genaray LF-RGB-65 RGB LED Fresnel with 6.5 Inch Lens Instruction Manual

June 12, 2024
genaray

genaray LF-RGB-65 RGB LED Fresnel with 6.5 Inch Lens Instruction Manual
genaray LF-RGB-65 RGB LED Fresnel with 6.5 Inch Lens

THANK YOU FOR CHOOSING GENARAY

The Genaray LF-RGB-65 boasts a large 6.5-inch Fresnel lens to focus its spot- to-flood beam from 25° to 60° for ideal key, fill, and accent light applications. With a peak intensity of nearly 20,000 lux, this light is perfect for photos, videos, theaters, and houses of worship. It offers a full- spectrum RGB light and a color temperature range of 2800 to 6500 K. Accurate color temperature and green/magenta shift adjustment allows this fixture to conform to natural or artificial ambient lighting conditions as well as other light fixtures on the set. Multiple operating modes help you get the most out of this versatile light, and programmed effects add realistic and dramatic looks to any scene.

The LF-RGB-65 runs on AC power and is operated by its simple control panel. It can also be operated via DMX 512 protocols, and DMX input and output ports allow for daisychaining and using this light with a DMX universe.

PRECAUTIONS

  • Please read and follow these instructions, and keep this manual in a safe place.
  • Keep this unit away from water and any flammable gases or liquids.
  • Make sure the unit is powered off when plugging it into a power source.
  • Use only the correct, recommended voltage.
  • Do not attempt to disassemble or repair the equipment—doing so will void the warranty, and Genaray will not be responsible for any damage.
  • Handle the unit with care.
  • Do not stare directly at the lights when they are powered on. · Always use a steel safety cable (not included) when suspending a light fixture or other assembly.
  • Clean the unit with only a soft, dry cloth.
  • Images are for illustrative purposes only

OVERVIEW

Product Overawe
Product Overawe

CONTENTS INCLUDE

  • RGB LED Fresnel
  • 4-way Barndoors
  • Yoke
  • Brake plate (×2)
  • Washers (×2)
  • Ratchet handles (×2)
  • AC power cord
  • QuickStart guide

ATTACHING THE YOKE

Use the brake plates, washers, and locking handles to attach the yoke to the LF-RBG-65
ATTACHING THE YOKE

MOUNTING THE LF-RGB-65

Mount the LF-RBG-65 on any heavy-duty light stand with a 5/8-inch baby pin, and turn the locking knob until secure.

Important!
When suspending the fixture from a ceiling mount or boom arm, using a safety cable is recommended
MOUNTING

ATTACHING THE BARN DOORS

Lift the barndoor clip and turn it to the side. Then slide the barndoors into the outer slots. Raise the barndoor clip and turn it so the slot fits onto the barndoors, and press it down to lock the barndoors in place.

Once the barndoors are attached, rotate them to the desired orientation.

POWERING THE LF-RGB-65

The LF-RGB-65 runs only on AC power. Connect the power cable to the power input socket and a power source, such as a wall outlet.

The LF-RGB-65 is a multivoltage fixture capable of running on 110–240 V, 50/60 Hz. The included cable has a 120 V, 50 Hz (North American) plug. To use this fixture with other voltages, you must use a plug adapter (sold separately).

FOCUSING THE FRESNEL

Turn the Focusing knob on the back panel of the light to lengthen or shorten the focal length between the LED display and the lens. The light has a focusing range of 25° to 65°.

USER INTERFACE

  • CCT/RGB Selector: Press repeatedly to select CCT or RGB mode.
  • Mode button: Press repeatedly to cycle through the RGB and CCT operating modes.
  • Confirm button: Press the Confirm button to select whatever operating mode or setting is blinking.
  • Color knob: Turn the Color knob to select the setting to adjust. When the setting blinks, adjust the value with the Brightness knob.
  • Brightness knob: When the setting blinks, change the value with the Dimmer knob. Press the Confirm button to accept the new value.

Note
If the Confirm button is not pressed, the light reverts to the previous operating mode after approximately 10 seconds.

SELECTING AN OPERATING MODE

Pressing the RGB/CCT button accesses two sets of operating modes. When CCT is selected, press the mode selector repeatedly to cycle through CCT Mode, CCT Hue Shift, CCT Flash, and DMX Address.

When RGB is selected, press the mode selector repeatedly to cycle through HSI Mode, RGB Mode, GEL Mode, SFX Mode, and DMX Address.

As you cycle though the modes, each mode will blink when it appears onscreen. Press the Confirm button to activate that operating mode.

CCT OPERATING MODES

CCT MODE
Color knob: Adjusts the color temperature from 2800 to 6500 K in 100 K increments.
Brightness knob: Adjusts the intensity from 0% to 100% in 5% increments.
CCT MODE

CCT HUE SHIFT MODE

Similar to CCT Mode with an additional Green/Magenta tint function. The Green/Magenta function lets you match the light’s color to an existing light source by adjusting the green/magenta saturation level. This is useful when shooting under fluorescent lights.

Color knob: Select Intensity, CCT (color temperature), or G/M tint.
Brightness knob: Adjusts intensity from 0% to 100%. Adjusts CCT from 2800 to 6500 K. Adjusts Tint from −1.0 to +1.0 (full green to full magenta) in 0.1 increments.
CCT HUE SHIFT MODE

Note:
The color temperature that’s set in CCT mode will be the color temperature in CCT Shift mode. Changing the color temperature in CCT Shift mode will change the color temperature in CCT mode.

CCT FLASH
Creates a strobing effect with the color temperature and brightness set in CCT mode.

Color knob: No function.
Brightness knob: Adjust the blinking frequency from 1 (slowest) to 9 (fastest).

