MEAN WELL HBG-200 Series Constant Voltage Constant Current LED Driver Owner’s Manual
- June 13, 2024
- MEAN WELL
Table of Contents
- 200W Constant Voltage + Constant Current LED Driver
- HBG-200 series
- Features
- Applications
- GTIN CODE
- Description
- Model Encoding
- BLOCK DIAGRAM
- DRIVING METHODS OF LED MODULE
- DIMMING OPERATION
- OUTPUT LOAD vs TEMPERATURE(Note.11)
- STATIC CHARACTERISTIC
- POWER FACTOR (PF) CHARACTERISTIC
- TOTAL HARMONIC DISTORTION (THD)
- EFFICIENCY vs LOAD
- LIFETIME
- MECHANICAL SPECIFICATION
- INSTALLATIONS
- INSTALLATION MANUAL
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
200W Constant Voltage + Constant Current LED Driver
HBG-200 series
Features
- Constant Voltage + Constant Current mode output
- Circular metal housing with class I design
- Built-in active PFC function
- IP67 / IP65 rating for indoor or outdoor installations
- Function options: output adjustable via potentiometer; 3 in 1 dimming; DALI
- Typical lifetime>50000 hours
- 5 years warranty
Applications
- LED high/low bay lighting
- LED canopy lighting
- LED stage lighting
- LED spot lighting
- Outdoor architectural lighting system
- Type “HL” for use in Class I, Division 2 hazardous (Classified) location.
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
Description
HBG-200 series is a 200W AC/DC LED driver featuring the circular shape design. It operates from 90~305VAC and offers the dual modes constant voltage and constant current output models with different rated voltage between 36Vand 60V. Thanks to the high efficiency up to 93.5%,with the fanless design, the entire series is able to operate for -40°C ~ +85°C case temperature under free air convection. The design of metal housing and IP67/1P65 ingress protection level allows this series to fit both indoor and outdoor applications. HBG-200 is equipped with various function options, such as dimming methodologies, so as to provide the optimal design flexibility for LED lighting system.
Model Encoding
- Function mode option
- Rated output voltage(36/48/60V)
- Rated wattage
- Series name
Type | IP Level | Function | Note |
---|---|---|---|
Blank | IP67 | lo fixed. | In Stock |
A | IP65 | lo adjustable through built-in potentiometer. | In Stock |
B | IP67 | 3 in 1 dimming function (0-10Vdc, 10V PWM signal and resistance) | In |
Stock
AB| IP65| lo adjustable through built-in potentiometer with 3 in 1 dimming
function| In Stock
DA| IP67| DALI control technology.| In Stock
SPECIFICATION
MODEL | HBG-200-36 | HBG-200-48 | HBG-200-60 |
---|---|---|---|
OUTPUT | DC VOLTAGE | 36V | 48V |
CONSTANT CURRENT REGION Note.2 | 21.6 ~ 36V | 28.8 ~ 48V | 36 ~ 60V |
RATED CURRENT | 5.5A | 4.1A | 3.3A |
RATED POWER | 198W | 196.8W | 198W |
RIPPLE & NOISE (max.) Note.3 | 250mVp-p | 250mVp-p | 350mVp-p |
CURRENT ADJ. RANGE | Adjustable for A-Type and AB-Type (via built-in |
potentiometer)
3.3 ~ 5.5A| 2.46 ~ 4.1A| 1.98 ~ 3.3A
VOLTAGE TOLERANCE Note.4| ±2.0%
LINE REGULATION| ±0.5%
LOAD REGULATION| ±1.0%
SETUP, RISE TIME Note.6| 2500ms,200ms /115VAC 500ms,200ms /230VAC
HOLD UP TIME (Typ.)| 12ms /115VAC, 230VAC
INPUT| VOLTAGE RANGE Note.5| 90 ~ 305VAC 127~417VDC
(Please refer to “STATIC CHARACTERISTIC” section)
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR| PF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC@full load
(Please refer to “POWER FACTOR (PF) CHARACTERISTIC” section)
TOTAL HARMONIC DISTORTION| THD< 20%(@load≧60%/115VC,230VAC;
@load≧75%/277VAC)
(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)
EFFICIENCY (Typ.)| 92%| 93%| 93.5%
AC CURRENT (Typ.)| 1.9A / 115VAC 1A / 230VAC 0.9A / 277VAC
INRUSH CURRENT (Typ.)| COLD START 85A(twidth=600μs measured at 50%
Ipeak) at 230VAC; Per NEMA 410
MAX. No. of PSUs on 16A
CIRCUIT BREAKER| 4 units (circuit breaker of type B) / 7 units (circuit
breaker of type C) at 230VAC
LEAKAGE CURRENT| <0.75mA / 277VAC
NO LOAD / STANDBY POWER CONSUMPTION| Standby power consumption <0.5W for
B/AB/DA-Type
