Kenmore DU2015 Bagless Upright Vacuum Cleaner User Guide
- June 14, 2024
- Kenmore
Table of Contents
- BEFORE USING YOUR NEW VACUUM CLEANER
- IMPORTANT SAFETY INSTRUCTIONS
- KENMORE VACUUM CLEANER WARRANTY
- PARTS AND FEATURES
- ASSEMBLY INSTRUCTIONS
- OPERATING INSTRUCTIONS
- PERFORMANCE/SAFETY FEATURES
- VACUUM MAINTENANCE AND CARE
- TROUBLESHOOTING
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
DU2015 Bugless Upright Vacuum Cleaner
User Guide
BEFORE USING YOUR NEW VACUUM CLEANER
Read this Use & Care Guide. It will help you assemble and operate your new
Kenmore vacuum cleaner in the safest and most effective way.
For more information about vacuum cleaner care and operation, call the Vacuum
Cleaner Help Line at 1-877-531-7321
(US)/ 1-844-608-3081 (CA). You will
need the complete model and serial numbers when requesting information.
Your vacuum cleaner’s model and serial numbers are located on the Model and
Serial Number Plate. Use the space below to record the model number and serial
number of your new Kenmore vacuum cleaner.
Model No. …………………………..
Serial No…………………….
Date of Purchase………..
Keep this book and your sales check (receipt) in a safe place for future
reference.
PACKING LIST
Your KENMORE VACUUM CLEANER is packaged with the following parts and
components assembled separately in the carton:
Upright Vacuum Cleaner | Extension Wand |
---|---|
Combination Tool | Flexible Hose |
Upholstery Tool | Handle |
Pet Handy Mate@ | Screw Bolt |
Rotating Brush Tool | Use & Care Guide |
IMPORTANT SAFETY INSTRUCTIONS
Read all instructions in this guide before assembling or using your vacuum
cleaner.
WARNING!
Your safety is important to us. To reduce the risk of fire, electrical
shock, injury to persons or damage when using your vacuum cleaner, follow
basic safety precautions including the following:
- Use your vacuum cleaner only as described in this Use & Care Guide. Use only manufacturer’s recommended attachments.
- Disconnect electrical supply before servicing or cleaning out the brush area. Failure to do so could result in the brush unexpectedly starting, causing personal injury from moving parts.5
- Do not leave vacuum cleaner when plugged in. Unplug from outlet when not in use and before performing maintenance.
- To reduce the risk of electrical shock – Do not use outdoors or on wet surfaces.
- Do not allow to be used as a toy. Close attention is necessary when used by or near children.
- Do not use with a damaged cord or plug If vacuum cleaner is not working as it should, has been dropped, damaged, left outdoors, or dropped in water, immediately discontinue use and call 1-877-531-7321 (US)/ 1-844-608-3081 (CA) for assistance.
- Do not pull or carry by cord, use cord as a handle, close a door on cord, or pull cord around sharp edges or corners. Do not run vacuum cleaner over cord. Keep cord away from heated surfaces.
- Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord.
- Do not handle plug or vacuum cleaner with wet hands.
- Do not put any objects into openings.
- Do not use with any opening blocked; keep free of dust, lint, hair, and anything that may reduce air flow.
- Keep hair, loose clothing, fingers, and all parts of body away from openings and moving parts.
- Turn off all controls before unplugging.
- Use extra care when cleaning on stairs.
- Do not put on chairs, tables, etc. Keep on floor.
- Do not use vacuum cleaner to pick up flammable or combustible liquids (gasoline, cleaning fluid, perfumes, etc.), or use in areas where they may be present. The fumes from these substances can create a fire hazard or explosion.
- Do not pick up anything that is burning or smoking, such as cigarettes, matches, or hot ashes.
- Do not use vacuum cleaner without dust cup and/or filters in place.
- Always clean the dust cup after vacuuming carpet cleaners or freshener, powders, and fine dust. These products clog the filters, reduce airflow and can cause damage to the vacuum cleaner. Failure to clean the dust cup could cause permanent damage to the vacuum cleaner.
