Anolis Eminere 1 LED Lighting Owner’s Manual
- June 14, 2024
- ANOLiS
Table of Contents
Eminere® 1
Eminere® 2
Eminere® 3
Eminere® 4
User Manual
Version 3.2
Eminere 1 LED Lighting
https://www.anolislighting.com/resource/eminere-1234-user-manual
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE POWERING
OR INSTALLING YOUR Eminere !
Save it for future reference.
This device has left our premises in absolutely perfect condition. In order to
maintain this condition and to ensure safe operation, it is absolutely
necessary for the user to follow the safety instructions and warnings written
in this manual.
The manufacturer will not accept liability for any resulting damages caused by
the non-observance of this manual or any unauthorized modification to the
device.
Unauthorized modification will void warranty.
Safety instructions
DANGEROUS VOLTAGE CONSTITUTING A RISK OF ELECTRIC SHOCK IS PRESENT WITHIN
THIS UNIT!
This fixture should be operated only from the type of power source
indicated on the marking label. If you are not sure of the type of power
supplied, consult your authorized distributor or local power company.
Always disconnect the fixture from AC power before cleaning, servicing or
installing.
Make sure the data/power cable is not damaged by sharp edges. Check the
fixture and the power cord from time to time.
Do not install the unit near an open flame.
During operation the housing becomes hot.
Refer servicing to qualified service personnel.
This fixture falls under protection class I. Therefore this fixture has to
be connected to a mains socket outlet with a protective earthing connection.
Do not connect this fixture to a dimmer pack.
LED light emission. Risk of eye injury. Do not look into the beam from a
short distance without suitable protective eyewear. Do not look at LEDs with
magnifiers or similar optical instruments that may concentrate the light
output.
The fixture was designed for outdoor use. This fixture must not be used for
underwater installation.
When choosing the installation spot, please make sure that the fixture is not
exposed to extreme heat or dust.
Avoid using the unit in locations subject to possible impacts.
The fixture body never must be covered with cloth or other materials when the
fixture is under operation.
Only operate the fixture after having checked that the housing is firmly
closed and all screws are tightly fastened.
The fixture becomes hot during operation. Allow the fixture to cool
approximately 30 minutes prior to servicing or maintenance.
Operate the fixture only after having familiarized yourself with its
functions. Do not permit operation by persons not qualified to operate the
fixture. Most damages are the result of unprofessional operation!
Please consider that unauthorized modifications on the fixture are forbidden
due to safety reasons! Please use the original packaging if the fixture is to
be transported.
If this device will be operated in any way different to the one described in
this manual, the product may suffer damages and the warranty becomes void.
Furthermore, any other operation may lead to dangers like short-circuit,
burns, electric shock etc.
The product (covers and cables) must not be exposed to a high frequency
electromagnetic field higher than 3V/m. Immunity of the equipment is designed
according to the standard EN 55035 Electromagnetic compatibility of multimedia
equipment – Immunity requirements Emission of the equipment complies with the
standard EN55032 Electromagnetic compatibility of multimedia equipment –
Emission Requirements according to class B.
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
The [Device] wireless operation is safe and complies to RF Exposure
requirements.
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Warning for fixtures with Harsh Environment Finish (HEF):
Handle with care!
Avoid any damage to the painted surface.
Damaging the paint may result in corrosion and loss of warranty.
Fixture exterior view
- Transparent glass cover
- LED module
- Output connector
- Input connector
- Mounting brackets
- Aluminium base
Installation
3.1 Mounting the fixture
The Eminere can be arranged in any orientation on a flat, non-flammable
surface by means of two mounting brackets (5), the LED module (2) can be
tilted (+95°/-95°) to get access to mounting brackets (5).
Ensure that the structure to which you are attaching the unit is secure.
3.2 C-clamps installation
- Remove the mounting bracket (5) from fixture housing by unscrewing two screws (6).
- Screw the new mounting bracket (9) to the fixture housing by means of two screws (6).
- Screw the clamp (7) to the mounting bracket by means of the bolt M12x30 (10) with nuts M12 (8).
3.3 Connection to mains
The unit must be installed by a qualified electrician in accordance with
all national and local electrical and construction codes and regulations.
This device falls under class one and must be grounded!
The Eminere is equipped with auto-switching power supply that automatically
adjusts to any 50/60Hz AC power source from 120-277 Volts.
The following wiring of the input/output connectors applies to the fixtures
marked X on their labels only. Older versions of the Emineres have swapped D-
and D+ and do not have mark X on their labels.
Fixture´s Amphenol connectors are dust and water protected according to IP 67
by mating with related Amphenol connectors.
They cannot stay disconnected outdoor.
The output panel connector at last fixture in the Eminere chain has to always
be covered with the water-tight cap to keep declared IP rating.
The Eminere modules should be connected to the E-box which allows power supply
of the Eminere modules and their control.
