PORTFOLIO LDSSQ6C LER Cylinders Instruction Manual

June 15, 2024
Portfolio

PORTFOLIO LDSSQ6C LER Cylinders

Product Information

  • Product Name:
    • Portfolio LER4_LER6 Cylinders
  • Model Number:
    • IB52030322
  • Brand:
    • Cooper Lighting Solutions
  • Specifications:
    • Outer Diameter: 5.3″ (135.6 mm), 5.6″ (142.2 mm), 6.6″ (166.6 mm), 6.8″ (171.8 mm), 8.1″ (205.9 mm), 7.6″ (194.1 mm)
    • Height: 5.6″ (142.2 mm), 6.6″ (166.6 mm), 12.4″ (314.4 mm), 14.1″ (357.4 mm), 13.8″ (351.4 mm)

Product Usage Instructions

  • Ceiling Mounts
    • Installation Instructions for LERUD4, LERUDS4, LERWM4, LERWMS4
    • Read the installation instructions carefully before proceeding.
    • Ensure that the fixture is properly supported by main runners or other structures capable of supporting a weight of 40 lbs.
    • Install the fixture according to the provided diagram.
  • Wall Mounts
    • Installation Instructions for LESQ(R)UD4, LESQ(R)UDS4, LESQ(R)WM4, LESQ(R)WMS4
    • Read the installation instructions carefully before proceeding.
    • Inspect the fixture upon delivery for any shortage or noticeable damage and make a note of it on the delivery receipt.
    • File a claim for common carrier (LTL) directly with the carrier for any damages.
    • For concealed damage, file a claim within 15 days of delivery.
    • Retain all damaged materials and the original packing.
    • Install the wall mounting plate to the splice box using the provided splice box hardware.
    • Tighten the screws to 17 IN/LBS torque when using an 8-32 screw.
    • Refer to Figure 2 for visual guidance.
  • DMX Wiring Instructions
    • Ceiling Mount Version
    • Loosen and remove the 4 screws on top of the cylinder.
    • Remove the cylinder top to access the driver bracket assembly. Refer to Figure 5 for visual guidance.
  • FAQ
    • Q: What should I do if I notice any shortage or damage upon delivery?
    • A: Note the actual fixture description of any shortage or noticeable damage on the delivery receipt. File a claim for common carrier (LTL) directly with the carrier. Claims for concealed damage must be filed within 15 days of delivery. Retain all damaged material, complete with original packing.
    • Q: How should I install the fixture for wet locations/IP66?
    • A: For wet locations/IP66, the installer must apply silicone compound around the entire perimeter of the mounting arm where it mates to the cylinder housing.

Installation Instructions

Installation Instructions – Portfolio LER4_LER6 cylinders

  • WARNING:

    • Risk of Fire, Electrical Shock, Cuts, or other Casualty Hazards- Installation and maintenance of this product must be performed by a qualified electrician. This product must be installed per the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved.
    • Risk of Fire and Electric Shock- Make certain power is OFF before starting installation or attempting any maintenance. Disconnect power at the fuse or circuit breaker.
    • Risk of Fire- Minimum 90°C supply conductors.
    • Risk of Burn- Disconnect power and allow the fixture to cool before handling or servicing.
    • Risk of Personal Injury- Due to sharp edges, handle with care. Failure to comply with these instructions may result in death, serious bodily injury, and property damage.
  • DISCLAIMER OF LIABILITY: Cooper Lighting Solutions assumes no liability for damages or losses of any kind that may arise from the improper, careless, or negligent installation, handling, or use of this product.

  • IMPORTANT: Read carefully before installing the fixture. Retain for future reference.

  • NOTICE: The fixture may become damaged and/or unstable if not installed properly.

  • Note: Specifications and dimensions are subject to change without notice.

  • Note: This fixture should be supported by main runners or other structure that is capable of supporting a fixture weight of 40 Ibs.

  • ATTENTION Receiving Department: Note the actual fixture description of any shortage or noticeable damage on the delivery receipt. File claim for common carrier (LTL) directly with the carrier. Claims for concealed damage must be filed within 15 days of delivery.  All damaged material, complete with original packing must be retained.

