Product Information

  • Product Name: CondenseSpot
  • Pro Model Number: Rev23W25
  • Power Output : < 1 mW
  • Battery Type: 2 x 1.5V LR6 (AA)
  • Languages: DE, EN, NL, DA, FR, ES, IT, PL, FI, PT, SV, NO, TR, RU, UK, CS, ET, RO, BG, EL, HR

Product Usage Instructions

Before using the CondenseSpot Pro, make sure to read the user manual and warranty information provided.

Safety Precautions:

  • Avoid looking directly into the laser beam. – Follow the guidelines for handling Class 2 lasers.
  • Be cautious of electromagnetic radiation and RF-funk radiation.
  • Follow the maintenance and calibration instructions provided.

Battery Installation :

  • Open the battery compartment by sliding it open. –
  • Insert 2 x 1.5V LR6 (AA) batteries in the correct polarity (+/-).
  • Close the battery compartment securely.

Operating the CondenseSpot Pro:

  • Press the ON/OFF button for 1 second to turn on the device.
  • The device will automatically shut off after 30 seconds of inactivity.
  • Ensure that the humidity/ambient temperature sensor is folded during transport.

Infrared Temperature Measurement:

  • Press the INFRARED TEMPERATURE button to switch to the infrared temperature measurement mode.
  • The display will show the measured infrared temperature.

Adjusting Emissivity:

  • Press the EMISSION button to enter the emissivity adjustment mode.
  • Use the UP and DOWN buttons to adjust the emissivity value (0.01 to 1.00).
  • Refer to the emissivity table provided in the user manual for reference values.

Additional Features:

  • The device has an alarm function that can be turned on/off.
  • The device also includes an air humidity/temperature sensor, an infrared sensor, and an 8-point laser circle. 8.

Maintenance:

  • Follow the maintenance and care instructions provided in the user manual.
  • Perform regular calibration of the device as instructed.

Note : For detailed information on specific features, functions, and safety precautions, refer to the complete user manual included with the CondenseSpot Pro.

Completely read through the operating instructions, the „Warranty and Additional Information“ booklet as well as the latest information under the internet link at the end of these instructions. Follow the instructions they contain. These documents must be kept in a safe place and passed on together with the device

Intended use
The CondenseSpot Pro is an infrared temperature-measuring device with an integrated hygrometer and a Digital Connection interface for transferring measured data. Non-contact temperature measurement of surfaces is realized by measuring and evaluating the amount of electromagnetic energy in the infrared wavelength range. The device can also be used to measure all relevant climate data and calculate the dew point. This makes it possible to assess thermal bridges and condensation moisture

General safety instructions

  • The device must only be used by its intended and within the scope of the specifications
  • The measuring tools and accessories are not Kept out of reach of children.
  • Modifications or changes to the device are not permitted, this will otherwise invalidate the approval and safety specifications
  • Do not expose the device to mechanical stress, extreme temperatures, moisture, or significant
  • The device must no longer be used if one or more of its functions fail or the battery charge is specifications
  • When using the device outdoors, make sure that the weather conditions are appropriate and/or that suitable protection measures are taken.
  • Please ensure compliance with the safety regulations set out by local and national authorities about the correct and proper use of the device.

Safety instructions

Using class 2 lasers

Laserliner-082-049A-CondenseSpot-Pro-FIG- \(1\)

IEC 60825-1:2014, EN 60825-1:2014/A11:2021

  • Attention: Do not look into the direct or reflected
  • Do not point the laser beam towards persons.
  • If a person‘s eyes are exposed to class 2 laser radiation, they should shut their eyes and immediately move away from the beam.
  • Under no circumstances should optical instruments (magnifying glass, microscope, binoculars)
  • Do not use the laser at eye level (1.40…1.90 m)
  • Tampering with (making changes to) the laser device is not permitted.