Do not connect (disconnect) Emineres to the E-box or Booster box and each
other when they are under voltage!
When you change any setting of the E-box, disconnect the E-box from power and
connect it to power again to activate changes which you have made.
Examples of connection for various versions of the E-box.
Please read the E-box user manual for more information about its setting and
connection to Eminere modules.
Needed cables are stated in the chapter “Technical information“.
Number of connected Emineres to one E-box output depends on a cable length,
power voltage, type of Eminere and E-box and operation mode.
The tables below state max. theoretical number of Emineres connected to the
one LED output of the E-box without Booster boxes. The following tables apply
for the Standard mode of E-boxes.
EMINERE 1 | Voltage |
---|---|
**Cable length*** | 120V |
10 m | 83 |
20 m | 83 |
30 m | 58 |
50 m | 35 |
70 m | 25 |
100 m | 17 |
200 m | 9 |
EMINERE 2 | Voltage |
--- | --- |
**Cable length*** | 120V |
10 m | 41 |
20 m | 41 |
30 m | 28 |
50 m | 17 |
70 m | 12 |
100 m | 9 |
200 m | 4 |
EMINERE 3 | Voltage |
--- | --- |
**Cable length *** | 120V |
10 m | 28 |
20 m | 28 |
30 m | 19 |
50 m | 12 |
70 m | 8 |
100 m | 6 |
200 m | 3 |
EMINERE 4 | Voltage |
--- | --- |
**Cable length*** | 120V |
10 m | 21 |
20 m | 21 |
30 m | 15 |
50 m | 9 |
70 m | 6 |
100 m | 4 |
200 m | 2 |
- Cable length is a total cable length between E-box and last connected Eminere.
Example: Total cable length=L1+L2+L3
Notice for the E-box Star: The tables above state max. total number of Emineres connected to 6 LED outputs of the E-box Star (or max. number of Emineres connected to one output if the rest of outputs is not connected).The E-box Star has only one power input!
3.4 The Booster box
To compensate a voltage drop in large installation, the Booster boxes have to
be connected in the chain of Emineres at every LED output of the E-box.
The following tables give numbers of Emineres after which the Booster box has
to be installed in the chain of Emineres (at one LED output of the E-box). The
following tables apply for the Standard mode of E-boxes.
EMINERE 1|
Max. number of Emineres 1= 191
---|---
|
Voltage
Cable length| 120V| 190V| 230V| 277V
10 m| 83,166| 131| 159| –
20 m| 83,166| 131| 159| –
30 m| 58,116,174| 131| 159| –
50 m| 35,70,105,140,175| 88,176| 128| 186
70 m| 25,50,75,100,125,150,175| 63,126,189| 92,184| 133
100 m| 17,34,51,68,85,102,119, 136,153,170,187| 44,88,132,176| 64,128| 93,186
200 m| 9,18,27,36,45,54,60,72,81 90,99,108,117,126,135,144
153,162,171,180,189,| 22,44,66,88,110, 132,154,176| 32,64,96,128, 160|
47,94,141, 188
EMINERE 2|
Max. number of Emineres 2= 94
---|---
|
Voltage
Cable length| 120V| 190V| 230V| 277V
10 m| 41,82| 64| 78| –
20 m| 41,82| 64| 78| –
30 m| 28,56,84| 64| 78| –
50 m| 17,34,51,68,85| 43,86| 63| 91
70 m| 12,24,36,48,60,72,84| 31,62,93| 45,90| 65
100 m| 9,18,27,36,45,54,60,72,81, 90| 21,42,63,84| 31,62,93| 46,92
200 m| 4,8,12,16,20,24,28,32,36 40,44,48,52,56,60,64,68,72 76,80,84,88,92|
11,22,33,44,55, 66,77,88| 16,32,48,64,80| 23,46,69,92
EMINERE 3|
Max. number of Emineres 3= 64
---|---
|
Voltage
Cable length| 120V| 190V| 230V| 277V
10 m| 28,56| 44| 53| –
20 m| 28,56| 44| 53| –
30 m| 19,38,57| 44| 53| –
50 m| 12,24,36,48,60| 29,58| 43| 62
70 m| 8,16,24,32,40,48,56| 21,42,63| 31.62| 44
100 m| 6,12,18,24,30,36,42,48,54, 60| 15,30,45,60| 21,42,63| 31,62
200 m| 3,6,9,12,15,18,21,24,27,30, 33,36,39,42,45,48,51,54,57 60,63|
7,14,21,28,35,42 49,56,63| 11,22,33,44,55| 16,32,48,
EMINERE 4|
Max. number of Emineres 4= 48
---|---
|
Voltage
Cable length| 120V| 190V| 230V| 277V
10 m| 21,42| 33| 40| –
20 m| 21,42| 33| 40| –
30 m| 15,30,45| 33| 40| –
50 m| 9,18,27,36,45| 22,44| 32| 47
70 m| 6,12,18,24,30,36,42| 16,32| 23,46| 38
100 m| 4,8,12,16,20,24,28,32,36, 40,44| 11,22,33,44| 16,32| 23,46
200 m| 2,4,6,8,10,12,14,16,18,20, 22.24.26,28,30,32,34,36,38 40,42,44,46|
5,10,15,20,25,30 35,40,45| 8,16,24,32,40| 12,24,36
Example: E-box Daisy, Power supply= 230V, Cable length=70m,
fixture=Eminere 2
The Booster box has to be connected after every 45th Eminere 2 (fixture 45 and
fixture 90) from 94 fixtures.
