TRIPLETT 8150 CamView IP Pro 5 Inch 8MP Security Camera Tester User Manual
- June 9, 2024
- TRIPLETT
Table of Contents
8150 CAMVIEW5 CCTV TESTER
User Manual
8150 CamView IP Pro 5 Inch 8MP Security Camera Tester
- Thank you for purchasing the IP camera tester. Please read the manual before using the IP camera tester.
- Please first read the「Safety Information」carefully in the manual.
- The manual should be kept with unit in case reference is needed.
- Keep the S/N label for after-sale service within warranty period. Product without S/N label will be charged for repair service.
- If there is any question or problem while using the IP camera tester, or damage to the product, please contact our technical department.
Safety information
- The tester is intended for use in compliance with the local rules for electrical testers.
- To prevent the functional failure, the product should not come in contact with water.
- The exposed part of the tester should not be exposed to any liquids.
- During transportation and use, avoid vibration of the tester.
- Do not leave the tester unattended while charging. If the battery becomes overheated, the tester should be immediately removed from the electrical source. The tester should not be charged over 6 hours.
- Do not use the tester in high humidity conditions. Once the tester becomes damp, power off immediately.
- The tester should not be used in an environment with the flammable gas.
- Do not disassemble the instrument. There are no user replaceable parts inside.
- The instrument should not be used in an environment with strong electromagnetic interference.
- Do not touch the tester with wet hands.
- Do not use detergent to clean the unit. A dry cloth is recommended. If the dirt is not easy to remove, a damp cloth with water can be used.
IP Camera Tester Introduction
2.1 General
The 5.4-inch IPS touch screen IP camera tester is designed for maintenance and
installation of IP cameras, analog cameras, TVI, CVI, AHD, SDI/EX-SDI cameras,
as well as testing 4K H.264 /4K H.265 camera by mainstream. The 1920×1152
resolution enables it to display a high resolution image from the camera. The
meter supports many ONVIF and analog PTZ controls. The combination of touch
screen and touch control keys make the IP camera tester very user- friendly.
2.2 Packing list
- Tester
- Adaptor DC12V 1A
- Network cable tester
- Lithium ion battery
- BNC cable
- RS485 cable
- RJ45-BNC converter (Only for optional function cable tracer)
- DC12V Power cable
- Audio cable
- Safety cord
- Wrist belt
- Tool bag
- Manual
2.3 Function interface
1 | Menu key | |
---|---|---|
2 | Confirm key | |
3 | Return: Return or cancel while setting parameters of the menu | |
4 | 4x zoom the image display | |
5 | LED light | |
6 | The RS485 data transmission and received indicator lights red while the |
data is
being transmitted or received.
7| | The power indicator lights red while the tester is powered on by the
adapter
Top interface
Bottom interface
8| Press more than 2 seconds to turn on or off, short press to turn on or off
the menu display
---|---
9| Micro SD card removeable, supports up to 32G
10| DC12V 3A power output, temporarily supply power to the camera
11| PoE power supply output/LAN test interface
12| HDMI output
13| Video image /AHD/TVI/CVI signal input(BNC interface)
14| LED lamp
15| DC 12V 1A charging interface
16| RS485 Interface: RS485communication for PTZ control
17| Audio input
18| UTP cable port: UTP cable tester port/ Cable tracer port (Optional)
**Operation
**
3.1 Installing the Battery
The tester has a built-in lithium ion rechargeable battery. The battery should
be disconnected for safety during transportation!
Prior to the use of the instrument, please remove the battery insulation
paper. Pressing the key to power on /off the tester.
Notice: Please use the original adaptor and connected cable of the
device!
When the battery icon is full or the charge indicator turns off, battery
charging is completed.
Notice: When the Charge Indicator turns off, the battery is approximately
90% charged. Charging time can be extended for about 1 hour and the charging
time under 12 hours will not damage the battery.
Notice: Press the key several seconds to restore the default settings
when the instrument works abnormally.
Notice: While Charging, someone must be present.
4. IP camera test
4.1 Power output
Camera can be powered from the DC 12V/3A output or by Power over Ethernet.
4.2 IPC Test pro
Camera test often needs to open multiple apps, “IPC TEST PRO” app, using new
technology and combing multiple functions into one APP, can increase
efficiency.
Application:
Support multi-segment IP address scan, can visually display camera brand,
click IP address to display the image. Can supply the power to PoE camera.
Real-time display network port connection status.
