GUANGDONG K1 Plus Smart Lock User Manual
- June 15, 2024
- Guangdong
Table of Contents
GUANGDONG K1 Plus Smart Lock
Introduction
Thanks for choosing our K1 Plus smart lock. Please check the user manual carefully before operation and installation.
Component
-
Front Handle
-
Back Handle
Packing List
No. | Item | Quantity |
---|---|---|
1 | Front Handle | 1 |
2 | Back Handle | 1 |
3 | Accessories | 1 |
4 | User Manual | 1 |
5 | Template | 1 |
6 | Mortise Lock | 1 |
7 | Mechanical Key | 2 |
Instructions
Emergency power supply and reboot system
If in low power or the system died, please use Type-C wire to connect to portable power bank and insert in emergency power supply interface. Then you can open properly.
Restore default settings
This procedure will delete all user codes associated with the lock. Long-press the setting key by using a needle when the power is on. After hearing the voice prompt, please continue to press the key until restore the factory settings.
Key
Rotate 90°, then press the handle to open the door.
Adjust mortise lock length , if necessary
If the backset of your door was 60mm, you do not need to do anything.If the
backset of your door was 70mm, you need to adjust your mortise lock. Just push
the button to the 70mm space.
Key Function
Function key : turn on/off Passway mode
Setting Key : Short click:Enter Setting mode
Long press : Restore default settings
Front Handle
keyboard operation instructions
Back handle
Installation Steps
-
Drill a hole on the door as the template required.
-
lnsert the mortise lock into the door.
Then use 2 pcs of self tapping screws to fix it.
-
Install 2pcs threaded sleeves to the front handle.
-
Thread the front handle wire through the square rod hole, then install the square rod.
-
Open the plate from the tail of back handle (as shown).
-
Thread the front handle wire and square rod through the mortise lock.
-
Thread the wire from the front handle through the hole in the back handle.
-
Insert the front handle wire into the corresponding sockets on back handle.
-
At first, fasten the back handle and front handle with one screw (as shown).
-
Then press the back handle and fasten them with one screw.
-
At last put into 4*1. 5v AAA alkaline batteries and cover them.
-
Install strike plate and strike box to the door frame, then fasten them with 2 pcs self tapping screws.
Operating Process
Demo mode
After installation, the current state is demo mode, any fingerprint or
password can open the door. You can try the system under the voice prompt.
Registered administrator
The first fingerprint or password you registered is the administrator.
Subsequent registration and deletions require administrator authorization.
Note : After successfully adding the administrator, the Initial password “123456” will automatically lose effectiveness.
Registered user
Note:
- Fingerprint capacity is 20, Password capacity is 20.
- Cannot register duplicate fingerprints or passwords.
Delete user
Note : Unable to delete administrator information, number 01 is the
administrator.
Passway mode
Any user can open the door in passway mode.
Note : You can set it on the App.Turn on the “Tuya” App and select Smart Lock K1 Plus.Click “Settings” and turn on/off the “Auto Lock” button.
Restore default settings
This procedure will delete all user codes associated with the lock and the
system will revert to demo mode.
Note : If released in the second step,the door lock reset will be canceled.
Bluetooth function
Please download the “Tuya ”App from the App stores before using this function.
Note : If you have not registered administrator before binding the “Tuya
”App, please register the administrator from the “Tuya ”App. The first
fingerprint or password you registered is the administrator.
Before binding Tuya App, you can directly use the smart lock to add and delete
users as well as passwords. However, after binding Tuya App, operations for
adding and deleting users and passwords can only be performed through the Tuya
app.
Attention
- Operating the lock requires special environment. Please use it in specified field technology ranges. The long time overload and exceed usage will reduce the life length. Please keep your finger clear and prevent this product from long time in sunshine when use it.
- After a period of time, there will be dirt on the fingerprint reader and may affect normal use. Please use soft cotton to clear the fingerprint reader. The fingerprint head and screen are the fragile glass materials, please do not hit or touch by hard object.
- If the lock voltage is insufficient when open door, the lock will prompt with alarm sound and red light flash. Please change the battery timely. Please do not use with mixed old and new battery.
- The lock handle is the necessary auxiliary tool to open door. Please do not hang any heavy object on the handle.
- Please choose professional worker to install the door lock and follow with our installation standard. Please do not disassemble this lock personally and take care of relevant label to avoid unnecessary trouble for warranty.
- Please register administrator fingerprint and keep the mechanical keys after lock is installed well. When the fingerprint and password and other methods can’t open door, you can open door by mechanical key.
Tuya App Operation Instructions
Unlock
- Turn on the “Tuya” App and select Smart Lock K1 Plus
- Turn right the key button to unlock
Temporary code settings
- Select “Temporary code”
- Choose the code type and enter a 6-10 digit password
- Setting the effective time and expiration time
- Click “Save” successful
Member Management settings
- Select “Member Management”
- Choose the family member
- Click the “+Add” to registered user fingerprint or code
- According to the prompt, finish registration
Turn on/off mute mode
There is no voice prompt when opening the door in mute mode (retain light prompt). Other operations still have voice prompts.
- Select “Settings”
- Turn on/off the “Mute Control” button
- Succeeded
Language settings
- Select “Settings”
- Click “Language settings”, choose English or Chinese, Press “OK” to confirm
- Succeeded
FCC ID:2AW72-K1PLUS
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions : (1) this device may not cause harmful
interference, and (2) this device must accept any interference received.
including interference that may cause undesired operation.
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance 20cm between the radiator and your body.
FCC WARNING
Warning : Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
FCC STATEMENT
NOTE : This equipment has been tested and found to comply with the limits
for a Class B digital device. pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation.
This equipment generates uses and can radiate radio frequency energy and, if
not installed and used in accordance with the instructions, may cause harmful
interference to radio communications.
However, there is no guarantee that interference will not occur in a
particular installation, If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Read User Manual Online (PDF format)