- Do not use the vacuum cleaner to pick up sharp hard objects, small toys, pins, paper clips, etc. They may damage the vacuum cleaner or dust cup.
- You are responsible for making sure that your vacuum cleaner is not used by anyone unable to operate it properly.
SAVE THESE INSTRUCTIONS
Proper assembly and safe use of your vacuum cleaner are your responsibilities.
Your vacuum cleaner is intended for Household Use. Read this Use & Care Guide
carefully for important use and safety information. This guide contains safety
statements under warning and caution symbols.
Allergen Seal™ Certification lets you know that this vacuum traps 99.97% of
dust and particles inside your vacuum, keeping them out of the air you
breathe.
KENMORE VACUUM CLEANER WARRANTY
KENMORE LIMITED WARRANTY
FOR ONE YEAR from the date of sale this product is warranted against defects
in material or workmanship.
WITH PROOF OF SALE a defective product will be replaced free of charge. The
Kenmore brand is used under license. Direct all claims for warranty service
to: Cleve North America, Inc.,
1-877-531-7321 (US)/
1-844-608-3081 (CA).
This warranty does not cover filters or belts, which are expendable parts that
can wear out from normal use within the warranty period.
This warranty is void if this product is ever used for other than private
household purposes. This warranty gives you specific legal rights, and you may
also have other rights which vary from state to state.
Cleve North America, Inc., Greenville SC 29607
PARTS AND FEATURES
It is important to know your vacuum cleaner’s parts and features to assure its
proper and safe use. Review these before using your vacuum cleaner.
REPLACEMENT PARTS
Item | Part No.(US) | Part No.(CA) |
---|---|---|
Foam Filter | 561055105 | 561055105 |
Felt Filter | 561055106 | 561055106 |
HEPA Media Exhaust Filet | 561055118 | 561055118 |
Belt | l<C28SEDCZ000 | l<C28SEDCZ000 |
3-in-1 Combination Tool | 561055134 | 561055134 |
Upholstery Tool | 561055176 | 561055176 |
Rotating Brush Tool | 561060176 | 561060176 |
Pet HandiMate° | 561014106 | 561014106 |
Extension Wand | 561055128 | 561055128 |
Flexible Hose | 561055129 | 561055129 |
Screw Bolt | 561055131 | 561055131 |
To order a replacement part, all
1-877-531-7321 (US)/
1-844-608-3081 (CA).
Please pay special attention to these hazard alert boxes, and follow any
instructions given.
WARNING statements alert you to such hazards as fire, electric shock,
burns and personal injury.
CAUTION statements alert you to such hazards as personal injury and/or
property damage.
ASSEMBLY INSTRUCTIONS
Before assembling the vacuum cleaner, check the PACKING LIST (page 2). Use this list to verify that you have received all the components of your new Kenmore Bugless Upright Vacuum Cleaner.
-
Insert the handle into the main body and secure with one screw bolt provided.
NOTE: Tighten the screw bolt with a screwdriver or a coin. Ensure that the screw bolt is secured. -
Insert the larger end of the extension wand into the top of the connection hose through the bracket until the wand is fully seated on the post.
-
Insert the end of the flexible hose into the main body by aligning marks as shown in UNLOCKED (for cleaning). Rotate the hose until marks align as shown in LOCKED (for use). Then run the flexible hose over the lower hose storage and the upper hose storage. Insert the other end onto the top of the extension wand.
-
Insert the combination tool onto the accessory storage post located on the back of the main body.
-
Make sure the upper and lower cord hooks are in the proper position as shown. Wrap the power cord loosely around the upper and lower cord hooks.
NOTE: Make sure to wrap the power cord around the upper cord hook first, and then around the lower cord hook to avoid damaging the power cord. -
Lock power cord plug onto the power cord.
WARNING
Electrical Shock and Personal Injury Hazard.
Wrapping the cord too tightly with excessive stress on the cord may cause cord
damage. A damaged cord is an electrical shock hazard and could cause personal
injury or damage.
OPERATING INSTRUCTIONS
CAUTION
Moving parts! To reduce the risk of personal injury, DO NOT touch the brush
roll when vacuum is on. Contacting the brush roll while it is rotating can
cut, bruise or cause other injuries. Always turn off before servicing. Use
caution when operating near children or pets.
