STELLAR 4-SS-18-LOH Luxury Gas Fireplace User Manual

September 17, 2024
Stellar

STELLAR 4-SS-18-LOH Luxury Gas Fireplace


Product Information

Specifications

  • Model # : 4-SS-18-LOH
  • BTUs : 60,000
  • Exhaust : B-Vent 8
  • CFM’s Make-Up Air : 370
  • RS Series Powervent : RS12

Minimum Framing Dimensions

Model # Width (A) Height (B) Depth (C)
4-SS-18-LOH 55-3/4 [1416] 68-7/8 [1748] 25-1/32 [636]

Fireplace Dimensions

Model #| Finishing Width No Liner (A)| Finishing Width with Liner (AL)| Finishing Height (B)
---|---|---|---
4-SS-18-LOH| 48 [1219]| 44 [1118]| 18 [457]

Product Usage Instructions

  1. Refer to the installation manual for specific dimensions and requirements.
  2. Ensure the minimum framing dimensions are met based on the chosen model.

Operation

  1. Follow the manufacturer’s instructions for lighting the fireplace.
  2. Adjust the settings for desired heat output and flame appearance.

Maintenance

  1. Regularly clean the fireplace and flue to prevent blockages.
  2. Inspect and replace any worn-out components as recommended by the manufacturer.

Safety Precautions

  1. Keep flammable materials away from the fireplace.
  2. Never leave the fireplace unattended while in operation.

Frequently Asked Questions (FAQ)
Q: What should I do if the fireplace does not ignite?
A: Check if the gas supply is connected and there are no blockages in the gas line. If issues persist, contact a professional technician.

ENLIGHT LINEAR OPEN HEARTH SINGLE-SIDED

Luxury Gas Fireplace

FRONT VIEW

  • The dimensions in green are the allowable finishing width and height. Finishing materials must not overlap these dimensions.
  • Designate power vent choice at the time of order
  • It is important to refer to the installation and operating manual PRIOR to installation; verify all measurements and clearances for your particular installation
  • Dimensions are in inches and [millimeters]
  • Use UL approved B-Vent pipe and follow all manufacturer installation guidelines
  • Vent run approved up to 110′ with quality of 11, 90 degree elbows. 1″ clearance to B-Vent must be maintained.

SPECIFICATIONS

Model #| BTUs| Exhaust B-Vent| CFM’s

Make-Up Air

| RS Series Powervent
---|---|---|---|---
4-SS-18-LOH| 60,000| 8| 370| RS12
5-SS-18-LOH| 80,000| 10| 455| RS12
6-SS-18-LOH| 100,000| 10| 535| RS12
7-SS-18-LOH| 120,000| 10| 620| RS12
8-SS-18-LOH| 140,000| 12| 700| RS12
9-SS-18-LOH| 160,000| 12| 785| RS14
10-SS-18-LOH| 180,000| 12| 865| RS14
Model #| BTUs| Exhaust B-Vent| CFM’s

Make-Up Air

| RS Series Powervent
---|---|---|---|---
4-SS-24-LOH| 60,000| 10| 480| RS12
5-SS-24-LOH| 80,000| 10| 590| RS12
6-SS-24-LOH| 100,000| 12| 700| RS14
7-SS-24-LOH| 120,000| 12| 809| RS14
8-SS-24-LOH| 140,000| 12| 920| RS14
9-SS-24-LOH| 160,000| 14| 1,030| RS16
10-SS-24-LOH| 180,000| 14| 1,140| RS16

MINIMUM FRAMING DIMENSIONS

Model #| A

Width

| B

Height

| C

Depth

---|---|---|---
4-SS-18-LOH| 55-3/4 [1416]| 68-7/8 [1748]| 25-1/32 [636]
5-SS-18-LOH| 67-3/4 [1721]| 68-7/8 [1748]| 25-1/32 [636]
6-SS-18-LOH| 79-3/4 [2026]| 70-7/8 [1799]| 25-1/32 [636]
7-SS-18-LOH| 91-3/4 [2330]| 70-7/8 [1799]| 25-1/32 [636]
8-SS-18-LOH| 103-3/4 [2635]| 70-7/8 [1799]| 25-1/32 [636]
9-SS-18-LOH| 115-3/4 [2040]| 70-7/8 [1799]| 25-1/32 [636]
10-SS-18-LOH| 127 3/4 [3245]| 70-7/8 [1799]| 25 1/32 [636]
Model #| A