Laser outlet

Laserliner-082-049A-CondenseSpot-Pro-FIG- \(2\)

Safety instructions

Dealing with electromagnetic radiation

  • The measuring device complies with electromagnetic compatibility regulations and limits by the EMC Directive 2014/30/EU which is covered by the Radio Equipment Directive 2014/53/EU.
  • Local operating restrictions – for example, in hospitals, aircraft, petrol stations, or in the vicinity of people with pacemakers – may apply. Electronic devices can potentially cause hazards or interference or be subject to hazards or interference.
  • The measuring accuracy may be affected when working close to high voltages or high electromagnetic alternating fields.

Dealing with RF radiation

  • The measuring device is equipped with a wireless interface.
  • The measuring device complies with electromagnetic compatibility and wireless radiation regulations and limits by the RED 2014/53/EU.
  • Umarex GmbH & CO. KG hereby declares that the CondenseSpot Pro radio equipment meets the requirements and other specifications of the European Radio Equipment Directive 2014/53/EU (RED). The EU Declaration of Conformity can be found in its entirety at the following address: https://www.laserliner.com

Information on maintenance and care

  • Clean all components with a damp cloth and do not use cleaning agents, scouring agents, and solvents.
  •  Remove the battery(ies) before storing it for longer periods. Store the device in a clean and dry place.

Calibration
The measuring device must be calibrated and tested regularly to ensure it is accurate and working properly. We recommend carrying out calibration once a year. Contact your distributor or the UMAREX-LASERLINER service department

  1. LC display
  2. Set emissivity factor
  3. Alarm function ON/OFF
  4. Humidity / ambient temperature sensor
  5. Infrared sensor
  6. 8-point laser circle outlet
  7. Switch between ambient/dew point temperature / MIN/MAX temperature
  8. ON / trigger
  9. Battery compartment
  10. 1/4″ tripod threadsLaserliner-082-049A-CondenseSpot-Pro-FIG- \(3\)

OVERVIEW

  • Condensation warning
  • Bar graph, condensation moisture indicator
  • Relative humidity measured value
  • Measured value in selected mode (MIN/dew point temperature) / emissivity factor display
  • Measure value in selected mode (MAX / ambient temperature)
  • Measured value, infrared temperature
  • Measurement °C
  • Battery charge
  • The laser beam was switched on, and temperature measurement (infrared)
  • Hold function
  • Thermal bridge warning
  • Digital Connection function active
  • Alarm function deactivated
  • Alarm function active

Inserting batteries
Open the battery compartment and insert batteries according to the symbols. Be sure to pay attention to polarity.

ON / OFF
The device can also be switched on with the alarm function button (3). No measurement is triggered and the last measured values are displayed.

Auto switch-off after 30 seconds. Make sure that the humidity/ambienttemperature sensor (4) is folded in during transport

Infrared temperature measurement / continuous measurement / Hold

Laserliner-082-049A-CondenseSpot-Pro-FIG- \(7\)

CondenseSpot Pro

  • For continuous measurement activate the laser (see figure) and keep the button pressed.
  • Release the button as soon as the target laser pinpoints the measurement location. The measured value is held (Hold).

Infrared temperature: Setting the emissivity

An integrated sensor head detects the material/surface-specific infrared radiation emitted by all objects. The level of these emissions is determined by the specific emissivity of the material (0,01 to 1,00). After switching it on for the first time, the device is preset to an emissivity factor of 0.95, which is suitable for most organic materials and non-metals (plastics, ceramics, wood, rubber, paints, varnishes, and stone). For materials with different emissivity factors, refer to the table under Point 6.

Wherever possible, paint or matt black stickers can be applied on non-coated metals and metal oxides, which due to their low, temperature-unstable emissivity are suitable for IR measurement only for a limited extent, as well as on surfaces with unknown emissivity to set the emissivity factor to 0.95. If this is not possible, use a contact thermometer.

The emissivity last selected is set after the device is switched on! Check the emissivity setting before each measurement.