POWER CORD – RELEASE & USE
-
Turn the upper cord hook to either side to release the power cord. WARNING
To reduce the risk of electric shock, this appliance has a polarized plug (one blade is wider than the other). This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician to install the proper outlet. Do not change the plug in any way. -
Detach the power cord plug from the power cord.
-
Be sure the power cord is locked into the upper locking notch as shown. This will help manage the power cord when operating the vacuum cleaner.
-
Plug the power cord plug into an outlet located near the floor.
WARNING
Personal Injury and Product Damage Hazard
• When any abnormality/failure occurs, stop using the product immediately and disconnect the power plug.
• DO NOT use outlets above counters. Damage from cord to items in surrounding area could occur. -
Press the On/Off switch to turn the vacuum cleaner on.
-
Once you have completed vacuuming, press the On/Off switch; unplug the power cord plug from the outlet.
-
To restore power cord after use, turn the upper cord hook to the upright position. Then wrap cord loosely around cord hooks.
WARNING
Electrical Shock and Personal Injury Hazard
Wrapping the cord too tightly puts stress on the cord and can cause cord
damage. A damaged cord is an electrical shock hazard and could cause personal
injury or damage
OPERATION MODES
UPRIGHT MODE
NOTE: Make sure the vacuum cleaner is completely assembled and the dust
cup is empty before using. Do not operate vacuum cleaner without filters in
place.
-
Release the handle by placing foot on the nozzle and pull back to change handle position.
-
Turn on the vacuum cleaner by pressing the On/Off switch to the “I” position for cleaning bare floors and small area rugs.
NOTE: The brush roll does not rotate when the vacuum cleaner is in the “I” position. -
Press the switch to the “II” position for cleaning carpets or rugs.
NOTE: The brush roll rotates when the vacuum cleaner is in the “II” position.
CAUTION
Do not allow the vacuum cleaner to remain in one spot for any length of time when the brush roll is turning. Damage to carpet may occur. -
Once you have completed vacuuming, switch to the “O” position and unplug the power cord from the power outlet.
NOTE: Select the right mode when using this vacuum cleaner. Do not press the switch to the “II” position when cleaning the bare floor, otherwise it will damage the floor.
BRUSHROLL INDICATOR LIGHT
Light Color | Status |
---|---|
Green, Continuous | The brush roll is spinning and working as it should. |
Red, Continuous | There is a jam in the brush roll area. Turn off and unplug |
the vacuum, and remove any blockages in the nozzle.
No Light| The brush roll is off.
ABOVE FLOOR MODE
- Place the vacuum cleaner in the upright locked position.
- Pull up to release the flexible hose for above floor cleaning.
- Choose the desired extension wand/ attachments and insert it into the flexible hose.
- Turn on the vacuum cleaner by pressing the switch to the “I” position.
- Once you have completed vacuuming, switch to the “O” position and unplug the power cord from the power outlet.
CAUTION
When using attachments, be careful not to over extend the flexible hose when
reaching. Trying to reach beyond the hose stretch capability could cause the
vacuum cleaner to tip over.
CAUTION
DO NOT pull the vacuum cleaner around the room by the hose. Property damage
or personal injury could result.
ATTACHMENTS
3-IN-1 COMBINATION TOOL
The 3-in-1 combination tool can be attached to the end of the flexible hose
and the extension wand. Slide the collar of the tool over the open end of the
hose or wand.
Use the 3-in-1 combination tool in crevice tool mode for cleaning in tight
spaces such as furniture, between cushions, and stairs. See ATTACHMENT USE
TABLE (page 13). Set the combination tool in dusting brush mode by pressing
the release button and sliding the dusting brush side of the brush tool to the
end of the combination tool. Use in dusting brush mode for cleaning loose
surfaces such as drapes. See ATTACHMENT USE TABLE (page 13). Press the release button to remove the brush tool. Set the
combination tool in upholstery brush mode as shown. Use in upholstery brush
mode for cleaning fabric surfaces such as fabric sofa. See
ATTACHMENT USE TABLE (page 13).
