VOLTCRAFT BS-310X WiFi Endoscope Instruction Manual
- June 1, 2024
- VOLTCRAFT
Table of Contents
- VOLTCRAFT BS-310X WiFi Endoscope
- Product Information
- Product Usage Instructions
- Introduction
- Operating Instructions for download
- Intended use
- Package contents
- Features and functions
- Safety information
- Product overview
- Operation
- Operating the endoscope
- Using the app
- Care and cleaning
- Disposal
- Technical data
- Frequently Asked Questions (FAQ)
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
VOLTCRAFT BS-310X WiFi Endoscope
Product Information
Specifications
- Model: BS-310XWIFI
- Item No.: 1544027
- Resolution: High definition
- Connection: Wi-Fi
- Display: LC-Display
- Zoom: 1.0x, 1.5x, 2.0x
Product Usage Instructions
Getting Started
To begin using the Endoscope BS-310XWIFI, follow these steps:
- Insert or replace batteries as per instructions.
- Download the accompanying app from the provided link.
- Establish a Wi-Fi connection between the endoscope and your device.
Basic Operations
To operate the endoscope, use the following basic functions:
- Use the buttons on the endoscope for direct control.
- Turn off the endoscope when not in use to save battery power.
- Interact with the on-screen buttons for additional functions.
Display Symbols
The LC-Display of the endoscope may show the following symbols:
- Wi-Fi connection status
- Zoom level indication
App Functions
The accompanying app provides various functions:
- iVideoApp/cache for storage management
- iVideoApp/photo for capturing images
- iVideoApp/video for recording videos
Care and Maintenance
Proper care and regular cleaning of the endoscope are essential for its
longevity.
Disposal
Follow local regulations for the disposal of the product and batteries.
Introduction
Dear customer,
Thank you for purchasing this product.
This product complies with the statutory national and European requirements.
To maintain this status and to ensure safe operation, you as the user must
observe these operating instructions!
These operating instructions are part of this product. They contain important notes on commissioning and handling. Also consider this if you pass on the product to any third party. Therefore, retain these operating instructions for reference!
If there are any technical questions, please contact: www.conrad.com/contact
Operating Instructions for download
Use the link www.conrad.com/downloads (alternatively scan the QR code) to download the complete operating instructions (or new/current versions if available). Follow the instructions on the web page.
Explanation of symbols
The symbol with an exclamation mark in a triangle is used to highlight important information in these operating instructions. Always read this information carefully.
The arrow symbol indicates special information and advice on how to use the
product.
Intended use
This endoscope is a visual aid for troubleshooting and inspecting facilities and appliances that do not carry a voltage. The camera image is displayed on a built-in TFT monitor. The brightness of the light on the top of the camera can be adjusted in stages. Photos and videos can be sent, displayed and saved on mobile devices via Wi-Fi. The gooseneck camera is waterproof and suitable for use in aqueous liquids (not acids or alkalis). The base unit must not be exposed to moisture or immersed in liquids. The product is powered by four AA batteries (not included). The endoscope must not be used in areas that are at risk of explosion or for inspecting people and animals.
For safety and approval purposes, you must not rebuild and/or modify this
product. Using the product for purposes other than those described above may
damage the product. In addition, improper use can cause hazards such as a
short circuit or fire. Read the instructions carefully and store them in a
safe place. Only make this product available to third parties together with
its operating instructions.
All company and product names are trademarks of their respective owners. All
rights reserved.
Package contents
- Endoscope
- 3x attachments (magnet, hook, mirror)
- Storage case
- Operating instructions
Features and functions
- Endoscope with goose neck
- Ergonomic pistol grip for easy handling
- Wireless image transfer to mobile devices over encrypted Wi-Fi network (with app)
- Compatible with Android and Apple® mobile devices
Safety information
Read the operating instructions and safety information carefully. If you do not follow the safety instructions and information on proper handling in this manual, we will assume no liability for any resulting personal injury or damage to property. Such cases will invalidate the warranty/guarantee.
General information
- This product is not a toy. Keep it out of the reach of children and pets.
- Do not leave packaging material lying around carelessly, as it may become dangerous playing material for children.
- Protect the product from extreme temperatures, direct sunlight, strong jolts, high humidity, moisture, flammable gases, vapours and solvents.
- Do not place the product under any mechanical stress.
