MEAN WELL LDC-35 Series 35W Constant Power MODE Linear LED Driver Owner’s Manual
- June 13, 2024
- MEAN WELL
Table of Contents
- Features
- GTIN CODE
- Model Encoding
- BLOCK DIAGRAM
- OUTPUT CURRENT SETTING
- DIMMING OPERATION
- TEMPERATURE COMPENSATION OPERATION
- OUTPUT LOAD vs TEMPERATURE
- STATIC CHARACTERISTIC
- TOTAL HARMONIC DISTORTION (THD)
- POWER FACTOR (PF) CHARACTERISTIC
- EFFICIENCY vs LOAD
- LIFE TIME
- MECHANICAL SPECIFICATION
- Installation Manual
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
MEAN WELL LDC-35 Series 35W Constant Power MODE Linear LED Driver Owner’s
Manual
Features
- Constant Power mode output
- Metal housing design
- Full Power at 70-100% max Current
- Built-in active PFC function
- Flicker Free design
- No load / Standby power consumption <0.5W
- Output current level pre-settable
- Function options: 3 in 1 dimming (dim-to-off); DALI interface, push dimming
- Typical lifetime>50000 hours
- SELV and Isolated
- Class 2 power supply
- 5 years warranty
Applications
- LED panel lighting
- Indoor LED lighting
- Linear LED lighting
GTIN CODE
MW Search : https://www.meanwell.com/serviceGTIN.aspx
Description
LDC-35 series is a 35W AC/DC LED driver featuring the constant power mode output. LDC-35 operates from 180-295VAC and output current can be adjust between 300mA to 1000mA. Thanks to the efficiency up to 88%, with the fanless design, the entire series is able to operate for -25C-+80°C case temperature under free air convection.LDC-35 is equipped with various function options, such as dimming methodologies, so as to provide the optimal design flexibility for LED lighting system.
Model Encoding
Type | Function | Note |
---|---|---|
Blank | Non dimming | In Stock |
B | 3 in 1 dimming function (0~10Vdc and10V PWM signal and resistance ) | In |
Stock
DA| DALI,push dimming| In Stock
SPECIFICATION
MODEL | LDC-35 |
---|---|
**OUTPUT** | OUTPUT CURRENT REGION |
default)
RATED POWER Note.2| 35W
CONSTANT CURRENT REGION Note.2| 27 ~ 56V
FULL POWER CURRENT RANGE| 625 ~ 1000mA
OPEN CIRCUIT VOLTAGE (max.)| 60V
LOW FREQUENCY CURRENT RIPPLE| 3.0% max. @rated current
CURRENT TOLERANCE| ±5.0%
SET UP TIME Note.4| 500ms/230VAC
INPUT| **VOLTAGE RANGE ****Note.3| 180 ~ 295VAC(Please refer
to “STATIC CHARACTERISTIC” section)
FREQUENCY RANGE| 47 ~ 63Hz
****POWER FACTOR (Typ.)| PF≧0.95/230VAC@load≧50%;
PF≧0.92/277VAC@load≧75% (Please refer to “POWER FACTOR (PF) CHARACTERISTIC”
section)
****TOTAL HARMONIC DISTORTION| THD< 10%(@load≧50%/230VAC;
@load≧75%/277VAC)(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)
EFFICIENCY (Typ.)| 88%(230VAC@Full load)
AC CURRENT (Typ.)| 0.2A / 230VAC 0.16A / 277VAC
INRUSH CURRENT (Typ.)| COLD START 30A(twidth=250μs measured at 50%
Ipeak)/230VAC; Per NEMA 410
MAX. No. of PSUs on 16A CIRCUIT BREAKER| ** 17 units (circuit breaker
of type B) / 29 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT| <0.75mA / 277VAC
**PROTECTION| SHORT CIRCUIT| Hiccup mode or constant current
limiting ,recovers automatically after fault condition is removed
****OVER VOLTAGE| 61 ~ 80V
Shut down o/p voltage with auto-recovery or re-power on to recovery
OVER TEMPERATURE| Shut down o/p voltage, with auto-recovery
FUNCTION| DIMMING| Please refer to“DIMMING OPERATION”section
TEMP. COMPENSATION| By external NTC, please refer to“TEMPERATURE
COMPENSATION OPERATION”section
****ENVIRONMENT| WORKING TEMP.| Tcase=-25 ~ +80℃ (Please refer to “
OUTPUT LOAD vs TEMPERATURE” section)
MAX. CASE TEMP.| Tcase=+80℃
WORKING HUMIDITY| 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 60℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X,
Y, Z axes
SAFETY & **EMC| SAFETY STANDARDS Note.5| UL8750, CSA C22.2
No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13, AS/NZS 61347.1,
AS/NZS IEC 61347.2.13; BS EN/EN62384; GB19510.14,GB19510.1, EAC TP TC 004, BIS
IS15885 approved
DALI STANDARDS| Compliance to IEC62386-101.102.207 for DA-Type only
WITHSTAND VOLTAGE| I/P-O/P:3.75KVAC I/P-FG:2.0KVAC O/P-FG:1.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/
70% RH
EMC EMISSION **Note.5| Compliance to BS EN/EN55015,BS
EN/EN61000-3-2 Class C (@load≧50%) ; BS EN/EN61000-3-3;GB/T17743,GB17625.1,EAC
TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS
EN/EN61547, light industry level(surge immunity:Line-Earth: 2KV,Line-Line:1KV)
EAC TP TC 020
****OTHERS| MTBF| 2313.3K hrs min. Telcordia SR-332 (Bellcore)
286.8Khrs min. MIL-HDBK-217F (25℃)
DIMENSION| 2803021mm (LWH)
PACKING| 0.22Kg; 54pcs/12.88Kg/0.91CUFT
NOTE**|
- All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25℃ of ambient temperature.