To return the combination tool to crevice tool mode, press the
release button and slide the brush tool down the combination tool.
UPHOLSTERY TOOL
The upholstery tool can be attached to the end of the flexible hose and the
extension wand. Slide the collar of the tool over the open end of the hose or
wand. Use the upholstery tool for cleaning fabric surfaces such as fabric sofa
and bedsheets See ATTACHMENT USE TABLE (page 13) ATTACHMENTS
PET HANDIMATE
The Pet Handmade” can be attached to the end of the handle or the wand. Pet
HandiMate”pivots for convenient cleaning.
Use Pet Handmade” for cleaning fabric surfaces such as furniture and carpet.
See ATTACHMENT USE TABLE (page 13). WARNING
NEVER use the Pet Handmade”” directly on pets, as it can cause injury.
ROTATING BRUSH TOOL
Rotating brush tool can be attached to the handle or wand for overhead
cleaning of furniture such as cabinets and shelves. See ATTACHMENT USE TABLE
(page 13). CAUTION
Use attachments when the vacuum cleaner is upright.
ATTACHMENT USE TABLE
CLEANING AREA Applicable CLEANING AREA ✓ =Applicable
ATTACHMENT| Furniture| Between Cushions| **Drapes*|
Stairs| Baseboards**
Carpet Bare
CREVICE TOOL| | ✓| | ✓| ✓| V
DUSTING BRUSH| ✓| | ✓| ✓| ✓| ✓
UPHOLSTERY BRUSH | ✓| | ✓| | |
UPHOLSTERY TOOL | ✓| | ✓| | |
PET HANDIMATE | ✓| | | ✓| |
ROTATING BRUSH TOOL | ✓| | | | |
*Always clean attachments before using on fabrics
PERFORMANCE/SAFETY FEATURES
THERMAL PROTECTOR
This vacuum cleaner has a thermal protector which automatically trips to
protect the vacuum cleaner suction motor. If a clog prevents the normal flow
of air to the motor, the thermal protector turns the motor off automatically.
This allows the motor to cool in order to prevent possible damage to the
vacuum cleaner. To reset thermal protector: Turn the vacuum cleaner off and
unplug the power cord from the outlet to allow the vacuum cleaner to cool and
the thermal protectors to reset.
CAUTION
Always return the vacuum cleaner to the upright position before using the hose
and attachments. Failure to do so may result in overheating of the brush roll
motor and can cause the thermal protectors to trip. Check for and remove
clogs, and empty dust cup if necessary. Also check and replace any clogged
filters. Wait approximately 50 minutes before restarting vacuum cleaner.
BRUSHROLL RESET
The brush roll has built-in protection against motor damage should the brush
roll jam. If the brush roll slows down or stops, the brush roll overload
protector shuts off the brush roll motor and the brush roll status indicator
emits red light. The vacuum cleaner suction motor will continue to run. To
correct problem: Turn off and unplug the vacuum cleaner, remove
obstruction, then turn on the vacuum cleaner.
NOTE: Once the brush roll motor shuts down, clear jam from the brush roll
before resetting.
If the problem persists, contact the vacuum cleaner help line for assistance.
SUCTION CONTROL
The suction control allows you to change the vacuum cleaner suction for
different fabric and carpet weight.
- Rotate to “+” to increase suction on bare floors.
- Rotate to”-” to reduce suction and increase maneuverability on carpets.
VACUUM MAINTENANCE AND CARE
Always follow all safety precautions when performing maintenance to the vacuum
cleaner.
WARNING
Electrical Shock and Personal Injury Hazard Disconnect electrical supply
before servicing or cleaning the vacuum cleaner. Failure to do so could result
in electrical shock or personal injury from vacuum cleaner suddenly starting.
CLEANING EXTERIOR AND ATTACHMENTS
- Turn off and unplug vacuum cleaner. DO NOT drip water on vacuum cleaner.
- To clean exterior, or to reduce static electricity and dust build-up, wipe outer surface with a clean, soft cloth that has been dipped in a solution of mild liquid detergent and water, then wrung dry. Wipe dry after cleaning.
