Product Information
Product Name: C-Band 17/20dBm SM Booster EDFA Mini Module with 20/30dB Gain
Manufacturer: Photonwares Company
Address: 15 Presidential Way Woburn, MA 01801
Contact: Tel: 781-935-1200, Fax: 781-935-2040
Website: www.agiltron.com
Part Number: EDFA-1C0(2)111xxx-xx
User Manual: Available
Product Usage Instructions
Ambient Parameters
| Parameter | Min. | Typical | Max. | Unit |
|---|---|---|---|---|
| Working Temperature | -5 | 65 | °C | |
| Storage Temperature | -40 | 85 | °C | |
| Working Humidity | 5 | 85 | % | |
| Storage Humidity | 5 | 95 | % |
Optical Parameters
| Parameter | Min. | Typical | Max. | Unit | Note |
|---|---|---|---|---|---|
| Return Loss | 45 | dB | |||
| Input & Output Fiber type | SMF-28e, 900um white loose tube | ||||
| Output Fiber Length | 99 | cm | |||
| Input Fiber Length | 99 | cm | |||
| Input & Output Fiber Connector Type | FC/APC | ||||
| Module Dimension (WLH) | 907015 | mm | |||
| Working Mode | AGC | ||||
| No Optical Power Report | -60 | dBm | |||
| Output power stability | 35 | dB | |||
| Accuracy of power reporting | 0.5 | ps | |||
| Gain control accuracy | 0.5 | ps/nm | |||
| Output Power control accuracy | 0.5 | dB | |||
| Input & Output Isolation | dB | ||||
| In & Out Pump Leakage | -40 | dB | |||
| PDG | |||||
| PMD | -30 | ps | |||
| CD | -31 | ps/nm | |||
| Multipath interference | -8 | dB |
Operating Parameters
| Parameter | Typical | Max. | Unit |
|---|---|---|---|
| Operating Wavelength | 1528 | 1565 | nm |
| Input Power Range | -30 | -10 | dBm |
| Gain | 20/30 | 17/20 | dB |
| Max Output Power | 5.5 | dBm | |
| Input @ Typical NF GF | |||
| Input Power Alarm Threshold | -33 | -31 | dBm |
| Output Power Alarm Threshold | -8 | -6 | dBm |
| Pump off threshold | 1565 | 10 | nm |
| APC Output power setting range | 33 | 6 | dBm |
| Default temperature alarm threshold | 1.5 | -10 | °C |
| Ports | 1 | 20.5 |
Flatness
No information available.1 Ambient Parameters
Ambient Parameters
| Parameter | Min. | Typical | Max. | Unit | Note |
|---|---|---|---|---|---|
| Working Temperature | -5 | 65 | ℃ | ||
| Storage Temperature | -40 | 85 | ℃ | ||
| Working Relative Humidity | 5 | 85 | % | 40°C non- condensation | |
| Storage Relative Humidity | 5 | 95 | % |
Optical Parameters
| Parameter | Min | Typical | Max | Unit | Note |
|---|---|---|---|---|---|
| Return Loss | 45 | – | – | dB | |
| Input & Output Fiber type | SMF-28e, 900um white loose tube | – | |||
| Output Fiber Length | 99 | 100 | 101 | cm | 100 ± 1cm, |
without connector
Input Fiber Length| 99| 100| 101| cm| 100 ± 1cm,
without connector
Input & Output Fiber Connector Type| FC/APC| –|
Module Dimension| (WLH)907015| mm|
Working Mode| AGC| |
No Optical Power Report| -60| dBm|
Output power stability| –| –| ±0.1| dB|
Accuracy of power reporting| –| –| ±0.5| dB|
Gain control accuracy| –| –| ±0.5| dB|
Output Power control accuracy| –| –| ±0.5| dB|
Input & Output Isolation| –| 35| –| dB|
In & Out Pump Leakage| –| –| -30| dBm|
PDG| –| –| 0.5| dB|
PMD| –| –| 0.5| ps|
CD| –| –| ±5| ps/nm|
Multipath interference| –| –| -40| dB|
Operating Wavelength| 1528| –| 1565| nm|
---|---|---|---|---|---
Input Power Range| -30| –| 10| dBm|
| | | | | Flatness<2.0
| | | | | Gain adjustable range is
Gain
| ****
20
| 20/
30
| ****
33
| ****
dB
| ±1.5dB.
Accuracy of normal
| | | | | temperature gain setting is
| | | | | 0.1dB.