Emissivity factor settingLaserliner-082-049A-CondenseSpot-Pro-FIG-
\(10\)

Emission coefficient tables
Reference values with tolerances

METALSLaserliner-082-049A-CondenseSpot-Pro-FIG- 20

Non-metalsLaserliner-082-049A-CondenseSpot-Pro-FIG-
21

Infrared temperature: MAX/MIN temperature

MAX/MIN mode refers to the infrared temperature and shows the maximum and minimum infrared temperature. The MAX/MIN values are determined while measuring when the trigger (8) is pressed. The value is deleted and calculated again at the start of a new measurement or by pressing the trigger (8).

Room climate measured values
The measuring device features a fold-out sensor that measures the ambient temperature and relative humidity while also calculating the dew point temperature. By folding out the sensor, the improved through-flow of air speeds up the measurement procedure.

When changing location and/or where there are large differences in the room climate, it is important to give the measuring device time to adapt until the measured values in the display have stabilized! The measured ambient temperature and relative humidity values are automatically updated! and is not dependent on when the trigger button is pressed.

Condensation warning
The dew point temperature is the point the temperature must drop below for the air to precipitate its water vapor in the form of droplets, mist, or dew. Condensation water therefore occurs for example when the temperature of an inside wall or window reveal is lower than the dew point temperature of the room. These areas are then damp and are a breeding ground for mildew/mold with possible material damage.

The CondenseSpot Pro calculates the dew point with the integrated sensors for ambient temperature and relative humidity. At the same time, the surface temperature of objects is determined with the aid of infrared temperature measurement. By comparing this temperature it is possible to identify areas that are exposed to the risk of condensation moisture. The condensation moisture indicator (b) displays the result in the form of a bar graph, supported by visual and acoustic signals indicating the high probability of condensation moisture occurring.

Laserliner-082-049A-CondenseSpot-Pro-FIG- \(13\)

  • No risk of condensation moisture
  • Slight risk of condensation  moisture „ “ symbol flashing
  • Risk of condensation moisture „  symbol flashing with an acoustic signal

The condensation moisture indicator (b) is shown in all modes. The device therefore constantly shows the risk level of condensation moisture. The visual and acoustic signals can be turned off by pressing the alarm function button (3). The symbols “ ” (m) and “ ” (n) indicate whether the alarm function is active or not.

Thermal bridge warning
In relation to buildings, the term thermal bridge refers to an area, e.g. an inside wall, at which heat is transferred outwards faster than at the rest of the inside wall. When viewed from the inside, the temperature of this area is lower than the surrounding areas, and when viewed from the outside higher than the surrounding areas. This often indicates faulty or inadequate insulation. For this purpose, the CondenseSpot Pro compares the ambient temperature with the surface temperature. If there are large differences in both temperatures, the device will trigger warnings in 2 stages:

The symbol flashes at the threshold or the display illumination changes to ‘blue’ or ‘red’ if the differential is significant.

  • Ambient temperature/ surface temperature differential: < 3.5°C no thermal bridge
  • Ambient temperature/surface temperature differential.: ≥ 3.5°C possible thermal bridge, the “ ” flashes, check area againLaserliner-082-049A-CondenseSpot-Pro-FIG- \(16\)
  • Ambient temperature/ surface temperature differential: ≥ 6.5°C thermal bridge, Blue display, and the “ ” symbol flashes
  • Ambient temperature/surface temperature differential: ≥ -6.5°C thermal bridge, Red display, and the “ ” symbol flashesLaserliner-082-049A-CondenseSpot-Pro-FIG- \(17\)

The visual and acoustic signals can be turned off by pressing the alarm function button (3). The symbols “ ” (m) and “ ” (n) indicate whether the alarm function is active or not.

