TRANE 4TCA4042C1000A RunTru Air Conditioner Package Unit User Guide
- June 13, 2024
- Trane
Table of Contents
Submittal
Single Packaged
Cooling/Electric Heat
4TCA4042C1000A
October 2022
44TTCCAA44004422CC–SSUUBB–11AA–EENN
Note: “Graphics in this document are for representation only. Actual model may differ in appearance.”
Product Specifications
MODEL | 4TCA4042C1000A |
---|---|
RATED Volts/PH/Hz | 208–230 / 1 / 60 |
Performance Cooling BTUH (a) | 39500 |
Indoor Airflow (CFM) | 1300 |
Power Input (KW) | 3.54 |
EER2/SEER2 (BTU/Watt-Hr.) (b) | 10.6 / 13.4 |
Sound Power Rating [dB(A)] (c) | 79 |
POWER CONN. — V/Ph/Hz | 208–230 / 1 / 60 |
Min. Cir. Ampacity (d) | 31 |
Max. Overcurrent Protection | 50 |
COMPRESSOR | SCROLL |
Volts/Ph/Hz | 208–230 / 1 / 60 |
R.L. Amps — L.R. Amps | 19.2 / 124 |
OUTDOOR COIL — TYPE | MCHE |
Rows/F.P.I | 23-Jan |
Face Area (sq. ft.) | 13.2 |
Tube Size (in.) | 1 |
INDOOR COIL — TYPE | MCHE |
Rows/F.P.I | 16-Feb |
Face Area (sq. ft.) | 4.81 |
Tube Size (in.) | 0.81 |
Refrigeration Control | EXPANSION VALVE |
Drain Conn. Size (in.) | 3/4 MALE NPT |
OUTDOOR FAN — TYPE | PROPELLER |
DIA. (IN.) | 23 |
DRIVE/NO. SPEEDS | DIRECT / 1 |
CFM @ 0.0 in. w.g. (e) | 3540 |
Motor — HP/R.P.M | 1/5 / 825 |
Volts/Ph/Hz | 200–230 / 1 / 60 |
F.L. Amps/L.R Amps | 1.2 / 2.51 |
INDOOR FAN — TYPE | CENTRIFUGAL |
Dia. x Width (in.) | 11 X 8 |
Drive/No. Speeds | DIRECT / 3 |
CFM @ 0.0 in. w.g. (f) | SEE FAN PERF TABLE |
Motor — HP/R.P.M. | 3/4 / VARIABLE |
Volts/Ph/Hz | 208–230 / 1 / 60 |
F.L. Amps | 6.3 |
FILTER / FURNISHED | NO |
Type Recommended | THROWAWAY |
Recmd. Face Area (sq. ft) (g) | 5.3 |
REFRIGERANT | R-410A |
Charge (lbs.) | 4.24 |
CHARGING SPECIFICATIONS | |
Subcooling | 12˚ |
DIMENSIONS | H X W X L |
Crated (in.) | 36.5 X 62.5 X 40.9 |
WEIGHT | |
Shipping (lbs.) / Net (lbs.) | 430 / 400 |
(a) Rated in accordance with AHRI Standard 210/240.
(b) Rated in accordance with D.O.E. test procedure.
(c) Sound Power values are not adjusted for AHRI 270–95 tonal corrections.
(d) Calculated in accordance with currently prevailing Nat’l Electrical Code.
(e) Standard Air — Dry Coil — Outdoor.
(f) Standard Air — Dry Coil — Indoor
(g) Filters must be installed in return air stream. Square footages listed are
based on 300 f. p. m. face velocity. If permanent filters are used size per
manufacturer’s recommendation with a clean resistance of 0.05” W.C.
Outline Drawings
MODEL| HEIGHT MM/IN.| | | | | | | | | | | | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---
A| | WI| | | W2| | | W3| | | W4| | NET WEIGHT/ LBS
4TCA4024C| 918.9| [36-5/32]| 384.| (15| I/8]| 460.| [18| 1/8]| 569.| [22|
13/32]| 636.| (25| 1/32]| 400
4TCA4030C| 918.9| [36-5/32]| 384.| [15| I/8]| 460.| [18| 1/81| 569.| [22|
13/32]| 636.| [25| 1/32]| 400
4TCA4036C| 918.9| [36-5/32]| 384.| [15| I/8]| 460.| [18| 1/81| 569.| [22|
13/32]| 636.| [25| 1/32]| 420
4TCA4042C| 918.9| [36-5/32]| 384.| (15| I/8]| 460.| [18| 1/8]| 569.| [22|
13/32]| 636.| (25| 1/32]| 420
4TCA4048C| 1045.8| [41-5/32]| 460.| [18| I/8]| 511.| [20| 1/8]| 645.0| [25|
13/32]| 712.| [28| 1/32]| 440
4TCA4060C| 1045.8| [41-5/32]| 460.| [18| I/8]| 511.| [20| 1/8]| 645.0| [25|
13/32]| 712.| [28| 1/32]| 440
Full Perimeter Roof Mounting Curb
Figure 3. 2.0 — 5.0 Ton Models
BAYCURB060A Full Perimeter Roof Mounting Curb
The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use.
SERVICE CLEARANCE DIMENSIONS
A| B| C| D
12| 42| 42| 36
Supplementary Electric Heaters
Table 1. BAYHTR1V — Supplementary Electric Heaters
UNIT MODEL| ELECTRIC HEATER MODEL| RATED VOLT- AGE| PHASE| AMPS| HEATER CAPACITY| NO. OF
STAGES
| KW/STAGE| MCA| MAX. OVER CURRENT PROTEC- TION DEVICE
---|---|---|---|---|---|---|---|---|---
KW| BTUH| 1| 2
4TCA4024C1000A
4TCA4030C1000A
4TCA4036C1000A
4TCA4042C1000A
4TCA4048C1000A
4TCA4060C1000A| BAYHTR1V05LUGAA| 208/240| 1| 17/20| 3.6/4.8| 12300/16400| 1|
3.6/4.8| —| 22/25| 25/25
BAYHTR1V08LUGAA| 208/240| 1| 28/32| 5.76/7.68| 19700/26200| 1| 5.76/7.68| —|
35/40| 35/40
BAYHTR1V10LUGAA| 208/240| 1| 35/40| 7.2/9.6| 24600/32800| 1| 7.2/9.6| —|
43/50| 45/50
4TCA4030C1000A
4TCA4036C1000A
4TCA4042C1000A
4TCA4048C1000A
4TCA4060C1000A| BAYHTR1V15BRKAA| 208/240| 1| 52/60| 10.8/14.4| 36900/ 49100|
2| 7.2/9.6| 3.6/4.8| 65/75| 70/80
4TCA4048C1000A
4TCA4060C1000A
4TCA4060C1000A| BAYHTR1V20BRKAA| 208/240| 1| 69/80| 14.4/19.2|
49100/65500| 2| 7.2/9.6| 7.2/9.6| 87/100| 90/100
1. Any power supply and circuits must be wired and protected in accordance
with local electrical codes.
2. The values listed in the above table are for the electric heater only.
3. Field wiring must be rated at least 75° C.
4. * indicates an alpha character
**** ALL VALUES ARE FOR THE ELECTRIC HEATER ONLY
Table 2. BAYSPEK — Single Power Entry Kit
SINGLE CIRCUIT POWER AMPACITY AND OVER CURRENT PROTECTION
UNIT MODEL| SINGLE POWER ENTRY KIT| HEATER MODEL| MIN CKT AMP| MAX OVER-
CURRENT DEVICE
4TCA4042C| BAYSPEK071| BAYHTR1V15| 83| 90
BAYSPEK072| BAYHTR1V05| 33| 50
BAYHTR1V08| 48| 50
BAYHTR1V10| 58| 60
Mechanical Specifications
General
The units shall be horizontal airflow as shipped and convertible to downflow.
All units shall be factory assembled, piped, internally wired and fully
charged with refrigerant. Units shall be certified to UL Standard 1995. All
units shall be factory run tested to check
cooling operation, fan and blower rotation and control or TXV sequence. Units
shall be designed to operate at ambient temperatures between 115°F and 55°F in
cooling as manufactured. Cooling performance shall be rated in accordance with
AHRI standards.
