INSTALLATION
GENERAL OPERATIONAL DESCRIPTION
MAIN FEATURES:
- 4 zone terminals.
- 2 open-collector outputs.
- 2 10kΩ NTC/PT1000 temperature sensor inputs.
- Battery or externally-powered.
- Compatible with any third-party wired sensor or siren.
EW2 is a wireless device intended to expand ELDES alarm system capabilities by
providing wireless connection access to any third-party wired devices. EW2
comes quipped with 4 zone terminals designed for wired digital sensor
connection, such as magnetic door contact, motion detector etc. In addition,
the 2 open-collector outputs on board allow to connect any wired siren as well
as to connect and control any electrical appliance, such as gates, lights,
watering etc. EW2 also features 2 inputs for 10kΩ NTC/PT1000 analog
temperature sensor connection. The device can operate by powering it either
using an external power supply or 3 x 1,5V AA type alkaline batteries on
board. Once the external power supply is disconnected, EW2 will automatically
switch to battery power. In order to start using EW2, it has to be paired with
ELDES alarm system using ELDES Configuration Tool software or by sending a
corresponding SMS text message to ELDES alarm system.
It is possible to connect up to 8 EW2 devices to EPIR3, PITBULL ALARM or
PITBULL ALARM PRO systems, ESIM364 – up to 16, while ESIM384 alarm systems –
up to 32 EW2 devices at a time. The maximum wireless connection range is 150m
(492.13ft) (in open areas).
The cable length should not be more than 3 meters long!
Unit | Description |
---|---|
ANT | Wireless signal antenna SMA type connector |
+/- | Battery slots |
STATUS | Red light-emitting diode for indication of data transmission |
POWER | Green light-emitting diode for indication of external power supply |
status.
RESET| Button for restoring default parameters
FUSE| MINISMDC050F 0.5A
Connector| Description
---|---
COM| Common terminals
DC+| Positive power supply terminal
Z1–Z4| Zone terminals
T1–T2| 10kΩ NTC/PT1000 temperature sensor terminals
C1–C2| Open-collector output terminals
LED indicator| Indication| Description
---|---|---
STATUS (red)| Steady ON/flashing| Data transmission in progress
POWER (green)| Steady ON| Device powered by external power
POWER (green)| OFF| Device powered by battery power / device inoperational
CONFIGURING AND PAIRING WITH THE SYSTEM
For more details on how to configure and pair the device with the system,
please refer to ELDES Configuration Tool software’s HELP section or ELDES
alarm system’s installation/user manual.
If you are unable to pair the wireless device, please restore the parameters
of the wireless device to default and try again (see 6. RESTORING DEFAULT
PARAMETERS for more details.)
EW2 ZONES, PGM OUTPUTS AND TAMPER
Upon successful EW2 pairing process, the system adds 4 wireless Instant-type
zones intended for sensor connection and 2 wireless PGM outputs intended for
electrical appliance, relay or siren connection. In case of tamper violation,
the alarm is caused regardless of system being armed or disarmed.
The wireless connection loss between EW2 and ELDES alarm system leads to
alarm. The system identifies this event as a tamper violation and sends alarm
by SMS text message and phone call to the listed user (-s) by default. The SMS
text message contains the wireless device model, wireless ID code and tamper
name.
The tamper will not operate if the wireless zones are disabled.
The response time might be delayed, while controlling the PGM outputs on a
battery-powered EW2.
For more details on EW2 configuration, please refer to ELDES Configuration
Tool software’s HELP section.
TEMPERATURE SENSORS
EW2 supports up to 2 temperature sensors of 10kΩ NTC or PT1000 type. You may
use a single temperature sensor or multiple temperature sensors
simultaneously. Multiple temperature sensors must be of the same type each
connected to its own T1/T2 terminal. Once the temperature sensor (-s) is
wired, it is necessary to select the corresponding type using ELDES
Configuration Tool software after pairing EW2 device with the system. Also,
after enabling NTC option, you MUST enter the parameter B (beta) of
temperature sensor.
The following table represents the supported temperature range and temperature
measurement accuracy.
Temperature sensor type | Temperature range | Accuracy |
---|---|---|
10kΩ NTC | -40… -26°C (-40…-14.8F) | +/- 2.5°C (4.5F) |
10kΩ NTC | -25… 85°C (-13…185F) | +/- 1°C (1.8F) |
10kΩ NTC | +86… 100°C (186.8..212F) | +/- 2.5°C (4.5F) |
PT1000 | -50… +600°C (-58…1112F) | +/- 2.5°C (4.5F) |
BATTERY REPLACEMENT
- Open EW2 enclosure.
- Remove the old batteries from the battery slots.
- Insert the new batteries based on the battery slot positive/negative terminals indicated on the battery slots of EW2.
- 1,5V Alkaline AA type batteries can be used. Install only new, high quality and unexpired batteries. Do not mix the old batteries with the new ones.
- At least 1 battery must be removed if the device is not in use.
- In order to avoid fire or explosion hazards, the system must be used only with approved battery. Special care must be taken when connecting posi- tive and negative battery terminals. Dispose old batteries only into special collection sites. Do not charge, disassemble, heat or incinerate old batteries.
- The battery status can be monitored in real-time using ELDES Configuration Tool software.
- The system sends an SMS text message to the listed user phone number as soon as the battery level runs below 5%.