NOTE: Wash attachments in warm soapy water, rinse and air dry. Do not
clean in dishwasher.
CAUTION
Do not use attachments if they are wet. Attachments used in dirty areas,
such as under a refrigerator, should not be used on other surfaces until they
are washed. They could leave marks.
WARNING
Electrical Shock and Personal Injury Hazard
Wrapping the cord too tightly puts stress on the cord and can cause cord
damage damaged cord is an electrical shock hazard and could cause personal
injury or damage.
- Replace flexible hose and attachments in storage position if necessary (see page 7 & 8).
- Gather the cord and wrap it loosely around the upper and lower cord hooks. Lock plug retainer onto the power cord.
- Store the vacuum cleaner in a dry, indoor area, on the floor with the handle locked in the upright position.
EMPTYING DUST CUP
WARNING
Always unplug power cord from electrical outlet before performing any service
on vacuum cleaner.
NOTE: For best performance, empty dust cup after every use. Never operate
vacuum cleaner without dust cup and filters in place.
- Slide the dust cup release button to remove the dust cup from the main body.
- Remove any clogs that might be located in the suction port.
- Position dust cup area of vacuum over a waste receptacle. Press down on the dust release button to open dust cup lid and allow contents to drop into waste receptacle.
- Shake the dust cup to release any debris that might hang in the pre-filter.
- Reinstall and insert the dust cup into the slots on the bottom of the main body, then press the dust cup into locked slot and click into place.
PRE-FILTER CLEANING
The pre-filter is located inside the dust cup. Clean the pre-filter as
needed to optimize suction power. If suction remains weak after tapping the
pre-filter clean, it will be necessary to wash it to clean off accumulated
dust or hair. It is also recommended to wash the pre-filter every three
months. See wash instructions in th NOTE to step 4.
-
Remove the dust cup as outlined in the EMPTYING DUST CUP (page 16).
NOTE: Make sure dust cup is free of debris before opening. -
Press the dust cup lid release button, and open the lid.
-
rasp pre-filter and rotate counterclockwise as shown to remove.
-
Clean pre-filter by gently tapping over a trash container. Tap on several sides to ensure best cleaning.
NOTE: If necessary, rinse with cold water only, DO NOT use detergent or soap. Allow parts to dry 24 hours before putting back into vacuum cleaner. DO NOT wash in the dishwasher. DO NOT install damp. -
Place the pre-filter back into the dust cup. Grasp pre-filter and rotate clockwise to lock into place.
-
Reinstall the dust cup into the main body. See installation instructions in the EMPTYING DUST CUP (page 16).
FOAM AND FELT FILTERS CLEANING
It is recommended to clean the foam and felt filters with cold water every
three months.5
NOTE: When the cleaning of filters no longer restores vacuum cleaner
suction to full power, or the filters are worn or broken, replace the filters.
To purchase filters, call
1-877-531-7321 (US) /1-844 608-3081
(CA).
Regularly clean and replace the filters to keep the vacuum’s suction power
optimal.
- Remove the dust cup as outlined in the EMPTYING DUST CUP (page 16).
- Remove the foam and felt filters
- Wash with cold water only, DO NOT use detergent or soap. Squeeze by hand and allow to air dry. Allow all filters to dry 24 hours before putting back into vacuum cleaner.
NOTE: DO NOT operate without foam and felt filters installed. DO NOT wash in the dishwasher. DO NOT install foam and felt filters if damp.
-
Replace foam and felt filters into the vacuum cleaner.
-
Reinstall the dust cup. See EMPTYING DUST CUP (page 16)
HEPA MEDIA EXHAUST FILTER CLEANING
It is recommended to clean the HEPA media exhaust filter with cold water
every year.
NOTE: When the cleaning of the filter no longer restores vacuum cleaner
suction to full power, or the filter is worn or broken, replace the exhaust
filter. To purchase the exhaust filter, call
1-877-531-7321 (US)/
1-844-608-3081 (CA).
-
Remove the exhaust filter cover by pressing the release tab at the bottom of the cover.
-
Remove the HEPA media exhaust filter from vacuum cleaner.