Blank/A-Type please refer to Note.8
PROTECTION| OVER CURRENT| 95~108%
Constant current limiting, recovers automatically after fault condition is
removed
SHORT CIRCUIT| Hiccup mode or constant current limiting, recovers
automatically after fault condition is removed
OVER VOLTAGE| 41 ~ 47V | 54 ~ 62V| 65 ~ 75V
Shut down o/p voltage with auto-recovery or re-power on to recovery
OVER TEMPERATURE| Shut down o/p voltage, recovers automatically after
temperature goes down
ENVIRONMENT| WORKING TEMP.| Tcase=-40 ~ +85℃ (Please refer to “
OUTPUT LOAD vs TEMPERATURE” section)
MAX. CASE TEMP.| Tcase=+85℃
WORKING HUMIDITY| 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X,
Y, Z axes
SAFETY & EMC| SAFETY STANDARDS| UL8750(type”HL”),CSA C22.2
No.250.13-12,ENEC BS EN/EN61347-1,BS EN/EN61347-2-13 independent, BS
EN/EN62384; GB19510.14, GB19510.1; EAC TP TC 004,IP65 or IP67 approved
DALI STANDARDS| Compliance to IEC62386-101, 102, 207 for DA type only
WITHSTAND VOLTAGE| I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/
70% RH
EMC EMISSION| Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C
(@load≧60%) ; BS EN/EN61000-3-3; GB17625.1, GB17743,EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS
EN/EN61547,light industry level (surge immunity:Line-Earth:4KV,Line-
Line:2KV),EAC TP TC 020
OTHERS| MTBF| 2042.7K hrs min. Telcordia SR-332 (Bellcore)
;207.4K hrs min. MIL-HDBK-217F (25℃)
DIMENSION| Refer to mechanical specification
PACKING| 1.53Kg; 8pcs/13.8Kg/1.61CUFT
NOTE|
- All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25°C of ambient temperature.
- Please refer to “DRIVING METHODS OF LED MODULE”.
- Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1 uf & 47uf parallel capacitor.
- Tolerance : includes set up tolerance, line regulation and load regulation.
- De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.
- Length of set up time is measured at cold first start. Turning ON/OFF the driver may lead to increase of the set up time.
- The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
- To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED driver can only be used behind a switch without permanently connected to the mains.
- This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly point (or TMP, per DLC), is about 70°C or less.
- Please refer to the warranty statement on MEAN WELL’s website at http://www.meanwell.com
- The ambient temperature derating of 3.5°C/1000m with fanless models and of 5°C/1000m with fan models for operating altitude higher than 2000m(6500ft).
- For any application note and IP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf
Product Liability Disclaimer : For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
BLOCK DIAGRAM
fosc : 100KHz
- EMI FILTER & RECTIFIERS
- PFC CIRCUIT
- POWER SWITCHING
- RECTIFIERS & FILTER
- DETECTION CIRCUIT
- PWM & PFC CONTROL
DRIVING METHODS OF LED MODULE
This series is able to work in either Constant Current mode (a direct drive way) or Constant Voltage mode (usually through additional DC/DC driver) to drive the LEDs.
-
(A)
Constant Voltage area -
(B)
Constant Current area -
(C)
Hiccup Protection -
In the constant current region, the highest voltage at the output of the driver depends on the configuration of the end systems.
Should there be any compatibility issues, please contact MEAN WELL. -
Typical output current normalized by rated current (%)
-
Vo(%)
DIMMING OPERATION
- DIM+ for B/AB-Type
DA+ for DA-Type - *DIM- for B/AB-Type
DA- for DA-Type
- *DIM+(Purple)
- **DIM-(Pink)
- SVT 18AWG*2C
- AC/L(Brown)
- AC/N(Blue)
- FG (Green/Yellow)
- SVT 18AWG*2C
- Vo+(Red)
- Vo-(Black)
- SJTW 18AWG*2C
3 in 1 dimming function (for B/AB-Type)
– Output constant current level can be adjusted by applying one of the three
methodologies between DIM+ and DIM-: 0 ~ 10VDC, or 10V PWM signal or
resistance.
– Direct connecting to LEDs is suggested. It is not suitable to be used with
additional drivers.
– Dimming source current from power supply: 100μA (typ.)