- EW2 does NOT feature a built-in battery charging unit, therefore only 1,5V Alkaline AA type (non-rechargeable) batteries can be used.
RESTORING DEFAULT PARAMETERS
- Remove any battery from EW2 and/or disconnect the power supply.
- Press and hold the RESET button.
- Insert the battery back to EW2 and/or connect the power supply.
- Hold the RESET button until LED indicator shortly flashes several times.
Release the RESET button.
The EW2 can be powered by a 7-15V 50mA DC power supply unit, if no additional
devices are connected. The device is not meant for outdoor use, i.e. you
should use it inside a building and the power supply unit must be plugged into
a standard Euro 2-pin socket or UK 3-pin socket (depending on the version of
power supply unit you have bought). When connecting the power supply, mind the
polarity terminals. DO NOT switch the polarity terminals places. The main
circuit should be protected by short circuit or over-current protection.
Please use the power supply that meets the EN 60950-1 standard. Any additional
device you connect to the system, such as a computer, must also be powered by
an EN 60950-1 approved supply.
Disconnect the mains power before installing. Never install or carry out
maintenance during stormy weather. The electric socket that powers the device
must be easily accessible.
To switch the system off, remove the batteries (if any), unplug the external
electric power supply or power down any other linked device that EW2 is
powered from. A blown fuse cannot be replaced by the user. The replacement
fuse has to be of the kind indicated by the manufacturer (fuse F1 model –
MINISMDC050F 0.5A).
TECHNICAL SPECIFICATIONS
Compatible with:
- ESIM364 v02.08.00 and up.
- ESIM384 all versions.
- EPIR3 v1.2.0 and up.
- PITBULL ALARM all versions.
- PITBULL ALARM PRO all versions.
Supply voltage | 7-15V 50mA max |
---|---|
Supported batteries | 1,5V Alkaline AA type LR6 (IEC) /15A (ANSI/NEDA) |
Number of batteries | 3 |
Battery operation time | ~18 months* |
Number of zones | 4 |
Zone connection type | NC (normally-closed) |
Number of PGM outputs | 2 |
PGM output circuit | Open-collector output. |
Output is pulled to COM when turned ON.
Maximum commuting PGM output values| 2 x 25V; 150 mA
Supported temperature sensor types| 10kΩ NTC; PT1000
Wireless band| ISM868/ISM915
Wireless communication range| Up to 30m (98.43ft) in premises;
up to 150m (492.13ft) in open areas
Range of operating temperatures| -20…+55°C (-4… 131°F)
Humidity| 0-90% RH @ 0… +40°C (0-90% RH @ 32… 104°F)
Dimensions| 82x63x17mm (3.23×2.48×0.67in)
Compatible with alarm systems| ELDES Wireless
*** The operation time might vary in different conditions.
Technical support
If you experience difficulty during the installation or subsequent use of a
ELDES UAB system, you may contact ELDES UAB distributor or dealer in your
country/region.
Warranty procedures
To obtain warranty service, you may return a defective system to your original
point of pur- chase, or the authorized ELDES UAB dealer or distributor from
whom you purchased the EL- DES product.
Limited Liability
The buyer must agree that the system will reduce the risk of fire, theft,
burglary or other dangers but does not guarantee against such events. ELDES
UAB will not take any responsibility regarding personal or property or revenue
loss while using the system. ELDES UAB liability according to local laws does
not exceed value of the purchased system. ELDES UAB is not affiliated with any
of the Internet providers therefore is not responsible for the quality of
Internet service.
Manufacturer Warranty**
ELDES UAB warrants this system only to the original purchaser and only in case
of defective workmanship and materials under normal use of the system for a
period of twenty four (24) months from the date of shipment by the ELDES UAB.
Warranty obligations do not cover expandable materials (components, which
require periodic replacement with the operation of system – power elements
(batteries)), holders and enclosures. The warranty remains valid only if the
system is used as intended, following all guidelines outlined in this manual
and in accordance with the operating conditions specified. The warranty is
void if the system has been exposed to mechanical impact, chemicals, high
humidity, fluids, corrosive and hazardous environments or force majeure
factors
Safety instructions
Please read and follow these safety guidelines to safeguard yourself and others:
- DO NOT use the system where it can interfere with other devices – such as medical devices
- DO NOT use the system in hazardous environments
- DO NOT expose the system to high humidity, chemical environments or mechanical impact
- DO NOT attempt to repair the system yourself – any repairs must be carried out by fully qualified personnel only
The WEEE (Waste Electrical and Electronic Equipment) marking on this product
(see left) or its documentation indicates that the product must not be
disposed of together with household waste. To prevent possible harm to human
health and/or the environment, the product must be disposed of in an approved
and environmentally safe recycling process. For further information on how to
dispose of this product correctly, contact the system supplier, or the local
authority responsible for waste disposal in your area.
Copyright © ELDES UAB, 2022. All rights reserved
It is not allowed to copy and distribute information in this document or pass
to a third party without advanced
written authorization by ELDES UAB. ELDES UAB reserves the right to update or
modify this document and/or related products without a warning. Hereby, ELDES
UAB
declares that the wireless zone and PGM output expansion module EW2 is in
compliance with the essential requirements and other relevant provisions of
Directive 1999/5/EC. The declaration of conformity may be consulted at
www.eldesalarms.com
Made in the European Union
www.eldesalarms.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>