3.5 The Booster box installation
ALWAYS DISCONNECT THE EMINERES FROM MAINS BEFORE CONNECTING/DISCONNECTING THE
BOOSTER BOX.
The Booster box falls under protection class I. Therefore, every Booster box
has to be connected to a mains socket outlet with a protective earthing
connection.
- Unscrew the four screws (1) from the cover (2) on the Booster box to get access to the terminal block (3) and two mounting holes of diameter of 4.6 mm (4).
- Screw the Booster box on a non-flammable flat surface and connect cables.The Cable gland M20x1.5 for Power IN (5) is intended for a cable of a diameter of 7-13mm.
Remove the end cap from the cable gland before passing the cable.
Power connection| L| N| (earth)
---|---|---|---
Core (EU)| Braun| Blue| Green/yellow
Core (US)| Black| White| Green
We recommend to apply an adequate layer of the paste LOCTITE 5331 on the
plastic holder of the cable gland before inserting it into the body of the
gland and an adequate layer of the paste LOCTITE 577 on the thread of the
gland body.
Cable gland M20 MS:The cable gland M20 MS with a standard seal serves
for a cable of diameter of 7-13mm, for smaller diameter of cable (4-8mm) you
have to remove the original seal from the cable gland M20 and use the enclosed
reducing seal instead of it. The reducing seal for diameter of cable 4-8mm
(P/N 13051388) is enclosed in the Booster box.![Anolis Eminere 1 LED Lighting
-
The cable gland](https://manuals.plus/wp-content/uploads/2023/11/Anolis- Eminere-1-LED-Lighting-The-cable-gland.jpg)
- Screw the cover (2) back on the Booster box.
3.6 Jumper cable assembling
-
Dismantle the connector and slide its parts onto the cable (6).
Use the seal with inner diameter of 14.5 mm for the Anolis cable (P/N 13053138 or P/N 13053139).
The seal with inner diameter of 14.5 mm serves for cable of diameter 10-14.5mm.
The seal with inner diameter of 10 mm serves for cable of diameter 8-10mm. -
Put the seiling circle (2) on the connector with screws (1).
-
Remove insulation from the cable (6) and from individual wires and fasten three terminals on data wires.
-
Put parts of the connector on the cable (6) and connect wires to the connector. First connect power wires (L,N, Earth) and after that data wires (D+, D-, 0V). Avoid excessive torsion of data wires!
-
After connecting wires to the connector, tighten the three data wires (D+,D-, 0V) by means of the cable binder (7).
-
Screw the clamp ring (3) to the connector (1), insert the seal (4) to the clamp ring (3) and tighten the sealing nut (5) enough. During the steps DO NOT TWIST the cable (6).
-
Use the same procedure to assemble the connector on the second end of the cable.
IMPORTANT
Do not bend the cable near to the connector, minimum distance for bending
is 50mm.
Software update
Software update of Eminere has to be done by means of the software ROBE
Uploader running on PC.
The ROBE Uploader is a software for automatized software update of ROBE
fixtures. The ROBE Uploader switches Emineres to the update mode
automatically.
Please see https://www.robe.cz/robe-uploader/ for more information.
DMX or Ethernet connection via E-box
If the option Standard is selected from the menu E-box mode and LED modules
are connected in series, the E-box will be updated including connected Eminere
modules. You have to use the file EminereEbox.lib in the ROBE Uploader for
this operating mode.
If the option Pass-Thr is selected from the menu E-box mode and LED modules
are connected in series, you have to do the following steps to update Emineres
including the E-box:
-
Set the E-box to the Standard mode and switch it off/on. Only E-box will be shown in the ROBE Uploader. \
You have to use the file EminereEbox.lib in the ROBE Uploader for software update of the E-box and connected LED modules. -
After updating, set the E-box to the Pass-Thorough mode and switch it off/on.
For more information about updating please see the E-box Lite/Daisy/Star user manual.