Use one key to connect camera test tool, browser can login and configure
camera.
Batch activate Hikvision and Dahua cameras.
4.3 IP discovery
Press IP discovery , tester to auto-scan the entire network segment IP, as
well as auto-modify the tester’s IP to the same network segment with the
scanned camera’s IP. The meter auto-search the entire network segment IP, and
auto-add the IP from different network segments.
Local IP: Tester’s IP address, Tester can auto-modify the tester’s IP to the
same network segment with the scanned camera’s IP.
Discovery IP: Connected tester equipment’s IP address. If the camera is
connected to the tester directly, the tester will display the camera’s IP
address, if the tester connects to Local Area Network, it displays the current
IP address.
Start: PING function, click “Start”, can PING camera’s IP.
ONVIF: Rapid ONVIF Quick link.
IPC TEST: IPC TEST Quick link, Non-OnVIF IP camera test.
4.4 Rapid ONVIF test
Rapid ONVIF can display 4K H.265/H.264 camera image by tester’s mainstream.
The meter auto-scans all ONVIF cameras in different network segments. It lists
cameras’ name and IP address on the left of screen. Tester can auto login
camera and display camera image. Factory default uses admin password to auto
login, if you modified the password, then default uses the modified password
to login.
Click the button “Refresh”, the tester will scan the ONVIF camera again. Click
the newly displayed ONVIF camera on the “Device List”.
The tester will show the IP camera’s relative information and settings.
Pop-up settings menu when you click the “setting” icon in the upper left
corner.
Across network segments scan: After opening this function, Rapid ONVIF
function can scan across network segments to scan camera’s IP.
Auto Login: After opening this function, the tester can auto login camera and
display camera image (The login default password is “admin”)
Video transmission protocol: UTP and TCP protocol.
Show focus Info: Focus Information.
View manual: Opens the Manual.
Restore Defaults: Restore “Rapid ONVIF” to default settings.
Confirm: Save the modified parameters.
Click “MENU” icon to open camera setting.
While in the “Live video” menu, click “Video Menu” at the top right of the
image to access the following tools: Snapshot, Record, Photo, Playback, Lens
simulation, PTZ and Settings.
Network setting: Click “Network Set” to change the IP address. Some
cameras cannot support change IP address, so there is no change after saving.
When using the network video input, the tester supports resolutions up to
1080p, the input image remains clear after it is enlarged. This is helpful to
installers to ensure the IP camera’s video coverage and determine the IP
camera’s install site.
Lens simulation: Simulate different lenses’ display area. Supported lens:
“2.8/3.6/4/6/8/12/16/25mm”, for choosing the suitable camera lens.
OSD Menu: Select OSD and popup the OSD menu. include time, channel name and other optional items.
After selecting a channel, you can edit the channel name, modify the display
position, and switch the font size. Select “Content location – Default
location”. Select “Customize” to arbitrarily adjust the channel name and
display location.
Click “OK” to save the modification. Press return key or click any area on the
screen to return to the previous interface.
** Video files can play in the Video player on the main menu.
PTZ
Set preset position: Move the camera to preset position, enter the preset
number on the bottom right corner to complete position preset.
Call the preset position:** Select the preset number on the left, click
“Call” to call preset.
PTZ speed set: Horizontal and Vertical speed set.
Doc: Click “Create document”, to create a test report document for the
camera, . Click “Preview” to view the report document Enter the camera test
information, click “Create Document” to complete the report.
Click doc menu again, you can preview the report document.
Icons description: The description of function icons on the bottom
toolbar.
4.5 Non-OnVIF IP camera test
Display image from the 4K H.265 camera by mainstream.
Note: Currently, the IPC Test App only supports some brands’ specific IP
cameras, these include specific models made by ACTI, AXIS, Dahua, Hikvision,
Samsung, and many more. If the camera is not fully integrated, please use the
ONVIF or RTSP apps.
Local IP: This is the tester’s IP address. Click “Edit” to enter “IP
setting” and change the tester’s IP address settings.
IP camera type: Click on the IP Camera type to select the manufacturer
and model number of the connected IP camera.
Manual: Click IP camera type, list Honeywell, Kodak, Tiandy, Aipu-waton,
ACTi, WoshiDA IP camera etc. If the brand has official original protocols, pls
select camera type, input IP camera address, username and password, click
“official” to enter the camera image display interface.