-
Wash with cold water only, DO NOT use detergent or soap. Allow to air dry. Allow parts to dry 24 hours before putting back into vacuum cleaner.
NOTE: DO NOT operate without exhaust filter installed.
DO NOT wash in the dishwasher. DO NOT install the filter if damp. -
Replace the HEPA media exhaust filter into the vacuum cleaner.
-
Insert the exhaust filter cover tabs into the upper slots and lock the filter cover into place by pressing the lower part of the cover until a click is heard.
BELT CHANGING
WARNING
Always unplug power cord from electrical outlet before performing maintenance
to the vacuum cleaner. Replace belt whenever a burning rubber smell caused by
excessive slippage occurs.
-
Lay the vacuum cleaner on floor with the bottom up and motorized nozzle flat.
-
Use a coin to release the lower plate by rotating the three lower plate latches counterclockwise to the UNLOCK position. Lift off the lower plate.
CAUTION Motor shaft may be hot. -
Remove the brush roll by carefully lifting it out.
-
Remove the worn or broken belt.
-
Use scissors to remove any entangled hair around the brush roll. Clean any debris from the motorized nozzle.
-
Loop new belt around the motor shaft and brush roll.
-
Reinstall the brush roll back into nozzle by placing end caps into slots. First align the end cap of non-belt side of the brush roll with the slot and insert it into place. Then press down the end cap of the belt side firmly into the slot until a click is heard. Check the brush roll to ensure it rotates smoothly.
-
Reinstall the lower plate by aligning tabs on front edge of lower plate with slots in the nozzle, inserting the tabs into place, and then rotating the lower plate to installed position.
-
Press the lower plate onto nozzle until a click is heard and secure by rotating the lower plate latches clockwise to the LOCK position.
BRUSHROLL CLEANING
WARNING
Always unplug the power cord from an electrical outlet before performing
maintenance to the vacuum cleaner. To maintain efficient cleaning, the brush
roll must be kept free of carpet fiber, string, or hair build-up. After every
7 to 10 uses or when the brush roll is jammed, unplug and turn vacuum cleaner
over and check brush roll for fiber and hair build-up. Use scissors to remove
any build-up entangled around the brush roll.
PET HANDIMATE® CLEANING
WARNING
Always unplug the power cord from an electrical outlet before performing
maintenance to the vacuum cleaner.
CAUTION reduce the risk of injury from moving parts, remove Pet Handmade”
from vacuum hose or wand before servicing.
PET HANDIMATE® CLEANING
Cut off any carpet pile and lint entangled around brush roll with a pair of
scissors. REMOVING CLOGS
CHECKING FLEXIBLE HOSE FOR CLOGS
If there is noticeable abnormal noise when using the vacuum or the suction
power suddenly drops, it is necessary to check the flexible hose for clogs.
Frequently check air path to make sure it is free of obstructions.
- Remove attachments from the wand end of flexible hose.
- Remove the flexible hose end from the main body by rotating the hose until marks align as shown in UNLOCKED (for cleaning).
- Remove hose end, check and remove any clogs in the flexible hose.
- Reinstall the flexible hose to the vacuum cleaner. See ASSEMBLY INSTRUCTIONS (page 7 & 8).
CHECKING CONNECTION HOSE FOR CLOGS
- Press the release tab on hose cuff, and pull the connection hose away from the main body.
- ‘Check and remove any clogs in the hose.
- Press the release tab, and reinsert the connection hose to the vacuum cleaner until a click is heard.
TROUBLESHOOTING
Review this table to find do-it-yourself solutions for minor performance
problems. Any service needed, other than maintenance described in this Use &
Care Guide, should be performed by a qualified service agent.
WARNING
Disconnect electrical supply before performing maintenance to the vacuum
cleaner. Failure to do so could result in electrical shock or personal injury.
PROBLEM | POSSIBLE CAUSE | SOLUTION |
---|---|---|
Vacuum cleaner will not run. | Unplugged at wall outlet. | Plug in firmly, press |
the On/Off switch to “I” or “II” position.
The On/Off switch is not pressed to start the vacuum cleaner.| Press the
On/Off switch to “I” or “II” position.
