is full or water tank is not
in the correct position
The environment temperature is below 5°C or above 50°C
The air inlet and outlet have a blockage
The setting humidity is higher than environmental humidity
| Connect the power plug and power socket correctly
Drain the water tank and replace the water tank to the correct position
The device can not work in such temperature
Clean the blockage from the air inlet and outlet
Set the humidity at least 5% lower than environmental humidity
Noise
|
The device is installed askew
|
Make sure the machine is installed uprightly
WARNING!
If the above recommended solutions do not work, please contact Clean Air
Optima technical support at the telephone number for your region. Do not
attempt to disassemble, reassemble, or repair the device as this may void the
warranty.
Specifications
- Model CA-703B/ CA-703W
- Rated voltage 220V – 240V, 50/60Hz
- Rated power 65W
- Fan capacity 80 m³ /h
- Capacity 700ml/Day (30°C RH 80%)
- Water tank 2L
- Sound level <38 dB(A)
- Equipped with Ionizer and UV-Lamp
- Dimensions 240 x 140 x 360mm
- Weight 2.16kg
- Colour White
- Complies with EU regulations CE / WEEE / RoHS
Ask your retailer or your municipality for updated information regarding the disposal of the packaging and of the device.
Service
Warranty Certificate for the Clean Air Optima Dehumidifier CA-703B/ CA- 703W
- Date of purchase: ……………………………………………………………………………………………………………………………
- Customers name: …………………………………………………………………………………………………………………………..
- Address: ………………………………………………………………………………………………………………………………………………
- Telephone: ………………………………………………………………………………………………………………………………………….
- Email: ……………………………………………………………………………………………………………………………………………………
- Seller’s name: …………………………………………………………………………………………………………………………………..
- Address: ………………………………………………………………………………………………………………………………………………
1. Please fill in completely this Warranty Certificate. Send it with the
invoice and the unit, postage pre-paid and using the original packing box, to
your distributor. Make sure to include the appropriate return postage for the
package.
2. Please enclose a short description of the damage, fault or malfunction,
and the circumstances under which these problems arose.
The Clean Air Optima Dehumidifier CA-703B/ CA-703W is subjected to strict testing procedures before leaving the factory. If within two years from the date of purchase the product does not perform according to the specifications, because of factory defects, the purchaser is entitled to free repairs or replacement of parts upon presentation of this warranty (provided that the malfunction or damage to the device and/or parts occurred under normal operating conditions). What is covered: All parts defective in material and workmanship. For how long: two years from purchase date. What we will do: Repair or replace any defective parts.
Other Conditions
The provisions of this warranty are in lieu of any other written warranty
whether express
or implied, written or oral, including any warranty of merchantability or
fitness for a particular purpose. The manufacturer’s maximum liability shall
not exceed the actual purchase price paid by you for the product. In no event
shall the manufacturer be liable for special, incidental, consequential, or
indirect damages. This warranty does not cover a defect that has resulted from
improper or unreasonable use or maintenance, faulty assembly, accident,
natural catastrophes, improper packing, or unauthorized tampering, alteration,
or modification
as determined solely by us. This warranty is void if the label bearing the
serial number has been removed or defaced.
Thank you for reading!
- Share your feedback about the Clean Air Optima Dehumidifier CA-703B/ CA-703W on: www.cleanairoptima.com
- For frequently asked questions about the CA-703B/ CA-703W go to: www.cleanairoptima.com and search for the CA-703B/ CA-703W.
- Download PDF instruction manual on: www.cleanairoptima.com/info/manuals
- Watch all Clean Air Optima Product animation video’s on: www.youtube.com
Clean Air Optima International B.V. | David Ricardostraat 9-7 / 9-9 |
7559 SH Hengelo (ov) The Netherlands | Phone: +31 (0) 74 – 2670145
Clean Air Optima Germany GmbH | Enschedestraße 14 | 48529 Nordhorn |
Germany Phone: +49 (0) 5921 879-121
E-mail: info@cleanairoptima.com
Internet: www.cleanairoptima.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>