TRANE A801X080CM5SC RunTru Central Air Conditioner and Gas Furnace Split System
Important Information
Note: Models may have a “T” in the 12th digit designating they meet California less than 40 ng/J (NOx) emissions requirements
Note: Graphics in this document are for representation only. Actual model may differ in appearance.
Outline Drawing
Table 1. 21” Width Cabinet
Product Specifications
MODEL | A801X080CM5SC (a) |
---|---|
Type | Upflow / Horizontal / Downflow |
RATINGS (b) | |
Input BTUH | 80,000 |
Capacity BTUH (ICS) (c) | 64,700 |
Temp. Rise (Min. – Max.) °F | 30 – 60 |
AFUE – Rating (c) | 80 |
Return Air Temp. (Min. – Max.) °F | 55°F – 80°F |
BLOWER DRIVE | DIRECT |
Diameter – Width (in.) | 11 X 11 |
No. Used | 1 |
Speeds (No.) (d) | CTM – 9 |
CFM vs. in. w.g. | See Fan Performance Table |
Motor HP | 1 |
R.P.M. | 1050 |
Volts / Ph / Hz | 120 / 1 / 60 |
FLA | 10.9 |
COMBUSTION FAN – Type | PSC |
Drive – No. Speeds | Direct – 1 |
Motor RPM | 3300 |
Volts/Ph/Hz | 120 / 1 / 60 |
FLA | 0.30 |
Inducer Orifice | 1.80 |
FILTER – Furnished? | No |
Type Recommended | High Velocity |
Hi Vel. (No.-Size-Thk.) | 1 – 20 X 25 – 1 in. |
MODEL | A801X080CM5SC (a) |
--- | --- |
VENT PIPE DIAMETER – Min.
(in.) (e)
| ****
4 Round
HEAT EXCHANGER – Type| Aluminized Steel
Gauge (Fired)| 20 – 19
ORIFICES – Main|
Nat. Gas Qty. – Drill Size| 4 – 45
L.P. Gas Qty. – Drill Size| 4 – 56
GAS VALVE| Redundant – Single Stage
PILOT SAFETY DEVICE – Type| 120 V SiNi Igniter
BURNERS – QTY| 4
POWER CONN. – V/Ph/HZ (f)| 120 / 1 / 60
Ampacity (Amps)| 14.1
Max. Overcurrent Protection (Amps)| ****
15
PIPE CONN. SIZE (IN.)| 1/2
DIMENSIONS| H x W x D
Uncrated (in.)| 34 x 21 x 28.75
Crated (in.)| 35.5 x 23 x 30.87
WEIGHT|
Shipping (Lbs.)/Net (Lbs.)| 142 / 134
- (a) Central Furnace heating designs are certified to ANSI Z21.47 – latest edition.
- (b) For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 10,000 feet for elevations above 2,000 feet above sea level.
- (c) Based on U.S. government standard tests.
- (d) 9 Speed constant torque ECM Blower Motor.
- (e) Refer to the Installer’s Guide.
- (f) The above wiring specifications are in accordance with National Electric Code, however, installations must comply with local codes.
Airflow Table
Furnace Airflow (CFM) Vs. External Static Pressure (in. W.C.)
Model| Tap| Static| 0.1| 0.3| 0.5| 0.7|
0.9
A801X080CM5SC| 1| SCFM| 728| 358| | |
Watts| 44| 49| | |
2| SCFM| 809| 540| 271| |
Watts| 53| 63| 74| |
3| SCFM| 1440| 1273| 1105| 938| 770
Watts| 185| 201| 218| 234| 250
4| SCFM| 1536| 1385| 1233| 1081| 929
Watts| 220| 238| 257| 275| 293
5| SCFM| 1689| 1552| 1414| 1277| 1140
Watts| 278| 299| 320| 342| 363
6| SCFM| 1792| 1661| 1530| 1400| 1269
Watts| 326| 348| 371| 394| 417
7| SCFM| 1899| 1771| 1643| 1515| 1387
Watts| 373| 397| 422| 446| 471
8| SCFM| 2094| 1985| 1875| 1766| 1656
Watts| 500| 527| 554| 582| 609
9| SCFM| 2533| 2414| 2295| 2176| 2058
Watts| 931| 932| 933| 933| 934
CFM Versus Temperature Rise
Table 2. A801X
Model | CFM Versus Temperature Rise |
---|---|
400 | 500 |
1800 | 1900 |
A801X080CM5SC |
General Features
NATURAL GAS MODELS
Central Heating furnace designs are certified by Intertek for both natural and L.P. gas. Limit setting and rating data were established and approved under standard rating conditions using American National Standards Institute standards.
