Conrad LC400TFX Power Supply PC Monitor Instructions
- June 14, 2024
- CONRAD
Table of Contents
Conrad LC400TFX Power Supply PC Monitor
Product Information
Specifications
- Power Supply: PC Monitor
- Software: PC Software
- Driver: CH340 Driver
Product Usage Instructions
Install Driver
- Click to unzip driver.zip.
- Double-click USB-SERIAL_Install_Windows_Vx_x to decompress the driver package.
- Install the CH340 driver by following the on-screen instructions.
Software Operation
- Click to unzip PC software.zip.
- Open the exe file by double-clicking the right mouse button and save the other files.
- The initialization screen will be displayed.
How to Connect
- Click “Comm Setting” from the left-top Menu bar to display the serial port parameter setting screen.
- Set the serial port number by selecting a COM number corresponding to the COM number of USB-SERIAL CH340 from the drop-down list. Leave other parameters as default.
- Click “Open” to complete the connection with the computer.
Interface Guide
The interface consists of various areas and quick keys:
- Menu Bar Quick key
- Displays the power Mode output duration
- Voltage/Current Wave Area
- Channel Status Area
- Actual output display Area
- Output OVP/OCP/OTP warning area
- Quick Set Area
- Model information bar
- List waveform editing function area
- Channel Switch
- Set values
- Limit
- Voltage/Current waveform Area
- Voltage ripple
- Waveform display area
- Current ripple
- Coordinate waveform output setting key
- Clear key
List Waveform Editing Area
- Click in the upper left corner or directly click “edit” in the List waveform editing area.
- Input the required voltage, current, time, and Y/N after the serial number in the table (unchangeable).
- Set the number of data groups (1-100).
- Parameter setting: Enter the required parameters in the parameter editing box and press Enter to complete the parameter setting.
- Set the start group number, end group number, and period for data output in sequence.
- Click “Start” to output data in sequence.
- Click “Stop” to stop data output.
Quick Set Area
We can set 8 groups of common values (M1-M8) for subsequent direct calls.
To set the parameter:
- Click after M1 to select it.
- In U/I/OVP/OCP, input the required voltage/current/output overvoltage/output overcurrent values.
- Repeat the above steps for up to 8 groups of values.
FAQ
-
Q: Where can I acquire the PC software and relative files?
A: Please refer to our official website to download the PC software, driver, and software installation guide -
Q: How do I check the COM number and driver in Device Manager?
A: Go back to the computer and click Device Manager to check the COM number and driver.
Power Supply PC Monitor Software Instruction
- Please refer to our official website to acquire PC software and relative files, including PC software, driver and software installation guide.
Install Driver
- Click to unzip “driver. zip”, double-click USB-SERIAL_Install_Windows_Vx_x ,decompress the serial port Chip Driver package and install the CH340 driver:
- Click Install, wait for the installation to complete, click OK, as shown below:
- Go back to the computer and click Device Manager to check the COM number and driver, as shown below :
Software Operation
- Click to unzip “PC software .zip”, double-click the right mouse button to open the “exe” file, save the other files. The initialization screen is displayed, as shown in the following figure.
How to connect
- Click “comm Setting” from left-top Menu bar, the serial port parameter setting screen is displayed.
- Set the serial port number, click the drop-down list, and select a COM number corresponding to the COM number of “USB-SERIAL CH340”. Other parameters are the default values.
- Click “Open” to complete the connection with the computer.
Interface Guide
Channel Status Area
- Parameter setting: Enter the required parameters in the parameter editing box and press Enter to complete the parameter setting.
Voltage/Current waveform Area
- When the channel is open, the Voltage/Current curve of the channel can be observed in the waveform area.
- Coordinate
- Click the “Coordinate” setting in the voltage/Current waveform display area to jump out of the setting interface and select the adaptive mode or manually enter the numerical mode.
- Adaption mode
- Click ” ” next to electric pressure shaft adaptive and current adaptive, and the state is “ “. Click “OK” to realize the adaptive mode.
Manually enter a numerical mode
- Enter the desired coordinates and click” OK” to confirm the input.
List waveform editing Area
- Click in the upper left corner or directly click “edit” in the List waveform editing area. Input the required voltage, current, time, and Y/N after the serial number in the table (unchangeable) (when set to Y, the data is normally output; when set to N, the data is not output). The number of data groups can be set to 1-100;
- Parameter setting: Enter the required parameters in the parameter editing box and press “Enter” to complete the parameter setting.
- Set the start group number, end group number, and period for data output in sequence. Click “Start” to output data in sequence.
- Click “Stop” to stop data output.
Quick Set Area
- We can set 8 groups of common values (M1-M8) by ourselves, which is convenient for subsequent direct calls.
Set the parameter
- Let’s take setting the M1 parameter as an example:
- Click after M1 to make it the selected state . In U/I/OVP/OCP, input the required voltage/current/output overvoltage/output overcurrent values, and so on, up to 8 groups of values can be input.
Call the numerical
- Let’s take setting the M1 parameter as an example:
- Click after M1 to make it the selected state , Click the “Call” in the upper right corner of the quick setting area to quickly deliver the four parameters U/I/OVP/OCP to the power supply.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>