Ceiling Mounts

Wall Mounts

PORTFOLIO-LDSSQ6C-LER-Cylinders-fig-1 \(2\)

Catalog Number Outer Diameter Height
  Ceiling Mounts Wall Mounts
LER(WM)S4 5.3” (135.6 mm) 6.8” (171.8 mm)
LER(WM)4 12.4” (314.4 mm) 11.5” (292.5 mm)
LERUDS4   12.5” (317.5 mm)
LERUD4 20.2” (512.6 mm)
LESQ(R)(WM)S4 5.6” (142.2 mm) 6.8” (171.8 mm)
LESQ(R)(WM)4 12.4” (314.4 mm) 11.5” (292.5 mm)
LESQ(R)UDS4   12.5” (317.5 mm)
LESQ(R)UD4 20.2” (512.6 mm)
LER(WM)S6 6.6” (166.6 mm) 8.1” (205.9 mm)
LER(WM)6 14.1” (357.4 mm) 12.7” (322.6 mm)
LERUDS6   11.2” (283.7 mm)
LERUD6 23.1” (586.0 mm)
LESQ(R)(WM)S6 6.6” (167.1 mm) 7.6” (194.1 mm)
LESQ(R)(WM)6 13.8” (351.4 mm) 12.5” (316.6 mm)
LESQ(R)UDS6   11.2” (283.7 mm)
LESQ(R)UD6   23.1” (586.0 mm)

INSTALLATION

Note: LED and Trim assembly are to be installed only after the cylinder is installed.
Surface Mount Cylinders

  1. Remove locking screw.
  2. Rotate the mounting plate in an anticlockwise direction to separate it from the assembly and remove it from the cylinder.  (Figure 1.)
  3. Attach the mounting plate to the Junction Box.
  4. Attach tether under one Junction Box mounting screw. (Figure 4.)
  5. Wire Unit per Wiring Diagram (refer to electrical section). Push wiring into the Junction Box.
  6. Insert tabs from the mounting plate into the cylinder top. Rotate the cylinder clockwise to engage hooks.
  7. Ensure holes are aligned, and install the Locking screw.
  8. For Wet Location/IP66 Installer must apply silicone compound around the perimeter of the mounting plate in contact with the ceiling.
  9. Also for Wet Location/IP66 Installer must apply silicone compound are the perimeter of the mounting plate in contact with the cylinder top.

Wall Mount Cylinders

  1. Install wall mounting plate to splice box using splice box hardware (provided by others) and tighten to 17 IN/ LBS torque when using 8-32 screw. (Figure 2.)PORTFOLIO-LDSSQ6C-LER-Cylinders-fig-1 \(3\)
  2. Wire unit per Wiring Diagram (refer to electrical section).
  3. Attach the rear wall mount tether to the splice box mounting screw, like what is shown in Figure 4.
  4. Mount the cylinder housing assembly to the wall by tightening screws on the top and bottom of the arm base to 17 IN/LBS torque to engage the mounting plate.
  5. The installer must apply silicone compound around the entire perimeter of the mounting arm where it mates to the mounting surface.
  6. For Wet Location/IP66 installer must apply silicone compound around the entire perimeter of the mounting arm where it mates to the cylinder housing.

DMX Wiring Instructions:
Ceiling Mount Version:

  1. Loosen and remove the 4 screws on top of the cylinder. Remove the cylinder top to access the driver bracket assembly. (Figure 5.)
  2. Fish DMX Cables (supplied by others) through holes in the mounting plate or mounting arm leaving approximately ten inches of wire.
  3. Proceed to mount the cylinder to the J-Box, keeping the top disconnected from the cylinder (Refer to the installation section of this instruction manual for details).
  4. The driver’s push-in connectors can be accessed by either removing the splice cover or the driver itself from the driver bracket by removing the indicated set screw. (Figure 6.)
  5. Connect DMX cables to Driver(s) per DMX wiring standards.
  6. Secure the driver or splice the cover back to the driver bracket with the set screw.
  7. Reconnect the cylinder top to the cylinder using the 4 top screws.

Up-Down Version:

  1. Remove wall mount arm from the fixture by removing (2) #8 screws
  2. Remove internal driver subassembly from the fixture. (Figure 7.)
  3. Remove the driver or the splice cover to access the driver push-in connectors. (Figure 6.)
  4. Feed the DMX cables through the wall mount arm and into the cylinder leaving enough excess cable to wire the driver from outside of the cylinder (See length table in the introduction sheet for overall fixture length).
  5. Connect DMX cables to drivers per DMX wiring standards.
  6. Insert the driver sub-assembly back into the cylinder making sure all cables are rerouted back through the wall mount arm.
  7. Reconnect the wall mount arm to the cylinder with the #8 screws
  8. Mount the fixture to the wall following the wall mount instructions in the installation section.

Cat 5 Version

  1. Locate Cat 5 receptacles. For ceiling-mounted cylinders, receptacles will be in the cylinder top, and wall-mounted cylinders will have the receptacles will be the wall mount arm. (Figure 8.)
  2. Complete Cat 5 connection per DMX Cat 5 standards.
  3. Complete fixture installation (see installation section).

