E-RJ8-RS485 RJ45 Sensor Port Hub Datasheet
Installation Manual
Features:
- Supports the connection of up to eight NTI RS485 sensors using one RJ45 sensor port.
- Up to three E-RJ8-RS485 can be connected to an E-16D
- Up to two E-RJ8-RS485 can be connected to an E-5D
- One E-RJ8-RS485 can be connected to an E-2D
- Provides RJ45 modular jacks for connecting NTI RS485 sensors such as temperature, humidity, temperature/humidity, AC voltage, and current monitor, DC voltage monitor, and others.
- Supports CAT5/5e/6 cable up to 1000 ft. (305 m) between E-16D and hub. Sensor cable lengths connected to the hub are as specified per sensor (maximum 1000ft. each). (i.e. the E-S420MA-24V has a maximum specified CATx cable length of 500ft.(152m))
- Powered by 12VDC 2.5A external power supply (included).
- Compatible with E-2D/5D/16D (firmware version 3.8 and newer)
- Regulatory approvals: CE, RoHS
- Operating temperature: 32 to 158°F (0 to 70°C)
- Storage temperature: -4 to 176°F (-20 to 70°C)
- Compatible with E-SER-2FOSMST Fiber Converter/Extender.
- Use to extend the hub up to 1.2 miles (2 km) from the ENVIROMUX unit.
Note: The E-RJ8-RS485 does not directly support contact sensors (i.e. Motion Sensor, Door Contact Switch, Smoke Detectors, etc). The Alarm/Sense (Pin 2) and Tamper (Pin 5) signals of the RJ45 Sensor port in an E-xD are not supported. To connect contact sensors, an E-DI16DO(R)16 Digital Input Expander must first be connected.
Connections
-
Connect a CATx patch cable up to 1000 feet long (24AWG minimum at this length) between an RJ45 Sensor port on the E-xD and the “CATx to E-xD” port on the E-RJ8-RS485.
Note: The length of the CATx cable that can be used between the E-RJ8-RS485 and the sensor will vary. Refer to the manual for each sensor to be connected for cable length limitations.
-
Connect the 12VDC power supply to the E-RJ8-RS485 and plug it into power.
-
Connect up to 8 NTI RS485 sensors to the 8 ports on the E-RJ8-RS485. Some limitations apply, see the chart below for the current list of compatible sensors.
RS485 Sensors and Adapters are used with the E-16D/5D/2D.
NTI # | Description |
---|---|
E-ACDCLM | AC & DC Voltage and Current Monitor |
E-ACLM-3P480 | 3-Phase Power Monitor |
E-ACLM-P-xx | AC Line Monitors |
E-ACLM-V | AC Line Monitor |
E-ALDS | Leak Location Detection Sensor |
E-DCLM-6 | DC Voltage and Current Line Monitor |
E-DI1 6D01 6 | Digital Input/Output Expander |
E-DI16DOR16 | Digital Input/Output Expander |
E-S420MA-24V | Current Sensor Adapter |
E-S5VDC | Voltage Sensor Adapter |
E-S60VDC | Voltage Detector Converter |
E-STHSM | Temperature/Humidity Sensor |
E-STHSB | Temperature/Humidity Sensor |
E-STHS-LCDW | Temperature/Humidity Sensor W/ LCD |
E-STS | Temperature Sensor |
E-STS-O | Outdoor Temp Sensor-Cable Restraint Assembly |
E-STSP-7 | Pipe Temperature Sensor |
E-STSP-SL-7 | Pipe Temperature Sensor-Spring Loaded |
Note: Any additional RS485 sensors that become available from NTI will
also be compatible unless otherwise indicated.
Note: Sensors connected to the E-RJ8-RS485 are not visible using E-MNG
management software but are visible in E-MNG-SH management software.