AMP APL-3026-4-B-BK Wide NovellePro Black Path and Area Light Instruction Manual

June 13, 2024
AMP

AMP-logo

AMP APL-3026-4-B-BK Wide NovellePro Black Path and Area Light

AMP-APL-3026-4-B-BK-Wide-NovellePro-Black-Path-and-Area-Light-
product

Product Information

Product Name : APL-3026-4-B-BK Luminaire
Installation & Maintenance Guide
This guide provides instructions for installing and maintaining the APL-3026-4-B-BK Luminaire. Please read these instructions carefully before proceeding.

Important Safety Instructions

This luminaire is intended for installation in accordance with local codes and the National Electric Code (NEC). Failure to adhere to these codes and instructions may result in serious injury, property damage and void the warranty.
These instructions do not intend to cover all variations in installation, operation maintenance or mounting situations.

  1. Make sure that the power is turned OFF before installing or servicing this luminaire.
  2. Warning: risk of electrical shock. Install all luminaires 10 feet (3.05M) or more from pool, spa or fountain.
  3. This luminaire is intended to be used only with a power supply (transformer) rated maximum of 300 watts (25 AMPS) at 15 volts.
  4. Wiring connections must be made with UL listed wire connectors that are suitable for outdoor use.
  5. Position the low voltage wire and wire connector so that it is located within 6 inches (15.2 cm) from a building structure, a luminaire or fitting.
  6. The main low voltage cable is intended for shallow burial – less than 6 inches (152 mm).

INSTRUCTIONS PERTAINING TO A RISK OF FIRE, OR INJURY TO PERSONS LIGHTED LAMP IS HOT!
WARNING – To reduce the risk of FIRE OR INJURY TO PERSONS.

  1. Turn off/unplug and allow to cool before replacing lamp.
  2. Lamp gets HOT quickly! Contact only switch/plug when turning on.
  3. Do not touch the hot lens, guard or enclosure.
  4. Keep lamp away from materials that may burn.
  5. Do not touch lamp at any time. Use a soft cloth. Oil from skin may damage lamp.
  6. Do not operate the luminaire fitting with a missing or damaged shield.

Package Contents

A. (1) Fixture Body

Parts Required (Sold Separately):

A. (1) G4 Bi-Pin

Product Dimensions

  • Length: 22 units
  • Width: 6 units
  • Height: 2 unitsAMP-APL-3026-4-B-BK-Wide-NovellePro-Black-Path-and-Area-Light-fig \(1\)

Product Usage Instructions

  1. Remove Lens:
    Remove the lens from the fixture by loosening the screws.

  2. Install G4 Bulb:

    • Insert the G4 Bi-Pin bulb with the correct wattage and type as marked on the fixture label. Push it into place.
    • CAUTION: Do not exceed the maximum wattage marked on the luminaire label.
    • NOTE: Use a soft cloth to handle the bulb and avoid touching it with bare hands.
  3. Install Lens:

    • Place the lens back onto the fixture and secure it with the previously removed screws. Tighten until snug.
  4. Install Stake:

    • Determine the desired location for mounting the stake mount.
    • Hammer the stake into the ground until the flange of the stake is flush to the grade.
    • To avoid damage to the stake, place a board on top of it while hammering.
    • Note: If the ground is hard and the stake is difficult to install, make a crosscut in the ground using a flat shovel.
  5. Install Fixture to Stake:

    • Pass the fixture wire through the center hole of the stake.
    • Thread the fixture onto the stake and hand tighten until snug.
  6. Wire Connections:

    • Strip both leads from the fixture body.
    • Using two wire connectors (sold separately), connect the leads from the fixture body to the leads of the main supply cable.AMP-APL-3026-4-B-BK-Wide-NovellePro-Black-Path-and-Area-Light-fig \(7\)

Install/Replace Lamp

  • Remove the glare guard and lens to expose the MR16 lamp.
  • Replace the lamp with the correct wattage and type as marked on the fixture label.
  • Reinstall the lens and glare guard after replacing the lamp.
  • IMPORTANT: Ensure that the MR16 lamp is protected from moisture and dust at all times.

1-813-978-3700
Mon-Fri 9am-6pm (EST)
Specifications and product details subject to change without notice.