Press Confirm to set the new frequency.
CCT FLASH

RGB OPERATING MODES

HSI MODE

HSI (Hue, Saturation, Intensity) mode lets you scroll through the entire color wheel and adjust the saturation and intensity level.

Color knob: Select Hue, Saturation, or Intensity.
Brightness knob: Adjust the values, and press Confirm to accept the settings.
HSI MODE

RGB MODE
Select a color by manually setting the RGB levels.

Color knob: Select the R, G, and B values.
Brightness knob: Adjust the R, G, and B value from 0 to 255.

Press Confirm to set the new values. The light will display the new color
RGB MODE

GEL MODE
GEL mode lets you set a white balance color temperature, and modify it with one of 22 preset gels.

Color knob: Selects a gel from 1 to 22. Select a gel, and press Confirm.
Brightness knob: Adjusts the intensity from 20% to 100%.
GEL MODE

List of Gels

  1. Medium Rose
  2. Lale Brilliant
  3. Pale Purple
  4. Medium Golden
  5. Light Golden
  6. Pink
  7. Medium Green
  8. Bright Green
  9. Pea Green
  10. Light Green
  11. Apple Green
  12. Pale Green
  13. Green Blue
  14. Westlake Blue
  15. Lightsky Blue
  16. Sky Blue
  17. Purple Blue
  18. Grey Blue
  19. Blue
  20. Lemon
  21. Pale Straw
  22. Fluorescent

SFX MODE
Twelve programmed effects are built into the LF-RGB-65.

Color knob: Scrolls through the fourteen effects. Press Confirm to select the desired effect. Once it’s selected, the effect will begin to play.
Brightness knob: Adjusts the intensity from 20% to 100%.
SFX MODE

List of Effects

  1. Candle: Simulates the warm light of a flickering candle with varying yellow and orange hues.
  2. Police 1: Simulates the flashing lights of an emergency vehicle with alternating rapid flashes of red and blue light.
  3. Police 2: Alternating double flashes of red and blue with a short pause between cycles.
  4. Police 3: Alternating triple flashes of red and blue with a short pause between cycles.
  5. Lighting 1: Two short white bursts repeated at 5-second intervals.
  6. Lightning 2 : Short and long white bursts repeated at 4-second intervals.
  7. Watch TV: Simulates the flickering glow from a television.
  8. Scene Yellow: Loops through the yellow RGB settings.
  9. Scene Blue: Loops through the blue RGB settings.
  10. Scene Green: Loops through the green RGB settings.
  11. Scene Pink: Loops through the pink RGB settings.
  12. SOS: Repeated short and long white bursts in an SOS (– – – — — — – – –) pattern.
  13. Cycle 1: Cycles repeatedly through the hues in Scene Blue and Scene Green.
  14. Cycle 2: Cycles repeatedly through the hues in Scene Yellow and Scene Pink.
  15. Flash: Rapid flashes of the hue that’s set in RGB mode.

SETTING THE DMX ADDRESS
The DMX address can be set in either CCT or RGB operating modes.

Color knob: Selects each of the three digits.
Brightness knob: Adjusts each digit.

Once all three digits are set, press Confirm to set the DMX address.

DMX Address
DMX Address

SPECIFICATIONS

LIGHT FIXTURE

  • LED Chip Type: COB
  • Beam Angle: 25° to 65°
  • Color Temperature: 2800 to 6500 K
  • Color Accuracy Standard: CRI: 97
  • Cooling System: Internal fan
  • Dimming: Yes, 0% to 100%
  • Display: LCD
  • Housing Material: Aluminum
  • Light Intensity @ 1 m (5600 K): 17,900 lx (focused) 11,200 lx (wide)
  • Expected Lamp Life : 50,000 hr.
  • Dimensions (H × W × D) without barndoors :12.2 × 16.1 × 8.7 in. (31 × 41 × 22 cm)
  • Weight (with yoke and barndoors): 20.7 lb. (9.39 kg)

CONNECTORS

  • Power Input Connector: 3-prong male
  • DMX : 3-prong male 3-prong female

MOUNTING

  • Fixture Mount: 5/8 in. female

YOKE

  • Yoke Material: Aluminum
  • Yoke Type: Yoke/Bracket
  • Tilt: 180°

REMOTE OPERATION

  • Remote Control Type: DMX
  • Number of DMX Channels: 512

POWER

  • AC Input Power: 110 to 240 V, 50/60 Hz
  • Power Source: External
  • Max Power Consumption: 200 W

ONE-YEAR LIMITED WARRANTY

This Genaray product is warranted to the original purchaser to be free from defects in materials and workmanship under normal consumer use for a period of one (1) year from the original purchase date or thirty (30) days after replacement, whichever occurs later. Genaray’s responsibility with respect to this limited warranty shall be limited solely to repair or replacement, at Genaray’s discretion, of any product that fails during normal use of this product in its intended manner and in its intended environment. Inoperability of the product or part(s) shall be determined by Genaray. If the product has been discontinued, Genaray reserves the right to replace it with a model of equivalent quality and function.

This warranty does not cover damage or defect caused by misuse, neglect, accident, alteration, abuse, improper installation or maintenance. EXCEPT AS PROVIDED HEREIN,GENARAY MAKES NEITHER ANY EXPRESS WARRANTIES NOR ANY IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS

FOR A PARTICULAR PURPOSE. This warranty provides you with specific legal rights, and you may also have additional rights that vary from state to state.

To obtain warranty coverage, contact the Genaray Customer Service Department to obtain a return merchandise authorization (“RMA”) number, and return the defective product to Genaray along with the RMA number and proof of purchase. Shipment of the defective product is at the purchaser’s own risk and expense.

For more information, or to arrange service, visit www.genaray.com or contact us at [email protected].

© 2023 Genaray. All Rights Reserved.

genaray Logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals