TELTONIKA RUT906 Industrial Grade Router User Guide
- June 16, 2024
- teltonika
Table of Contents
QSG RUT906
Main Page > RUT
Routers >
RUT906 > QSG RUT906
https://wiki.teltonika-networks.com/view/QSG_RUT906
This Wiki page contains the online version of the Quick Start Guide (QSG) for the industrial RUT906 4G (LTE) Router. Here you will find an overview of the various components on the front and back of a RUT906 device, hardware installation instructions, first login information, device specifications, and general safety information. It is highly recommended to acquaint yourself with the Quick Start Guide before using the device. You can also locate a printed version of the Quick Start Guide in the packaging box of your device.
Safety information
Before starting operating the device, please review recommendations and precautions to minimize the possibility of accidents. Safety precautions presented are supplementary and subject to the local safety regulations. When various operations are executed on the device, the user must fully follow the safety instructions and recommendations provided with the device.
General
Radio specifications
RF technologies 2G, 3G, 4G, Wi-Fi, GNSS
Max RF power: 33 dBm@GSM900, 30 dBm@DCS1800, 24 dBm@WCDMA, 23 dBm@LTE, 20
dBm@ WiFi Bundled accessories specifications
Power adapter Input: 0.45A@100-240 VAC, Output: 9 VDC, 1A, 4-pin plug
Mobile antenna: 699~868 / 1850~2690MHz, 50 Ω, VSWR<3, gain 1 dBi,
omnidirectional, SMA male connector
WiFi antenna: 2400~2500 MHz, 50Ω, VSWR<2.5, gain 3dBi, omnidirectional,
RP-SMA male connector
GNSS antenna: 1575.42~1602 MHz, 50Ω, 3-5 VDC, VSWR<2, gain 28dB (typ.),
RHCP polarization, SMA male connector
Order code dependant.
Higher gain antenna can be connected to compensate for cable attenuation
when a cable is used. The user is responsible for the compliance with the
legal regulations.
RUT906 router must be used in compliance with any and all applicable national
and international laws and with any special restrictions regulating the
utilization of the communication module in prescribed applications and
environments.
CE Declaration of Conformity
Detailed compliance information is available at the following internet
address:
wiki.teltonikanetworks.com/view/Certificates.
This sign means that is necessary to read the User’s Manual before you start
using the device.
This sign on the package means that all used electronic and electric equipment
should not be mixed with general household waste.
Hereby, TELTONIKA NETWORKS declares that this RUT906 is in compliance with the
essential requirements and other relevant provisions of Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the
following internet address: https://wiki.teltonika-
networks.com/view/RUT906_CE/RED.
Hereby, TELTONIKA NETWORKS declares that the radio equipment type RUT906 is in
compliance with Radio Equipment Regulations 2017. The full text of the UK
declaration of conformity is available at the following internet address:
https://wiki.teltonika-networks.com/view/RUT906_UKCA.
RF exposure
This device meets the official requirements for exposure to radio waves. This
device is designed and manufactured not to exceed the emission limits for
exposure to radio frequency (RF) energy set by authorized agencies. The device
must be used with a minimum separation of 20 cm from a person’s body to ensure
compliance with RF exposure guidelines. Failure to observe these instructions
could result in your RF exposure exceeding the applicable limits.
External antennas used with RUT906 must be installed to provide a distance of
at least 20 cm from any people and must not be co-located or operated in
conjunction with any other antenna or transmitter.
Any external antenna gain must meet RF exposure and maximum radiated output
power limits of the applicable rule section.
Maximum transmission power
GSM900 | 33 dBm |
---|---|
DCS1800 | 30 dBm |
WCDMA | 24 dBm |
LTE | 23 dBm |
WiFi | 20 dBm |
Operating conditions
- Operating temperature: -40° to +40° Celsius
- Humidity should be in the range of 10% to 90% (non-condensing). Only use the device in dry environments.
- Out of direct sunlight
- Away from heat source, corrosive substances, salts, and flammable gases
Attention: operation outside the permissible range can considerably shorten
the service life of the device.
Faulty and damaged products
Electrical safety
- Only use approved accessories.
- Do not connect with incompatible products or accessories.
- It is recommended to ground devices with grounding terminals before connecting them to power. Failure to ground appropriately might result in a shock hazard. The cross-sectional area of the protective grounding conductor should be at least 1mm2.
Product handling
- You alone are responsible for how you use your device and any consequences related to its use.
- Use of your device is subject to safety measures designed to protect users and their environment.
- Always treat your device and its accessories with care and keep it in a clean and dust-free place.
