Dr ger PARAT 1260 Respirator Mask Instruction Manual

June 14, 2024
Dr ger

Drager PARAT 1260 Respirator Mask

Product Information

Specifications

  • Approved body: BSI Assurance UK Ltd.
  • Kitemark Court Davy Avenue Knowlhill Milton Keynes MK5 8PP United Kingdom
  • Identification number: 0086
  • Notified body involved in quality control: DEKRA EXAM GmbH
  • Dinnendahlstr. 9 44809 Bochum Germany
  • Reference number: 0158 0121
  • Importer (UK): Draeger Safety UK Ltd
  • Ullswater Close, Blyth Riverside Business Park Blyth, Northumberland NE24 4RG, UK

Product Usage Instructions

Safety Information
This product contains safety-related information that you should be aware of before using it.

Meaning of the warning notices
The following warning notices are used in this document to alert the user to potential hazards. The meanings of the warning notices are defined as follows:

  • DANGER
    Indicates an imminently hazardous situation. If not avoided, it will result in death or serious injury.

  • WARNING
    Indicates a potentially hazardous situation. If not avoided, it could result in death or serious injury.

  • NOTICE
    Indicates a potentially hazardous situation. If not avoided, it could result in damage to the product or environment.

Description
This product has the following features and characteristics:

  • PARAT 1200 : [Description of PARAT 1200]
  • PARAT 1260 : [Description of PARAT 1260]

Frequently Asked Questions (FAQ)

How do I properly store the product?
The product should be stored within the specified temperature range mentioned in the manual.

What is the expiration date for the product?
The expiration date can be found on the product label or packaging.

What is the weight of the product?
The weight of the product is [weight information].

Instructions for use

Safety-related information

  • Before using this product, carefully read the instructions for use.
  • Strictly follow the instructions for use. The user must fully understand and strictly observe the instructions. Use the product only for the purposes specified in the intended use section of this document.
  • Do not dispose of the instructions for use. Ensure that they are stored and used appropriately by the product user.
  • Only trained and competent users are permitted to use this product.
  • Comply with all local and national rules and regulations associated with this product.
  • Do not use a faulty or incomplete product. Do not modify the product.
  • Notify Dräger in the event of any component fault or failure.

Conventions in this document

Meaning of the warning notices
The following warning notices are used in this document to alert the user to potential hazards. The meanings of the warning notices are defined as follows:

Trademarks

  • Trademark : PARAT®
  • Owner of trademark: Dräger

Description

WARNING: Danger to health
The Dräger PARAT 1200/1260 does not protect against carbon monoxide or in cases of oxygen deficiency!

Failure to heed this warning may result in death or serious physical injury.

Intended use
The Dräger PARAT 1200/1260 is a filtering escape apparatus to aid self-rescue from:

  • Organic gases and vapors with a flash point over 65°C
  • Inorganic acid or base gases and vapors such as sulfur dioxide, hydrogen chloride, and ammonia.

The products are designed for a maximum escape duration of 10 minutes. They are not designed to be reused. In cases of very high gas concentrations or unusual gases, such as those with a flash point below 65 °C, the nominal filter exposure time may be reduced. The operator must conduct a risk assessment to determine whether the products are suitable for the application at hand. Inexperienced users may have difficulty breathing. These filtering escape apparatus are stored in a plastic housing. In the PARAT 1260, the filtering escape apparatus is packaged in a barrier bag.

Approvals
The Dräger PARAT 1200/1260 is certified in accordance with:

  • DIN 58647-7:1997
  • (EU) 2016/425
  • Regulation 2016/425 on personal protective equipment, as amended to apply in GB

Declarations of conformity: see www.draeger.com/product- certificates.

Filter types


Symbol explanations

  • Follow the instructions for use.
  • Do not speak while wearing the filter!
  • Expiry date
  • Weight
  • Storage temperature range
  • Maximum humidity during storage
  • Date of manufacture (see explanations at www.draeger.com/isu?SearchTerm=9021650)
  • Industrial escape applications

Use

NOTICE
Regularly perform a visual inspection of the filtering escape apparatus to ensure that:

  • The expiration date has not passed
  • The sealing tag on the plastic housing has not been damaged

If the expiration date has passed or the sealing tag is broken, replace the escape apparatus.

NOTICE
The filtering escape apparatus may be unsuitable for users who have complete dentures.

Only use the filtering escape apparatus if it is undamaged. Open the housing cover (Fig. 1).

  1. Dräger PARAT 1200: Remove the filter (Fig. 2). Dräger PARAT 1260: Remove the barrier bag containing the filter. Rip open the barrier bag as indicated and remove the mouthpiece assembly (Fig. 2).
  2. Using your thumb and index finger, lightly push the mouthpiece together around the mouthpiece tab and place in your mouth. Bite the mouthpiece tab. Surround the mouthpiece with your lips.
  3. Put on the nose clip (Fig. 3). If the nose clip slips, hold your nose shut.
  4. Leave the danger zone immediately.

DANGER: Danger to health
If the user speaks while wearing the apparatus, the respiratory poison may enter the respiratory tract and cause serious health issues or even death.

  • Do not speak while wearing the Dräger PARAT 1200/1260.
  • Do not take off the device for coughing or sneezing!

Maintenance

The maximum life span of the PARAT 1200/1260:

  • Dräger PARAT 1200 4 years
  • Dräger PARAT 1260 6 years

The Dräger PARAT 1200 is marked with an individual weight.

Example:

Weigh the complete device, including its housing, for the first time after one year (expiration date minus 3 years) and then every 6 months. If the measured weight is higher than the weight indicated on the product, dispose of the Dräger PARAT 1200. Remove any contamination from the product before weighing. Factors such as labels or dust can influence the weight.

The Dräger PARAT 1260 does not require maintenance. Once the specified expiration date has passed, dispose of the filtering escape apparatus.

Storage

WARNING: Danger to health
Failing to store or transport the filtering escape apparatus as specified in the storage conditions may impair the filter performance.

  • Always follow the instructions in the storage conditions.

Storage conditions

Store the filtering escape apparatus in a cool, dry place. Avoid direct sunlight.

On average over a period of several weeks

If warm and humid ambient conditions for a period of several weeks of the storage period cannot be ruled out due to the local climate, e.g. in subtropical and tropical climates, Dräger advises that the filter performance may deviate from the requirements of the standard as the apparatus ages. In such cases, Dräger recommends using the product variant Dräger PARAT 1260 with a high-quality aluminum barrier bag to protect the filter against critical climatic impacts over the entire life span of the apparatus.

Disposal
Dispose of the product in accordance with the applicable rules and regulations.

Approved body:
BSI Assurance UK Ltd. Kitemark Court Davy Avenue Knowlhill Milton Keynes MK5 8PP

United Kingdom
Identification number: UKCA 0086

Manufacturer
Dräger Safety AG & Co. KGaA Revalstraße 1 D-23560 Lübeck Germany +49 451 8 82-0

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>