Technical specifications
Power supply
-
Electronic auto-ranging
-
Input voltage: 120 – 277V AC, 50/60 Hz
-
Power consumption:
Eminere 1: 25W
Eminere 2: 45W
Eminere 3: 65W
Eminere 4: 85W -
Inrush current:
Eminere 1: <70A/250µs
Eminere 2: <70A/250µs
Eminere 3: <100A/200µs
Eminere 4: <100A/200µs
Optic
-
Light source:
Eminere 1: 12 x high power LEDs
Eminere 2: 24 x high power LEDs
Eminere 3: 36 x high power LEDs
Eminere 4: 48 x high power LEDs -
Colour variants: RGBW, RGBA, single colour
-
Beam Angle:
Symetrical: 9°, 15°, 30°, 50°, 65°, 100°
Bi-symetrical: 10° x 30°, 30° x 10°, 10° x 60°, 60° x 10°, 35° x 70°, 70° x 35°, 15° x 90°, 90° x 15°
Wallwasher, Wide Wallwasher -
Projected Lumen Maintenance: L90B10 >90.000 hrs, Ta = 25°C / 77°F
Compatible drivers
-
E-box Daisy
1 Output
1 Main power Input
Control: DMX, Art-Net, sACN , W-DMX control, RDM
Pixel control (1px= 1ft)
120-277V Input
Connection via terminal blocks, inlets via grommet
IP67 -
E-box Star
6 outputs
1 Main power Input
Control: DMX, Art-Net, sACN , W-DMX control, RDM
Pixel control (1px= 1ft)
120-277V Input
Connection via terminal blocks, inlets via grommet
IP67 -
E-box Pro
6 outputs
6 Main power Inputs
Control: DMX, Art-Net, sACN , W-DMX control, RDM
Pixel control (1px= 1ft)
120-277V Input
Connection via terminal blocks, inlets via grommet -
E-box Lite
1 output
1 Main power Input
Control: DMX, W-DMX control, RDM
Pixel control (1px= 1ft)
120-277V Input
Connection via screw terminal blocks, inlets via grommet
IP67
Mounting method
- Via two L-shape brackets
LED module “tilt” adjustment range: -95°/+95°
Sizes
- Eminere 1 (300mm / 1ft)
- Eminere 2 (600mm / 2ft)
- Eminere 3 (900mm / 3ft)
- Eminere 4 (1200mm / 4ft)
Housing
- Aluminium extruded body with die-casted end caps
- Tempered glass
Cooling system
- Convection
Total heat dissipation
- Eminere 1: 61 BTU/h (calculated)
- Eminere 2: 130 BTU/h (calculated)
- Eminere 3: 177 BTU/h (calculated)
- Eminere 4: 228 BTU/h (calculated)
Protection factor
- CE: IP 67
- US: Suitable for wet location
Impact rating
- CE: IK06
Operating ambient temperature range
- -20°C /+40°C (-4°F /+104°F
Operating temperature
- +67°C @ Ambient +40°C (+153°F @ Ambient +104°F)
Connection
- Input: panel connector Amphenol ABAB-DMQ06000021-IN (P/N13052952)
- Output: panel connector Amphenol ABAB-DAQ06000021 (P/N13052953) + water-tight cap
Weight
- Eminere 1: 2.5 kg (5.5 lbs)
- Eminere 2: 4 kg (8.82 lbs)
- Eminere 3: 6.02 kg (13.27 lbs)
- Eminere 4: 7.7 kg (17 lbs)
Dimensions (All dimensions in mm [inch])
Included items
- 1 x Eminere
- 1 x User manual
Optional accessories
CE Leader Cables FF:
Leader Cable FF 2m (P/N 13053438)
Leader Cable FF 5m (P/N 13053440)
Leader Cable FF 10m (P/N 13053436)
Leader Cable FF 25m (P/N 13053437)
Leader Cable FF 50m (P/N 13053439)
US Leader Cables FF:
Leader Cable FF 2m (P/N 13053433)
Leader Cable FF 5m (P/N 13053435)
Leader Cable FF 10m (P/N 13053431)
Leader Cable FF 25m (P/N 13053432)
Leader Cable FF 50m (P/N 13053434)
Jumper Cables FF/FM:
Jumper Cable FF/FM 0.25m (P/N 13053422)
Jumper Cable FF/FM 0.5m (P/N 13053423)
Jumper Cable FF/FM 1m (P/N 13053425)
Jumper Cable FF/FM 2m (P/N 13053427)
Jumper Cable FF/FM 3m (P/N 13053428)
