Laserliner AirBreeze 120 Air Purifier 30 m² Black Instruction Manual
- June 15, 2024
- Laserliner
Table of Contents
- AirBreeze 120 Air Purifier 30 m² Black
- Intended use
- General safety instructions
- Safety instructions
- Overview
- Correct setup of the air purifier
- Operation
- Functions
- Changing the filter
- Aromatherapy function
- Information on maintenance and care
- Energy use and environmental considerations
- Technical data
- EU and UK directives and disposal
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
AirBreeze
AirBreeze 120 Air Purifier 30 m² Black
Completely read through the operating instructions, the ,,Warranty and Additional Information” booklet as well as the latest information under the internet link at the end of these instructions. Follow the instructions they contain. These documents must be kept in a safe place and passed on together with the device.
Intended use
This air purifier is suitable for filtering category PM 2.5 fine dust particles and provides effective improvement in indoor air quality. The user is provided with information on the indoor air quality by a 4-stage colour display. The device reduces pollen levels, filters fine animal hairs, removes unpleasant smells and features an aromatherapy function.
General safety instructions
- The device is intended only for purification of the ambient air in closed rooms
- The device is suitable for commercial and domestic use.
- The device must only be used in accordance with its intended purpose and within the scope of the specifications.
- Not suitable for use in environments that present a risk of explosion or for medical diagnostic measurements.
- This device and its accessories are not toys.
- Modifications or changes to the device are not permitted, this will otherwise invalidate the approval and safety specifications.
- Incorrect assembly can result in fire or the risk of a fatal electric shock.
- The structure of the device must not be modified in any way.
- Do not insert objects into the openings on the device and do not place objects on the device.
- Do not expose the device and its plug to any mechanical stress, moisture, extreme temperatures, or significant vibration.
- Avoid moisture and sand, clean thoroughly after use.
- Do not use in the vicinity of an open fire or in air containing high levels of grease.
- The device must not be used if one or more of its functions fail or if the housing or connections are damaged.
- This device is to be used in enclosed spaces only; do not expose to moisture or rain as this may result in electric shock.
- Protect the device from contamination and damage and store in a dry place.
- Do not use the device in environments containing explosive gases or vapor.
- Do not set up the tripod on unsecured roads: risk of accident.
- Ensure the connecting cable is placed away from high traffic areas to avoid trip hazards.
- Risk of falls! Ensure the device is securely located.
- A fall can lead to injuries, damage to the device, and overheating leading to a fire risk.
- If the product is placed on an item of furniture, this must be sufficiently large and stable to prevent inadvertent tipping or it being knocked or pulled over.
- Ensure connecting cables are placed such that they avoid being trodden on, clamped or put under tension.
- Do not lay the mains cable under carpets, floor coverings, or furniture/other devices. Fire risk!
- Take particular care to protect the plug connections to the device and sockets.
- The device is intended for use on a secure, flat surface.
- Risk of overheating!
- Do not block or cover any of the ventilation openings on the device during operation.
- Do not use in the vicinity of open flames or other heat sources (heating systems, ovens, amplifiers, etc.).
- Overheating has a detrimental effect on the service life and can represent a risk of fire.
- Always disconnect the device from the power supply during thunder storms or if the device is left unused for an extended period of time.
- The mains plug must always be easily accessible.
- When removing a plug from a socket, always pull the plug and never the cable in order to avoid electric shocks and the risk of fire due to damage.
- Clean the mains plug at regular intervals.
- Ensure the mains plug is always fully inserted into the socket.
- Deposits and connections can lead to short circuits, overheating, and the risk of fire.
- Ensure your hands are dry when handling the mains cable and plug.
- Disconnect the device from the mains immediately if any of the following circumstances occur:
- a switch, the display or a function is no longer working correctly.
- an RCD, circuit breaker or a fuse has blown.
- the mains cable or plug has overheated.
- the device is making unusual noises or vibrations or emitting unusual smells.
- any other unusual responses or defects.
- Disconnect from the mains before changing the filter or cleaning the device.
- Do not operate the air purifier without a filter.
- The filters must be removed from their packaging before fitting.
- The device indicates when the filter needs to be changed but can still be operated normally with this display.
- Typical incorrect uses to be avoided by users:
- Use:
- in wet areas (such as bathrooms, sanitary areas)
- as storage, particularly placement of containers filled with liquids.
- in the immediate vicinity of wet objects
- outside the permitted environmental conditions
- outside – in explosive or flammable atmospheres
- Covering the ventilation openings.
- Inserting conductive objects into the ventilation slots.
- Tampering with or bypassing safety equipment.
- If safety instructions are ignored, this can result in electric shocks, burns and/or severe injury.
Observe the safety instructions. Ignoring the safety instructions puts people, the environment and the product at risk.
Safety instructions
Dealing with electromagnetic disturbances
- The device complies with the provisions and limit values for safety and electromagnetic compatibility in accordance with the Low Voltage Directive (LVD) 2014/35/EU and the Electromagnetic Compatibility (EMC) Directive 2014/30/EU.
- Umarex GmbH & Co KG hereby declares that the electronic device AirBreeze 120 complies with the requirements and other conditions of the European Low Voltage Directive 2014/35/EU (LVD) and the EMC Directive 2014/30/EU. The complete text of the EC declaration of conformity is available at the following internet address: https://laserliner.com
- Local operating restrictions for example, in hospitals, aircraft, petrol stations or in the vicinity of people with pacemakers may apply. Electronic devices can potentially cause hazards or interference or be subject to hazards or interference.