- Do not expose your device or its accessories to open flames, lit tobacco products, liquid, moisture, or high humidity.
- Do not drop, throw or try to bend your device or its accessories.
- Do not use harsh chemicals, cleaning solvents, or aerosols to clean the device or its accessories.
- Do not paint your device or its accessories.
- Do not attempt to disassemble your device (exemptions for devices that require disassembly for SIM insertion) or its accessories: it does not contain any user-serviceable parts. For safety reasons, the equipment should be opened only by qualified personnel.
- Make sure to use ESD personal protective equipment while the equipment is serviced.
- Do not use your device in an enclosed environment where heat dissipation is poor.
- Prolonged use in such space may cause excessive heat and raise ambient temperature, which will lead to the automatic shutdown of your device or the disconnection of the mobile network connection for your safety. To use your device again after such a shutdown, cool it in a wellventilated place before turning it on.
- Please check all national laws and local regulations for the disposal of electronic products.
- Do not operate the device where ventilation is restricted.
- Do not use or install this product near water to avoid fire or shock hazards.
- Avoid exposing the equipment to rain or damp areas.
- Arrange power and Ethernet cables so that they are not likely to be stepped on or have items placed on them.
- Ensure that the voltage and the rated current of the power source match the device’s requirements.
- Do not connect the device to an inappropriate power source.
- During a thunderstorm, no operations should be carried out on the device and cables.
- The unit must be powered off where blasting is in progress and explosive atmospheres are present or near medical life support equipment.
- Do not leave your device and its accessories within reach of small children or allow them to play with it. They could hurt themselves or others and could accidentally damage the device.
- Your device contains small parts with sharp edges that may cause an injury choking hazard.
- Like any wireless device, this device operates using radio signals, which cannot guarantee connection in all conditions. Therefore, you must never rely solely on any wireless device for emergency communications or otherwise use the device in situations where the interruption of data connectivity could lead to death, personal injury, property damage, data, or other loss.
- The device may become warm during regular use.
Front view
Back view
Connectors
POWER SOCKET PINOUT
Video Quick Start Guide
Need some help setting up your new Teltonika Networks RUT906 – E-mark 4G
industrial cellular router? Watch our quick start guide video and follow the
step by step instructions to easily set up your new router for operation.
Hardware installation
Configure your computer (Windows)
- Ensure the Wireless networkconnection is Enabled. Go to Start — Control Panel — Network and Internet — Network and Sharing Center. Click on the Change adapter settings in the left panel, then right-click onWireless Network Adapter, and select Enable.
- Check if IP and DNS are obtained automatically. Right-click on Wireless Network Adapter and select Properties. Then select Internet Protocol Version 4 and click Properties.
- If not selected, check to obtain an IP address and obtain DNS server address automatically. Click OK.
- Connect to a wireless network by right-clicking on Wireless Network Adapter and selecting Connect.
- Choose the wireless network RUT906 **** from the list and click Connect. Enter the WiFi password located on the device’s label.
Login to device
- To enter the router’s Web interface (WebUI), type http://192.168.1.1 into the URL field of your Internet browser.
- When prompted for authentication enter the username admin and enter the password located on the device information label/engraving.
- After logging in, you must set a new password for security reasons. You will not be able to interact with the router’s WebUI until the default password is changed. The new password must consist of a minimum of 8 characters. Requirements: one uppercase letter, one lowercase letter, and one digit.
- Next, the Configuration Wizard will start to help you set up some of the router’s main operational parameters.
- Finally, let’s verify the Mobile signal strength. Go to the Status — Network page and pay attention to the Signal Strength indication.
To achieve the best signal conditions and maximize cellular performance, try adjusting the antennas or changing the location of your device. You can find information on signal strength recommendations here.
SIM card recommendations
Before installing the SIM cards, please apply a thin layer of dielectric
grease to the SIM card contacts for devices used in environments with high-
vibration levels. This will help avoid SIM cards losing touch with the SIM
slot and prevent unexpected failures.
Industrial Grade SIM cards are recommended for devices requiring a long
lifespan used in environments with extreme temperatures, corrosive or extra
humid climates, or hard-toreach locations.
References
- Certificates - Teltonika Networks Wiki
- Teltonika Networks Wiki
- QSG RUT906 - Teltonika Networks Wiki
- RUT Routers - Teltonika Networks Wiki
- RUT906 - Teltonika Networks Wiki
- RUT906 CE/RED - Teltonika Networks Wiki
- RUT906 UKCA - Teltonika Networks Wiki
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>