Width

| B

Height

| C

Depth

---|---|---|---
4-SS-24-LOH| 55-3/4 [1416]| 74-7/8 [1902]| 25-1/32 [636]
5-SS-24-LOH| 67-3/4 [1721]| 74-7/8 [1902]| 25-1/32 [636]
6-SS-24-LOH| 79-3/4 [2026]| 76-7/8 [1953]| 25-1/32 [636]
7-SS-24-LOH| 91-3/4 [2330]| 76-7/8 [1953]| 25-1/32 [636]
8-SS-24-LOH| 103-3/4 [2635]| 76-7/8 [1953]| 25-1/32 [636]
9-SS-24-LOH| 115-3/4 [2040]| 76-7/8 [1953]| 25-1/32 [636]
10-SS-24-LOH| 127 3/4 [3245]| 76-7/8 [1953]| 25-1/32 [636]

FIREPLACE DIMENSIONS

Model #| A

Finishing Width No Liner

| AL

Finishing Width with Liner

| B

Finishing Height

| C

Height to Trim Top

| D

Overall Height

| E

Height to Top of Damper

|

Center of Vent

| G

Firebox Depth

| H

Overall Width

---|---|---|---|---|---|---|---|---|---
4-SS-18-LOH| 48 [1219]| 44 [1118]| 18 [457]| 36 [914]| 48 [1219]| 62-7/8 [1597]| 26-7/8 [683]| 24-1/32 [610]| 53-3/4 [1365]
5-SS-18-LOH| 60 [1524]| 56 [1422]| 18 [457]| 36 [914]| 48 [1219]| 62-7/8 [1597]| 32-7/8 [835]| 24-1/32 [610]| 65-3/4 [1670]
6-SS-18-LOH| 72 [1829]| 68 [1727]| 18 [457]| 36 [914]| 50 [1270]| 64-7/8 [1648]| 38-7/8 [987]| 24-1/32 [610]| 77-3/4 [1975
7-SS-18-LOH| 84 [2134]| 80 [2032]| 18 [457]| 36 [914]| 50 [1270]| 64-7/8 [1648]| 44-7/8 [1140]| 24-1/32 [610]| 89-3/4 [2280]
8-SS-18-LOH| 96 [2438]| 92 [2337]| 18 [457]| 36 [914]| 50 [1270]| 64-7/8 [1648]| 50-7/8 [1292]| 24-1/32 [610]| 101-3/4 [2584]
9-SS-18-LOH| 108 [2743]| 104 [2642]| 18 [457]| 36 [914]| 50 [1270]| 64-7/8 [1648]| 56-7/8 [1445]| 24-1/32 [610]| 113-3/4 [2889]
10-SS-18-LOH| 120 [3048]| 116 [2946]| 18 [457]| 36 [914]| 50 [1270]| 64-7/8 [1648]| 62-7/8 [1597]| 24-1/32 [610]| 125-3/4 [3194]
Model #| A