Stream code: When testing the camera via RTSP, you can select mainstream
or sub stream to test (if camera’s RTSP has not been started, it will prompt
“auto match” fail, please switch to manual selection.
IP Camera’s IP: Enter the IP camera’s IP address manually or click
“Search” to auto-scan for the camera’s IP address. It is better to directly
connect the IP camera to the tester so the search results will only display
the camera’s IP address.
IPC Port: When you select the IP camera type, it will default the
camera’s port number and does not need to be changed.
After all settings are completed, click “Enter” to view the live video.
Analog camera test
5.1 CVBS
Analog camera test and PTZ control.
** Check and set the protocols, address, interface and baud, all must be
consistent with the dome camera for the tester to work. After setting
the parameter, the tester can control the PTZ and lens.
5.2 Auto HD**
Automatically recognize type and resolution of TVI/CVI/AHD camera and display
an image.
Support coaxial PTZ and call OSD menu. Support CVBS and 8MP TVI/CVI/ AHD
cameras. Select relative function on the right toolbar to operate, functions
including “Photos”, “Snapshot”, “Record”, “Playback”, “PTZ”, “Set”.
Double tap on the screen to display in full screen.
5.3 CVI camera test
When HD CVI signal input, the tester will display the image resolution at the
top of the screen. Double tap on the screen to display the image in full
screen.
The tester supports resolution up to 3840 x 2160P 12.5/15 FPS.
- PTZ control
1.1 Coaxial PTZ control
Click the icon “PTZ” on the right toolbar to do the corresponding setting.
“Port”: select coaxial control
Enter PTZ address to perform parameters setting.
The PTZ address in the tester must be consistent with the dome camera or
decoder for the IPC tester to work. After setting the parameter, the tester
can control the PTZ and lens.
Set preset position:
Move the PTZ camera to the preset position, tap it and input preset position
number. Tap “Set position” to complete set preset position.
Call preset position:
Tap the preset position area, input preset position number. Tap “call
position” to complete call preset position.
1.2 RS485 control
(2)Coaxial camera menu setting
Input calling dome camera menu address code, you can press the key “Enter” or
click the icon to call the dome camera menu.
set the parameters by
5.4 TVI camera test
When using an HD TVI signal input, the tester will display the image
resolution at the top of the screen. Double tap on the screen to display the
image in full screen.
The tester supports resolution up to 3840 x 2160P 12.5/15 FPS.
Coaxial camera menu settings:
Tap icon “UTC”, select “MENU” to enter the dome camera menu.
Input calling dome camera menu address code, after finishing the parameter settings, you can press the key “Enter” or click the icon to call the dome camera menu.
5.5 AHD camera test
When using an AHD signal input, the tester will display the image resolution
at the top of the screen. Double tap on the screen to display the image in
full screen.
The tester supports resolution up to 3840 x 2160P 15 FPS.
- Coaxial PTZ control
UTC control: Select “PTZ or PTZ-2” (AHD camera has two different order, if the “PTZ” not working, pls go “PTZ-2” )
To use coaxial PTZ control with the AHD camera, no parameter settings are
needed.
6.1 Network tool
-
IP address scan
Connect the cable to the LAN port, click icon to enter, set your IP address search range by changing the Start and End IP addresses.
Click the “Start” button to scan the IP address range. You can also input an IP address in the Port Number Scan to scan for open ports. -
PING Test
Application: PING testing is the most conventional network debugging tool. It is used for testing if the connected. IP camera or other network equipment’s Ethernet port is working normally, and the IP address is correct.
It is normal that the first data packet will be lost when testing starts. -
Network test (Ethernet bandwidth test)
To use the Network tester, you will need two IP testers. One is used as a Server and the other as a Client. In order to communicate, both devices must be on the same network segment. -
Port Flashing
Application:
The tester will send special signals to make the connected LAN port flicker at special frequency, which will aid the installer in finding the connected Ethernet cable easily and quickly. This function can prevent mistakenly inserting or disconnecting the wrong cable and interrupting network connection. -
DHCP server
Click on the DHCP icon to open the DHCP server app. Select the “Start” check box at the top and make any desired changes to the network settings. Click “Save” to start assigning dynamic IP addresses for IP cameras and other networked devices. Click the “Refresh” button to check your Client list. -
Trace route
It is used to determine the path of the IP packet access target.
Note: Trace route testing results only for reference, for accurate test route tracking, use a professional Ethernet tester. -
Link monitor
This app is used to see if an IP address is occupied by other network devices. This will avoid new address conflicts.
