BANNER WLR95 In-Line Work Light Owner’s Manual
- June 15, 2024
- BANNER
Table of Contents
BANNER WLR95 In-Line Work Light
Product Information
The WLR95 In-Line Work Light is a versatile lighting solution designed for various applications. It features a cool white color temperature of 6500K, providing bright and clear illumination. The light has an integral 4-pin M12 male/female quick-disconnect connector for easy installation and connection. The work light operates within a voltage range of 12V DC to 30V DC and requires a suitable Class 2 power supply (UL) or a SELV power supply (CE). It is protected against reverse polarity and transient voltages, ensuring safe and reliable operation. The construction of the work light includes a nickel- plated brass connector and a TPU clear housing. A removable cap is included to cover the female quick disconnect.
The WLR95 In-Line Work Light meets various industry standards for vibration, mechanical shock, and environmental rating. It complies with IEC 60068-2-6 requirements for vibration and IEC 60068-2-27 requirements for mechanical shock. The work light has an impact rating of IK06 and an environmental rating of IP65, IP67, IP68, and UL Type 1.
It is important to note that electrical connections should be made by qualified personnel in accordance with local and national electrical codes and regulations. Overcurrent protection is required as specified in the provided table. The work light supports dimming functionality with high/low/off options, depending on the wiring configuration.
Product Usage Instructions
- Ensure that the power supply voltage is within the range of 12V DC to 30V DC.
- Connect the work light using the integral 4-pin M12 male/female quick-disconnect connector. Match the corresponding male and female pins/wires.
- For wiring, refer to the pin wire color and description provided in the manual.
- Use the brown wire for connecting to 12V DC to 30V DC power supply.
- The white wire is not used and can be left disconnected.
- Connect the blue wire to the DC common.
- Connect the black wire to 12V DC to 30V DC for 50% of maximum intensity. For 100% intensity, leave the black wire floating or connected to common.
- Ensure continuity between the male and female connections for all four wires.
- For proper overcurrent protection, refer to the supplied table and use suitable wiring based on AWG size.
- Mount the work light using the integral through holes for M4 (#8) screws or choose from available bracket options.
- For additional support, visit www.bannerengineering.com.
Features
- Rugged waterproof and dustproof overmolded design meets IP65, IP67, and IP68
- Daisy-chain multiple lights with double-ended cables
- Compact space-saving design
- Designed for enclosure, conveyor, machine, or vision lighting
Models
Models | Color | Connection |
---|---|---|
WLR95WQ | Cool White (6500K) | Integral 4-pin M12 male/female quick- |
disconnect connector
Wiring
Specifications
- Supply Voltage
- 12 V DC to 30 V DC
- Use only with suitable Class 2 power supply (UL) or a SELV power supply (CE)
- See electrical characteristics on product label
- Supply Protection Circuitry
- Protected against reverse polarity and transient voltages
- Connections
- Integral 4-pin M12 male/female quick-disconnect connector
- Construction
- Connector: Nickel-plated brass
- Housing: TPU clear
- Removable cap covering female quick disconnect included
- Vibration and Mechanical Shock
- Meets IEC 60068-2-6 requirements (Vibration: 10 Hz to 55 Hz, 1.0 mm amplitude, 5 minutes sweep, 30 minutes dwell)
- Meets IEC 60068-2-27 requirements (Shock: 15G 11 ms duration, half sine wave)
- Impact: IK06
- Light Characteristics
- Color Temperature: 6500K ± 1000K
- Lumens: 600
- CRI: 80 minimum
- Environmental Rating
- IP65, IP67, IP68
- UL Type 1
Required Overcurrent Protection
WARNING: Electrical connections must be made by qualified personnel in
accordance with local and national electrical codes and regulations.
Overcurrent protection is required to be provided by end product application per the supplied table. Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply. Supply wiring leads < 24 AWG shall not be spliced. For additional product support, go to www.bannerengineering.com.
Supply Wiring (AWG)| Required Overcurrent Protection
(A)| Supply Wiring (AWG)| Required Overcurrent
Protection (A)
---|---|---|---
20| 5.0| 26| 1.0
22| 3.0| 28| 0.8
24| 1.0| 30| 0.5
Operating Conditions
- Temperature: –40 °C to +50 °C (–40 °F to +122 °F) 90% at +50 °C maximum relative humidity (non-condensing)
- Storage Temperature: –40 °C to +70 °C (–40 °F to +158 °F)
Dimming
High/Low/Off models: 100/50/0% intensity, dependent on wiring.
LED Lifetime
- Lumen Maintenance – L70
- When operating within specifications, output will decrease less than 30% after 70,000 hours.
Mounting
- Integral through holes for M4 (#8) screws
- Multiple bracket options available
Certifications
Banner Engineering BV
Park Lane, Culliganlaan 2F bus 3
1831 Diegem, BELGIUM
FCC
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Industry Canada ICES-003(B)
This device complies with CAN ICES-3 (B)/NMB-3(B). Operation is subject to the
following two conditions: 1) This device may not cause harmful interference;
and 2) This device must accept any interference received, including
interference that may cause undesired operation.
Dimensions
All measurements are listed in millimeters [inches], unless noted otherwise.
Photometric Data
Accessories
Cordsets
Brackets
Other Accessories
- PSW-24-1
- 24 V DC, 1 A Class 2 UL Listed power supply
- 100 V AC to 240 V AC 50/60 Hz input
- 2 m (6.5 ft) PVC cable with M12 quick disconnect
- Includes Type A (US, Canada, Japan, Puerto Rico, Taiwan), Type C (Germany, France, South Korea, Netherlands, Poland, Spain, Turkey), Type G (United Kingdom, Ireland, Singapore, Vietnam), and Type I (China, Australia, New Zealand) AC detachable input plugs
- ACC-CAP M12-10
- 10 Caps
- Seal and protect exposed, unterminated cascade quick-disconnect connectors
Banner Engineering Corp Limited Warranty
Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.
Banner Engineering Corp. reserves the right to change, modify or improve the
design of the product without assuming any obligations or liabilities relating
to any product previously manufactured by Banner Engineering Corp. Any misuse,
abuse, or improper application or installation of this product or use of the
product for personal protection applications when the product is identified as
not intended for such purposes will void the product warranty. Any
modifications to this product without prior express approval by Banner
Engineering Corp will void the product warranties. All specifications
published in this document are subject to change; Banner reserves the right to
modify product specifications or update documentation at any time.
Specifications and product information in English supersede that which is
provided in any other language. For the most recent version of any
documentation, refer to:
www.bannerengineering.com.
For patent information, see
www.bannerengineering.com/patents.
October 17, 2023, © Banner Engineering Corp. All rights reserved.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>