eldes EWP-EXT Low Consumption Universal Wireless Triple Technology Detector Instruction Manual

June 4, 2024
eldes

eldes EWP-EXT Low Consumption Universal Wireless Triple Technology

Detector

Features

Installation on the wall Coverage 15 m, angolo 90°
Frequency microwave 10.525 GHz
Alarm technology DSP(Digital Signal Processing)
Detecting distance From 5 to 15 m
Detection areas 8 zones for every detector
Installation height 0,8-1,4 m (suggested 1m) 2,1 m (with braket)
Detecting mode Selectable: AND or triple AND
Power supply 3-10 Vdc
Protection polarity inversion Yes
Low battery display Yes, via led, minumum 2,7 V (tipical)
Stand by consumption < 12 uA
Max consumption 35 mA
Alarm contact NC-NO 50mA
Microwave setting Trimmer
Alarm time 2 s

Displaing Led

| Blue: alarm

Red: IR up and down Yellow: Microwave

Detection Speed| Between 0.2 and 3 m/s
RFI/EMI Immunity| 10 V/m tra 0.1MHz-2 GHz
Light Immunity| >10000 Lux
Tamper| NC-NO 100 mA
Programming| By dip Switch
Working temperature| Da -20°C a +60° C
IP Protection| IP54
Autocompesation IR| Yes, both
Warm up time| 60 s
Inhibition time| 3 minutes

Item description

eldes-EWP-EXT-Low-Consumption-Universal-Wireless-Triple-Technology-Detector-
fig-1

Triple technology outdoor detector made with double infrared sensor and microwave. Adjustment of microwave flow by trimmer placed inside. Height adjustment of the lower PIR sensor to perfectly adjust the flow and reduce false alarms, with three angles of inclination A – B – C. Immune to animals weighing less than 20 kg and height less than 80 cm if placed in AND and installed at 1 m height

Coverage diagram

eldes-EWP-EXT-Low-Consumption-Universal-Wireless-Triple-Technology-Detector-
fig-2 eldes-
EWP-EXT-Low-Consumption-Universal-Wireless-Triple-Technology-Detector-
fig-3 eldes-
EWP-EXT-Low-Consumption-Universal-Wireless-Triple-Technology-Detector-
fig-4

Detections

AND configuration (3AND) pos. 15m

eldes-EWP-EXT-Low-Consumption-Universal-Wireless-Triple-Technology-Detector-
fig-5

AND configuration (3AND) pos. 10m

eldes-EWP-EXT-Low-Consumption-Universal-Wireless-Triple-Technology-Detector-
fig-6

AND configuration (3AND) pos. 5m

eldes-EWP-EXT-Low-Consumption-Universal-Wireless-Triple-Technology-Detector-
fig-7

Installation

For a correct functioning of the triple technology detector it is necessary to know that:

  • The microwave is sensitive to any movement, never point the detector towards hedges or tree fronds. Adjust the flow rate appropriately.
  • Metal surfaces reflect the microwave by changing its flow rate.
  • The two passive infrared sensors are sensitive to sudden thermal variations. Avoid pointing the detector directed towards the sun. In the presence of animals, adjust the detection angle appropriately and always use the triple AND (3AND) condition.
  • The detector at the first power supply has a stabilization time of about 1 minute.

Plugs

  • Plugs AS/C-NC-NO : Tamper. Connect C-NC for normally close, connect C-NO for normally open.
  • Plugs AL/C-NC-NO : Alarm. Connect C-NC for normally close, connect C-NO for normally open.
  • Plugs + – : Power supply. Connect the battery (3/10V)
    Fix the case for wireless transmitter to the wall or to the bracket, connect the wires of the alarm input and of the tamper to the wireless transmitter and make them pass through the appropriate hole. Close the case with the appropriate screws. Remove the IR and microwave sensor block (4 screws) from the detector’s case and drill a hole for passing cables. Fix the detector on the case for wireless transmitter. Reassemble the sensor block. Connect the battery connectors. Perform the coverage tests.

Settings

By default the setting DIP are setting as shown.

DIP1  Low battery display (SGN BAT)

  • ON If the battery has a voltage lower than 2.7 V, the yellow LED flashes rapidly every 2 s (approx.). During the walk test this signal is interrupted
  • OFF No displaying

DIP2 Triple AND (3AND)

  • ON Detection in triple and is enabled. To generate an alarm, the two pyroelectric devices and the microwave must detect an intrusion at the same time. Recommended in the presence of animals.
  • OFF  Detection in triple and disabled. To generate an alarm it is sufficient that one of the two pyroelectrics and the microwave detect an intrusion at the same time. Use only in stable and animal-free environments.

DIP3  Alarm Led (LD AL STBY)

  • ON The device displays intrusion on the LEDs even during low consumption operation. Only the central blue LED lights up to signal the intrusion
  • OFF  The device does not display intrusion on the LEDs during low-power operation. No LED lights up.

DIP4  Working Test/coverage (WALK TEST)

OFF→ON An OFF ON transition on this dip allows you to perform the time and/or coverage test. Once the period of time has elapsed, the device returns to the set-up of consumption even in ON. To reactivate the test, set the dip switch to OFF and, after a few seconds, set it to ON. The entry and exit from the trial period is signaled by the simultaneous flashing of the three LEDs.

Signaling LED

The following table summarizes the meaning of the LEDs during the walk test and the low consumption operation.

LED Walk test Low consumption
Red One of the two pyroelectric
detects intrusion No signaling
Yellow Flashing during movements, steady on if microwave alarm is
reached Short flash every 2 s (approx.) If active low battery warning (DIP1)

and if battery

below threshold

Blue| Intrusion alarm on steady| Intrusion alarm if DIP3 activated otherwise no signaling

Working test and setting

Portare il Dip 4 da OFF a ON, controllare e regolare l’area di copertura. Muoversi all’interno dell’area da proteggere verificando l’accensione dei LED. Poiché il led rosso è condiviso da entrambi i piroelettrici, si suggerisce, per regolare la portata IR, di regolare al massimo il trimmer della microonda (RANGE MW), disattivare la funzione 3AND (DIP2), azzerare il trimmer del piroelettrico basso (IR-L) e regolare il trimmer del piroelettrico alto (IR-H) osservando il led rosso. Una volta terminato, attivare la funzione 3AND (DIP2) e regolare altezza e trimmer IR-L osservando il led blu di allarme. Infine regolare il trimmer della portata microonda (RANGE MW).

Inhibition time

Between two alarm detections there is an inhibition time of about three minutes in which the sensor does not open the alarm contact. If during this time the sensor detects a further movement, the inhibition time is reset and starts again from zero.

Installation suggest

eldes-EWP-EXT-Low-Consumption-Universal-Wireless-Triple-Technology-Detector-
fig-10

N.B. In the presence of hedges or bushes that can generate false alarms, use the supplied beam cover lens, covering the beams of the infrared to avoid it as shown in picture.