Warning signals
Hot surface Risk of electric shock
Overview
Filter
Particles injurious to health, including particulate matter, pollen, dust
mites, and smoke particles are removed by HEPA13 filter (4).
Correct setup of the air purifier
Ensure the purifier is positioned at least 50 cm to the side and 10 cm to the rear away from adjacent objects and electrical devices. The performance of radios and televisions can be negatively affected if their mains plug is plugged into the same socket strip as the air purifier’s mains plug. Use a separate power source for this reason. To ensure perfect operation, do not cover the air purifier or build constructions above it.
Operation
Insert the mains plug into the socket. A short beep sounds and all the displays flash twice. The Stand-by display then lights up red. Pressing the ON/OFF button (b) switches the device to automatic mode.
Functions
Adjusting the fan speed
Four fan speeds are available, from Low’,
Medium’ High’
Sleep’ and then
back to the start of the sequence. In Sleep mode, the device operates
particularly quietly (20 dB (A)) and the control panel is dimmed.
Press the fan speed symbol to switch Sleep mode on and off.
Filter reset button
When switched on, the air purifier counts down. When you switch the device off
and start it again, the countdown continues. A beep indicates that the filter
must be replaced after 2000 hours and the Change filter light flashes. Press the
Filter reset symbol (c) for 3 seconds after changing the filter. The pictogram
light up fully, stops flashing, and the beep ceases.
Set timer
You can use the timer function to set the device to switch off after 1, 2, 3 or
8 hours. Press the `Time’ symbol until you reach the required setting.
Child lock
Press the lock symbol (d) for 3 seconds to activate the child lock. The child
lock is off when the symbol is continuously lit and on when the symbol flashes..
Explanation PM 2.5
PM 2.5 fine particulate matter includes industrial emissions which can
penetrate deep into the respiratory tract due to their extremely small size,
causing long-term damage to the lungs.
PM 2.5| 0 – 50 pg/m3| 50 – 100 pg/m3| 100 – 150 pg/m3|
150 pg/m3 –
---|---|---|---|---
Coloured indicator| blue| green| purple| red
Status| perfect| good| normal| poor
Fitting the filter before the device is used for the first time
Take hold of the tab on the filter cover (1) which is located on the
underside of the device. Rotate the tab to the left until you can remove the
filter cover. Then remove the HEPA13 filter (2) from the device, remove all
packaging from the filter and insert the filter back into the device. Refit the
filter cover and rotate the tab to the right until it can go no further to fix
it in place.
Ensure you have disposed of the filter bag before switching the device on for the first time.
Changing the filter
- A flashing Filter reset button indicates the filter is due for replacement.
- Switch off the air purifier and disconnect from the mains.
- Remove the filter cover (3) on the underside of the device by rotating the tab (1) to the left and removing the filter cover.
- Remove the old HEPA13 filter (2) from the device.
- Remove packaging from the new HEPA13 filter.
- Insert the new HEPA13 filter into the device.
- Refit the filter cover onto the device and rotate the tab to the right until it can go no further to fix it in place.
- Press the Filter reset button for 3 seconds until the symbols are all lit and are not flashing.
Aromatherapy function
There are two sponges (a) in the filter cover. You can add a few drops of the
scent of your choice to the sponges.
When switched on, the device distributes the scent with the air flow to create
a pleasant atmosphere. There is also an option for using your own scent
pearls. Remove the sponges and replace them with the scent pearls.
Information on maintenance and care
Clean the housing with a damp cloth and do not use cleaning agents, scouring agents and solvents. Cleaning and/or maintenance work may only be carried out when the device has been disconnected from the mains. Protect the device from contamination and damage and store in a dry place.
Energy use and environmental considerations
State-of-the art, energy-efficient technology has been fitted in this device to conserve increasingly scarce natural resources in our environment. This means that incorrect usage can increase energy consumption. Switch the device off if the air quality is already good, there is external ventilation, or there are no people in the room. Remove the mains plug if the device is not in use for extended periods.
Technical data
Technical data (Subject to technical changes without notice. Rev22W28
Variable| Concentration of particular matter PM2.5
Fine particulate matter Measuring range
Accuracy| 0…5000 pg/m3 25 pg/m3
Sensor type| Fine particulate matter
Power supply| Mains voltage 230V / 50 Hz
Operating conditions| 0°C … 60°C, max. humidity, 75% rH, no condensation
Storage conditions| -10°C … 60°C, max. humidity, 85% rH, no condensation
Cable length| 1.5 m
Dimensions (W x H x D)| 225 x 310 x 225 mm
Weight| 2500 g
EU and UK directives and disposal
This device complies with all necessary standards for the free movement of
goods within the EU – and the UK.
This product, including accessories and packaging, is an electrical appliance
that must be recycled in an environmentally appropriate manner in accordance
with European and UK directives on waste electrical and electronic equipment,
batteries and packaging, in order to recover valuable raw materials.
Further safety and supplementary notices at: https://laserliner.com
SERVICE
Umarex GmbH & Co. KG
– Laserliner –
Möhnestraße 149, 59755 Arnsberg, Germany
Tel.: +49 2932 638-300, Fax: +49 2932 638-333
info@laserliner.com
Umarex GmbH & Co. KG
Donnerfeld 2
59757 Arnsberg, Germany
Tel.: +49 2932 638-300, Fax: -333
www.laserliner.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>