6.2 RJ45 cable TDR test
Connect cable to tester’s LAN port, click icon “ ” to enter app.
Single test: Test cable status, length and attenuation.
Repeat test: Continue to test cable status, length and attenuation.
Status: After link-up, the screen displays “online”, or for an open circuit,
the screen displays “open circuit”, if the cable pair has a short circuit, the
screen displays “short circuit”.
Length: The max test length is 180 meters, when the cable is open circuit
or short circuit, can test the cable length, if screen display “online”, the
testing result would not be accurate.
Cable quality test: Green is good quality cable, Yellow is poor quality
cable, Red is water damaged cable, the attenuation value will be displayed
when a cable is over 10 meters.
Advanced Test: Test cable pair status, length, attenuation, reflectivity,
impedance, skew and other parameters.
Attenuation reflectivity: After link-up, if the reflectivity value is 0,
it is the best quality communication
Impedance: After link-up, if the impedance value is 100 Ω, it is the best
quality communication, the range is generally in 85-135 Ω
Skew: After 1000M link up, if the skew value is 0ns, it is the best quality
communication, if over 50ns, it will cause a Bit Error Rate in the
transmission.
Click “Help”, check the instruction of all parameters.
6.3 Cable Tester
Click icon to enter.
Test LAN cable or telephone cable.
Connect LAN cable or telephone cable with the CCTV tester and cable tester.
And then the connecting status, cable type and the sequence of wires as well
as the serial number of the cable tester kit will be displayed.
The number of the cable tester is 255.
Quickly detect the near-end, mid-end and far-end fault point of RJ45 cable
connector
Cable test:
Tap “Diagram of the cable sequence”, pop up the connection diagram of
Straight-through cable and crossover cable. You can then create a test report.
6.4 PoE / DC12V 3A power output
When the tester is turned on, the DC12V power output functions are
automatically turned on.
To use the PoE Power Output function, change the switch “ON” or “OFF”.
The IP camera needs to connect the LAN port before you turn on PoE Power. If
the IP camera supports PoE, the PoE power is delivered via pins 1, 2, 3, and 6
on the LAN port. The IP tester will display “48V ON” at the top of the screen
when the POE power is on.
Note:
- Do not input power into the “DC12/3A OUTPUT” port.
- Do not output the DC12V/3A power into the DC12V/IN port of the IP camera tester.
- The IPC tester power output is close to 3A, if the IP camera’s power is over 3A, the tester will auto enter protection mode. Disconnect all tester connections and then connect the tester with the power adaptor to continue.
- Before turning on the PoE power output, make sure the IP camera supports PoE power. Otherwise it may damage the IP camera.
- Before turning on PoE power output, connect the IP camera to the LAN port of tester.
- Make sure the tester is full charged or more than 80% charged, or it will show “low power”, “not able to supply power”.
6.5 Update
Copy the downloaded update file to SD card “update” directory, if there is no
directory, please create one.
Click the icon to open the Update menu. Select “Local Update” to update via
the SD card or select “Online Update” to check for updates on the internet. If
there are applications that need updating, the applications will be listed in
the interface, click related applications, update to the latest version.
Online update: Connect the Internet to update the apps.
App management: This can uninstall and open APP.
6.6 File explorer
Click “File” on the top toolbar, to select internal or external storage. Click
on the upper right corner Icon “…”., to select other operations from the menu
or exit.
Browse
It includes Music, Videos, Pictures, Documents, zip file etc.to conveniently
view and manage.
FTP server
You can choose internal or external SD card.
For other operation details, refer to FTP settings.
6.7 System Setting
Language: Select your desired language: English, Chinese, Korean,
Russian, Italian, Polish, Spanish, French or Japanese.
Typewriting: You can select typewriting or install other typewriting:
Date/Time: Set the Date/time of the IP tester.
IP setting: Manually set the IP address, Subnet Mask, Default Gateway and
DNS address or select “Dynamic allocation” to use DHCP. To test multiple
network segments, click “Advanced” and then click “Add” to enter another IP
address for the IP tester.
WLAN Net: Turn WiFi off or on by pressing the “Open the wifi” button.
Once WiFi is turned on, click connected WIFI, to scan for wireless networks in
your area.
Select and press “WIFI” several seconds, to set static IP address.
Wi-Fi hotspot: Input “SSID” name and “password”, and then click “ok” to
create Wi-Fi hotspot.
