COPELAND 4713 R5 Cold Chain Connect Mobile Application User Guide
- June 15, 2024
- Copeland
Table of Contents
- Download the Cold Chain Connect Application
- Register the App
- How to Activate Bluetooth® on the CC200 Case Display
- Connecting to a Case
- Information on the Case Tab
- How to Set Parameters
- Manual Defrost
- Overrides
- Restart the CC200
- Viewing Alarms
- Disconnect from the Case
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Cold Chain Connect Mobile Application
CC200 Guide
Cold Chain Connect is a mobile application for connecting to the Copeland CC200 refrigerated case controller. This document is a guide for using the Cold Chain Connect App to set parameters, graph inputs and outputs, set service overrides, and view alarms. Cold Chain Connect provides a window into CC200 operation and diagnostics directly at the location of the refrigerated fixture or walk-in box.
Download the Cold Chain Connect Application
Download the Cold Chain Connect App from the App Store®:
https://www.apple.com/app-store/
Download the Cold Chain Connect App for Android™ at Google Play
Store:https://delivr.com/2hpma-qr
Register the App
a. Select New User? Register.
b. Fill out all the required fields and press Register.
c. You will receive an email once your account has been activated.
How to Activate Bluetooth® on the CC200 Case Display
a. Step 1: Unlock Screen: Press and hold for three seconds on the top right
corner of the screen. Once the Display is unlocked, SET will be visible in the
bottom left corner and PRG will be visible in the top right corner: After 5
minutes with no touch activity, the Display keyboard locks automatically.
b. Step 2: Virtual Keyboard: Swipe left or right to navigate to the virtual
keyboard:
c. Step 3: Turn ON Bluetooth®: From the virtual keyboard, press and hold the
Bluetooth® icon on the top right corner for three seconds.
d. Once Bluetooth® is activated, a small Bluetooth® status icon in the lower
right corner of the Display will begin to blink slowly, indicating the CC200
is ready for connection. The Bluetooth® status icon turns solid when Cold
Chain Connect is actively connected.
Notice : After 10 minutes with no connection from Cold Chain Connect,
Bluetooth® on the CC200 switches off automatically.
Connecting to a Case
a. Once the CC200 Bluetooth® is ON (refer to Step 3) and the Bluetooth® icon
is blinking slowly, the CC200 is ready to connect to the Cold Chain Connect
App.
b. Turn Bluetooth® ON the mobile device or tablet. Open Cold Chain Connect and
sign in. After signing in, Cold Chain Connect will scan for nearby CC200
controllers and available controllers will be displayed as shown in the below
graphic.
c. Tap the name of the CC200 you wish to connect to:
Information on the Case Tab
Once a connection with a CC200 has been established, the Case tab will appear with CC200 status information and availableservice commands.
- Case Temp
- Case Superheat
- Status of the relay outputs
- Overrides
- Presures
- Alarms
How to Set Parameters
a. Select the Parameters tab at the bottom of the application.
b. On the Parameters screen, a list of parameter groups is shown.
c. Touch the first group name to enter the group and begin the configuration
process.
• Each group will have a list of parameters and a description. The current
value of the parameter is shown in blue to the right of the name.
d. Touch the first parameter in the group to bring up the edit control.
• Enter the desired value and press Done. The new edit will be displayed above
the original value of the parameter.
e. Edit all the desired parameters within the group.
• Press Save in the top right corner of the Group screen.
f. Repeat the procedure for all the groups. NOTICE : Pressing Back
discards any edits selected for that group and they will not be saved to the
CC200.
Manual Defrost
a. From the dashboard, scroll down to COMMANDS.
b. Select Manual Defrost.
c. A pop-up will appear with two options:
• Manual Defrost
This option puts the CC200 into a defrost cycle immediately. The CC200 will
terminate the defrost according to the programmed defrost parameters as if it
were a normally scheduled defrost cycle.
• Emergency Defrost
This option puts the CC200 into a defrost cycle immediately; however, the
CC200 will run the defrost cycle for the maximum period of time programmed in
the defrost parameter group.
d. To cancel the Manual Defrost or Emergency Defrost:
• Select Manual Defrost again and now, a pop-up window to End Manual Defrost
will appear. Select End Manual Defrost and the defrost is now cleared.
Calibrate Valve
a. From the dashboard, scroll down to COMMANDS.
b. Select Calibrate EEPR.
c. The valve will start calibrating.
NOTICE The calibration cannot be stopped once it has started.
Overrides
a. From the dashboard, scroll down to COMMANDS.
• You will see a list of overrides that can be manually configured.
• All overrides are timed and with a maximum time of 10 minutes.
b. Select the desired override to enter on the Override screen.
c. In the Override screen, toggle the switch and two new fields will become
visible.
d. Select the override value and length of time. A maximum time duration of 10
minutes is allowed for all overrides.
e. Once a value and length of time have been chosen, press Save to set the
override. The override can be changed at any time by re-entering the screen,
choosing a different value, and pressing Save.
f. Active overrides will be highlighted blue in the dashboard for easy
identification.
g. To cancel an active override, tap the override from the main Case tab. Turn
off the green toggle switch and press Save.
Restart the CC200
For convenience and service there is a command to reboot the CC200. To reboot
the CC200, select the Restart CC200 command from the list. A pop-up will be
shown to confirm the action. The CC200 will perform a soft reboot and status
information will be temporarily unavailable in the Cold Chain Connect
dashboard. Real-Time Graphs
a. Select the Analytics tab at the bottom of the application.
b. Select Filter at the top of the application.
• Select the desired values to graph from the list of available CC200 data
points and press Apply. Cold Chain Connect will begin building the graph.
• A maximum of two analog data types and two ON/OFF data types can be graphed
simultaneously. Tap the graph line anywhere to see a plot marker of the value
at that point in time.
c. Select and you will be able to select three options:
• 5 minutes
• 10 minutes
• 15 minutes
d. Select Share at the top of the application.
• You will be prompted to share the graph.
Viewing Alarms
Active CC200 alarms can be viewed in the Case tab by tapping the alarm icon in
the upper right corner of the Case screen. When one or more alarm conditions
are active, the alarm icon will be red, if there are no active alarms the icon
will be gray and the count will be zero. An alarm icon will appear next to any
piece of data in the Case tab that has an active alarm. Tap the icon next to
the data point to see the description. Info
a. Select Info at the bottom of the application and you will see the Store
info, CC200 version, and the Cold Chain Connect version:
Disconnect from the Case
a. Select Connection at the bottom of the application.
- You will see a pop-up windown asking you to Disconnect.
- Select Yes, Disconnect and you will be disconnected from the Case.
For Technical Support: Call:
833-409-7505 or
Email:
ColdChain.TechnicalServices@copeland.com
For the full user manual, scan the QR
code:https://www.copeland.com/documents/026-1740-cc200-user-guide-en-
us-7503288.pdf
The contents of this publication are presented for informational purposes only and they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. Copeland reserves the right to modify the designs or specifications of such products at any time without notice. Responsibility for proper selection, use and maintenance of any product remains solely with the purchaser and end-user. ©2023 Copeland is a trademark of Copeland LP.
026-4713 | R5 | V1023
copeland.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>