INSTALLATION LED POWER SUPPLY – QOM-eLED-ND-PS

Housing

Q TRAN QOM eLED ND PS LED Power Supply -

Mounting Options

Q TRAN QOM eLED ND PS LED Power Supply - Mounting
Options

NOTE: To order additional lengths of wire for connection in the secondary
Please call factory for availability.
: QOM must be installed as shown.

Driver with no Dimming Module

QOM-eLED
: for exterior

Q TRAN QOM eLED ND PS LED Power Supply - Module

Swimming Pool Installation

REGULATIONS
In accordance with the requirements of NEC680 regulation in the United States, when an illumination light is installed in the swimming pool, the distance from the bottom of the terminal box to the ground shall be no less than 4 inches. The vertical distance to the water surface of the swimming shall not be less than 8 inches, and the horizontal distance to the water edge of the swimming pool shall not be less than 48 inches.
REQUIREMENT FOR POWER SUPPY
Please use only an isolating low voltage power supply with ungrounded output, evaluated for swimming pool use.

Q TRAN QOM eLED ND PS LED Power Supply - Module1

For swimming pool, the embedded installation is strongly suggested so as to secure the swimmers’ safety and avoid the damage to lights, so a slot for implanting profiles should be prepared on mounting surface first, suggested slot sizes: 0.95” in width, 0.98” in depth.
All the fundamental constructions, including the installation of junction box and switch, cable bushing and laying, the digging of slots, etc., should be done before the light installation.

CSA Requirements

  • Power unit for use with Fountain, Swimming Pool, and Spa Luminaires
  • Suitable for indoor and outdoor use
  • This power supply must be installed according to the National Electric Code and local codes and ordinances and in accordance with applicable installation code by a person familiar with the construction and operation of the product and the hazards involved.
  • Wear rubber shoes and work on a sturdy wooden or fiberglass ladder.
  •  This power supply is to be installed in a location where it is not likely to be contacted by non-electricians.
  •  To avoid a hazard to children, account for all parts and destroy all packaging materials.
  •  Keep enclosure cover covered.
    Q TRAN QOM eLED ND PS LED Power Supply - CSA