Brightness: Set the desired brightness of the IP tester and adjust the
sleep time settings.
Volume: Set volume level
SD Card: Displays SD Card Capacity. You can also format the SD card or
unmount it before removing it.
FTP server: Once the IP tester connects to a network, a computer can be
used to read the SD card files via FTP.Start the FTP server and then input the tester’s
FTP address in the PC’s address bar. This will enable the PC to read, copy and
edit the files from the SD card without the use of SD card reader.
Version information: Shows applications version information, press any
apps icon several seconds to uninstall.
Screen display rotation: Click on “Screen Rotation” to flip the IP
tester’s display 180 degrees. This function is very convenient for the user to
connect the LAN cable on the bottom of the unit without having to flip the
unit itself.
PTZ address scan: You can toggle the PTZ Address scan off or on before
entering the “PTZ controller” app. This needs to be turned on in order to use
the PTZ Scan feature of the PTZ app.
Lock Screen: The meter default is not locked. You can choose password
Lock screen, pattern Lock screen or “NO”.
Restore the factory settings: If the tester is restored to factory
settings, all of your personal files and apps will be removed.
Power Off: Manually set Auto Off time (0-23h 59min).
Button mode selection: It can select button mode .
6.8 HDMI out
The built in HDMI output port can output live video from an analog or IP
camera, recorded files, media files and images to HDTV monitors. Connect an
HDMI cable from the IP tester to an HDTV monitor at any time. It supports up
to 3840x2160P 30FPS resolution.
Specifications
7.1 General Specifications
Model | 8150 Camview5 Security Camera Tester |
---|---|
**Display** | New 5.4-inch IPS touch screen cctv tester, 1920×1152 |
resolution
Network port| 10/100/1000M auto adjust, RJ45
WIFI| Built in WIFI, speeds150M, display wireless camera image
H.265 Main stream test| New hardware decoding, 4K H.265/H.264 camera
image display by mainstream testing
IP discovery| Auto-scan the whole network segment camera IP
**Rapid ONVIF| Search camera quickly, auto log in and display image
from the camera, activate Hikvision camera
****Hik test tool| Batch activate Hikvision camera, display image from
the camera, modify channel, batch modify IP, username and password parameters
etc.
****DH test tool| Batch activate Dahua camera, batch modify IP, modify
channel, username and password parameters etc.
****IP camera type| ONVIF, ONVIF PTZ, Dahua IPC-HFW2100P, Hikvision
DS-2CD864-E13, Samsung SNZ-5200, Tiandy TD-NC9200S2,
Kodak IPC120L, Honeywell HICC-2300T, RTSP Viewer
****Auto HD| Automatically recognize type and resolution of TVI/CVI/AHD
camera and display image. Support coaxial PTZ and call OSD menu
HD-SDI/EX-SDI camera test** *(Optional)| 1 channel SDI in(BNC
interface), resolution support upto 8MP: 720p 60fps / 1080p 60fps /1080i
60fps, EX-SDI: 2560x1440P /25/30FPS, 3840 x 2160P 25/30 FPS
CVI video signal test| 1 channel CVI input(BNC interface, resolution
support 8MP CVI camera test, 3840 x 2160P 12.5/15 FPS, 2880x1920P 20FPS,
2592x1944P 20FPS, 2560x1440p 25/30fps, 1920x1080p 25/30fps, 1280x720p
25/30/50/60fps, UTC control and call OSD menu
**TVI video signal test| 1 channel TVI input(BNC interface ),
resolution support 8MP TVI camera test, 3840 x 2160P 12.5/15 FPS,
2592x1944p12.5/20fps, 2688x1520p 15fps, 2560x1440P 18/25/30fps,
| 2048x1536p 18/25/30fps, 1920x1080p 25/30fps, 1280x720p 25/30/50/60fps, UTC
control and call OSD men
---|---
AHD video signal test| 1 channel AHD inpu(t BNC interface), resolution
support 8MP AHD camera test, 3840 x 2160P 15 FPS, 2592x1944p12.5/20fps,
2560x1440p 18/25/30fps, 2048x1536p 18/25/30fps, 1920x1080p 25/30fps, 1280x720p
25/30/50/60fps, UTC control and call OSD menu
Analog video test| 1 channel BNC Input, NTSC/PAL (Auto adapt)
Snapshot, Video record and playback| ** Capture current images
and record live video as JPG file. Media player will view photos and playback
video
**TesterPlay| screen projection: tester, mobile phone and PC display
at the same time
12V/3A power output| ** Output DC12V/3A power to camera
PoE power output| 48V PoE power output, Max power 25.5W
**Theme| Self-define icons, desktop and application interface
background, modify interface sliding effect
Audio test| 1 channel audio signal input
****PTZ control| Support RS485 control, Baud 600-115200bps, Compatible
with more than 30 protocols such as PELCO-D/P, Samsung, Panasonic, Lilin,
Yaan, etc
****Data monitor**| Captures and analyzes the command data from
controlling
device, also can send hexadecimal
**UTP Cable tester| Test UTP cable connection status and display on
the screen.