- If it is no longer possible to operate the product safely, stop using it and prevent unauthorized use. Safe operation can no longer be guaranteed if the product:
- is visibly damaged,
- is no longer working properly,
- has been stored for extended periods in adverse ambient conditions or
- has been subjected to any serious transport-related stress.
- Always handle the product carefully. Jolts, impacts or a fall even from a low height may damage the product.
- Always observe the safety and operating instructions of any other devices which are connected to the product.
- Consult a technician if you are not sure how to use or connect the product.
- Maintenance, modifications and repairs must be done by a technician or a specialist repair centre.
- If you have questions which remain unanswered by these operating instructions, contact our technical support service or other technical personnel.
- Warning, LED light:
- Do not look directly at the LED light!
- Do not look into the beam directly or with optical instruments!
Persons and product
- This product is a precision instrument. Do not drop it or expose it to impacts.
- The base unit is not waterproof and therefore cannot be immersed under water.
- The endoscope must only be used to inspect facilities that are not connected to a power source. The camera head is made from metal and can lead to short circuits.
- For safety reasons, turn off all power sources before each inspection.
- When you are not using the endoscope, always place the endoscope and its accessories in the case.
- Sensitive surfaces (e.g. with furniture polish) may react chemically with the housing.
- Avoid heavy mechanical loads and vibrations.
- Do not use the product if condensation forms on the camera lens. Wait until the condensation has evaporated.
- Always comply with the accident prevention regulations for electrical equipment when using the product in industrial facilities.
- Never use the device immediately after it has been brought from a cold room into a warm one. The condensation generated may destroy the product in adverse conditions. Leave the device switched off and allow it to reach room temperature.
- Read the safety information in each section of these operating instructions and in the instruction manuals of any connected mobile devices.
Batteries
- Ensure that you insert the batteries in the correct polarity.
- To prevent battery leakage, remove the batteries when you do not plan to use the product for an extended period. Leaking or damaged batteries may cause acid burns if they come into contact with your skin. Always use suitable protective gloves when handling damaged batteries.
- Batteries must be kept out of the reach of children. Do not leave batteries lying around, as there is a risk that children or pets may swallow them.
- All batteries must be replaced at the same time. Mixing old and new rechargeable batteries can cause the batteries to leak and damage the product.
- Batteries must not be dismantled, short-circuited or thrown into fire. Never recharge non-rechargeable batteries, as this may cause an explosion.
Miscellaneous
- This product is not suitable for medical or commercial use.
Product overview
- Camera LEDs
- Gooseneck
- Eyelet
- LCD display
- Wi-Fi button
- Battery compartment screw
- Battery compartment cover
- Brightness button
- Camera button (photos)
- On/off button
- Video button (filming)
- RESET button (hidden)
- Camera
Operation
Inserting/changing the batteries
- Loosen the battery compartment screw (6) with a Phillips screwdriver, and then remove the battery compartment cover (7).
- Remove the battery holder from the battery compartment.
- Insert four AA batteries in the battery compartment. Pay attention to the polarity markings inside the battery holder.
- Place the battery holder back into the battery compartment. Pay attention to the polarity markings on the top of the battery holder and inside the battery compartment. The protruding tab on the battery holder should point upwards.
- Replace the battery compartment cover (7) and secure it in place with the screw using moderate force. Replace the batteries when the battery symbol on the LCD display (4) indicates a low battery level.
Operating the endoscope
Only hold the camera head and gooseneck in liquids that are not connected to a power source. The gooseneck must not be submerged beyond the “IP67 MAX Water Level” mark. The endoscope must only be used to inspect facilities that are not connected to a power source. The camera head is made from metal and can lead to short circuits. For safety reasons, turn off all power sources before each inspection. Avoid heavy mechanical loads and vibrations. The minimum bending radius of the gooseneck must not be less than 45 mm.
Attachments
- If required, fix one of the three attachments (magnet, mirror or hook) to the narrow slot underneath the camera head.
- Check that the ring on the attachment is closed before use.
Eyelet
- An eyelet (3) is attached to the top of the monitor. You can attach a carrying strap (not included) to the eyelet to free up your hands when you are using the endoscope.
Basic functions of the endoscope
The following functions can be controlled using the keypad on the endoscope.
Viewing images
- Place the camera and gooseneck next to the object that you want to inspect and carefully move them to the desired position. Avoid inspecting moving parts or equipment that you may touch unintentionally. Turn off such equipment beforehand.