Applying additive 0 ~ 10VDC
-
Additive Voltage
-
“DO NOT connect “DIM- to -V”
-
Output current (%)
-
Dimming input: Additive voltage
Applying additive 10V PWM signal (frequency range 100Hz ~ 3KHz):
-
Additive PWM signal
-
“DO NOT connect” DIM- to -V”
-
Output current (%)
-
Duty cycle of additive 10V PWM signal dimming input
Applying additive resistance:
-
Additive Resistance
-
“DO NOT connect” DIM- to -V”
-
Output current (%)
-
(N=driver quantity for synchronized dimming operation)
Dimming input: Additive resistance
Note :
- Min. dimming level is about 8% and the output current is not defined when 0%< Iout<8%.
- The output current could drop down to 0% when dimming input is about 0kΩ or 0Vdc, or 10V PWM signal with 0% duty cycle.
Note: In the case of turning the lighting fixture down to 0% brightness, please refer to the configuration as follow, or please contact MEAN WELL for other options.
-
10K/N~100K/N Ohms resistance
1~10V DC Voltage
10V PWM Signal -
LED Lighting Fixture
-
HBG-200
B-Type
Using a switch and relay can turn ON/OFF the lighting fixture.
DALI Interface (primary side; for DA-Type)
- Apply DALI signal between DA+ and DA-.
- DALI protocol comprises 16 groups and 64 addresses.
- First step is fixed at 8% of output.
OUTPUT LOAD vs TEMPERATURE(Note.11)
- LOAD (%)
- AMBIENT TEMPERATURE (°C)
- LOAD (%)
- Tcase (°C)
STATIC CHARACTERISTIC
- LOAD (%)
- INPUT VOLTAGE (V) 60Hz
De-rating is needed under low input voltage.
POWER FACTOR (PF) CHARACTERISTIC
Tcase at 75°C
- PF
- LOAD
TOTAL HARMONIC DISTORTION (THD)
48V Model, Tcase at 75°C
- THD
- LOAD
EFFICIENCY vs LOAD
HBG-200 series possess superior working efficiency that up to 93.5% can be
reached in field applications.
48V Model, Tcase at 75℃
- EFFICIENCY(%)
- LOAD
LIFETIME
- LIFETIME(Kh)
- Tcase (℃ )
MECHANICAL SPECIFICATION
Case No.211 Unit:mm
Blank-Type
- M10*P1.5-18h
- AC/L(Brown)
- AC/N(Blue)
- FG (Green/Yellow)
- SJTW 18AWG*3C
- SJTW 18AWG*2C
- Vo+(Red)
- Vo-(Black)
- : Max. Case Temperature.(case temperature measured point)
- Ta: Ambient Temperature measured point
A-Type
- M10*P1.5-18h
- AC/L(Brown)
- AC/N(Blue)
- FG (Green/Yellow)
- SJTW 18AWG*3C
- SJTW 18AWG*2C
- Vo+(Red)
- Vo-(Black)
- : Max. Case Temperature.(case temperature measured point)
- Ta: Ambient Temperature measured point
B/DA-Type
- M10*P1.5-18h
- DIM+ for B-Type
DA+ for DA-Type - *DIM- for B-Type
DA- for DA-Type
- *DIM+(Purple)
- **DIM-(Pink)
- SVT 18AWG*2C
- AC/L(Brown)
- AC/N(Blue)
- FG (Green/Yellow)
- SJTW 18AWG*3C
- SJTW 18AWG*2C
- Vo+(Red)
- Vo-(Black)
- : Max. Case Temperature.(case temperature measured point)
- Ta: Ambient Temperature measured point
AB-Type
- M10*P1.5-18h
- *DIM+(Purple)
- **DIM-(Pink)
- SVT 18AWG*2C
- AC/L(Brown)
- AC/N(Blue)
- FG (Green/Yellow)
- SJTW 18AWG*3C
- SJTW 18AWG*2C
- Vo+(Red)
- Vo-(Black)
- : Max. Case Temperature.(case temperature measured point)
- Ta: Ambient Temperature measured point
INSTALLATIONS
| |
---|---|---
Hanger
| Chain|
High Bay Light
Caution
Please inspect the appearance of the driver if the package is damaged. There
should not be any cracks.
Please do not drop or bump the driver.
All screws including the suspension screw should be paired with a spring
washer and locked tight.
The entire luminaire, including the driver, should be limited to 10Kg or less.
The luminaire should be cautiously protected from damage due to shock
throughout packaging and transportation.
Please thoroughly follow the preceding cautionary notes to prevent the
luminaire from falling, leading to injuries.
INSTALLATION MANUAL
Please refer to : http://www.meanwell.com/manual.html
File Name:HBG-200-SPEC 2022-03-16
Downloaded from Arrow.com.
Read User Manual Online (PDF format)