Finishing Width No Liner

| AL

Finishing Width with Liner

| B

Finishing Height

| C

Height to Trim Top

| D

Overall Height

| E

Height to Top of Damper

| F

Center of Vent

| G

Firebox Depth

| H

Overall Width

---|---|---|---|---|---|---|---|---|---
4-SS-24-LOH| 48 [1219]| 44 [1118]| 24 [610]| 42 [1067]| 54 [1372]| 68-7/8 [1749]| 26-7/8 [683]| 24-1/32 [610]| 53-3/4 [1365]
5-SS-24-LOH| 60 [1524]| 56 [1422]| 24 [610]| 42 [1067]| 54 [1372]| 68-7/8 [1749]| 32-7/8 [835]| 24-1/32 [610]| 65-3/4 [1670]
6-SS-24-LOH| 72 [1829]| 68 [1727]| 24 [610]| 42 [1067]| 56 [1422]| 70-7/8 [1800]| 38-7/8 [987]| 24-1/32 [610]| 77-3/4 [1975
7-SS-24-LOH| 84 [2134]| 80 [2032]| 24 [610]| 42 [1067]| 56 [1422]| 70-7/8 [1800]| 44-7/8 [1140]| 24-1/32 [610]| 89-3/4 [2280]
8-SS-24-LOH| 96 [2438]| 92 [2337]| 24 [610]| 42 [1067]| 56 [1422]| 70-7/8 [1800]| 50-7/8 [1292]| 24-1/32 [610]| 101-3/4 [2584]
9-SS-24-LOH| 108 [2743]| 104 [2642]| 24 [610]| 42 [1067]| 56 [1422]| 70-7/8 [1800]| 56-7/8 [1445]| 24-1/32 [610]| 113-3/4 [2889]
10-SS-24-LOH| 120 [3048]| 116 [2946]| 24 [610]| 42 [1067]| 56 [1422]| 70-7/8 [1800]| 62-7/8 [1597]| 24-1/32 [610]| 125-3/4 [3194]

TV AND MANTEL MOUNTING RECOMMENDATIONS

  • Frame up the fireplace following the manual instructions.
  • We recommend using one larger 2×8 or 2×1 O header rather than double up 2×4’s. This is particularly relevant when installing the models with larger vent pipe that won’t have the proper clearance to combustibles around the pipe.
  • Plan for the TV outlet and cable routing. Stellar recommends above or directly under the header to avoid the fireplace chassis.
  • Do not center on the flue pipe.
  • Decide where to place the TV mount and or mantle. The TV mount can attach through the finishing material into the header (higher TV) or the mount can utilize the metal of the fireplace as a secure backer (lower TV). Avoid the 6 [152] above the fireplace and below the header (red area  in picture). There will be no structure behind the wall to attach to.

The fireplace has metal above the opening that screws are allowed to pierce up to 7/8″ for fastening Purposes. Figure 6B.2 (green area) Refer to manual for dimensions.

NOTE: TV or combustible mantle MUST BE 6 [152] or greater above the fireplace opening. Figure 6B.1

Use lag screws or TV mount recommendations to fasten into the header. Use only screws that are 1-1/2″ longer than the finishing material thickness. The screw cannot touch the pipe behind the header.
Purchase #14 or larger self-drilling screws.
The screws MUST BE NO LONGER THAN 7/8″ PAST THE THICKNESS OF THE FINISHING MATERIAL.
Example, if there is ½” sheetrock over ½” Hardi board, then the max screw length is 1-7/8″.

FINISHING THE WALL

inches (mm

  • A. No combustible framing materials may be within 6 [152] of the top of the fireplace.
  • B. Non-combustible backboard must be used between the viewing area opening and 6 [152] above the fireplace across the full width of the fireplace. 7 [178] is recommended for ease of attachment.
  • C. 6[152] of non-combustible finishing material is required to cover the non-combustible area mentioned in A & B.
  • D. Combustible finishing materials allowed
  • E. Combustible mantel may be placed no closer than 6 [152] from the viewing area opening. There are no restrictions on mantel depth.
  • F. Non-combustible mantel may be placed at the top of the viewing area. There are no restrictions on mantel depth.
  • G. Combustible hearth may be placed below the bottom of the glass viewing area.
  • H. Flat covers will cover the component’s access. Gas and electric inlets are located behind this panel. There are four access panel options all located on the pilot side of the fireplace; front (shown above), side, back and inside on the pilot side. Please take into consideration of which option will be used to access the components for service later during planning.
  • I. Combustible framing and finishing materials are allowed on the face of the fireplace below the viewing area only.

Product information provided is not complete and is subject to change without notice. Product installation must adhere strictly to instructions accompanying product to avoid risk of fire and potential injury.
STL-ENLIGHT-OH-SS-0624

Heat & Glo — A Brand of Hearth & Home Technologies 7571 215th Street West | Lakeville, MN 55044
877-486-9123 | heatnglo.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals