Product Information
EU Conformity declaration
We, NEXO SA
ZA DU PRE DE LA DAME JEANNE
60128 PLAILLY – France
Declare under our sole responsibility that the product Loudspeaker
Type GEOM6
Serial number On the product
Is in conformity with the provisions of the following directive including all
applicable amendments: 2014/35/UE (Low Voltage Directive)
Applied rules and standards: EN 12100, EN 13155, EN 62368
Plailly, June, 2014 Joseph CARCOPINO, R&D Director
Specifications
- Product Type: Loudspeaker GEOM6
- Serial Number: DP4306-01b-DI
- Conformity: EU Conformity declaration – Directive 2014/35/UE (Low Voltage Directive)
- Applied Rules and Standards: EN 12100, EN 13155, EN 62368
Warnings and Precautions
- Select screws and mounting locations that can support 4 times the system weight.
- Avoid exposing the system to excessive dust, vibrations, extreme cold or hot temperatures to prevent damage to components.
- Ensure the system is placed in a stable position to prevent accidental falls.
- If using the system on a tripod, ensure the tripod’s specifications are suitable and its height does not exceed 1.40m/55. Do not move the tripod with the system in position.
- Before moving the system, unplug connected cables and power it off.
- When switching on or off the installation, power off/on the amplifier last/first.
- If working in cold temperatures, gradually raise the level to nominal value during the first minutes of use to allow system components to stabilize.
- Regularly check the system condition.
- Do not open the speaker, do not try to disassemble it neither to modify it in any way. The system doesn’t include any user-repairable part.
- If the system seems to be malfunctioning or damaged, stop using it at once and have it repaired by a NEXO qualified technician.
- Do not expose the system directly to the sun or to the rain, do not immerse it into fluids, do not place objects filled with liquid on the system. If a liquid gets into the system, please have it inspected by a NEXO qualified technician.
- When flying outdoor systems ensure that the system is not exposed to excessive wind or snow loads and is protected from rainfall.
- In case of wind greater than 8 on Beaufort scale (72km/h – 45mph), a touring system has to be landed or an additional securing has to be implanted.
- For fixed installations, wind loading has to be taken into account in accordance to the national standards The connection should be performed by qualified technician, by ensuring that power is off.
- Operating temperature with temperate climate: 0°C to +40°C (+32°F to +104); -20°C à +60°C (-4°F to +140°F) for storage.
SAFETY INFORMATIONS
Read this manual before using the speaker. Keep this manual available for further reference. Observe all warnings and cautions. Please check the NEXO Web site nexo-sa.com to get the most up-to-date version of this manual. Ensure you are aware of the safety rules applying to rigging, stacking or installing on tripod or speaker stand. Failure to observe these rules may expose persons to potential wounds or even death. Only use the system with accessories specified by NEXO. Please always consult a NEXO- accredited technician if the installation needs architectural works and observe following precautions:
Mounting Precautions:
- Please select screws and mounting location supporting 4 times the system weight.
- Do not expose the system to excessive dust, vibrations, to extreme cold or hot temperatures, to reduce the risk of damaging components.
- Do not place the system in an unstable position: it could fall accidentally.
- If the system is used on a tripod, please ensure the tripod’s specifications are adapted and that its height does not exceed 1.40m/55”. Do not move the tripod with the system in position.
Connection and Powering Precautions:
- Unplug connected cables before moving the system.
- Power off the system before connecting the system.
- When switching on the installation, the amplifier must be powered last; when switching the installation off, shut off the amplifier first.
- If you work by cold temperatures, progressively raise the level to nominal value during the first minutes of use, to allow the system components to stabilize.
Please check regularly the system condition.
HIGH SOUND PRESSURE LEVELS
Exposure to very high sound pressure levels may cause permanent hearing
losses. Degrees of hearing losses may be different from one person to another,
but almost everybody will be affected if exposed to high sound pressure levels
during a long period of time. The OSHA (Occupational Safety and Health
Administration) American Agency specified the following maximal exposures:
Number of Hours | Sound Pressure Level (dBA), Slow Response |
---|---|
8 | 90 |
6 | 92 |
4 | 95 |
3 | 97 |
2 | 100 |
1 ½ | 102 |
1 | 105 |
½ | 110 |
¼ or less | 115 |
WASTE OF ELECTRIC OR ELECTRONIC EQUIPMENT
- This symbol on the product or its packaging indicates that this product must not be treated as household waste. Instead, it is your responsibility to hand it over to a designated collection point for the recycling of waste electrical and electronic equipment. By ensuring your waste equipment is recycled, you will help prevent potential negative consequences for the environment and human health, which could appear if this product was not recycled. Recycling helps spare natural resources. For more information about the recycling of this product, please contact your local city office, your household waste disposal service or your reseller.
High Sound Pressure Levels
Exposure to very high sound pressure levels may cause permanent hearing
losses. The OSHA (Occupational Safety and Health Administration) specifies the
following maximal exposures:
Number of Hours | Sound Pressure Level (dBA), Slow Response |
---|---|
90 | 92 |
95 | 97 |
100 | 102 |
105 | 110 |
115
Description **
**
The GEOM6 is a loudspeaker that can be stacked or flown with the HF waveguide exit on the left or right side of the front panel. This allows you to broaden or narrow the stereo image depending on your needs and the characteristics of the venue. It is recommended to build a system with the HF waveguide on the outside of each assembly for a larger stereo image.
- GEOM620 and GEOM6B are a mid-size line array. GEOM620 is a 2 ways passive, with a 6.5’’ LF and a 1’’ HF; GEOM6B is a bass extension with a 6.5” driver. With GEOM620, you can change the HF horizontal directivity from 80° to 120° by adding a pair of flanges.
- The GEOM6 can be stacked of flown with the HF waveguide exit on the left or the right side of the front panel, allowing to broaden or narrow the stereo image depending on your need and the characteristics of the venue. We recommend to build system with the HF waveguide on the outside of each assembly (larger stereo image).
- Versions:
- GEOM620: Touring or fix application; Black
- GEOM620-PW: Touring or fix application; White
- GEOM6B: Touring or fix application; Black
- GEOM6-PW: Touring or fix application; White
- Connectors:
- GEOM620/6B: two NL4 connectors, the 4 pins of the 2 sockets are connected in parallel within the enclosure.
- GEOM620: 2+/2-.
- GEOM6B: 1+/1-
- Amplification:
- The GEOM6 cabinets MUST be used with a NEXO processor to handle EQ, phase alignment, crossover and excursion/thermal protection for the system loudspeakers.
- The following table shows the number of GEOM6 speakers and MSUB12 subwoofers usable with each solution.
| DTD + DTDAMP4x0.7| DTD + DTDAMP4x1.3|
NXAMP4x1MK2| NXAMP4x2MK2| NXAMP4x4MK2
---|---|---|---|---|---
GEOM620| Up to 2 per channel| Up to 2 per channel| Up to 3 per channel| Up to
4 per channel| Up to 4 per channel
GEOM6B| Up to 2 per channel| Up to 2 per channel| Up to 3 per channel| Up to 4
per channel| Up to 4 per channel
MSUB12| 1 per channel| 1 per channel| Up to 2 per channel| Up to 3 per
channel| Up to 3 per channel
| | | Recommended| |
Model| GEOM620| GEOM6B| MSUB12
---|---|---|---
DTD + DTDAMP4x0.7| Up to 2 per channel| Up to 2 per channel| 1 per channel
DTD + DTDAMP4x1.3| Up to 2 per channel| Up to 2 per channel| 1 per channel
NXAMP4x1MK2| Up to 3 per channel| Up to 3 per channel| Up to 2 per channel
NXAMP4x2MK2| Up to 4 per channel| Up to 4 per channel| Up to 3 per channel
NXAMP4x4MK2| Up to 4 per channel| Up to 4 per channel| Up to 3 per channel
Please consult nexo-sa.com for NEXO TD Controllers
firmware information.
For the GEOM620 or GEOM6B, with or without directivity flanges, the following
setups are available: Passive Mode
- Setup for one stand-alone box, with high-pass at 50, 60, 75, 85, 95 or 120 Hz.
- Setup for arrays from 2 to 3 boxes, with high-pass at 50, 60, 75, 85, 95 or 120 Hz.
- Setup for arrays from 4 to 6 boxes, with high-pass at 50, 60, 75, 85, 95 or 120 Hz.
- Setup for arrays from 7 to 12 boxes, with high-pass at 50, 60, 75, 85, 95 or 120Hz.
- Setup for Stack Monitor, with high-pass at 50, 60 or 75 Hz.
Default Cross over on one box 50 Hz Front Fill, multi-diff, sound reinforcement all short throw application; High SPL Small system using 2x GEOM6 and 2x MSUB12 in 85 Hz;
For small flying or stacking configuration, mid throw application used at 60 Hz without MSUB12 and 85 Hz with set up 50-85 Hz for MSUB12.
For stack configuration using MSUB12 in OMNI or CARDIO mode with 1 Back and 2 Front and GEOM6 on top of them, MSUB12 should use the 50-85 Hz setup (85 Hz crossover should be used for GEOM6 as well). A small overlap could have impact if needed, for example use MSUB12 with 50-120 Hz setup.
For long throw flying application used in GEOM6 at 60 Hz without Sub. MSUB12 should use the 50-120 Hz setup (120 Hz crossover should be used for GEOM6 as well). If a larger stacked Sub is used all together, MSUB12 should use the 63-120 Hz setup.
For very long throw application, MSUB12 should be deployed using the 50-120 Hz setup (120 Hz crossover should be used for GEOM6). Don’t forget to put HF Waveguide either to the exterior or the interior of the venue.
Ground Stack Sub design
Assembly
Front
Insert quick release pins 5x15mm (VXT-BL515) on both sides (or use GMI-BNFIX).
Back
Adjust the angle with the lift bar and lock with the quick release pin VXT-
BL515 (or fasteners provided with GMI-BNFIX).
WARNINGS All GEOM6 accessories are specifically rated in agreement with structural computations. Never use other accessories – including push-pins – when assembling GEOM6 cabinets than the ones provided by NEXO: NEXO will decline responsibility over the entire GEOM6 accessory range if any component is purchased from different supplier. All GEOM6 accessories have been designed so that cabinet are arrayed vertically. GEOM6 horizontal assemblies as shown in figure below are UNSAFE and STRICTLY PROHIBITED
VNT-BUMPM6
Rated for a maximum of 12 GEOM6 or 8 MSUB12, or a combination with a maximum
of 4 MSUB12 and 6 GEOM6. Flown on 1 or 2 rigging points. Usable with VNT-
EXBARM6 for extra tilt angle and flown on one or two rigging points. 1
location for laser/clinometer. Use VXT-BL615 or VNI-FIXBUMPM6 with MSUB12. Use
VXT-BL515 or GMI-BNFIX with GEOM6.
Refer to the Product Data Sheet
VNT-EXBARM6
Extension bar for VNT-BUMPM6
Refer to the Product Data Sheet
VNT-MNSTKM6
Stacking option for GEOM6 on top of MSUB12 (with GMT-BUMPER).
Refer to the Product Data Sheet
VNT-TCBRK3551
Rotary Truss Clamp
Place VNT-TCBRK3551 on GMT-BUMPER, VNT-BUMPM6 or VNT-EXBARM6 at the desired hole.
Refer to the Product Data Sheet
GEOM6 – ACCESSORIES
GMT-BUMPER
Rated for a maximum of 12 GEOM6. Usable with GMT-EXBAR for a one rigging
point. Stacking alone, rated for a maximum of 3x GEOM6.
Refer to the Product Data Sheet
GMT-LBUMP
Rated for a maximum of 3 GEOM6.
Refer to the Product Data Sheet
GMT-EXBAR
Rated for a maximum of 12 GEOM6. Usable with GMT-BUMPER
Refer to the Product Data Sheet
GMT-LBPADPT
Use with GMT-LBUMP Rated for a maximum of 3 GEOM6
Refer to the Product Data Sheet
GMT-BPADPT-2
Use with GMT-BUMP for stacking.
Refer to the Product Data Sheet
GMT-FLG
Pair of flanges for 120°horizontal directivity.
Refer to the Product Data Sheet
VXT-BL515
Quick release pin 5x15mm for touring application.
GMI-BNFIX
Rigging fix.
Refer to the Product Data Sheet
Refer to the Product Data Sheet
GMI-IPCOV
IP54 connector box
Refer to the Product Data Sheet
VNI-WS15
Wall bracket, use with GMT-LBUMP (3 GEOM6 max)
Refer to the Product Data Sheet
VNI-LNKM61018
Adapter MSUB18-I to GEOM6 (with GMI-BNFIX). Max 6x GEOM6
Refer to the Product Data Sheet
VNT-TCBRK
Truss clamp adapter
Refer to the Product Data Sheet
VNT-XHBRK
Lifting ring
Refer to the Product Data Sheet
VNT-POLE
Pole mount adapter Max 3x GEOM6
Refer to the Product Data Sheet
GMT-6CASE
Use for 6x GEOM6 and accessories Refer to the Product Data Sheet
ARRAY EQ
The ArrayEQ allows to adjust the system frequency response in its lower range (see curves below, with different ArrayEq values):
MAINTENANCE
Front panel disassembly
- Remove the grid (2 screws Tx25).
- Remove external 120° flange (2 screws Tx20).
- Remove the front cabinet (6 screws Tx25).
- Remove 4 screws Tx25 to access to the speaker. Tightening torque: 3,5 Nm
- Remove 3 nuts (Hex10) to access to the speaker.
- Remove 4 screws (Allen 3), remove the cover and access to the diaphragm.
Spare parts
MARK | QUANTITY | REFERENCE | DESIGNATION |
---|---|---|---|
1 | 1 | 05GEO-6UA | Complete grille black with logo and screws |
1 | 05GEO-6UAPW | Complete grille white with logo and screws | |
1a | 1 | 05LOGNEXO6 | Logo + Starlocks |
2 | 1 | 05HPADE14-16 | HF driver complete (with screws) |
1 | 05NH14-16R/k | HF diaphragm HPADE14-16 | |
3 | 1 | HPB6-F | 6.5” driver |
1 | 05HPB6-FR/K | Recone kit HPB6-F | |
4 | 1 | 05LEXWARM6 | Lexan warning |
5 | 1 | 05GEOM6LKB | LinkBar |
6 | 2 | 05LEXRIGM6AG | Lexan angle |
7 | 1 | 05GEOM620-FPA | Connecting plate |
8 | 1 | 05LEXCNX620 | Lexan GEOM620 |
1 | 05LEXCNX6B | Lexan GEOM6B | |
9 | 1 | 04VXT-BL515 | Quick release pin 5×15 |
NOTE:
Speakers and Grills can be sent back to NEXO for recycling
TECHNICAL SPECIFICATIONS
GEOM620 WITH NEXO ELECTRONICS
Model | GEOM620 |
---|---|
Frequency range (±6dB) | 75Hz – 20kHz |
Sensibility (1W / 1m) | 95dB SPL Nominal |
Peak SPL Level (1m) | 128dB |
Operating voltage | 30 Vrms |
Vertical Dispersion | 20° |
Horizontal Dispersion | 80° or 120° (with flanges GMT-FLG) |
Crossover Frequency | LF-HF: 2kHz Passive |
Nominal Impedance | Ω |
Recommended Amplification | 450 W per cabinet |
SPECIFICATIONS
Model | GEOM620 |
---|---|
Components | LF: 1x 6.5’’ – 8 Ω – Long excursion |
HF: 1×1” throat driver on a BEA/FEA optimized HRWTM
Material| Lightweight polyurethane composite
Finish| Black or white structural paint
**Front finish| Steel front grille Black or white paint Black or white
mesh
Fittings| 2 Side handles
Connector| 2x NL4 connectors, 4 poles connectors
Weight| 9.7 kg – 21.4 lb
****Dimensions**|
GEOM6B WITH NEXO ELECTRONICS
Model | GEOM6B |
---|---|
Frequency range (±6dB) | 70Hz – 1kHz |
Sensibility (1W / 1m) | 94dB SPL Nominal |
Peak SPL Level (1m) | 125dB |
Operating voltage | 30 Vrms |
Nominal Impedance | Ω |
Recommended Amplification | 450 W per cabinet |
SPECIFICATIONS
Model | GEOM6B |
---|---|
Components | LF: 1x 6.5’’ – 8Ω – Long excursion |
Material | Lightweight polyurethane composite |
Finish | Black or white structural paint |
**Front finish** | Steel front grille Black or white paint Black or white |
mesh
Fittings| 2 Side handles
Connector| 2x NL4 connectors, 4 poles connectors
Weight| 7.6 kg – 13.8 lb
**Dimensions| **
Preset GEOM6
For the GEOM620 or GEOM6B, with or without directivity flanges, the
following setups are available:
- Passive Mode – 1 Box: Default crossover on one box at 50 Hz. Suitable for front fill, multi-diff, sound reinforcement, and short throw applications.
- High SPL Small System: Uses 2x GEOM6 and 2x MSUB12 in an 85 Hz setup.
FAQ
Q: Where can I find firmware information for NEXO TD Controllers?
A: Please consult nexo-sa.com for NEXO TD
Controllers firmware information.
NEXO S.A.
F-60128 PLAILLY
Tel: +33 3 44 99 00 70
Fax: +33 3 44 99 00 30
E-mail: info@nexo.fr
nexo-sa.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>