Jumper Cable FF/FM 5m (P/N 13053430)
Jumper Cable FF/FM 10m (P/N 13053424)
Terminal KE 106, diameter 0.14mm (P/N 13053403)
Waterproof Cover Cap FM ZAHB-0006 (P/N 17031173)
Field Installable Connector FF (P/N 13053003)
Field Installable Connector FM (P/N 13053004)
C-clamp adaptors for Eminere (P/N 10980860)
E-boxes:
E-box Daisy (P/N 10063655)
E-box Daisy/W (P/N 10063638)
E-box Lite (P/N 10063657)
E-box Lite/W (P/N 10063653)
E-box Star (P/N 10063656)
E-box Star/W (P/N 10063644)
Booster box (P/N 10063712)
Shield for Eminere 1 RAL9011 (P/N 10980488)
Shield for Eminere 2 RAL9011 (P/N 10980489)
Shield for Eminere 3 RAL9011 (P/N 10980490)
Shield for Eminere 4 RAL9011 (P/N 10980491)
Cable Cover for Eminere 1 RAL9011 (P/N 10980484)
Cable Cover for Eminere 2 RAL9011 (P/N 10980485)
Cable Cover for Eminere 3 RAL9011 (P/N 10980486)
Cable Cover for Eminere 4 RAL9011 (P/N 10980487)
Mounting Brackets for Eminere 100mm, 2pcs RAL9011 (P/N 10980493)
Mounting Brackets for Eminere 200mm, 2pcs RAL9006 (P/N 10980529)
Mounting Brackets for Eminere 200mm, 2pcs RAL9011 (P/N 10980494)
Mounting Brackets for Eminere 300mm, 2pcs RAL9006 (P/N 10980576)
Mounting Brackets for Eminere 300mm, 2pcs RAL9011 (P/N 10980495)
Mounting Brackets for Eminere 50mm, 2pcs RAL9011 (P/N 10980525)
Cleaning and maintenance
DANGER !
Disconnect from the mains before starting any maintenance or cleaning
work
Rinse off loose dirt with low pressure water spray. Wash the housing with a
soft brush or sponge and a mild, nonabrasive washing detergent.
Rinse it. Maintenance and service operations are only to be carried out by a
qualified person.
Should you need any spare parts, please use ROBE OEM parts.
6.1 Disposing of the product
To preserve the environment please dispose or recycle this product at the end
of its life according to the local regulations and codes.
ChangeLog
This section summarizes changes in the user manual.
Version of manual | Date of issue | Description of changes |
---|---|---|
1.1 | 7/10/2019 | Inrush current added to chapter Technical Specifications |
1.2 | 25/11/2019 | Booster box added |
1.3 | 6/1/2020 | Electromagnetic emission information |
1.4 | 22/04/2020 | Technical specifications more specified |
1.5 | 18.05/2020 | Wiring of input/output connectors changed |
1.6 | 22/06/2020 | Voltage range change |
1.7 | 10/9/2020 | Booster box seal overview added |
1.8 | 16/12/2020 | New dimensions picture |
1.9 | 22/07/2021 | New accessories added |
2.0 | 19/08/2021 | Jumber cables changed in Optional accessories |
2.1 | 13/10/2021 | Technical specifications changed |
2.2 | 26/11/2021 | Optional accessories changed |
2.3 | 17/12/2021 | Jumper cable mounting added |
2.4 | 6/1/2022 | Jumper cable mounting changed |
2.5 | 12/1/2022 | Jumper cable mounting more specified |
2.6 | 7/2/2022 | Terminals 0,14 mm² (P/N 13053403) added |
2.7 | 23/02/2022 | Sealing circle added to jumper cable mounting |
2.8 | 19/05/2022 | QR code added |
2.9 | 8/1/2023 | Eminere update added |
3.0 | 10/2/2023 | DMX chart ver. 3.2 |
3.1 | 5/9/2023 | C-clamp adaptor installation added |
3.2 | 13/09/2023 | Jumper and leader cables numbers changed |
Specifications are subject to change without notice.
