WARNINGS
PRECAUTIONS
Do not open the speaker, do not try to disassemble it neither to modify it in any way. The system doesn’t include any user-repairable part.
If the system seems to be malfunctioning or damaged, stop using it at once and have it repaired by a NEXO qualified technician.
Do not expose the system directly to the sun or to the rain, do not immerse it into fluids, do not place objects filled with liquid on the system. If a liquid gets into the system, please have it inspected by a NEXO qualified technician.
When flying outdoor systems ensure that the system is not exposed to excessive wind or snow loads and is protected from rainfall.
In case of wind greater than 8 on Beaufort scale (72km/h – 45mph), a touring system has to be landed or an additional securing has to be implanted.
For fixed installations, wind loading has to be taken into account in accordance to the national standards
The connection should be performed by qualified technician, by ensuring that power is off.
Operating temperature with temperate climate: 0°C to +40°C (+32°F to +104); -20°C à +60°C (-4°F to +140°F) for storage.
SAFETY INFORMATIONS
Read this manual before using the speaker. Keep this manual available for further reference. Observe all warnings and cautions. Please check the NEXO Web site nexo-sa.com to get the most up-to-date version of this manual. Ensure you are aware of the safety rules applying to rigging, stacking or installing on tripod or speaker stand. Failure to observe these rules may expose persons to potential wounds or even death. Only use the system with accessories specified by NEXO.
Please always consult a NEXO-accredited technician if the installation needs architectural works and observe following precautions:
Mounting Precautions:
- Please select screws and mounting location supporting 4 times the system weight.
- Do not expose the system to excessive dust, vibrations, to extreme cold or hot temperatures, to reduce the risk of damaging components.
- Do not place the system in an unstable position: it could fall accidentally.
- If the system is used on a tripod, please ensure the tripod’s specifications are adapted and that its height does not exceed 1.40m/55”. Do not move the tripod with the system in position.
Connection and Powering Precautions:
- Unplug connected cables before moving the system.
- Power off the system before connecting the system.
- When switching on the installation, the amplifier must be powered last; when switching the installation off, shut off the amplifier first.
- If you work by cold temperatures, progressively raise the level to nominal value during the first minutes of use, to allow the system components to stabilize.
Please check regularly the system condition.
HIGH SOUND PRESSURE LEVELS
Exposure to very high sound pressure levels may cause permanent hearing losses. Degrees of hearing losses may be different from one person to another, but almost everybody will be affected if exposed to high sound pressure levels during a long period of time. The OSHA (Occupational Safety and Health Administration) American Agency specified the following maximal exposures:
Number of Hours | Sound Pressure Level (dBA), Slow Response |
---|---|
8 | 90 |
6 | 92 |
4 | 95 |
3 | 97 |
2 | 100 |
1 ½ | 102 |
1 | 105 |
½ | 110 |
¼ or less | 115 |
WASTE OF ELECTRIC OR ELECTRONIC EQUIPMENT
This symbol on the product or its packaging indicates that this product must not be treated as household waste. Instead, it is your responsibility to hand it over to a designated collection point for the recycling of waste electrical and electronic equipment. By ensuring your waste equipment is recycled, you will help prevent potential negative consequences for the environment and human health, which could appear if this product was not recycled. Recycling helps spare natural resources. For more information about the recycling of this product, please contact your local city office, your household waste disposal service or your reseller.
EQUIPMENT
On the four sides of the cabinet, two M10 fittings will connect the eLS400 to
accessories. (VNI-VCPL365, VNI-HCPL425, VNU-HBRK425, eye-bolts). 2 pairs
(In/Out) of 7.62 mm pitch screw terminal blocks. Cables from 0.75 mm2 to 3.31
mm2 (12 to 15 AWG) copper section.
eLS400 with IPCOV
DESCRIPTION
-
The eLS400 is a compact and powerful subwoofer, ideal complementing ePS6 and ePS8.
-
eLS400 is equipped with 2 pairs (In/Out) of screw terminal blocks, permissible cables from 0.75 mm2 to 3.31 mm2 (12 to 15 AWG) copper section. Cable with maximum outside diameter of 11mm. .
-
To wire eLS400, slit the membrane of the grommet crosswise, pass the cable through and make the connection to the screw terminals. Place the IPCOV.
-
IP55: be careful to place the IPCOV correctly.
-
Amplification
- The eLS400 speakers must be used with a NEXO processor to handle EQ, phase alignment, crossover and excursion/thermal protection for the system loudspeaker.
