VOLTCRAFT 2793312 Endoscope Camera VGA Flexcam Instructions
- June 15, 2024
- VOLTCRAFT
Table of Contents
VOLTCRAFT 2793312 Endoscope Camera VGA Flexcam Instructions
ENDOSCOPE CAMERA VGA FLEXCAM SF/LF
Item No.: 2793312 (2m / 5.5mm)
Item No.: 2793313 (5m / 5.5mm)
Item No.: 2793314 (10m – spool / 5.5mm)
Item No.: 2793315 (1m / 5.5mm)
Item No.: 2793316 (1m/ 5.5mm)
Item No.: 2793317 (2m / 5.5mm)
1. Intended use
This product serves as a camera attachment for endoscopes BS-1000T (both not
included in delivery) for visual fault tracing or inspection with dead-voltage
systems and equipment. The product is especially suitable for inspecting
pipes.
The flexible camera neck allows the camera at the top to be positioned so it
can reach into otherwise inaccessible locations. The twenty LEDs built into
the camera head enable shooting in total darkness, with brightness controlled
via the connected endoscope. The waterproof camera neck and camera head are
suitable for fluids (no acids or lyes).
Use on humans or animals, or in explosive areas, is not permitted. Power is
supplied via the connected endoscope.
For safety and approval purposes, you must not rebuild and/or modify this
product. If you use the product for purposes other than those described above,
the product may be damaged. In addition, improper use can cause hazards such
as short circuiting, fire, electric shock etc. Read the instructions carefully
and keep them. Make this product available to third parties only together with
its operating instructions.
This product complies with the statutory national and European requirements.
All company names and product names are trademarks of their respective owners.
All rights reserved.
2. Delivery content
Endoscope camera
Protective cap
Operating instructions
3 Latest product information
Download the latest product information at www.conrad.com/downloads or scan the QR code shown. Follow the instructions on the website.
4. Description of symbols
The symbol warns of hazards that can lead to personal injury.
5. Safety instructions
Read the operating instructions carefully and especially observe the safety information. If you do not follow the safety instructions and information on proper handling in this manual, we assume no liability for any resulting personal injury or damage to property. Such cases will invalidate the warranty/guarantee.
5.1 Persons / Product
-
Only immerse the camera head and camera neck in liquids that are voltage free.
-
The connection socket must not come in contact with fluids.
-
The endoscope may only be used for inspection of dead systems.
-
The camera head is made of metal and can lead to short circuits.
-
For safety reasons, disconnect all system parts from the power supply before every inspection.
-
Put the protective cap back onto the camera lens when the camera is no longer in use
-
The device is not a toy. Keep it out of the reach of children and pets.
-
Do not leave packaging material lying around carelessly. These may become dangerous playing material for children.
-
Protect the product from extreme temperatures, direct sunlight, strong jolts, flammable gases, vapours and solvents.
-
Do not place the product under any mechanical stress.
-
If it is no longer possible to operate the product safely, take it out of operation and protect it from any accidental use. Safe operation can no longer be guaranteed if the product:
– is visibly damaged,
– is no longer working properly,
– has been stored for extended periods in poor ambient conditions or
– has been subjected to any serious transport-related stresses. -
Please handle the product carefully. Jolts, impacts or a fall even from a low height can damage the product.
-
Also observe the safety and operating instructions of any other devices which are connected to the product.
-
On industrial sites, the accident prevention regulations of the association of the industrial workers’ society for electrical equipment and utilities must be followed.
-
Never switch the device on immediately after it has been taken from a cold into a warm environment. Condensation that forms might destroy your device. Allow the device to reach room temperature before switching it on.
5.2 Miscellaneous
Consult an expert when in doubt about operation, safety or connection of the
device.
Maintenance, modifications and repairs are to be performed exclusively by an
expert or at a qualified shop.
If you are not sure about the correct connection or use, or if questions arise
which are not covered by these operating instructions, please do not hesitate
to contact our technical support or another qualified specialist.
6. Product
Important:
– Make sure you never go below the minimum bending radius of 5 cm.
– The camera neck is not to be submerged further than the marking “MAX Water
Level”.
- Plug the connecting plug on the top of the endscope carefully into the connecting socket of the camera neck.
- Make sure that the connecting socket is oriented exactly towards the pins of the connecting plug. There is an arrow printed on the connecting socket. This arrow must point towards the display of the endoscope.
- Turn the mounting ring clockwise to fasten the connection.
- Remove the protective cap before starting to use the endoscope camera.
- Switch the endoscope on.
- You will find notes on controlling the brightness of the LEDs in the operating instructions of the manual.
- After use, switch the endoscope off and disconnect the endoscope camera from the endoscope.
- Turn the mounting ring counterclockwise and carefully disconnect the plug connection.
7. Cleaning and care
Important:
– Do not use aggressive cleaning agents, rubbing alcohol or other chemical
solutions. They damage the housing and can cause the product to malfunction.
– Do not immerse the product in water.
- The product requires no servicing on your part aside from cleaning.
- To clean the camera lens, use a small brush or cotton swab.
- Use a soft, anti-static and lint-free cloth.
- Leave the endoscope camera to dry before putting the protective cap on.
8. Disposal
This symbol must appear on any electrical and electronic equipment placed on the EU market. This symbol indicates that this device should not be disposed of as unsorted municipal waste at the end of its service life.
Owners of WEEE (Waste from Electrical and Electronic Equipment) shall dispose
of it separately from unsorted municipal waste. Spent batteries and
accumulators, which are not enclosed by the WEEE, as well as lamps that can be
removed from the WEEE in a non-destructive manner, must be removed by end
users from the WEEE in a non-destructive manner before it is handed over to a
collection point.
Distributors of electrical and electronic equipment are legally obliged to
provide free take-back of waste. Conrad provides the following return options
free of charge (more details on our website):
- in our Conrad offices
- at the Conrad collection points
- at the collection points of public waste management authorities or the collection points set up by manufacturers or distributors within the meaning of the ElektroG
End users are responsible for deleting personal data from the WEEE to be disposed of.
It should be noted that different obligations about the return or recycling of WEEE may apply in countries outside of Germany.
9. Technical data
Suitable for………………………………BS-1000T
Camera Ø………………………………..5.5 mm
Field of view……………………………..65°
Resolution (dynamic, static)……….640 x 480 px
White balance…………………………..automatic
Camera lighting………………………..20 LEDs; 1200 ±10 % Lux at 20 mm
Bend radius……………………………..>5 cm
Operating conditions………………….-20 to +60 °C, max. 95 % RH (non-condensing)
Storage conditions…………………….-20 to +60 °C, max. 95 % RH (non-condensing)
Protection class………………………..IP67 (camera, camera neck)
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication represents the technical status at the time of printing.
Copyright 2023 by Conrad Electronic SE.
Read More About This Manual & Download PDF:
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>