AKO 54041A Elevator Alarm 230v Power Supply Instruction Manual
- June 15, 2024
- AKO
Table of Contents
AKO 54041A Elevator Alarm 230v Power Supply
Product Information
Specifications
- Model: AKO-5404C
- Description: Emergency alarm and lighting system for lift cabins
- Compliance: European standard EN 81-1
- Power Supply: 230 Vac
- Emergency Lighting Output: 6 V, up to 500 mA
- Permanent Lighting Output: 6 V, up to 40 mA
- Auxiliary Relay: Yes (only for AKO-54041A)
- Dimensions: 115 mm (max) x 88 mm (min) x 183 mm
Description
The AKO-5404C is designed to provide alarm and emergency lighting in lift
cabins during a power outage. It ensures that the emergency lighting and
electronic alarm system continue to operate even if there is no voltage in the
mains supply. This product complies with European standard EN 81-1.
Features
- Includes electronic alarm and rechargeable batteries
- Can be installed outside the cabin or at a long distance where the alarm signal is needed
- Provides 6 V, up to 500 mA output for emergency lighting lamps
- Offers a permanent 6 V, up to 40 mA output
- AKO-54041A model has an auxiliary relay for remote device activation
Product Usage Instructions
Installation
To install the AKO-5404C, follow these steps:
- Ensure the dimensions of the installation space meet the requirements: 115 mm (max) x 88 mm (min) x 183 mm.
- Connect the input to a 230 Vac power source.
- For AKO-54041A and AKO-5404C models, connect the cabin push-button to the corresponding input.
- For AKO-5406 model, connect the 6 V, max 500 mA output to the emergency lighting lamps and the 6 V, max 40 mA output to any desired device.
Operation
The AKO-5404C operates as follows:
- In case of a power cut, the emergency lighting inside the lift cabin turns on automatically.
- The electronic alarm continues to operate using its own power source from the rechargeable batteries.
- When the power supply is restored, the emergency lighting turns off, and the unit begins to recharge automatically.
Maintenance
To maintain the AKO-5404C properly, follow these guidelines:
- Clean the surface of the equipment with a soft cloth, soap, and water.
- Avoid using abrasive detergents, petrol, alcohol, or solvents as they may damage the equipment.
Technical Specifications
- Lamps: 2 dial E10, 6 V, 200 mA
- Dimensions: 111 mm x 77 mm x 26 mm
FAQ (Frequently Asked Questions)
- Q: Can the AKO-5404C be installed outside the lift cabin?
- A: Yes, the AKO-5404C can be installed outside the cabin or at a long distance where the alarm signal is needed.
- Q: What is the purpose of the auxiliary relay in the AKO-54041A model?
- A: The auxiliary relay allows remote devices to be activated in conjunction with the AKO-54041A model.
- Q: What should I do if the emergency lighting does not turn on during a power cut?
- A: Please check the power supply connection and ensure that the rechargeable batteries are properly charged. If the issue persists, contact our customer support for assistance.
- Q: How often should I clean the AKO-5404C?
- A: It is recommended to clean the surface of the equipment periodically or as needed, using a soft cloth, soap, and water.
Description
- The purpose of the AKO-5404C is to provide the cabins with lifts with alarms and emergency lighting in case of a power cut.
- They provide sufficient power to operate the emergency lighting and the powerful electronic alarm, whether or not there is voltage in the mains supply.
- This equipment complies with European standard EN 81-1
Features
The power supply set includes an electronic alarm and recharge automatically their batteries. It is possible to install it outside of the cabin or at a long distance where the alarm signal is needed. It has an output to supply 6 V up to 500 mA to the emergency lighting lamps and a permanent one of 6 V up to 40 mA. The AKO-54041A have and auxiliar relay to act remote devices.
Advertencias
- If the equipment is used without adhering to the manufacturer’s instructions, the device safety requirements could be compromised.
- Always disconnect the power supply to do the wiring.
- For disconnection, the power supply circuit must be equipped with at least a 2 A, 230 V switch, located near the device and marked as an alarm cut-off device. The cables shall enter through the indicated part and shall be of type H05V-K or H05VVV-F. The 230 V~ connection area must be kept clear of any external elements. The cross-section to be used will depend on the local regulations in force, but must never be less than 1.5 mm2.
Installation
- Secure the alarm unit with 4 screws (A).
- Remove the connection cover (B) by pressing on the sides (C).
- Connect the cables according to the wiring diagram and replace the connection cover (B).
- AKO-5406: Fixing screws max. 4 mm diameter (D).
Wiring
Operation
In case of a power cut, the lighting inside the lift cabin comes automatically, the electronic alarm continues in operation due to its own power source from batteries. When the supply is restored, the lighting goes off and the unit begins to recharge automatically.
Maintenance
- Clean the surface of the equipment with a soft cloth, soap, and water.
- Do not use abrasive detergents, petrol, alcohol, or solvents.
Technical specifications
AKO-54041A / AKO-5404C
- Power supply………………………………………………………………………………………………………….230 V~ ± 10%, 50/60 Hz %
- Maximum input power……………………………………………………………………………………………………………………………3 VA~
- Nominal current………………………………………………………………………………………………………………………………….17 mA~
- Relay NO……………………………………………………………………………………………………………………………. 24 V 8 A cos =1
- Emergency lighting output………………………………………………………………………………………………………..6 V, max. 500 mA
- Permanent output…………………………………………………………………………………………………………………….6 V, max. 40 mA
- Autonomy time………………………………………………………………………………………………………………………………….> 1 hour
- Sound level…………………………………………………………………………………………………………………………..> 90 dB from 1 m
- Batteries…………………………………………………………………………………………………………………….. 5 of Ni-Cd, 1,2 V, 1,2 Ah
- Working ambient temperature……………………………………………………………………………………………………….. 5 ºC to 40 ºC
- Storage ambient temperature ……………………………………………………………………………………………………..-20 ºC to 50 ºC
- Working relative humidity…………………………………………………………………………………………………………………….. < 90 %
- Overvoltage category…………………………………………………………………………………………………………….. II s/ EN 61010-1
- Installation category………………………………………………………………………………………………………………. II s/ EN 61010-1
- Pollution degree…………………………………………………………………………………………………………………….. II s/ EN 61010-1
- Dimensions…………………………………………………………………………………………………………….212 mm x 139 mm x 52 mm
- Expected maximum altitude above sea level…………………………………………………………………………………………….. 2000 m
- Intended use……………………………………………………………………………………………………………………………………….. Indoor
- Installation………………………………………………………………………………Use 3.9 x 32 mm sheet metal screws with 5 dowels.
Double isolation between the power supply, secondary circuit, and relay output.
AKO-5406
Lamps…………………………………………………………………………………………………………………………..2 dial E10, 6 V, 200 mA
Dimensions………………………………………………………………………………………………………………111 mm x 77 mm x 26 mm