IMI Hydronic Engineering TV4-14 Transfero Connect Instruction Manual

June 4, 2024
IMI Hydronic Engineering

IMI Logo A

WTMOIN0005
02.2022

Transfero Connect

TV 4 – 14

INSTALL

IMI Hydronic Engineering TV4-14 Transfero Connect A1

IMI Hydronic Engineering TV4-14 Transfero Connect A3

IMI Hydronic Engineering TV4-14 Transfero Connect A5

www.imi-hydronic.com

IMI Hydronic Engineering TV4-14 Transfero Connect B2A

IMI Hydronic Engineering TV4-14 Transfero Connect B2B IMI Hydronic Engineering TV4-14 Transfero Connect
B2C

TU Art.Nr. 7463011

IMI Hydronic Engineering TV4-14 Transfero Connect C1A

TG Art.Nr. 7463013

IMI Hydronic Engineering TV4-14 Transfero Connect C1B

TU-E Art.Nr. 7463012

TG-E Art.Nr. 7463014

IMI Hydronic Engineering TV4-14 Transfero Connect C2

IMI Hydronic Engineering TV4-14 Transfero Connect C3

IMI Hydronic Engineering TV4-14 Transfero Connect C4

Transfero TU                    Transfero TUE

  IMI Hydronic Engineering TV4-14 Transfero Connect
C5B

Transfero TG             Transfero TG-E

TV.1 E (C) (H)

Optional IMI Hydronic Engineering TV4-14 Transfero Connect
D2 IMI Hydronic Engineering TV4-14 Transfero
Connect D3

TV.1_E, TV.1_EC

| Sin1| Sin2| Sout| Swm
---|---|---|---|---
Ts min| °C|

0

| |

0

|

0

Ts max

|

°C

| 70| | 70|

65

|

TV_4

| TV_6| TV_8| TV_10|

TV_14

---|---|---|---|---|---
dpu min| bar|

1

| 1,5| 2| 3,5|

5,5

dpu max| bar|

2,5

| 3,5| 4,5| 6,5|

10

TV.1_EH, TV.1_EHC|

Sin1

| Sin2| Sout|

Swm

---|---|---|---|---
Ts min| °C|

0

| 5| 0|

0

Ts max| °C|

90

| 70| 90|

65

TV.2 E (C) (H)

Optional

IMI Hydronic Engineering TV4-14 Transfero Connect D4 IMI Hydronic Engineering TV4-14 Transfero Connect
D5

|

TV_4

| TV_6| TV_8| TV_10|

TV_14

---|---|---|---|---|---
dpu min| bar|

1

| 1,5| 2| 3,5|

5,5

dpu max| bar|

2,5

| 3,5| 4,5| 6,5|

10

TV.2_EH, TV.2_EHC|

Sin1

| Sin2| Sout|

Swm

---|---|---|---|---
Ts min| °C|

0

| 5| 0|

0

Ts max| °C|

90

| 70| 90|

65

tr ≤ 70°C

TV.1 E + Pleno BA4 R

IMI Hydronic Engineering TV4-14 Transfero Connect E2

tr ≤ 70°C

TV.1 E + Pleno AB5 R + Pleno Refill

IMI Hydronic Engineering TV4-14 Transfero Connect E3

70°C < tr ≤ 90°C

TV.1 EH / TV.2EH + Pleno P BA4 R + Pleno Refill

IMI Hydronic Engineering TV4-14 Transfero Connect E4

tr ≤ 70°C

TV.1 EH / TV.2EH + Pleno AB5 R + Pleno Refill

IMI Hydronic Engineering TV4-14 Transfero Connect E5

5°C ≤ tr ≤ 70°C

TV.1 EC + Pleno AB4 R + Pleno Refill

IMI Hydronic Engineering TV4-14 Transfero Connect F2

0°C ≤ tr ≤ 5°C

TV.2 EHC + Pleno BA4 R

IMI Hydronic Engineering TV4-14 Transfero Connect F3

5°C ≤ tr ≤ 70°C
TV.2 EHC + Pleno AB5 R + Pleno Refill

IMI Hydronic Engineering TV4-14 Transfero Connect F4

DNe

IMI Hydronic Engineering TV4-14 Transfero Connect F5 IMI Hydronic Engineering TV4-14 Transfero Connect
G1 IMI Hydronic Engineering TV4-14 Transfero
Connect G2

max. qwm > 1300 l/h
(Refill 16000/36000/48000,
Refill Demin 13500/18000)

max. qwm < 1300 l/h
(Refill 6000/12000,
Refill Demin 2000/4000)

1 x 230V
T.1: 10A / 3 x 1,0 mm²
T.2: 16A / 3 x 1,5 mm²

       #1-5       IMI Hydronic Engineering TV4-14 Transfero Connect
G4

IMI Hydronic Engineering TV4-14 Transfero Connect H1 IMI Hydronic Engineering TV4-14 Transfero Connect
H2

IMI Hydronic Engineering TV4-14 Transfero Connect H3 IMI Hydronic Engineering TV4-14 Transfero Connect
H4

IMI Hydronic Engineering TV4-14 Transfero Connect H5 IMI Hydronic Engineering TV4-14 Transfero Connect
H6

We reserve the right to introduce technical alterations without prior notice.

www.imi-hydronic.com

Documents / Resources

| IMI Hydronic Engineering TV4-14 Transfero Connect [pdf] Instruction Manual
TV4-14, Transfero Connect, TV4-14 Transfero Connect, Connect
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

IMI Hydronic Engineering User Manuals