September 13, 2023
Copyright © 2019-2023 Robe Lighting – All rights reserved
Made in CZECH REPUBLIC by ROBE LIGHTING s.r.o. Palackeho 416/20 CZ 75701
Valasske Mezirici
DMX protocol
DMX protocol for: Eminere 1/2/3/4; Eminere Side 1/2/3/4;
Eminere Inground 2/4; Eminere Remote 1/2/3/4;
UVinere 2/4; UVinere Remote 1/2/4
Version: 3.2 (23 modes in total), software version 3.0 and higher|
Mode/Channels in all| Mode 1: RGBW(A)-8bit, Mode 2: RGB 8-bit, Mode 3:
full RGBW(A)|
1| 2| 3| 4| 5| 6| 7|
8-10| Mode 4: White-full control, Mode 5: Reduced RGBW(A)|
4| 3| 12| 3| 6| 8| 15| Reserved| Mode 6- Reduced RGBW(A)+white
control|
| | | | | | | | Mode 7- full RGBW(A)+virtual colour wheel|
| | | | | | | | RGBW(A) / RGB modes|
Mode/channels| DMX Value| Function| Type of control
1| 2| 3| 4| 5| 6| 7
–| –| –| –| –| –| 1| | Special
functions|
| | | | | | | 0| No function| step
| | | | | | | | To activate following functions , stop in DMX value for at
least 3 sec.|
| | | | | | | 1-2| Save current DMX values to fixture as initial DMX values.|
step
| | | | | | | 3-4| Show saved initial DMX values| step
| | | | | | | 5-6| Run factory demo sequences at switching fixture on (without
DMX)| step
| | | | | | | 7-255| Reserved|
1| 1| 1| –| 1| 1| 2| | Red|
| | | | | | | 0-255| Red LEDs saturation control (0-100%)| proportional
–| –| 2| –| –| –| 3| | Red Fine|
| | | | | | | 0-255| Red LEDs saturation control fine| proportional
2| 2| 3| –| 2| 2| 4| | Green|
| | | | | | | 0-255| Green LEDs saturation control (0-100%)| proportional
–| –| 4| –| –| –| 5| | Green Fine|
| | | | | | | 0-255| Green LEDs saturation control fine| proportional
3| 3| 5| –| 3| 3| 6| | Blue|
| | | | | | | 0-255| Blue LEDs saturation control (0-100%)| proportional
–| –| 6| –| –| –| 7| | Blue Fine|
| | | | | | | 0-255| Blue LEDs saturation control fine| proportional
4| –| 7| –| 4| 4| 8| | White (Amber)|
| | | | | | | 0-255| White LEDs saturation control (0-100%)| proportional
–| –| 8| –| –| –| 9| | White (Amber)
Fine|
| | | | | | | 0-255| White LEDs saturation control fine| proportional
–| –| 9| 1| –| 5| 10| | Green
correction|
| | | | | | | 0| Uncorrected white| step
| | | | | | | 1-127| Minus green –> uncorrected white| proportional
| | | | | | | 128| Uncorrected white (128=default)| step
| | | | | | | 129-255| Uncorrected white –> Plus green| proportional
–| –| 10| 2| –| 6| 11| | Colour
temperature correction (CTC)|
| | | | | | | 0| No function| step
| | | | | | | 1-10| Tungsten dimming 2700 K| step
| | | | | | | 11-20| Tungsten dimming 3200 K| step
| | | | | | | 21-255| Colour temperature changing from 1800 K –> 6500 K|
proportional
| | | | | | | | (21-1800K, 66-2700K, 91-3200K,141-4200K, 211- 600K,
255-6500K)|
–| –| –| –| –| –| 12| | Virtual Colour
Wheel|
| | | | | | | 0| No function| step
| Mode/channels| DMX Value| Function| Type of control
---|---|---|---|---
| 1| 2| 3| 4| 5| 6| 7
| | | | | | | | 1-2| White 1800 K| step
| | | | | | | | 3-4| White 2700 K| step
| | | | | | | | 5-6| White 3200 K| step
| | | | | | | | 7-8| White 4200 K| step
| | | | | | | | 9-10| White 5600 K| step
| | | | | | | | 11-12| White 6500 K| step
| | | | | | | | 13| Blue (Blue=full, Red+Green+White/Amber=0)| step
| | | | | | | | 14-23| Red=0, Green->up, Blue =full, White/Amber=0|
proportional
| | | | | | | | 24| Cyan (Red=0, Green=full, Blue =full, White/Amber=0)| step
| | | | | | | | 25-34| Red=0, Green=full, Blue->down, White/Amber=0|
proportional
| | | | | | | | 35| Green (Red=0, Green=full, Blue =0, White/Amber=0)| step
| | | | | | | | 36-45| Red->up, Green=full, Blue=0, White/Amber=0|
proportional
| | | | | | | | 46| Yellow (Red=full, Green=full, Blue=0, White/Amber=0)| step
| | | | | | | | 47-56| Red=full, Green->down, Blue=0, White/Amber=0|
proportional
| | | | | | | | 57| Red(Red=full, Green=0, Blue=0, White/Amber=0)| step
| | | | | | | | 58-67| Red=full, Green=0, Blue->up, White/Amber=0|
proportional
| | | | | | | | 68| Magenta (Red=full, Green=0, Blue=full, White/Amber=0)|
step