- The following table shows the number of ePS speakers and eLS400 subwoofers usable with each solution.
| DTD + DTDAMP4X0.7| DTD + DTDAMP4X1.3 **|
NXAMP4X1mk2 **| NXAMP4X2mk2 **| NXAMP4X4mk2 **
---|---|---|---|---|---
ePS6| Up to 2 per channel| Up to 2 per channel| Up to 4 per channel | Up to 4
per channel| Up to 4 per channel
ePS8| Up to 2 per channel| Up to 2 per channel| Up to 3 per channel | Up to 4
per channel| Up to 4 per channel
eLS400| 1 per channel| 1 per channel| Up to 2 per channel *| Up to 3 per
channel| Up to 3 per channel
PRESET
Please consult nexo-sa.com for NEXO TD Controllers firmware information.
For a traditional use of the subwoofer, there are 3 setups for eLS400:
- 45 Hz – 85 Hz
- 45 Hz – 120 Hz
- 45 Hz – 150 Hz
eLS400 + ePS6
eLS400 + ePS8
ACCESSORIES
WARNINGS
All accessories are specifically rated in agreement with structural computations. Never use other accessories when assembling eLS cabinets than the ones provided by NEXO: NEXO will decline responsibility if any component is purchased from different supplier.
PROHIBITED: ePS6 or ePS8 below eLS400 without dedicated accessory
VNU-HBRK425
Horizontal Cradle, can be used with VNI-CLADAPT.
VNU-HBRK425 (2 positions).
Remove the M10 inserts from each side.
Place HBRK425 on eLS400, use only fasteners provided. Tight properly.
Refer to the Product Data Sheet
VNI-CLADAPT
Ceiling Adapter, use with VNI-HBRK425.
Screw VNI-CLADAPT to the ceiling (fasteners not provided).
Place the assembly on VNI-CLADAPT, use the 2 guides. Tight with the fasteners provided with VNI-CLADAPT.
Refer to the Product Data Sheet
VNI-VCPL365
Coupler ePS6 under Vertical eLS400
Refer to the Product Data Sheet
VNI-HCPL425
Coupler ePS8 under Horizontal eLS400
Refer to the Product Data Sheet
ARRAY EQ
The ArrayEQ allows to adjust the system frequency response in its lower
range (see curves below, with different ArrayEq values):
MAINTENANCE
NOTE:
Speakers and Grills can be sent back to NEXO for recycling
Driver access
Loosen the 4 screws,
Remove the grille. Tightening torque: 2.5Nm
Remove 8 screws.
Tightening torque: 3.5Nm (Thread Locker: Loctite 242)
LF: red (+) / black (-)
Spare parts
MARK | QUANTITY | REFERENCE | DESIGNATION |
---|---|---|---|
1 | 1 | 05ELS400-UA | Complete grille Black |
2 | 1 | 05EBELS400 | Cabinet Black |
3 | 8 | 05VXTSTHC1012 | HEADLESS Screw M10x12 Black (x10) |
4 | 1 | 05HPB12ND | HP BASS 12″ (6 ohms) |
1 | 05N12ND-4R/K | HPB12ND RECONE KIT | |
5 | 1 | 05LOGNEXO6 | NEXO LOGO + STARLOCK WASHER |
6 | 2 | 05PASF-DG9E1 | Grommet DG11 Ø15.5MM |
TECHNICAL SPECIFICATIONS
WITH NEXO ELECTRONICS
Model | eLS400 |
---|---|
Frequency range (±6dB) | 45 Hz – 150 Hz |
Peak SPL Level (1m) | 130dB Peak |
Operating voltage | 35 Vrms |
Crossover Frequency | 45 – 85 Hz; 45 – 120 Hz; 45 – 120 Hz |
Nominal Impedance | 6 ohms |
SPECIFICATIONS
Model | eLS400 |
---|---|
Components | LF: 1×12” – Long excursion Neodymium driver |
Material | Baltic birch plywood 15mm |
Finish | Black structural paint (RAL9005 or Custom RAL upon request) |
Front finish | Black acoustic fabric fitted front steel front grille |
Fittings | 2x M10 on each side for rigging accessories. |
**Connector** | 2 pairs (In/Out) of 7.62 mm pitch screw terminal blocks. |
Cables from 0.75 mm2 to 3.31 mm2 (12 to 15 AWG) copper section. Cable with
maximum outside diameter of 11 mm.
Weight| 14.5 kg / 32 lb
IP Classification| IP55 with IPCOV
Dimensions|