CNC4PC THC-3 Plasma Torch Height Control User Manual
- June 9, 2024
- CNC4PC
Table of Contents
CNC4PC THC-3 Plasma Torch Height Control User Manual
OVERVIEW
This module allows you to control the height of the plasma torch head relative to the workpiece during plasma CNC operation, it supports either raw torch head voltage or input of 0-10VDC, the ARC OK, UP and DOWN outputs are isolated.
FEATURES
- Open collector to optoisolated output working at 5 to 24VDC
- Built-in Voltage Divider for connecting to the voltage on the torch or can use the 0-10VDC from a voltage divider from the plasma.
- Bluetooth connection
- 10 to 30VDC Power Terminal (+24 Typical)
- Isolated Power Connection
- Status LED
- Din Rail Mountable.
- Divider input (16:1 – 20:1 – 40:1 – 50:1 – 1:1)
DESCRIPTION
TERMINAL BOARD
POWER
Requires a 10 to 30VDC at 100mA Power Supply. Typically, +24vdc are used. “This board is electrically isolated through a DC-DC converter.”
WARNING: Check the polarity and voltage of the external power source and connect the 10VDC to 30VDC and GND. Overvoltage or reverse-polarity power applied to these terminals can cause damage to the board, and/or the power source.
4.2 DIVIDED INPUT (16:1 – 20:1 – 40:1 – 50:1 – 1:1)
TORCH VOLTAGE
NOTE:
It is preferable to use the divided voltage instead of the torch voltage. The
Torch voltage can be very high and there could be many safety implications in
wiring this to the controller. The high voltage could also be a possible
source of noise. Use it as a last resource.
OUTPUT SIGNALS
Voltage applied can be from 5 to 80VDC@50mA, outputs signal optoisolated Open
Collector.
PAIRING DEVICE
Setting up a CNC4PC THC-3 Torch Height Controller UCCNC Configuration for THC-3
Add device THC-3
UCCNC CONFIGURATION
CCNC Configuration for THC-3 on C76 or C94
Used software: UCCNC Version 1.2115
http://www.cncdrive.com/UCCNC/setup_1.2115.exe
STEP 1:
Start by making a backup of the existing installation:
Make a backup of the configuration and file installation, we recommend
creating a backup of the current installation by right-clicking in the current
installation folder and zipping it.
STEP 3:
Modbus Configurations:
Control Panel\All Control Panel Items\Devices and Printers
NOTE:
The COM port that windows assigned, as it would need to be set in the Modbus
configuration.
STEP 4:
Download, install and the new screen and macro files:
Download the compressed file containing the macros and screen that work with
the macros:
https://www.cnc4pc.com/pub/media/productattachments/files/UCCNC_THC-3_2.zip
You will need to install the screen found in the download folder and place the
macro in the macros directory for the profile folder.
Make a backup of the original M3 and M5 macros by zipping them into the same
folder, just so you may have access to the original macros if you need to
revert the installation later. Then replace the M3 and M5 macros for the
profile you are configuring:
STEP 5:
Configure the new Plasma Screen:
Set UCCNC to use the new screen that you just copied:
STEP 6:
Configure the macroloop:
STEP 7:
STEP 8:
These wiring samples for connection can be used:
https://www.cnc4pc.com/blog/post/connection-c76-and-thc-3-with-powermax-45
STEP 9:
Configure Torch Relay:
STEP 10:
Configure the THC pins:
SCREEN DESCRIPTION
SET POINT
Is the target voltage to be achieved.
ARC VOLTAGE
Limit from 40 to 400VDC, True Voltage measured for the plasma.
V-RANGE (HY)
Is the tolerance or (+/-) voltage range used to generate an adjustment. The torch height is not commanded to adjust if the true voltage is within side the specified range. It can be between 2 to 32VDC.
THC DELAY
Torch motion starts the number of seconds you set as DT after the ARC signal
is determined. This can be a value between 0.1 to 9.9 seconds.
TEST MODE
- Select test mode button on the screen, the test led will turn on.
- In test mode select DN or UP to make the spindle move. The LED will turn on according to the direction.
- To exit test mode, Press the test mode button again.
- Z-axis correction will start after the DT seconds you set after the ACR OK signal is sensed.
- Test Mode is to simulate the signals coming from the THC unit. This can be used to test the wiring and configuration to make the unit can read the signals sent.
WAIRING SAMPLE
THC-3 Plasma Torch Height
TERMINAL| WIRE CABLE| CONNECTION
ARC OK| | INP. PORT2 – PIN13
COM| | GND
DOWM| | INP. PORT2 – PIN11
UP| | INP. PORT2 – PIN12
GND| | GND
10 – 30VDC| | 24VDC
CONNECTOR| RELAY 2| THC-3 DIVIDED INPUT
---|---|---
PIN 3| VIN|
PIN 4| NO|
PIN 5| | GND
PIN 6| | 50:1
Disclaimer:
Use caution. CNC machines can be dangerous machines. Neither DUNCAN USA, LLC
nor Arturo Duncan is liable for any accidents resulting from the improper use
of these devices. This product is not a fail-safe device and it should not be
used in life support systems or in other devices where its failure or
possible erratic operation could cause.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>