SALTER 9113 Digital Glass Analyser Scale Instruction Manual
- June 14, 2024
- SALTER
Table of Contents
SALTER 9113 Digital Glass Analyser Scale
Safety Instructions
BATTERY WARNING : KEEP OUT OF THE REACH OF CHILDREN.
This product contains no user serviceable parts. Only a qualified electrician should attempt repairs. Do not place, store or use the product near direct sunlight or direct heat sources or in a damp/ high humidity environment. This product is a high precision device; handle it with care. This product is intended for domestic use only.
CAUTION : Do not use the analyser function if you have a pacemaker or other medical device fitted. If in doubt, consult your doctor.
Battery Safety
This product is supplied with 2 x AAA batteries. Only batteries of the same or
equivalent type as those recommended nshould be used with this product.
Batteries are to be inserted with the correct polarity. Exhausted batteries
should be removed from the product to avoid leakage.
Care and Maintenance
Wipe the exterior of the scale with a soft, damp cloth and allow it to dry thoroughly. Never immerse the scale in water or any other liquid. Do not use harsh or abrasive cleaning detergents or scourers to clean the scale, as this could cause damage.
Before First Use
Make sure the batteries are inserted following the correct polarity.
Position the scale on a firm flat surface. For use on carpet attach enclosed
carpet feet.
Setting the Body Analyser Scale to Zero
To turn on the scale, press the centre of the platform with your foot, making
sure that no weight is on the scale. [0.0/ZERO] will be displayed. To select a
weight unit (kg, st or lb), use the switch on the underside of the scale. The
scale will switch off and is now ready for use.
NOTE : The setup process must be repeated if the scale is moved. At all
other times step straight on the scale.
Using the Body Analyser Scale to take Weight Readings
STEP 1: Step on to the platform and stand still.
STEP 2: After 2-3 seconds the weight reading will be displayed.
STEP 3: Step off the platform; the weight reading will be displayed for
several seconds before the scale turns off.
Personal Data Entry
STEP 1: Press thebutton to turn the scale on.
STEP 2: While the user number is flashing, select a user number by
pressing the [>] or [ <] buttons. Press to confirm the user number.
STEP 3: The male or female symbol will flash. Press the [>] or [ <]
buttons to select male/female, then press to confirm.
STEP 4: The age display will flash. Press the [>] or [ <] buttons to
select the correct age, then pressto confirm.
STEP 5: The height display will flash. Press the [>] or [ <] buttons to
select the correct height, then press to confirm.
STEP 6: The athlete symbol will flash. Press the [>] or [ <] to turn
athlete mode on/off, then press to confirm.
STEP 7: The scale will display the settings then switch off. The memory
is set.
STEP 8: Repeat the above procedure to add a second user, or to change
user details.
NOTE : If age is set between 6-12 years, child mode will automatically be
selected. In child mode only weight, body fat and body water are displayed.
ATHLETE MODE: If the age is set between 15-50 years athlete mode is
available. An athlete is defined as a person who is involved in intense
physical activity of approximately 12 hours a week and who has a resting
heartbeat of approximately 60 beats per minute or less.
Using the Body Analyser Scale
This scale uses BIA (Bio Impedance Analysis) technology which passes a small
electrical impulse through the body to distinguish fat from lean tissue. The
electrical impulse cannot be felt and is perfectly safe. Contact with the body
is made via stainless steel pads on the glass platform. For more information
visit https://salter.com/understanding-your-measurements/
STEP 1: Position the scale on a flat, level surface. Press the ‘@’ button
to turn the scale on.
STEP 2: Select user number by using [>] or [ <l
STEP 3: The LCD display will show the saved data for that user, followed
by a zero reading.
STEP 4: With bare feet, step onto the platform and stand still. Make sure
your feet are evenly spaced on the platform.
STEP 5: After 2-3 seconds, the weight reading will be displayed.
STEP 6: Remain standing on the scale while the other readings are taken.
STEP 7: Your weight will be displayed followed by body fat%, body water%
and BMI.
Warning indicators
- Lo – Replace battery.
- 0-Ld – Weight exceeds maximum capacity.
- Err2 – Out of range, incorrect operation or poor feet contact.
Specifications
- Product code: GENANALYSER1
- Display: LCD
- Battery: 2 x 1.5 V AM batteries (included)
- Units: kg/st/lb
Disposal of Waste Batteries and Electrical and Electronic Equipment
This symbol on the product, its batteries or its .A packaging means that this product and any _ batteries it contains must not be disposed of with household waste. Instead, it is the user’s responsibility to hand this over to an applicable collection point for the recycling of batteries and electrical and electronic equipment. This separate collection and recycling will help to conserve natural resources and prevent potential negative consequences for human health and the environment due to the possible presence of hazardous substances in batteries and electrical and electronic equipment, which could be caused by inappropriate disposal. Some retailers provide take-back services which allow the user to return exhausted equipment for appropriate disposal. It is the user’s responsibility to delete any data on electrical and electronic equipment prior to disposal. For more information about where to drop batteries, electrical and electronic waste off, please contact the local city/municipality office, household waste disposal service, or the retailer.
If this product does not reach you in an acceptable condition, please contact our Customer Services Department at www.salter.com. Please have your delivery note to hand as details from it will be required. If you wish to return this product. please return it to the retailer from where it was purchased with your receipt (subject to their terms and conditions):To be eligible for the extended guarantee, go to guarantee.upgs.com/salter and register your product within 30 days of purchase.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>