SAFE OPERATION
The Integrated System Control is a solid state device which continuously monitors for presence of flame when the system is in the heating mode of operation. Dual solenoid combination gas valve and regulator provide additional safety.
QUICK HEATING
Durable, cycle tested, heavy gauge tubular aluminized steel heat exchanger quickly transfers heat to provide warm conditioned air to the structure. Low energy power vent blower, to increase efficiency and provide a discharge of gas fumes to the outside.
BURNERS
Multiport, Inshot burners will give years of quiet and efficient service. All models can be converted to L.P. gas with LP conversion kit.
INTEGRATED SYSTEM CONTROL
Exclusively designed operational program provides total control of furnace limit sensors, blowers, gas valve, flame control and includes self diagnostics for ease of service.
ENERGY EFFICIENT OPERATION
Air-Tite™ cabinet design is certified to <1.4% air leakage per ASHRAE 193 “Method of Test for Determining the Airtightness of HVAC Equipment.”
AIR DELIVERY
The 9 speed constant torque blower motor has sufficient airflow for most heating and cooling requirements and will switch from heating to cooling speeds on demand from room thermostat.
STYLING
Heavy gauge steel and “wrap-around” cabinet construction is used for strength. Every orientation has at least two venting options. There are no knockouts on cabinet.
FEATURES AND GENERAL OPERATION
The furnace utilizes a Silicon Nitride Hot Surface Ignition system, which eliminates the waste of a constant burning pilot. The integrated system control lights the main burners upon a demand for heat from the room thermostat. Complete front service access.
- a. Low energy power venter
- b. Vent proving pressure switches.
Features and Benefits
80% AFUE on A801X FURNACE MODELS
Lowers utility bills
ELECTRICALLY EFFICIENT
Efficient airflow design reduces electrical energy use
34 INCH TALL
Lighter, easier to move and fit into tight spaces like short basements or
tight closets
Works great with larger, high-efficiency coils
No knockouts
4–WAY MULTI-POISE
8 SKU’s — Upflow / Downflow / Horizontal Left / Horizontal Right
Added application flexibility and reduction in specification errors
AIRFLOW
At least 400 CFM/ton at 0.5 in. H20 external static pressure
REGULATORY
All models are air tight; 1.4% or less air leakage as per ASHRAE 193
Open vestibule design provides a full 34” high open vestibule for ease of installation and service.
DIMENSIONS
Width is industry standard: 21”
Depth remains approximately 28”
Cabinet is compatible with industry standard coils, as well as, other
accessories.
INTEGRATED FURNACE CONTROL
- Setup / Status / Diagnostics / Digital Display
- No dip switches
- Last six errors stored
- All Molex connections; no spade terminals
- Low voltage labeled above and below
- Rain shield over IFC keeps condensate off the control
TUBULAR ALUMINIZED STEEL HEAT EXCHANGER 9 SPEED CONSTANT TORQUE BLOWER MOTOR
Greater range of operation
Higher efficiency versus a standard PSC blower motor
Taps are electronically selectable at the IFC
FOUR–WAY MULTI-POISE (UPFLOW, DOWNFLOW, HORIZONTAL LEFT AND RIGHT)
Easier to specify
Shipped ready to install (no conversion kits required)
Every model has at least two venting options
About Trane and American Standard Heating and Air Conditioning
Trane and American Standard create comfortable, energy efficient indoor
environments for residential applications. For more information, please visit
www.trane.com or
www.americanstandardair.com.
The manufacturer has a policy of continuous data improvement and it reserves
the right to change design and specifications without notice. We are committed
to using environmentally conscious print practices.
A801X080CM5-SUB-3B-EN 31 Mar 2023
Supersedes A801X080CM5-SUB-3A-EN (July 2021)
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>