If it is not possible to switch off the equipment, using the endoscope to inspect such equipment may damage the endoscope or the equipment itself.
Switching the endoscope on/off
- Press the on/off button (10) to switch the endoscope on. After a short startup interval, the camera image will appear on the monitor.
- Press the on/off button (10) to switch the endoscope off. The monitor will switch off.
After you have finished using the endoscope, switch it off immediately to conserve battery power.
Interrupting/re-establishing a Wi-Fi connection.
- Press the Wi-Fi button (5) to interrupt an existing Wi-Fi connection between the endoscope and a mobile device.
- Press the Wi-Fi button (5) to re-establish the Wi-Fi connection between the endoscope and your mobile device.
- You may need to restart the real-time display in the app. See “d) Onscreen buttons” for details.
- For details on how to set up a Wi-Fi connection, see “10. Using the app b) Establishing a Wi-Fi connection”.
Setting the brightness
- The camera head features four built-in LEDs. Press the brightness button (8) to adjust the brightness of the LEDs and turn the light on/off. The brightness is indicated in percent in the upper-right corner of the LCD display (4).
- Adjust the brightness so that the image displayed on the monitor is not over- or underexposed.
Photo and video functions
- Press the camera button (9) to take a photo.
- Press the video button (11) once to start recording a video.
- Press the video button (11) again to stop the recording.
The endoscope must be connected to the app via Wi-Fi in order to take photos and videos. If the endoscope is not connected to the app, these buttons (9 and
- have no function. The video will be saved to an automatically-generated folder on your mobile device. See “10. Using the app” for details.
Restoring the endoscope to factory settings
Restore the factory settings if you want to rename your network or when you
forget your password.
- To restore factory settings, press the RESET button (12) on the back of the endoscope. For best results, use a straightened paper clip. You will feel a slight click when you press the button. The endoscope will switch off automatically when factory settings have been restored. The Wi-Fi network password will be reset to the factory default.
LCD display symbols
Using the app
Installing the app
- Download the Voltcraft Wi-Fi ScopeCam app from the Google Play store (for Android® devices) or the Apple App Store (for Apple® mobile devices).
- Follow the onscreen prompts to install the app.
- Complete the installation process.
Establishing a Wi-Fi connection
- The endoscope creates a Wi-Fi network when it is switched on. After connecting to this network with your mobile device, you can operate and control the endoscope with the mobile app.
- Press the on/off button (10) to switch the endoscope on. After a short startup interval, the camera image will appear on the monitor.
- Enable Wi-Fi on your mobile device and follow the onscreen prompts.
- Select isnakescope view from the list of available Wi-Fi networks and touch to confirm.
- You will be prompted to enter the password. Enter “12345” and confirm your entry.
- The Wi-Fi connection will be established.
You can change the Wi-Fi password in the mobile app.
App functions
- The app creates folders during the installation process. Photos and videos are automatically saved to these folders. The following folders are created automatically:
- iVideoApp/cache
- iVideoApp/photo
- iVideoApp/video
- Launch the mobile app to configure the settings and access all of the endoscope functions. The user interface with the camera image will be displayed (see right-hand screenshot).
Onscreen buttons
Use the onscreen buttons in the menu bar at the top and bottom of the
touchscreen to control the endoscope functions. You can also view photos and
videos.
Care and cleaning
Never use aggressive detergents, rubbing alcohol or other chemical solutions, as these could damage the casing or stop the product from functioning properly.
- The endoscope does not require maintenance except for occasional cleaning. Use a soft, antistatic, lint-free cloth to clean the product.
- Carefully rinse the gooseneck camera with clean water after using it in liquids and dry it before storing it in the case.
- Use a small brush or a cotton bud to clean the camera lens.
Declaration of Conformity (DOC)
Conrad Electronic SE, Klaus-Conrad-Straße 1, D-92240 Hirschau hereby declares that this product conforms to the 2014/53/EU directive.
- Click on the following link to read the full text of the EU declaration of conformity: www.conrad.com/downloads
Enter the product item number in the search box. You can then download the EU declaration of conformity in the available languages.
Disposal
Product
This symbol must appear on any electrical and electronic equipment placed on the EU market. This symbol indicates that this device should not be disposed of as unsorted municipal waste at the end of its service life.
Owners of WEEE (Waste from Electrical and Electronic Equipment) shall dispose of it separately from unsorted municipal waste. Spent batteries and accumulators, which are not enclosed by the WEEE, as well as lamps that can be removed from the WEEE in a non-destructive manner, must be removed by end users from the WEEE in a non-destructive manner before it is handed over to a collection point.