| | | | | | | | 69-78| Red -> down, Green=0, Blue=full, White/Amber=0|
proportional
| | | | | | | | 79| Blue (Red=0, Green=0, Blue=full, White/Amber=0)| step
| | | | | | | | | Transition effects|
| | | | | | | | 80-87| Rainbow effect (with fade time) from slow-> fast|
proportional
| | | | | | | | 88-95| Rainbow effect (without fade time) from slow-> fast|
proportional
| | | | | | | | 96-103| Full dynamic white (1800K->6500K->1800K) (with fade
time) from slow-> fast| proportional
| | | | | | | | 104-111| Full dynamic white (1800K->6500K->1800K) (without
fade time) from slow-> fast| proportional
| | | | | | | | 112-119| Dynamic warm white (1800K-3000K-1800K) (with fade
time) from slow-> fast| proportional
| | | | | | | | 120-127| Dynamic warm white (1800K-3000K-1800K) (without fade
time) from slow-> fast| proportional
| | | | | | | | 128-135| Rainbow effect + full dynamic white (with fade time)
from slow-> fast| proportional
| | | | | | | | 136-143| Rainbow effect + full dynamic white (without fade
time) from slow-> fast| proportional
| | | | | | | | 144-151| Blue/Green effect (with fade time) from slow-> fast|
proportional
| | | | | | | | 152-159| Blue/Green effect (without fade time) from slow->
fast| proportional
| | | | | | | | 160-167| Red/Blue effect (with fade time) from slow-> fast|
proportional
| | | | | | | | 168-175| Red/Blue effect (without fade time) from slow-> fast|
proportional
| | | | | | | | 176-183| Green/Red effect (with fade time) from slow-> fast|
proportional
| | | | | | | | 184-191| Green/Red effect (without fade time) from slow->
fast| proportional
| | | | | | | | 192-199| Blue/4000K effect (with fade time) from slow-> fast|
proportional
| | | | | | | | 200-207| Blue/4000K effect (without fade time) from slow->
fast| proportional
| | | | | | | | 208-215| Green/4000K effect (with fade time) from slow-> fast|
proportional
| | | | | | | | 216-223| Green/4000K effect (without fade time) from slow->
fast| proportional
| | | | | | | | 224-231| Red/4000K effect (with fade time) from slow-> fast|
proportional
| | | | | | | | 232-239| Red/4000K effect (without fade time) from slow->
fast| proportional
| | | | | | | | 240-255| Reserved|
| | | | | | | 13| | Shutter/Strobe|
| | | | | | | | 0-31| Shutter closed| step
| | | | | | | | 32-63| Shutter open| step
| | | | | | | | 64-95| Strobe-effect from slow to fast| proportional
| | | | | | | | 96-127| Shutter open| step
| | | | | | | | 128-143| Opening pulse in sequences from slow to fast|
proportional
| | | | | | | | 144-159| Closing pulse in sequences from fast to slow|
proportional
| | | | | | | | 160-191| Shutter open| step
| | | | | | | | 192-223| Random strobe-effect from slow to fast| proportional
| | | | | | | | 224-255| Shutter open| step
| –| –| 11| 3| 5| 7| 14| | Dimmer|
| | | | | | | | 0-255| Light intensity coarse (0-100%)| proportional
| –| –| 12| –| 6| 8| 15| | Dimmer Fine|
| | | | | | | | 0-255| Light intensity fine| proportional
| | | | | | | | | |
Copyright © 2022-2023 Robe Lighting s.r.o. – All rights reserved|
All Specifications subject to change without notice| |
| | | | | | | | |
DMX protocol for: Eminere 1/2/3/4; Eminere Side 1/2/3/4;
Eminere Inground 2/4; Eminere Remote 1/2/3/4;
UVinere 2/4; UVinere Remote 1/2/4
Version: 3.2 (23 modes in total)| | |
Mode/Channels in all| Mode 11: White selection, Mode 12: WW + CW|
11| 12| 13| 14-16| Mode 13: Only dimmer|
3| 4| 2| Reserved| Mode 13 is suitable for UVinere and UVinere Remote|
| | | | TW and PW modes|
Mode/channels| DMX Value| Function| Type of control
11| 12| 13
1| –| –| | White colour selection|
| | | 0 – 255| White from 2700 K – 6500 K| proportional
–| 1| –| | Warm White|
| | | 0 – 255| Warm White LEDs saturation control (0-100%)| proportional
–| 2| –| | Cool White|
| | | 0 – 255| Cool White LEDs saturation control (0-100%)| proportional
2| 3| 1| | Dimmer|
| | | 0 – 255| Light intensity coarse (0 – 100%)| proportional
3| 4| 2| | Dimmer Fine|
| | | 0 – 255| Light intensity fine| proportional
| | | | |