Unit Casing
All components shall be mounted in a weather resistant steel cabinet with an
enamel finish. Access panels shall be provided for unit controls and indoor
coil and fans. Indoor air section compartment shall be completely insulated
with fireproof, permanent,
odorless fiber material. Knockouts shall be provided for utility and control
connections. Drain connections shall be provided to accommodate indoor water
runoff.
Compressor (2 and 2 1/2 Ton Models)
The compressor shall be hermetically sealed, high efficiency rotary
compressors. Internal overcurrent and over temperature protection, internal
pressure relief shall be standard. Other features include centrifugal oil
pump, low vibration and noise.
Compressor (3-5 Ton Models)
The compressor shall be hermetically sealed, high efficiency scroll
compressors. Internal overcurrent and over temperature protection, internal
pressure relief shall be standard. Other features include centrifugal oil
pump, low vibration and noise.
Refrigeration System
All units shall have refrigerant control. Service pressure tap ports and a
refrigerant line filter shall be standard.
Evaporator Coil (2-4 Ton Models) All aluminum micro channel, extruded
tubes, mechanically bonded to aluminum fins, and factory pressure and leak
tested at 480 — 650 psig. All units have TXV to control refrigerant flow.
Evaporator Coil (5 Ton Model) Internally enhanced 3/ 8” OD seamless
copper tubing mechanically bonded to aluminum fins, factory pressure and leak
tested at 480 — 650 psig. All units have TXV to control refrigerant flow.
Condenser Coil
All aluminum micro channel, extruded tubes, mechanically bonded to aluminum
fins, and factory pressure and leak tested at 480 — 650 psig.
Indoor Air Fan
Constant To rgue, forward-curved, centrifugal wheel in a Metallic Blower
housing. Motor shall have thermal overload protection and permanently
lubricated motor bearings. Motor/blower assembly isolated from unit with
rubber mounts.
Outdoor Fan
One direct-drive, statically and dynamically balanced propeller fan shall be
used in a draw-through vertical discharge configuration. Permanently
lubricated weather proof motor shall have built-in thermal overload
protection.
System Controls
System controls include condenser fan, evaporator fan and compressor
contactors.
Accessories Roof Curb
The roof curb shall be designed to mate with the unit and provide support and
complete weathertight installation when properly installed. Adhesive back
polyurethane sealing strips shall be provided to ensure an airtight seal
between supply and return openings of the curb and unit. The roof curb design
allows field fabricated ductwork to be connected directly to the curb. Curb
ships knocked down for field assembly, and includes factory installed wood
nailer strips.
Electric Heaters
Each heater assembly shall include power supply fusing if over 48 amps,
automatic resetting limit switches and heat limiters for thermal protection.
Heaters shall be provided with polarized plugs for quick connection to unit
low voltage wiring. Electric heat modules shall be UL listed.
Single Source Power Entry
This accessory when used with electric heat accessory shall allow single
source power connection to unit and heater combination. Single source power
entry kits shall have specific matching heater(s). Kit shall include high
voltage terminal blocks, fuse blocks and fuses, cut-to-length interconnecting
wiring, and junction box (if required) to provide power sources with fuse
protection as required for both the unit and accessory heater. Kit components
shall install within the heater cabinet in the heater access section. Single
source branch power circuit shall be protected and wired in accordance with
local codes.
Start Kit
Extra compressor starting capacity for single phase equipment.
Control Options
Standard Indoor Thermostats
Two stage heating/cooling or one stage heating/ cooling thermostats shall be
available in either manual or automatic changeover.
Programmable Electronic Night Setting Thermostat
Programmable electronic thermostat shall provide heating setback and cooling
setup with 7-day programming capability. 1H/1C or 2H/2C models available.
About Trane and American Standard Heating and Air Conditioning
Trane and American Standard create comfortable, energy efficient indoor
environments for residential applications. For more information, please visit
www.trane.com or
www.americanstandardair.com.
The AHRI Certified mark indicates company participation in the AHRI
Certification program. For verification of individual certified products, go
to ahridirectory.org.
The manufacturer has a policy of continuous data improvement and it reserves
the right to change design and specifications without notice. We are committed
to using environmentally conscious print practices.
4TCA4042C-SUB-1A-EN 28 Oct 2022 Supersedes (New)
©2022