Data transfer
The device features a Digital Connection function that enables wireless data transfer to mobile devices with a Digital Connection interface (such as a smartphone or tablet). The system prerequisites for a Digital Connection connection are specified at  https://packd.li/ble/v2

The device can set up a Digital Connection connection with Bluetooth 4.0 compatible devices.  The range is set to a maximum distance of 10 m from the terminal device and greatly depends on the ambient conditions such as the thickness and composition of walls, sources of interference as well as the transmit/receive properties ofthe terminal device. Once it has been activated, Digital Connection remains switched on indefinitely as the radio system is designed with exceptionally low power consumption. A mobile device can link up to the active measuring device via an app.

Application (app)
An app is required to use the Digital Connection function. You can download the app from the corre-sponding stores for the specific type of terminal device:

Laserliner-082-049A-CondenseSpot-Pro-FIG- \(18\)

Make sure that the Digital Connection interface of the mobile device is activated.

After starting the app, a connection can be set up between a mobile device and the measuring device. If the app detects several active measuring devices, select the matching device. This measuring device can be connected automatically the next time it is switched on.

Technical data

Technical data (Technical revisions reserved. 23W26)

Measured variable| Infrared temperature, humidity,

ambient temperature, dew point temperature

Functions| Hold, min./max., condensation warning, thermal bridge warning
Measuring range ambient temperature| -20°C … 65°C
Accuracy ambient temperature| 0°C … 50°C (± 1°C); <0°C and >50°C (± 2.5°C)
Resolution ambient temperature| 0,1°C
Measuring range infrared temperature| -40°C … 600°C

Accuracy infrared temperature

| -40°C … 0°C (± (1°C + 0.1°C/1°C)) 0°C … 30°C (± 1°C)

30°C (± 2°C or ± 2%, depending on the higher value)

Resolution infrared temperature| 0,1°C
Measuring range humidity (relative)| 1% … 99%
Accuracy (absolute) Humidity (relative)| 20% … 80% (± 3%)

<20% and >80% (± 5%)

Humidity resolution (relative)| 0,1%
Measuring range dew point temperature| -50°C … 50°C

Accuracy dew point temperature

| 20% rH … 30% rH (± 2,5°C)

31% rH … 40% rH (± 2°C)

41% rH … 95% rH (± 1,5°C)

Resolution of dew point temperature| 0,1°C
Optics| 12:1 (12 m distance: 1 m measured spot)
Emission coefficient| adjustable, 0.01 … 1.00
Laser| 8-point laser circle
Laser wavelength| 650 nm
Laser class| 2 / < 1 mW (IEC 60825-1:2014, EN 60825-1:2014/A11:2021)
Power supply| 2 x 1,5V LR6 (AA)
Operating time| approx. 20 hours
Operating conditions| 0°C … 50°C, max. humidity 80% rH, no condensation, max. working altitude 2000 m above sea level
Storage conditions| -10°C … 60°C, max. humidity 80% rH, no condensation
Radio module operating data| IEEE 802.15.4. LE ≥ 4. x (Digital Connection) interface; Frequency band: ISM band 2400–2483.5 MHz, 40 channels; Transmission power: max. 10 mW; Bandwidth: 2 MHz; Bit rate: 1 Mbit/s; Modulation: GFSK/FHSS
Dimensions (W x H x D) / Weight| 150 x 90 x 60 mm / 380 g (incl. batteries)

EU and UK directives and disposal
The product complies with all necessary standards for the free movement of goods within the EU and the UK. This product, including accessories and packaging, is an electrical appliance that must be recycled in an environmentally appropriate manner by European and UK directives on waste electrical and electronic equipment, batteries, and packaging, to recover valuable raw materials.

Further safety and supplementary notices at: https://www.laserliner.com

CondenseSpot ProLaserliner-082-049A-CondenseSpot-Pro-FIG-
\(19\)

Umarex GmbH & Co. KG – Laserliner Gut Nierhof 2 59757 Arnsberg, Germany Tel.: +49 2932 9004-0 [email protected] https://www.laserliner.com MADE IN PRC