- Please refer to ” OUTPUT CURRENT SETTING “.
- De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.
- Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time
- The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
- This series meets the typical life expectancy of >50000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 70℃ or less.
- Please refer to the warranty statement on MEAN WELL’s website at http://www.meanwell.com
- The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanentlyconnected to the mains.
- Product Liability Disclaimer:For detailed information, please refer to https://[www.meanwell.com/serviceDisclaimer.aspx](http://www.meanwell.com/serviceDisclaimer.aspx)
BLOCK DIAGRAM
PFC fosc : 50~400KHz
PWM fosc : 30~200KHz
OUTPUT CURRENT SETTING
-
I-V Operating Area.
Output rated current level can be adjusted by a additive resistance.
-
Rated current setting table
15.2K| 19K| 24.5K| 32.5K| 43K| 46K| 72.5K| 100K| 150K| 300K| NC
---|---|---|---|---|---|---|---|---|---|---
1A| 0.9A| 0.8A| 0.7A| 0.62A| 0.6A| 0.5A| 0.45A| 0.4A| 0.35A| 0.3A
Note: output power 35W
DIMMING OPERATION
3 in 1 dimming function(for B-Type
- Output constant current level can be adjusted by applying one of the three methodologies between DIM+ and DIM-: 0 ~ 10VDC, or 10V PWM signal or resistance.
- Direct connecting to LEDs is suggested. It is not suitable to be used with additional drivers.
- Dimming source current from power supply: 100 A (typ.)
Applying additive 0 ~ 10VDC
“DO NOT connect “DIM- to Vo-”
Applying additive 10V PWM signal (frequency range 100Hz ~ 3KHz):
“DO NOT connect “DIM- to Vo-”
Applying additive resistance:
“DO NOT connect “DIM- to Vo-”
Dimming input: Additive voltage
Duty cycle of additive 10V PWM signal dimming input
(N=driver quantity for synchronized dimming operation) Dimming input:
Additive resistance
Note:
- Min. dimming level is about 8% and the output current is not defined when 0%< out<8%. I
- The output current could drop down to 0% when dimming input is about 0Vdc or 10V PWM signal with 0% duty cycle.
- To ensure the dimming performance at low dimming level,output current must be over 45mA.
DALI interface
PUSH dimming(primary side)
Action | Action duration | Function |
---|---|---|
Short push | 0.1~1 sec. | Turn ON-OFF the driver |
Long push | 1.5~10 sec. | Every Long Push changes the dimming direction, dimming |
up or down
Reset| >11 sec.| Set up the dimming level to 100%
- The factory default dimming level is at 100%.
- If the push action lasts less than 0.05 sec., it will not lead to a change for the status of the driver.
- Up to 10 drivers can perform the PUSH dimming at the same time when utilizing one common push button.
- The maximum length of the cable from the push button to the last driver is 20 meters.
- The additive push button can be connected only between the LS terminal, as displayed in the diagram, and AC/L (in brown or black); it will lead to short circuit if it is connected to AC/N.
DALI interface(primary side)
- Apply DALI signal between DA+ and DA
- DALI protocol comprises 16 groups and 64 addresses.
- First step is fixed at 8% of rated output power.
NOTE: DALI, Push dimming can not be used in the same time!(The factory setting defaults to DA)
TEMPERATURE COMPENSATION OPERATION
LDC-35 have the built-in temperature compensation function ; by connecting a
temperature sensor (NTC resistor) between the +NTC / -NTC terminal of LDC-35
and the detecting point on the lighting system or the surrounding environment,
output current of LDC-35 could be correspondingly changed, based on the sensed
temperature, to ensure the long life of LED.
- LDC-35 can still be operated normally when the NTC resistor is not connected and the value of output current will be the current level selected through the IADJ. pin
- NTC reference:
NTC resistance | Output Current |
---|---|
<20K | Output current reduce as the resistance decreases |
>20K | Normal output current |
Notes
- MEAN WELL does not offer the NTC resistor and all the data above are measured by using resistor.
- If new brand of NTC resistor is applied,please check the temperature curve first.
Dimming function of the driver will be invalid when the “temperature compensation” function is in use.
OUTPUT LOAD vs TEMPERATURE
STATIC CHARACTERISTIC
TOTAL HARMONIC DISTORTION (THD)
1000mA Model, Tcase at 75℃
POWER FACTOR (PF) CHARACTERISTIC
Tcase at 75℃
EFFICIENCY vs LOAD
LDC-35 series possess superior working efficiency up to 90%.
1000mA Model, Tcase at 75℃
LIFE TIME
MECHANICAL SPECIFICATION
Terminal Pin No. Assignment (TB1) :
Pin No. | Assignment |
---|---|
1 | ACL |
2 | ACN |
3 | NC |
4 | FG |
5 | NC(for DA-type only ) |
6 | DA-/N(for DA-type only) |
7 | DA+/Ls(for DA-type only) |
TB1 wiring:
- 0.5-0.75mm²
Terminal Pin No. Assignment (TB2) :
Pin No. | Assignment |
---|---|
1 | Vo+ |
2 | Vo+ |
3 | Vo- |
4 | Vo- |
5 | NTC |
6 | NTC |
7 | IADJ |
8 | IADJ |
9 | DIM+(for B-type only) |
10 | DIM-(for B-type only) |
TB2 wiring:
- 0.2-0.5mm²
Installation Manual
Please refer to : http://www.meanwell.com/manual.html
Downloaded from Arrow.com.