Read the number on the screen
Power
External power supply| ** DC 12V 1A
**Battery| Different item, battery is different, Built-in 7.4V Lithium
ion battery, 2600mAh/3350mAh
****Rechargeable| After charging 3-4 hours, normal working time 5 hours
or 6 hours (different item battery is different, the working time is different
Parameter
****Operation setting| OSD menu, select your desired language: English,
Chinese, Korean, Russian, Italian, French, Polish, Spanish, Japanese etc
Auto off| 1-30 (mins)
General
Working Temperature| ** -10℃—+50℃
---|---
Working Humidity| ** 30%-90%
Dimension/Weight**| 183mm x 110mm x 36.5mm /0.32kg
SBR2M
Security Camera Tester Borescope 2M (6.5ft) 8mm Diameter
**Introduction
**
Congratulations on your purchase of the Triplett SBR2M Security Camera Tester Borescope. This borescope paired with any security camera tester adds a borescope function to your security camera tester.
Features
- Waterproof (IP67) 8mm camera (Lens only)
- 2m cable (6.5ft)
- 6 adjustable LEDs with thumbwheel control
- Power provided by the camera tester (12V 1/2/3A) — no batteries needed
- Connection cables already included with your camera tester
- Utilizes the display resolution of your camera tester
- Image snapshot and Video record functions dependent on camera tester capability
Safety
This product is designed for industrial inspection camera.
- Avoid severe hits to the camera probe, and do not aggressively pull the cable.
- Please do not use it under high temperature, high magnetic environments or under strong light.
- Do not expose this product to extremely low or high temperatures
- If used for extended periods of time, please take out of the Alkaline battery from the device.
- Do not wipe the unit with corrosive chemical wash.
NOTICE:
WARNING ! This product is an industrial inspection camera and is not
intended for medical use or human examination.
Operation
- Locate the gender changing cables (for BNC and Power) supplied with your security camera accessory kit.
- Install onto the SBR2M.
- Connect to BNC Video IN and 12/1,2 or 3A Power output on the security camera tester.
- Click on Auto HD and the video will be displayed.
- Follow instruction for taking images and video as you would on your model camera tester.
**Note: The image below is for Reference Only – The SBR2M is shown being
paired up with the Triplett 8150 CAMVIEW IP PRO 5″ FULL TOUCH SCREEN 8MP
HIGH RESOLUTION SECURITY CAMERA**
Part Number – 8150-BR-Kit includes (1) SBR2M and (1) 8150.
Specifications
| SBR2M
---|---
Camera| 8mm
Field of View| 60°
Depth of View| 1.2 to 4″ (3 to 10cm)
Cable Length| 2m (6.5ft)
Resolution| 640 x 480
Illumination| 6 adjustable LEDs
Still Image Capture| dependent on camera tester
Video Recording| dependent on camera tester
Power| 12V 1/2/3A (provided by camera tester)
Interface| BNC
Dimensions| Camera & Cable: 6.5ft x 0.3” (2m x 8mm) LED
Thumbwheel: 2×0.5×0.25″ (51x13x6.4mm)
Weight| 5.6oz (159g)
Warranty
Triplett / Jewell Instruments extends the following warranty to the original
purchaser of these goods for use. Triplett warrants to the original purchaser
for use that the products sold by it will be free from defects in workmanship
and material for a period of (1) one year from the date of purchase. This
warranty does not apply to any of our products which have been repaired or
altered by unauthorized persons in any way or purchased from unauthorized
distributors so as, in our sole judgment, to injure their stability or
reliability, or which have been subject to misuse, abuse, misapplication,
negligence, accident or which have had the serial numbers altered, defaced, or
removed.
Accessories, including batteries are not covered by this warranty
Copyright © 2022 Triplett
www.triplett.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>