Copyright © 2022-2023 Robe Lighting s.r.o. – All rights reserved|
All Specifications subject to change without notice|
| | | | |
DMX protocol for: Eminere 1/2/3/4; Eminere Side 1/2/3/4;
Eminere Inground 2/4; Eminere Remote 1/2/3/4;
Version: 3.2 (23 modes in total)| | |
Mode/Channels in all| Mode 17: RGBW(A) pixels, Mode 18: RGB pixels,
Mode 19: TW pixels,
17| 18| 19| 20| 21-23| Mode 20: PW
dimmer pixels|
16| 12| 8| 8| Reserved| |
| | | | | Pixel modes|
Mode/channels| DMX
Value
| Function| Type of
control
17| 18| 19| 20
1| 1| –| –| | Red 1 -Eminere 1/2/3/4|
| | | | 0 – 255| Red LEDs saturation control (0-100%)| proportional
2| 2| –| –| | Green 1-Eminere 1/2/3/4|
| | | | 0 – 255| Green LEDs saturation control (0-100%)| proportional
3| 3| –| –| | Blue 1-Eminere 1/2/3/4|
| | | | 0 – 255| Blue LEDs saturation control (0-100%)| proportional
4| –| –| –| | White (Amber) 1-Eminere 1/2/3/4|
| | | | 0 – 255| White LEDs saturation control (0-100%)| proportional
5| 4| –| –| | Red 2 -Eminere 2/3/4|
| | | | 0 – 255| Red LEDs saturation control (0-100%)| proportional
6| 5| –| –| | Green 2-Eminere 2/3/4|
| | | | 0 – 255| Green LEDs saturation control (0-100%)| proportional
7| 6| –| –| | Blue 2-Eminere 2/3/4|
| | | | 0 – 255| Red LEDs saturation control (0-100%)| proportional
8| –| –| –| | White (Amber) 2-Eminere 2/3/4|
| | | | 0 – 255| White LEDs saturation control (0-100%)| proportional
9| 7| –| –| | Red 3-Eminere 3/4|
| | | | 0 – 255| Red LEDs saturation control (0-100%)| proportional
10| 8| –| –| | Green 3-Eminere 3/4|
| | | | 0 – 255| Green LEDs saturation control (0-100%)| proportional
11| 9| –| –| | Blue 3-Eminere 3/4|
| | | | 0 – 255| Blue LEDs saturation control (0-100%)| proportional
12| –| –| –| | White (Amber) 3-Eminere 3/4|
| | | | 0 – 255| White LEDs saturation control (0-100%)| proportional
13| 10| –| –| | Red 4-Eminere 4|
| | | | 0 – 255| Red LEDs saturation control (0-100%)| proportional
14| 11| –| –| | Green 4-Eminere 4|
| | | | 0 – 255| Green LEDs saturation control (0-100%)| proportional
15| 12| –| –| | Blue 4-Eminere 4|
| | | | 0 – 255| Blue LEDs saturation control (0-100%)| proportional
16| –| –| –| | White (Amber) 4 -Eminere 4|
| | | | 0 – 255| White LEDs saturation control (0-100%)| proportional
–| –| 1| –| | Warm White 1 -Eminere 1/2/3/4|
| | | | | Warm White LEDs saturation control (0-100%)| proportional
–| –| 2| –| | Cool White 1-Eminere 1/2/3/4|
| | | | 0 – 255| Cool White LEDs saturation control (0-100%)| proportional
–| –| 3| –| | Warm White 2-Eminere 2/3/4|
Mode/channels| DMX
Value
| Function| Type of
control
---|---|---|---
17| 18| 19| 20
| | | | 0 – 255| Warm White LEDs saturation control (0-100%)| proportional
–| –| 4| –| | Cool White 2-Eminere 2/3/4|
| | | | 0 – 255| Cool White LEDs saturation control (0-100%)| proportional
–| –| 5| –| | Warm White 3-Eminere 3/4|
| | | | 0 – 255| Warm White LEDs saturation control (0-100%)| proportional
–| –| 6| –| | Cool White 3-Eminere 3/4|
| | | | 0 – 255| Cool White LEDs saturation control (0-100%)| proportional
–| –| 7| –| | Warm White 4 -Eminere 4|
| | | | 0 – 255| Warm White LEDs saturation control (0-100%)| proportional
–| –| 8| –| | Cool White 4 -Eminere 4|
| | | | 0 – 255| Cool White LEDs saturation control (0-100%)| proportional
–| –| –| 1| | Dimmer 1|
| | | | 0 – 255| Light intensity coarse (0 – 100%)| proportional
–| –| –| 2| | Dimmer Fine 1|
| | | | 0 – 255| Light intensity fine| proportional
–| –| –| 3| | Dimmer 2|
| | | | 0 – 255| Light intensity coarse (0 – 100%)| proportional
–| –| –| 4| | Dimmer Fine 2|
| | | | 0 – 255| Light intensity fine| proportional
–| –| –| 5| | Dimmer 3|
| | | | 0 – 255| Light intensity coarse (0 – 100%)| proportional
–| –| –| 6| | Dimmer Fine 3|
| | | | 0 – 255| Light intensity fine| proportional
–| –| –| 7| | Dimmer 4|
| | | | 0 – 255| Light intensity coarse (0 – 100%)| proportional
–| –| –| 8| | Dimmer Fine 4|
| | | | 0 – 255| Light intensity fine| proportional
| | | | | |
Copyright © 2022-2023 Robe Lighting s.r.o. – All rights reserved|