Max Output Power| 17/20| dBm|
Input @ Typical| -10| dBm|
NF| –| 5.5| 6| dB| @Gain=20dB
GF| –| 1| 1.5| dB| @In=-3dBm,G=20dB
| | | | | Settable range -33 ~ -10 dBm,
Input Power Alarm Threshold| ****
-33
| ****
-31
| ****
-10
| ****
dBm
| Upward hysteresis 1dB,
<-33dBm reporting no optical
| | | | | power
Output Power Alarm Threshold| ****
-8
| ****
-6
| ****
20.5
| ****
dBm
| Settable range -8 ~ +20.5, Upward hysteresis 1dB,
<-8 reporting no optical power
Operating Wavelength| 1528| –| 1565| nm|
---|---|---|---|---|---
Input Power Range| -30| –| 10| dBm|
| | | | | Flatness<2.0
| | | | | Gain adjustable range is
Gain
| ****
20
| 20/
30
| ****
33
| ****
dB
| ±1.5dB.
Accuracy of normal
| | | | | temperature gain setting is
| | | | | 0.1dB.
Max Output Power| 17/20| dBm|
Input @ Typical| -10| dBm|
NF| –| 5.5| 6| dB| @Gain=20dB
GF| –| 1| 1.5| dB| @In=-3dBm,G=20dB
| | | | | Settable range -33 ~ -10 dBm,
Input Power Alarm Threshold| ****
-33
| ****
-31
| ****
-10
| ****
dBm
| Upward hysteresis 1dB,
<-33dBm reporting no optical
| | | | | power
Output Power Alarm Threshold| ****
-8
| ****
-6
| ****
20.5
| ****
dBm
| Settable range -8 ~ +20.5, Upward hysteresis 1dB,
<-8 reporting no optical power
Operating Wavelength| 1528| –| 1565| nm|
---|---|---|---|---|---
Input Power Range| -30| –| 10| dBm|
| | | | | Flatness<2.0
| | | | | Gain adjustable range is
Gain
| ****
20
| 20/
30
| ****
33
| ****
dB
| ±1.5dB.
Accuracy of normal
| | | | | temperature gain setting is
| | | | | 0.1dB.
Max Output Power| 17/20| dBm|
Input @ Typical| -10| dBm|
NF| –| 5.5| 6| dB| @Gain=20dB
GF| –| 1| 1.5| dB| @In=-3dBm,G=20dB
| | | | | Settable range -33 ~ -10 dBm,
Input Power Alarm Threshold| ****
-33
| ****
-31
| ****
-10
| ****
dBm
| Upward hysteresis 1dB,
<-33dBm reporting no optical
| | | | | power
Output Power Alarm Threshold| ****
-8
| ****
-6
| ****
20.5
| ****
dBm
| Settable range -8 ~ +20.5, Upward hysteresis 1dB,
<-8 reporting no optical power
Electrical Indicators
Power Supply
| Parameter | Min | Typical | Max | Unit | Note |
|---|---|---|---|---|---|
| Voltage | 4.75 | 5.0 | 5.25 | V | |
| Current | – | – | 3.0 | A | |
| Power Consumption | – | – | 15 | W |
Pin definition
Communication Port
Type:34Pin 2.00mm intervals male socket CJT A2005WV-N-2x17P
Pin definition
| Pin No. | Name | Attribute | Level Type |
|---|---|---|---|
| 1 | NC | F | |
| 2 | NC | F | |
| 3 | +5V | P | |
| 4 | +5V | P | |
| 5 | +5V | P | |
| 6 | +5V | P | |
| 7 | GND | P | |
| 8 | GND | P | |
| 9 | NC | F | |
| 10 | NC | F | |
| 11 | GND | P | |
| 12 | GND | P | |
| 13 | NC | F | |
| 14 | NC | F | |
| 15 | NC | F | |
| 16 | NC | F | |
| 17 | NC | F | |
| 18 | NC | F | |
| 19 | NC | F | |
| 20 | NC | F | |
| 21 | NC | F | |
| 22 | NC | F | |
| 23 | GND | P | |
| 24 | GND | P | |
| 25 | Serial Port Input | I | LVTTL |
| 26 | Serial Port Output | O | LVTTL |
| 27 | GND | P | |
| 28 | GND | P | |
| 29 | +5V | P | |
| 30 | +5V | P | |
| 31 | +5V | P | |
| 32 | +5V | P | |
| 33 | NC | F | |
| 34 | NC | F |
- P: Power
- I: Input
- O: Output,
- F: None
Serial Port Communication Protocol
| Parameter | Value | Unit |
|---|---|---|
| Baud rate | 9600 | Bit/s |
| Data bit | 8 | Bit |
| Stop bit | 1 | Bit |
| Parity bit | None |
Module Dimensions Application Notes
- RS232-to-USB converting needs to be done by user. FTDI chip is recommended.
- Benchtop is available at https://agiltron.com/.
- RS232-to-USB converting PCB is also available at https://agiltron.com/.
- Upon accomplishment of the above EDFA can be remotely controlled by UART commands or the ‘EDFA GUI’ program (EDFA-L option) provided.
- A heat sink is needed for this EDFA, as shown below.
15 Presidential Way Woburn, MA 01801
T el: 781-935-1200
Fax: 781-935-2040
www.agiltron.com