The vacuum body is overheated.| Unplug the power cord and let the vacuum cool
down for 50 minutes.
The motor is damaged.| Call
1-877-531-7321 (US) /
1-844-608-3081 (CA) for assistance.
Defective wall outlet.| Check with a good appliance or lamp. Be sure the power
cord plug is fully plugged into a good wall outlet.
Poor job of dirt pick-up.| Full or clogged dust cup.| Empty the dust cup (page
16).
Filters need cleaning.| Follow filter cleaning instructions on page 17-19.
The brush roll or belt is worn or broken.| Replace the brush roll or belt. To
purchase parts, call 1-877-531-7321
(US) / 1-844-608- 3081 (CA).
The flexible hose is worn.| Replace the hose. To purchase parts, call
1-877-531-7321 (US) /
1-844-608-3081 (CA).
The connection hose is worn.| Call
1-877-531-7321 (US) /
1-844-608-3081 (CA) for assistance.
The foam and felt filters are dirty or worn.| Clean the foam and felt filters.
Replace if they are worn or broken. Follow instructions on page 18.
There is a clog in the flexible hose or connection hose of the vacuum
cleaner.| Check and remove all clogs. Follow instructions on page 22.
Dust cup is not installed well.| Check dust cup for correct installation and
ensure it is snapped firmly in place.
The hose or attachments are not installed well.| Check the hose and
attachments for correct installation and ensure they are snapped firmly in
place.
| Suction control is in open position.| Adjust the suction control to increase
suction. Follow instructions on page 14.
---|---|---
Dust escapes from the vacuum.| HEPA media exhaust filter is damaged and needs
to be replaced.| Replace the exhaust filter. To purchase parts, call
1-877-531-7321 (US) /
1-844-608-3081 (CA).
Dust cup is installed incorrectly.| Position dust cup correctly and snap
firmly in place.
HEPA media exhaust filter is installed incorrectly.| Check exhaust filter for
correct installation. Follow instructions on page 19.
Brush roll does not turn.| Brush roll is jammed.| Remove obstruction. Follow
instructions on page 20.
Brush roll is not installed well.| Remove brush roll and reinstall following
instructions on page 20.
The belt is worn or broken.| Replace the belt. To purchase parts, call
1-877-531-7321 (US) /
1-844-608-3081 (CA).
The belt is not routed correctly.| Check the belt routing on page 20.
Fault in the brush roll motor or PC section of the motorized nozzle.| Call
1-877-531-7321 (US) /
1-844-608-3081 (CA) for assistance.
Airflow restricted with attachments In use; sound changes.| Attachments use
restricts air flow.| Check attachments for fuzz, lint, pet hair or other
debris.
New carpet fuzz clogged air path.| Check for and remove any clogs and clean
the hose.
HEPA media exhaust filter is installed incorrectly.| Check exhaust filter and
the exhaust filter cover for correct installation. Ensure the filter cover is
snapped firmly in place.
Vacuum turns off on its own.| Thermal protector is activated.| Turn the vacuum
cleaner off and unplug it. Allow the vacuum cleaner to cool for a
minimum of 50 minutes. Plug in vacuum and turn it on.
The power cord plug is loose from the outlet when using the vacuum.| Reinsert
the power cord plug fully into the outlet. Avoid pulling or dragging the power
cord when using the vacuum.
The motor is damaged.| Call
1-877-531-7321 (US) /
1-844-608-3081 (CA) for assistance.
Brush roll status indicator light emits red.| There is a jam in the brush roll
area.| Turn off and unplug the vacuum, and remove any blockages in the nozzle.
See page 14.
Fault in the brush roll motor or Pa section of the motorized nozzle.| Call
1-877-531-7321 (US) /
1-844-608-3081 (CA) for assistance.
Vacuum Cleaner Help Line:
l-877-531-7321 (US)/
l-844-608-3081 (CA)
8:00am-5:00pm EST, M-F
www.kenmorefloorcare.com
Kenmore and the Kenmore logo are registered trademarks of KCD IP, LLC and/or
Transform SR
Brands LLC and are used under license.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>