Trim

  1. Remove lower trim from protective packaging. Rotate side clips (3) outwards. (Figure 9.) Remove the LED Engine from protective packaging.
  2. If the LED modules have 2 LEDs, gently remove the upper reflector by disengaging the white plastic latches (Figure 15. & Figure 16.) and discard it. Retain the upper reflector on the trim for 1LED modules.
  3. Insert LED engine onto the trim assembly. Align the post on the LED engine with a slot on the trim assembly. (Figure 10.)
  4. Rotate side clips (3) into place to securely attach the trim assembly to the LED engine. (Figure 11.)
  5. Plug in the luminaire and quickly disconnect the module. (Figure 12.)
  6. Find the green tether inside the cylinder and attach it to the heatsink using the screw and lock washer located in the envelope attached to the tether. (Figure 13.)
  7. Install the LED Engine and trim assembly by inserting the torsion springs into the spring receivers located inside the housing. (Figure 14.)PORTFOLIO-LDSSQ6C-LER-Cylinders-fig-1 \(15\)

Cleaning

To Clean Trims:

  1. Gently wipe with a soft, clean, dry lint-free cloth to remove dust.
  2. Wipe with a mild detergent solution on a soft, clean cloth to remove fingerprints and stains.
  3. Rinse with clean water and dry with a soft, clean, dry lint-free cloth.

Electrical Connection

CAUTION: Make certain no bare wires are exposed outside of wire nut connectors.

  1. Provide electrical service according to the “National Electrical Code” or your local electrical code to the cylinder housing assembly. Supply wire insulation must be rated for at least 90°C.
  2. Connect supply lead wires to the cylinder housing lead wires (line, neutral, and ground) in the fixture using properly sized wire nuts. Be careful not to leave any bare conductors outside of the wire nut connectors.
  3. Connect white to white, black to black, and green (from electrical service) on the supply side to the green wire in the cylinder housing assembly.

Wiring diagram B rev:

PORTFOLIO-LDSSQ6C-LER-Cylinders-fig-1 \(17\)

Wiring diagram C rev:

PORTFOLIO-LDSSQ6C-LER-Cylinders-fig-1 \(18\)

Constructions built before Jan 2022 may have gray wire for 0-10 dimming control present. In these cases, the installer will label the gray building wire as a 0-10 dimming wire and connect it to our product’s pink 0-10V dimming control wire. Reference NFPA70 (2020 NEC), section 410.69.

Dimming

  • The Portfolio *D010 Cylinders can be dimmed with many standard 0-10V DC dimming controls.
  • The Portfolio *D010TE Cylinders can be dimmed with many trailing edge dimmers and 0-10V DC dimming controls.
  • The Portfolio *DL2 Cylinders can be dimmed with Lutron 2-wire forward phase controls.
  • The Portfolio *D5LT Cylinders can be dimmed with Fifth Light and DALI DALI-compatible controls.
  • The Portfolio *DMX Cylinders can be dimmed with DMX-compatible controls.
  • The Portfolio *DE010 Cylinders can be dimmed with 0-10V DC dimming controls but are NOT to be dimmed using line voltage dimmers.
  • The Portfolio *DLE Cylinders can be dimmed with Lutron EcoSystem® digital controls.
  • To be assured of the latest information regarding luminaire and dimmer compatibility, please reference the Portfolio LED website: www.portfolio-lighting.com.

Warranties and Limitations of Liability

FCC

FCC Statement
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, under part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used by the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.
  • This device complies with Part 15 of the FCC Rules.

Operation is subject to the following two conditions:

  1. this device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.

This device complies with ISED ICES Standard Canada ICES-005 (A) / NMB-005 (A) or ICES-005 (B) / NMB-005 (B) depending on the driver selected. Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

CONTACT

  • Cooper Lighting Solutions
  • 1121 Highway 74 South
  • Peachtree City, GA 30269
  • P: 770-486-4800
  • www.cooperlighting.com.
  • Canada Sales
  • 5925 McLaughlin Road
  • Mississauga, Ontario L5R 1B8
  • P: 905-501-3000
  • F: 905-501-3172
  • © 2022 Cooper Lighting Solutions All Rights Reserved Printed in USA
  • Publication No. IB52030322

March 28, 2023, 12:59 PM Cooper Lighting Solutions is a registered trademark. All trademarks are the property of their respective owners. Product availability, specifications, and compliances are subject to change without notice.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Portfolio User Manuals

Related Manuals