Distributors of electrical and electronic equipment are legally obliged to provide free take-back of waste. Conrad provides the following return options free of charge (more details on our website):
- in our Conrad offices
- at the Conrad collection points
- at the collection points of public waste management authorities or the collection points set up by manufacturers or distributors within the meaning of the ElektroG
End users are responsible for deleting personal data from the WEEE to be
disposed of.
It should be noted that different obligations about the return or recycling of
WEEE may apply in countries outside of Germany.
(Rechargeable) batteries
Remove batteries/rechargeable batteries, if any, and dispose of them
separately from the product. According to the Battery Directive, end users are
legally obliged to return all spent batteries/rechargeable batteries; they
must not be disposed of in the normal household waste.
Batteries/rechargeable batteries containing hazardous substances are labelled with this symbol to indicate that disposal in household waste is forbidden. The abbreviations for heavy metals in batteries are: Cd = Cadmium, Hg = Mercury, Pb = Lead (name on (rechargeable) batteries, e.g. below the trash icon on the left).
Used (rechargeable) batteries can be returned to collection points in your
municipality, our stores or wherever (rechargeable) batteries are sold. You
thus fulfil your statutory obligations and contribute to environmental
protection.
Batteries/rechargeable batteries that are disposed of should be protected
against short circuit and their exposed terminals should be covered completely
with insulating tape before disposal. Even empty batteries/rechargeable
batteries can contain residual energy that may cause them to swell, burst,
catch fire or explode in the event of a short circuit.
Technical data
- Operating voltage ………………………………………4 x 1.5 V AA batteries (not included)
- Current consumption ………………………………….Max. 350 mA
- Protection rating ………………………………………..IP67 (gooseneck and camera only)
- Camera sensor ………………………………………….4.82 (1/9″) VGA, CMOS
- Display ……………………………………………………..6.85 cm (2.7″) TFT
- Resolution …………………………………………………960 x 240 pixels (display), 640 x 480 pixels (camera)
- Video format ……………………………………………..MJPG
- Frame rate ………………………………………………..30 fps
- Photo format ……………………………………………..JPG
- Camera light ……………………………………………..4 LEDs (max. 1200 ±150 lx at a distance of 20 mm)
- White balance ……………………………………………Automatic
- Exposure ………………………………………………….Automatic
- Field of view ………………………………………………54º
- Depth of field …………………………………………….3–6 cm
- Battery life …………………………………………………4 hours (with new batteries)
- Gooseneck length ………………………………………88 ±2 cm
- Camera Ø …………………………………………………8 ±0.1 mm
- Bending radius …………………………………………..Min. 45 mm
- Supported Wi-Fi standards ………………………….IEEE802.11 b/g/n
- Encryption protocol …………………………………….WPA2 PSK (with password)
- Transmission power……………………………………802.11b: 15 ±2 dBm (normal), 802.11g: 10 ±2 dBm (normal)
- Wi-Fi range ……………………………………………….Max. 20 m (with no obstructions)
- Frequency …………………………………………………2.412 – 2.484 GHz
- Compatible with ………………………………………… iPad Series / iPhone 3GS, 4, 4S, 5, 5S, 5C with iOS4.1 or higher, Android mobile devices with Android OS 2.3.5 or higher
- Operating conditions …………………………………..0 to +45 °C, 15–85 % relative humidity (non-condensing)
- Storage conditions ……………………………………..-10 to +50 °C, 15–85 % relative humidity (non-condensing)
- Dimensions (W x H x D) ……………………………..116 (±2 cm) x 13.2 x 3.6 cm
- Weight ……………………………………………………..279 g
Compatible accessories
Accessories are available from www.conrad.com.
Frequently Asked Questions (FAQ)
How do I change the batteries in the endoscope?
Refer to section 9a in the operating instructions for detailed steps on inserting or replacing batteries.
Can I connect the endoscope to multiple devices simultaneously?
No, the endoscope can only establish a Wi-Fi connection with one device at a time.
What should I do if the Wi-Fi connection is unstable?
Check the Wi-Fi signal strength and proximity to the device. Ensure there are no interferences causing disruption.
References
- Conrad Electronic » Alle Teile des Erfolgs
- Conrad Electronic » All parts of success
- Contact
- Conrad Electronic » All parts of success
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>